Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.9 CrAccepted-AOC | ₹2.9 Cr | 1 | Accepted-AOC The bidder quotes value less than put to tender value |
| 2 | 2₹2.9 Cr+₹4.0 L (1.39%)Rejected-AOC | ₹2.9 Cr+₹4.0 L (1.39%) | 2 | Rejected-AOC The bidder quotes value higher than put to tender value |
Tender Value
₹2.9 Cr
EMD Value
₹1.6 L
Closing Date
23 Apr 2024, 4:00 pmClosed
Executive officer
A/M Subramaniya Swamy TempleVallakkottai , Sriperumbudur Taluk , Kancheepuram District .
, Construction Of New marriage Hall to A/M Subramaniya Swamy TempleVallakkottai , Sriperumbudur Taluk , Kancheepuram District .
2024_HRCE_445140_1
2/2024
Open Tender
Civil Works - Buildings
Lump-sum
365 days
Vallakottai
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹1.6 L
Yes
28 May 2025
8 Mar 2024
7 Jun 2024
8 Mar 2024
23 Apr 2024
8 Mar 2024
Amount
Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
Supplying and filling in foundation, basement, etc with filling sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
Cement Concrete 1:5:10 (One cement, Five sand and Ten hard broken stone) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers
Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kg/mᶾ and maximum water cement ratio of 0.50, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.
Foundation and Basement
For Ground floor
For First floor
For Second floor
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
For column footing,plinth beam,bed block templets,staircase steps,piers,raft beam and raft slab etc (for footing-Base Slab)
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
For plane surfaces such as verticalslabs of boxing, vertical drops, facia, vertical walls etc..
Circular column
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
Brick work in following Cement Mortar using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9" x 4-3/8" x 2-3/4" for foundation and basement including curing, etc., complete complying with standard specifiction.
In Cement Mortar 1:5
for foundation and basement
In Cement Mortar 1:6
for ground floor
for first floor
for second floor
Brick partition walls of 11.50cm thickness using best quality II Class Table Moulded Chamber Burnt Bricks of size 9" x 4-3/8" x 2-3/4" in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
for ground floor
for first floor
Plastering with Cement Mortar 1:5 (One Cement and Three Plastering Sand) 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Providing bed concrete of solar tiles based of 50mm thick with PCC 1:2:4 (one part of cement, two part of sand and four part of jelly) using 10-12mm HBS jelly including laying, finishing, curing etc., complete with standard specfication
Supply and fixing the top of roof slab with one course of Fixing Prefinished Solar Radiation Reflective Roofing Tiles (300mmX 300 mmX20mm) with SRI (SOLAR REFRACTIVE INDEX > 85. SOLAR REFLECTION > 0.73 AND INITIAL Emittance > 0.85 as per the BEE standard on top of waterproofing system, laid to the uniform gap of 5-6mm between each tile on 20mm thick cement base mortar in the ratio 1:4 (1 cement: 4m-sand) with thick cement slurry coat and grouting the joints with Grout-Non shrink, free flow Non metallic tile joint grout by adding 15-20% water to form a smooth paste which should be applied to the joints, preferably with a rubber squeeze, allowing grouted material to dry max 30 min.Once the grout has hardened, the tiles will be left with a slight haze on them. Clean it up by going over the area lightly with a damp cloth, then buff immediately with a dry cloth, including providing skirting up to 114mm height along the parapet walls in the same manner @ 45 degree angle etc., complete in all respects complying with relevant standard specifications and as directed by the departmental officers.
Paving the floor with best quality Vitrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Supplying and flooring with following joint free rectified glossy ceramic tiles of size 305 x 305 x 8 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three crushed stone Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
Paving the floor with Kota stone slab of size 600 X 600 of 18 / 20mm ( un-polished )in all floors laid in of cement mortar 1:3 ( One cement Three sand ) , 20mm thick and pointed with colour cement neatly including polishing with polishing stone and oxalic acid etc., so as to perfectly smooth and glossy and including hire charges for polishing machine and power consumption charges etc. The kota stone slabs and other materials to be used shall be got approved by the Executiceve Engineer conrned before use on work etc., complete as per standard specification.
Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with crushed stone sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings..... such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Enginer before use on works) White glazed European Water Closet with 10 litre capacity PVC flushing tank fixed on to wall
Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
a) Nahani Trap of size 100 x 75mm with stainless steel gratings
b) Supply and fixing CP 2way Bib cock with Health Faucet
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, UPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works.
for 50mm dia
for 40mm dia
for 25mm dia
for 20mm dia
Supplying, laying and jointing CPVC pipes (having working Standard Dimension ratio 11) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The CPVC pipes shall be got approved by Executive Engineer before use on works.
a) 20mm dia
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.
a) 110mm dia
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
Gate valve of size 50mm dia
Gate valve of size 40mm dia
Gate valve of size 25mm dia
Supplying & fixing PVC water tank ( 3 layers ) i/c plumbing work etc complete and as directed by the departmental offficers.
Supplying and painting the walls with two coats of wall putty as instructed by the departmental floors including preparation of surface curing etc. complete in all floors complying standard specifications ( The wall putty shall be got approvel by the Executive Engineer before use of work )
Painting the new walls surface with two coats of approved plastic emulsion over one coat of primer including cost of brushes emulsion paint and labour charges etc., all complete complying with relevant standard specification and as directed by the departmental officer.
Supplying and fixing Stainless steel Sink of size 600mm x 600mm x 200mm with 32mm dia 'B' Class G.I. waste water pipe & 32mm dia C.P. waste coupling.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over one coat of zink chromate priming coat in all floors including cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Supplying and fixing in position best quality and approved make Indian made white glazed earthernware wash hand basin of size 550 x 400mm (without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
FRP door Sutter with FRP door frames made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and solid core FRP shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers.
UPVC Ventilator - Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride)Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided in the louvers.The ventilator should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved before use on work directed by the departmental officers.
Supplying & fixing in position best indian Teak wood fully panelled two leaves door/ shutter with door frame of size 150x100mm, Door shutter size 100x50mm top rail & Styles,bottom rail 150x50mm,225 x 50 lock rail 100x50 mm intermediate rail panels for each shutter, with Teak wood panels of 25 mm thickness, frame and fixed wall in concrete M20 grade and includes furniture fittings such as Brass heavy duty butt hinges - 125 x 30mm - 6nos, Brass tower bolt - 400x12mm - 2nos, 150x12mm - 1 no. Brass heavy aldrop 300 x 16mm, Brass door stopper, 50mm rubber bush for shutter.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (sliding) from the profile the size of outer frame 60mm x 58mm and shutter the panels fitted with 4mm thick plain glass with necessary accessories such as rubber beedings, best quality runner ,lock, wheel, handle etc., profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm and two track channel section of 60mm x 45mm for bottom size and top with sliding arrangements to drain the water entering and the window shutter made out of section of size 40mm x 40mm . The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
Manufacturing, supplying and fixing of steel doors with the following specification M.S angles of a size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32x6mm M.S. flat is provided at required intervals in the shutter frames 18 gauge C.R. sheet is laid as panel in the shutter and welded intact for 1/3 bottom portion of the shutter. M.S. flat 18x5mm is welded over the 32x6mm M.S. flat sandwitching the CR sheet in between. Additional stiffener with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. The balance 2/3 portion at top is provided with grill at an average weight of 20kg/sq.m and 6 Nos hinges for double leaves shutter to be provided 6nos of holdfasts 120mm in length made of angle section spliced at the ends are welded to the outer frame of the door. Tower bolts 2nos. one at top and the other at the bottom arte provided one aldrop is provided at on appropriate place in the door. A Tie bar is provided at the bottom of the outer frame to prevent twisting of frame during transportation or fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of all meterials, labour charges, taxes, transportation to site of work, loading, unloading and all other incidental charges etc., complete.
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
110mm dia PVC soil / waste pipe (H150m+v50m)
75mm dia PVC soil / waste pipe (H150m+v50m)
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
PVC pipe 110mm
PVC Elbow with Door
PVC Elbow
PVC "Y" with Single Door
PVC Cowl
PVC coupler / Tee with Door
PVC Bend
PVC PIPE 75mm
PVC Elbow with Door
PVC Elbow
PVC "Y" with Single Door
PVC Cowl
PVC coupler / Tee with Door
PVC Bend
Supplying and fixing UPVC specials in the water supply connection pipe lines as instructed by the departmental officers
50mm dia
Upvc Tee
Upvc Elbow
Upvc Coupler
Reducer Elbow 50 mm x 40 mm
40mm dia
Upvc Tee
Upvc Elbow
Upvc Coupler
Reducer Tee 40 mm x 32 mm
25mm dia
Upvc Tee
Upvc Elbow
Upvc Coupler
Reducer Elbow 25 mm x 20 mm
Reducer Tee 25 mm x 15 mm
Supplying and fixing solid core flush shutter of nominal thick of 35 mm with necessary T.W. internal lipping conforming to IS 2302 with both sides alround commercial ply 35mm thickand furniture fittings such as 1no .200x12mm aluminium tower bolt 2nos. 150x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 3 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., Including Labour wrought and put up in position Shutters for panelled doors including labour charges for fixing furniture fittings complying with standard drawings and standard specification.
Stainless Steel (Salem Stainless Steel) Door Frame (Box Section using Stainless Steel Plate of 1.6mm thick) of size 100mm x 60mm with a rebate of 30 / 35mm x 15mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel hold fast etc.,
Providing polymer coating (waterproof coating) for sunken portion of toilet and terrace floor with following specification on the surface shall be cleaned to remove all dust foreign metals loose materials or any of the deposits of contamination by rubbing with wire brush. Celebrity dry blend and the polymer liquid blend shall be mixed into a desired ratio as per the recommendation of the supplier. The mix shall be stored thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on both clean surface. After drying, second coat shall be applied on the first code as directed by the departmental officers etcetera. The rate inclusive of cost of materials and labels, etc complete.
Supplying and fixing in position of stainless steel hand rails with Balustarder for stair case with top hand railing pipe of 50-80 mm dia with 40mm vertical post at 1000mm interval to a height of 900 mm with horizontal support fabrication pipes of 38.30 mm dia - 2 line, pipe design with 12 mm dia pipe connecting two vertical and bottom horizontal pipes and fixing 100 mm dia ring with 12 mm dia base cup for every vertical post all stain less steel pipes are 1.60 mm thick pipe, 304G to be fixed and fabrication with gas tungsten arc welding, fixing with lock fix paste and cleaning with passivation paste to remove the welding film with fine polishing including drilling the tiles or granite including conveyance, loading unloading etc all complete complying with relevant standard specification and as directed by the departmental officers.(The quality of all the materials should be got approved before use on works)
Construction of inspection chamber of size 60 cm x 60 cm x 60 cm with 75mm thick RCC loose slabs covering in C.M. 1:2:4 mix including necessary reinforcement and earth work excavation for foundation wth 23 cm thick concrete bed using 40mm B.J. concrete in CC 1:4:10 for foundation brick work in CM 1:6 for chamber as directed during the execution including plastering with CM 1:3, 12mm thick, benching and channelly etc complete for 1 No.
Drilling of 140/150mm dia bore well in sedimentary or Alluival Soil strated by first taking a pilot bore of 140mm/150 dia nd then enlarged to the required dia by direct or Rotar mud circulation method using contractor power rotory ( VI z ) Tools labour for drilling and water transportations of machince from one place to another place of half to drilling site and piont ot point in various palces as directed by the engineer in charge.
Up to 60m Depth
Reaming from 140/150mm pilot bore to 300mm dia bore as directed by the TWAD size bore as directed by the TWAD Board officers upto 60m Depth ending from ground level..
Up to 60m Depth
Supply of 160 mm PVC Special Blue casing pipe of best approved quality etc complete as directed by the departmental officers. The pipe should got approved by the Executive Engineer before use on works.
160 mm PVC plain casing pipe
Supply of 160 mm PVC Special Blue Slotted casing pipe of best approved quality etc complete as directed by the departmental officers. The pipe should got approved by the Executive Engineer before use on works.
160mm PVC plain casing ribbed screen pipe
Labour charges for inserting the casing pipes ( with and without) slots in the drilling holes incluidng jointing the pipes with PVC coupling with cement paste etc.,
160mm PVC plain and ribbed screen pipe
Charges for developing the borewell with Air Compressor of 300 CFM capacity ( Minimum 8 hours) including transportation labour and fuel charges for compressor as directed by TWAD bd. Officers and conducting yield test by "V" Notch methods.
Supplying fixing of 2HP Submersible 3 phase motor with all accessries like Auto start panel board ,cable including erection charges etc complete complying with standard specification and as directed by the departmental officers
Supplying, Fixing and connecting of 2x32 sq.mm seathed cable wire for the sub-mergible motor from pannel board to sub-mergible pump.
Supplying and fixing 32mm dia HDPE pipe for sub-mergible pump in Bore well (class-5 1 MPa or 10 Kg / cm2 pressure) of best approved quality including welding wherever necessary etc., complete as directed by the Executive Engineer. The pipe should be got approved by the Executive Engineer before use on works.
Wiring with 2 x 1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module Gl switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point/ fan point (for electronic regulator) (5 points/Coil) Higher End
Wiring with 3 * 1.5 sq.mm. (22/03) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module Gl switch box in flush with wall with 6A two way module switch with module front plate with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End
Supply and fixing of 4' 20W crystal slab LED tube light fittings completed TW round blocks on wall or ceiling with connection with PVC unsheathed copper leads for terminals to the fitting
Supply and fixing of 24W LED 2 * 2 square type Recessed fitting with LED (Higher end) on false Celling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting
Supply and fixing of 100 w LED flood light with integrated driverwith special clamp with PVC and unsheathed copper leads from the terminals to the fitting with LED bulb make Philips or Crompton
Supply and Fixing 450 18" wall with pillar clamp 1 x1/2 * 1 / 4 m.s plate with bolt and nuts for fixing the fan on pillar on wall with almonard for necessary connection Higher and like
supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Lower end) with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18")
Supply and fixing of 300mm (12") sweep (Heavy duty) AC exhaust fan complete without provision of hole in the wall
Supply and fixing of louvers shutters arrangements for 300mm (12") sweep (light duty) AC exhaust fan
supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia Gl pipe (class B) with 1 no 32 mm Gl band complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting
Supply and fixing of 2nos 6A two module 5 pin socket, 2 nos 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections Higher End
Supply and fixing of 2 nos.6/16A two module socket 2 nos. 16A one module switch with module cover plate (plastic) on suitable module concealed Box ( GI ) in flush with wall with connections. Lower End
Supply and fixing of 20A DP plug and socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For AC Plug)
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no 32A DP MCB switch as incoming and 6 nos 6A to 32A SP MCB as outgoing in flush with wall with earth connection only Higher End
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no 32A DP MCB switch as incoming and 10 nos 6A to 32A SP MCB as outgoing in flush with wall with earth conection only Higher End
Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40A 4P MCB Isolator as incoming and 12 nos 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 12 nos 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
Supply and Run of 2 of 2.5 sq mm (36/0.3) PVC Insulated SC unsheathed copper conductor o 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sqmm PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour
Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour
Supply and Run of 2 of 6 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour
Supply and Run of 4 of 6 sq.mm. (84/0.3) PVC Insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm PVC Insulated SC unsheathed copper wire with painting of suitable colour
Supply and Run of 4 of 10 sq.mm. (140/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.
Supply and fixng of TNEB meter board suitable for 3 phase 200A service connection made up of suitable angle iron frame work of size 3 feet x 2feet using angle iron of size 1 -1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet ofsize 3 feet x 2 feet of 12mm thickness withnecessary bolts and nuts supports and supply andfixing of 3 Nos 200A fuse units (500V), 1 No.neutral link, copper earth flat of size 1" x 1/4" withinter connection of EB meter to fuse units by19/16 PVC insulated copper wire with earthconnection complete
Supply and fixing of 250 A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with earth connection only.
Supply and fixing of 200 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with PWD earthing.
Supply and erection of 1 No. 200 Amps floor mounted cubical panel board fabrication out of 14 SWG sheet steel, dust and vermin proof, suitable for operation on 440V, 3 phases, 50Hz AC supply with bus bar chamber comprising of 4Nos. 1" x 1/4 copper flats for RYB and neutral with 2 Nos. 1" x 1/8 copper flat for earth bus to be provided at the cubical. The following cubical TPN switch with fuse and neutral link. 200A FP MCCB -1no's(L&T/Siemens) incoming and 100A FP MCCB - 4Nos (L&T/Siemens) 63A TPN MCCB(L&T/Siemens) Multifunction meter -4 Nos 1no The main switches to be interconnected with the bus bar with suitable rigid tinned copper with necessary hylum sheet separators between bus bars, main switch etc and with double earth connection of the main switches. The panel board!to be painted powder coating with stencil marking of the main switches etc with name, capacity,cable size etc.The capacity of the MCCB size of incoming and outgoing cable the place to which the supply is fed should be mounted on switch chamber. The panel board should be mounted on 100mmx 50mmx MS channel provided all around the bottom of the panel. The whole arrangement should be erection of an angle iron frame pedestal to be constructed with suitable foundation bolts and nuts such that the lowest switch handle is at a height of 1.0 m from the ground level and with necessary earth connection. (Main Panel)
Supply and Laying of 3 1/2 * 150 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and clamping of 31/2 * 150 sq.mm. PVC- LTUG armoured cable on post or on wall with MSclamps
Supply and fixing of brass cable gland for 3 - 1/2 * x 150 sq.mm. PVC armoured LTUG cable with earth connection
Supply and providing cable end termination of 3- 1/2 x 150 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete Supply and providing cable end termination of 3 - 1/2 * 150 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete
Earthing as per the ISI specification with an earth electrode of 2.10 metre Clasy 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry
Supply and run of 25mmx3mm copper flat with with screws on wall / floor for earth connection Lift earth (Lift)
Supply of lubricating oil and first charging of Starting battery and supply of 100 Ltrs for 82.5 KVA diesel to run the Gen set for minimum of 8 hours diesel to run the Gen set for minimum of 8 hours
Civil work for 82 5KVA DG 1 no Area Size 6Mtr x 4 Mtr reactangle shape pedestal RCC concrete height 1.5 mtr from ground level and including Brick arrangement and Plastering Work (MR)
Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 14 SWG TC wire with painting of suitable colour.
Supply and fixing of 2 way MCB sheet stee enclosure metal box with 1 No 40A DP MCB im flush with wall with earth connection only. (Street Light, Motor & UPS 4 Nos)
Supply and erection of 5 star rating 1.5TR Capacity Hi-wall mounting split air conditioner with copper coil confirming to ISN 1391 (part2) 1992 with amendment No. 1 except power consumption (norms) with fixed hermetically sealing compressor operation R22 non CFC for wall mounting with minimum power consumption suitable for operation on 230volt, 50HZ AC power supply complete performing following functions 1. Cooling 2. Dehumidifying 3 Air circulating 4 Filtering (Make Blue star / carrier media / voltas /(or) Equ)
Supply and fixing of 4KVA wall mounting type Automatic voltage stabilizer with time delay arrangements suitable for operation on 230v 50c/s AC supply. (Make. V-guard)
Supply and fixing of condenser iron stand suitable for 2.0TR/1.5TR split type AC units.
Supply and laying of 5/8" & 3/8" dia additional Copper pipe along with 2.5sqmm 3core power cord wire with insulation etc.
Preparation of Electrical schematic diagram, site plans, physical layout 5 copies and payment of CEIG fees submission of completion report, rectification report, obtaining drawing approval, safety certification etc..
Sub Total
Ramana Constructions
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_530078.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .