Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L1 | Accepted-AOC AOC Accepted | |
| 2 | L2₹27.0 L+₹27,981 (1.05%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹27.2 L+₹53,573 (2.01%)Rejected-AOC A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹28.0 L+₹1.3 L (4.82%)Rejected-AOC NOT FOUND | L4 | Rejected-AOC Rejected | |
| 5 | L5₹28.5 L+₹1.8 L (6.68%)Rejected-AOC 13 29 304 3RD FLOOR EAST PATEL NAGAR OPP SIDDHARTHA HOTEL NEW DELHI 08 | NEW DELHI | NEW DELHI | DELHI | 110008 | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹72,000
Closing Date
10 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (P) AF Gurgaon
GE (P) AF Gurgaon Near Atul Kataria Chowk Gurgaon
CA NO. GE (P) AF/GUR-62/2020-21 PROVISION OF STANDBY POWER SUPPLY FOR SECURITY LIGHTS AND CONNECTED WORKS IN 13 BRD AT AF STN PALAM UNDER GE (P) AF GURGAON
2020_MES_376425_1
GE (P) AF/Gur-62/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (P) AF Gurgaon
All as specified in NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹72,000
Yes
23 Oct 2020
10 Sept 2020
12 Oct 2020
11 Sept 2020
10 Oct 2020
25 Sept 2020
60 days
Amount
Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles &stay etc complete all as specified and as directed by Engr-in-Charge.
Demolition of plain cement Concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed by Engineer-in-charge.
Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed by Engr-in-charge.
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm) and punned down to 18 cm (Punned thickness shall be measured for payment) complete all as specified and as directed.
M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat complete all as specified and as directed by Engr-in-charge.
M&L for PCC 1:2:4 type B2 using 40mm grade stone aggregate as in copping of electric pole or making good of disturbed surface including necessary formwork complete all as specified and as directed by Engineer-in-charge.
M&L complete for driling hole hard standing / road for laying of pipe for protection of cable etc by means of manual booklet and without disturbing the top surface or cutting and making good the disturbed surface to the existing if any complete all as specified and directed by Engineer-in-charge.
Supply and laying GI tube light grade 80 mm bore for cable protection complete all as specified and directed by Engr-in-charge. Make - Bansal/Jindal/ITC
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and as directed .
All as per item No. 10 hereinbefore but size 25 Sqmm, 4 Core .
All as per item No. 10 hereinbefore but size 35 Sqmm, 3-1/2 Core .
All as per item No. 10 hereinbefore but size 95 Sqmm, 3-1/2 Core .
All as per item No. 10 hereinbefore but size 120 Sqmm, 3-1/2 Core .
Supply, installation, testing and commissioning of Silent Diesel engine driven generating set 25 KVA (20KW) 415Volts 3 phase 50 HZ complete with comprising the following:-
(A) Engine: (i) RPM 1500 (ii) Liquid cooled type
(B) Alternator: (i) Capacity - 25KVA (ii) Brushless 3 phase 0.8 power factor 1500RPM/ 50Hz, SPDP enclosure with H class insulation
(C) AUTO MAINS FAILURE panel for 25 KVA DG set with all connection & accessories with necessacry bypass arrangements.
(D) Others: (i) Fule tank (ii) Electrical battery voltage 12Volts with Battaries. Make:- Excide (iii) Micro-processor based Genset controllers display a host of genset parameters - Phase voltages & currents, frequency, Reverse power, Genset KVA, KW, KVAr, KWH, Power factor, Canopy Temperature, Lub oil pressure, Enginer temperature, RPM, Run hours, Number of starts, fuel level, Auto/Manual stop, battery charge condition & AMF features. (iv) Diagnostic Features:- Battery Charging failure, Over/Under speed, over current, over/under voltage, over KW, phase seq, phase missing, mains under voltage, earth fault trip & fuel usage alarm.
(E) BASE PLATE :- Base plate shall be MS fabricated and strongly welded dully ribbed suitable for receiving engine, alternator alongwith flexible coupling it shall be include set of bolts, washers, rubber coupling, drip tray and protective screen around coupling complete. Note: The complete generating set including engine/alternator shall be factory assembled by manufacturer or its autorized dealer as approved for assembling the DG sets. The DG set shall be assembled by OEM.
(F) DG SET FOUNDATION : DG set shall be installed on PCC M-15 foundation complete all as per recommendation and specification of OEM. It shall be extended 01 Meter all around the DG set acoustic enclosure. It shall be 300mm above ground level deemed to be included in quoted rates.
(G) ACOUSTIC ENCLOSURE FOR DG SET The DG shall be covered with Acoustic enclosure fabricated of MS channel & CRCA sheet 2mm thick having doors, insulation sides and top by mineral rock wool confirming to IS-8183 of adequate thickness acoustic louver/outlet, ventilation system, complete as per manufacturer recommendation with wiring and lightening arrangements, duly painted with weather proof & anti corrosive chemical. Forced ventilation shall ve provide by axial flow fan 1440 RPM suitable capacity exhaust fan and inside temp shall not be rise more than 5-8 degree centigrade.
Supply, install, testing and Modular/combinable Outdoor Floor Mounting polycarbonate insulated panel, commissioning of shock proof, safe, IP 54/65 according to IEC 60 529, weather proof, rust proof, UV resistant, halogen free, silica free, corrosion proof, protection class II, totally insulated, having internally embedded gasket with provision for cable entry through detachable flanges , flame retardant, self-extinguishing with glow wire test at 960C according to IEC 60 695-2-11; chemical resistance towards acid, lye , benzene and mineral oil; Impact strength IK 08 (5 Joule) in accordance with DIN EN 50 102. The panel manufacturer should confirms the Panel is in accordance with IEC 61 439-1& IEC 61 439-2 and Routine Test Certificate shall be submit according to that along with Panel. The manufacturer of board/ panel SHALL submit a copy of TYPE TEST REPORT ( ASTA certification by CPRI) of a board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1.
The CPRI report shall have mention of following tests performed and passed out satisfactorily. (i) Temperature Rise. (ii) Dielectric Properties . (iii) Short circuit withstand current Rated peak & short time withstand current and Rated Conditional Short Circuit Current. (iv) Effectiveness of Protective Circuits. (v) Clearance & Creepage Distance. Mechanical Operation (a) Panel should be with Padlock facility. (b) The Moduler enclosure to assemble Panel should be add with Polycarbonate wedges links. Panel Details Size - 800 [L] x 985[H] x 600 [D] mm Incomer - 3A FP 10KA MCB- 1 No Outgoing - 2A FP 10 KA MCB - 3 Nos RYB Indication Lamp, Digital Ammeter and digital Voltmeter Make- HENSEL/ESSEL
All as per item No. 16 hereinbefore but with Panel Details Size - 800 [L] x 985 [H] x 600 [D] mm Incomer - 10A FP 10KA MCCB- 1 No Outgoing - 3A FP 10KA MCB - 3 Nos RYB Indication Lamp, Digital Ammeter and digital Voltmeter Make- HENSEL/ESSEL
All as per item No. 16 hereinbefore but with Panel Details Size - 800 [L] x 985 [H] x 600 [D] mm Incomer - 16A FP 10KA MCCB- 1 No Outgoing - 6A FP 10KA MCB - 1 No 3A FP 10KA MCB - 2 Nos RYB Indication Lamp, Digital Ammeter and digital Voltmeter Make- HENSEL/ESSEL
All as per item No. 16 hereinbefore but with Panel Details Size - 800 [L] x 1135[H] x 620 [D] mm Incomer - 25A FP 16KA MCCB- 1 No Outgoing - 3A FP 10KA MCB - 3 Nos RYB Indication Lamp, Digital Ammeter and digital Voltmeter Make- HENSEL/ESSEL
All as per item No. 16 hereinbefore but with Panel Details Size - 500 [L] x 1285 [H] x 600 [D] mm Incomer - 6A FP 10KA MCB- 1 No Outgoing - 3A FP 10 KA MCB - 3 Nos RYB Indication Lamp, Digital Ammeter and digital Voltmeter Make- HENSEL/ESSEL
All as per item No. 16 hereinbefore but with Panel Details Size - 800 [L] x 1435[H] x 620 [D] mm Incomer - 25A FP 16KA MCCB- 1 No Outgoing - 16A FP 16 KA MCCB - 2 Nos 6A FP 10 KA MCB - 1 No 3A FP 10 KA MCB - 1 No RYB Indication Lamp, Digital Ammeter and digital Voltmeter Make- HENSEL/ESSEL
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead of GI strip 25x 4mm by means of galvanized steel bolts, nuts, check nuts and washers and other end connected to Transformer, DG Set, Panel Board etc as directed including funnel, 20mm bore light grade GI watering pipe, wire mesh, common salt and charcoal upto 15 cm all around the earth plate in alternate layers. PCC earth pit in PCC 1:3:6 type C1, 50mm thick precast RCC slab as pit cover casted in PCC 1:2:4 type B1 with 8 mm dia deformed bars as reinforcement @ 15 cm C/C and suitable handle of 10 mm dia MS round bar including earth work and testing etc complete all as specified and shown in electrical plate no-3 of MES schedule part I and directed by Engr-in-charge.
PARKASH ENTERPRISES
M/s Adhikari construction co.
shiv shanker enterprises
Leo Air and Power Solution pvt Ltd.
RUHI ASSOCIATES
M/s GANJOO AND CO
Surjit and Sons
Ridhi engineers and builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .