| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.4 L+₹7.7 L (26.1%)Rejected-Finance HN 2 PREETI NAGAR PHASE II FAIZULLAGANJ LUCKNOW UTTAR PRADESH 226020 | LUCKNOW | UTTAR PRADESH | 226020 | L2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | L3₹38.7 L+₹9.1 L (30.6%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | L4₹40.4 L+₹10.7 L (36.2%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L4 | Rejected-Finance Not Being Lowest Bidder | |
| 5 | L5₹43.6 L+₹14.0 L (47.1%)Rejected-Finance T 3 HILL CREST APARTMENT BEHIND AMBABAI TEMPLE VASCO DA GAMA GOA 403 802 | VASCO DA GAMA | SOUTH GOA | GOA | 403802 | L5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
1 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT OF LT DISTRIBUTION NETWORK SYSTEM WITH ALLIED WORKS AT CH (CC) IN THE AREA OF AGE E/M (HOSP) UNDER GE E/M LUCKNOW
2021_MES_479497_1
GE/EM/LKO/HOSP/T-46 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
Class D or above category b (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹96,000
Yes
13 Nov 2021
4 Oct 2021
3 Nov 2021
4 Oct 2021
1 Nov 2021
20 Oct 2021
60 days
Amount
Supplying and laying or fixing in replacement, jointing and testing LT under ground electric power cable crossed linked polyethylene (XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed by Engineer-in- Charge. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
All as per item No 1 above but of size 10 Sqmm 4 core
All as per item No 1 above but of size 16 Sqmm 4 core
All as per item No 1 above but of size 25 Sqmm 3.5 core
All as per item No 1 above but of size 50 Sqmm 3.5 core
All as per item No 1 above but of size 95 Sqmm 3.5 core
All as per item No 1 above but of size150 Sqmm 3.5 core
All as per item No 1 above but of size185 Sqmm 3.5 core
All as per item No 1 above but of size240 Sqmm 3.5 core
S&F GI Pipes galvanized, “light grade ”, laid in trench complete including fittings 80 mm dia.protection for LT Cable complete all as specified and directed by Engineer-in- Charge.
S&F GI Pipes galvanized, “light grade ”, laid in trench complete including fittings 50 mm dia.protection for LT Cable complete all as specified and directed by Engineer-in- Charge.
S&F GI Pipes galvanized, “light grade ”, laid in trench/or fixed on pole complete including fittings 40 mm dia.protection for LT Cable complete all as specified and directed by Engineer-in- Charge.
M&L for PCC 1:2:4 type B0 12.5 mm graded agregrate as in foundation in coping in foundation of pole including necessary form work complete all as specified and directed by Engineer-in- Charge.
M& L for fabrication and fixing canopy headed junction box suitable for LT Pole made out 3.15 mm MS sheet of size 30x25x15 cm with cover ,04 nos aluminium bus bar of size 25x3 mm for phase and neutral 01 nos 06 Amps MCB SP mounting channel for control street light cable gland aluminium lug MS FIixing clamp -02 nos with nut bolt washer painting with two coat of synthectic enamel paint over a coat of red oxide primer on external and internal surface complete all as specified and directed by Engineer-in- Charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed by Engineer-in- Charge.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed by Engineer-in- Charge.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in- Charge.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified and directed by Engineer-in- Charge. Note :- Punned thickness shall only be considered for payment
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified and directed by Engineer-in- Charge.
Supply, fixing, connecting and testing energy efficient LED bollard light of 18 Watt including foundation work with PCC as required complete all as specified and directed by Engineer-in- Charge. Make philips CAt part No .BCP150 LED150/WWPSU220-240V 7043
Supply, fixing, connecting and testing energy efficient LED Garden landscape view LANTERN WITH SYMMETRIC LIGHT DISTRIBITION AND LIMITED UPWARD LIGHT COMPONENT light of 18 Watt complete all as specified and directed by Engineer-in- Charge. Make philips CAt part No .BGP161 LED2500/NW PSU 220-240 V 7043 IN
Material & Labour for preparation of old painted surface of steel tubular pole 9 meter long above coping) and applying two coat of aluminium paint, making of strip of 20 cm width (BLACK and white in alternate band) upto 1400 mm height with one synthetic enamel paint , rewriting pole No by painter with enamel paint, and painting the existing MS clamp with one coat of aluminum paint complete all as specified and directed by Engineer-in- Charge.
Material and labour for writting of Pole Nos on existing pole with stencil out with white colour in BLACK background of 80 mm hight around the radius of pole and complete all as specified and directed by Engineer-in- Charge.
M&L for Spray painting of LT pannel off size structure including cross arms,chanel etc complete structure after scraping old paint with two coats synthetic aluminium paint after applying one coat of zinc oxide primer complete all as specified and directed by Engineer-in- Charge.
MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting of capacity 100 AMPS complete all as specified and directed by Engineer-in- Charge.
MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 125 AMPS complete all as specified and directed by Engineer-in- Charge.
MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 160 AMPS complete all as specified and directed by Engineer-in- Charge.
MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 200 AMPS complete all as specified and directed by Engineer-in- Charge.
MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 250 AMPS complete all as specified and directed by Engineer-in- Charge.
MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 400 AMPS complete all as specified and directed by Engineer-in- Charge.
Power contactor 4 pole Type Mcx 32 , Fr size 2 rating AC 1 rating 160 A, 50HZ including dismantling the unserviceable contactor, complete all as specified and directed by Engineer-in- Charge.
Power contactor 4 pole Type Mcx 23 , Fr size 1 rating AC 1 rating 40A, 50HZ including dismantling the unserviceable contactor, complete all as specified and directed by Engineer-in- Charge.
Supply & fixing in replacement MCCB Four Pole 630 Amp,36 kA, 415 volts 'B' curve complete all as specified and directed by Engineer-in- Charge.
S & F Offload change over switch, 200 Amps, 415 volts, 4 pole in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all as specified and directed by Engineer-in- Charge. Make havells cat part no . IHBFFE0200 or eqvlnt make as per PS
S & F On load change over switch, 63 Amps, 415 volts, 4 pole side handle type in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all as specified and directed by Engineer-in- Charge. Make havells cat part no. IHBFFE0063
S&F Off load change over switch (side operated handle) 400 Amps, 415 volts 4 pole in sheet metal enclosure with interlock door and pad lock facility including dismantling of existing change over switch, complete all as specified and directed by Engineer-in- Charge. Make havells cat part no IHBFFE0400.
S & F street light panel single phase up to 6 kw load with Astronomical digital timer and MCCB of capacity 32 / TP and SPN 40 Amps fixed on wall/pole with clamps,nut bolts complete all as specified and directed by Engineer-in- Charge. Make havells Cat part no. IHXSS0106A or eqvlcnt make as per PS
Restreching only existing LT OH lines consisting following lines of ACSR and GI wire , any size and tightening with aluminium binding wire 4 Lines of ACSR and 1 line of GI wire complete all as specified and directed by Engineer-in- Charge. Note :- (i) Linear length centre to centre of the poles shall only be measured (ii) Cleaning / pruning of tree branches falling around the conductor shall also deemed to be included in the quoted rates
Supplying and fixing in repair flat twin core ,1.5 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified and directed by Engineer-in- Charge.
Supplying and fixing in repair flat twin core ,2.5 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified and directed by Engineer-in- Charge.
Supplying and fixing in repair flat twin core ,6 sqmm nominal cross sectional area multistranded aluminium conductor FRLS cable, PVC insulated and sheathed 1100 Volts grade complete all as specified and directed by Engineer-in- Charge.
S&F Straight through joints (Heat Shrink Kits) 3.5 core cable 25 to 50 Sq mm for LT underground cable indoor/outdoor type complete for Armoured ,PVC sheathed Aluminium conductor cables Including excavating earth, identifying the fault, making proper joint of cable after rectification & returning soil back to earth, complete all as specified and directed by Engineer-in- Charge.
All as per item No 44 above but 3.5 core cable 70 to 150 Sq mm
All as per item No 44 above but 185 sqmm to 300 sqmm 3.5 core
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed by Engineer-in- Charge. Note -Old pole will be deposited in MES store yard
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply, installation, testing and commissioning of Polycrystaline Photovoltaic Module of 315Wp each.The PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards. Crystalline Silicon Solar Cell Modules IEC 61215. In addition, the modules must conform to IEC 61730 Part-1 - requirements for construction & Part-2 requirements for testing, for safety qualification or equivalent IS. I-V curve of module at STC should be provided by bidder.The total solar PV array capacity should not be less than allocated capacity (kWp).The module frame shall be made of corrosion resistant materials silver anodized aluminium alloy.The bidder shall carefully design & accommodate requisite numbers of the modules to achieve the rated power. The module junction box should not be less than IP67 protection.The manufacturer should warrant the Solar Module(s) to be free from the defects and/or failures specified below for a period not less than ten(10) years from the date of sale to the original customer. The make of Solar PV modules should be : TATA/Havells/Panasonic or equivalent as approved by GE.
S & F cast Aluminum extra heavy pole designer leg and broader designer base finished with polyurethane paint (with proper treatment) daimeter of one leg is 88 mm outer dia for spigot entry 75 mm 03 nos T shaped bolts with nuts & washer provided for concrete foundation . Total length of the pole incl base and legs (base with plate X04 nos Legs) is 3100 mm 10 feet 2 inch ) complete all as specified and directed by Engineer-in- Charge. Make :- Mepro Cat Part No - MCPL 10
S & F fully cast Aluminum finished with polyurethane paint (with proper treatment) hexagonal junction box with maximum projection breath of 575 mm suitable for two number post top lanterns for 02 meter and 2.5 pole, complete all as specified and directed by Engineer-in- Charge. Make :- Mepro Cat Part No - CDPB 02
S & F fully cast Aluminum finished with polyurethane paint (with proper treatment) with acryclic window cover. Total lenght 933 mm (36.75 inch) & max breath 323 mm (12.75 inch) including B22 brass holder provided with aluminum cover and spigot entry 78/90 mm ans suitable for 30to 50 watt LED bulb, complete all as specified and directed by Engineer-in- Charge. Make :- Mepro Cat Part No - CDPB 05
S & F fully cast Aluminum finished with polyurethane paint (with proper treatment) squire junction with maximum projection breath of 625 mm suitable for two number post top lanterns for 2.5 meter and 3.0 Pole, complete all as specified and directed by Engineer-in- Charge. Make :- Mepro Cat Part No - PTL 1500
M & Labour for tracing out LT Cable fault of any size any Location in the area of the AGE E/M hospital by cable fault fault locater Machine and mark location , Excavation for Joints and refilling removal complete all as specified and directed by Engineer-in- Charge. Note - Joint Will be measure and paid respective Item.
Supply and fixing (in Rep) Integral dome type white coloure plastic boty of size 300 mm suitable for fixing on 80 mm pipe post top lanterns including suitable for 1x25 W CFL including making connections complete all as specified and directed by Engineer-in- Charge. Make- Havells Philips/Bajaj/CG.
Ajanta Associates
M/S AMARJIT SINGH
Unnati Engineers
U K Enterprises
M/s Vatsh Raj and co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .