RequiredExperience with Government
RequiredAnnual Turnover
RequiredOEM Authorization Certificate Bid to RA enabled No High Mast Pole With LED Flood Lighting System ( 6 pieces ) ( Under PAC ) Make halonix Model halonix16meterhighmastpolewith90wledlights8n oswithinstallationwork Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) 1/10 GENERIC Highmast with LED Luminaires contains High mast pole
RequiredLED flood light luminaire
RequiredDistribution box
RequiredMCB
RequiredPower cable
RequiredWiring
RequiredEarthing road and wire
RequiredMounting brackets and other suitable accessories as applicable Yes * Installation and commissioning (Installation and commissioning work at multiple locations shall follow as per the guidelines of State/Central Govt.
Requiredrules and regulations as applicable Yes. Including Civil work at site Yes. Including Civil work at site Onsite warranty (in Years) 5 5 POLE Tubular steel poles shall be conforming to IS 2713/80(Part-1& 2) with amdt No-1 latest * ISI Marked No No ISI Marekd if "Yes" BIS License Number (CM/L Number) - Must declare (If No write NA) NA * Length of Tubular steel poles (in Metre) 16 (with 2 nos.of Air Aviation Obstruction LED) 16 (with 2 nos.of Air Aviation Obstruction LED) Type of steel poles Swaged (SP) Swaged (SP) Designation of Tubular steel poles as per table 2 of IS 2713/80 Part-2 with amdt No 1 410SP-10 410SP-10 Earthing arrangement as per Cl.14.1 of IS:2713:1980 Part 1 latest Yes Yes Coating on the tubular steel poles (for entire length) Galvanised min. Mass of Zinc coating 360 Gms. sq. Mtr.
RequiredGalvanised min. Mass of Zinc coating 360 Gms. sq. Mtr.
RequiredGrade of steel tube
Requiredas per IS:1161/1998 Yst 240 Yst 240 Availability of Type Yes * 2/10 Test Reports of the product from Central Govt/NABL/ILAC accredited Lab showing compliance to the specification (as per IS:2713:1980 Part 1
RequiredPart 2 latest). LED FLOOD LIGHT LUMINAIRE No. of Luminaires per pole 8 Nos./pole 8 Nos./pole LED Luminaire conformity to IS:10322/Part 5/Section 5/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes * Photo biological safety of LEDs used shall be as per IS:16108/2012 (exempt group) Yes * Types of LED Luminaire as per the IS: 16107(Part-2 Sec.-1)/2012 Type B * Types of LED Modules as per the IS: 16103(Part-2)/2012 Type 3 * LED Rating/System Wattage/Rated Power 90W 90W Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt * Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest IP66 IP66 Mounting brackets (included) Adjustable * Input operating Voltage range and frequency 90 to 300 V olts AC at 50 Hz+/-2 Hz
Required90 to 300 V olts AC at 50 Hz+/-2 Hz
RequiredAutomatic Higher Cut off voltage above 300 volt Yes * Rated voltage 230 V AC 50 Hz * AC Power Factor at full load ≥ 0.95 * Driver Efficiency (in %age) ≥85 * 3/10 Total Harmonics Distortion (in %age) ≤ 10 * The total circuit power shall not be more than 110 percent of the value declared by the manufacturer" Yes * LED chip Efficacy ≥130 Lm/Watt * Colour temperature (+/-500K) 6000K 6000K Working life for LED (Minimum 50
Required000 burning hours as per LM-80 report) Yes * Colour Rendering Index(CRI) ≥70 * Beam Angle ≥120 * Optic lense materal (UV stabilised) (Write NA for without optic lense supply) Poly carbonate lense Poly carbonate lense Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes * Capacitor shall be rated for a temperature of 105 deg. celsius or better Yes * Junction temperature < 85 degC * Operating temperature range -20 deg C to +50 deg C
Required-20 deg C to +50 deg C
RequiredOperating Humidity Range 10 % to 95% RH * Short circuit Protection Yes * Over load protecton Yes * Over Voltage protection Yes * Reverse polarity Yes * High voltage test (1.5 KV for one minute between supply terminals and body of the unit) Yes * Insulation resistance between earth and current carrying part >100 M ohm * 4/10 The luminaire shall be protected against surges and transients ( Internal) >/=5KV >/=5KV The luminaire shall be protected against surges and transients of >/=10KV (External) Yes Yes The Luminaires casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity Yes * The luminaire body must be corrosion resistant epoxy powder coated Yes * All fastners must be of stainless steel Yes * The entire housing (both LED section and driver section) shall be dust and water proof having IP 66 protection as per IS:10322 (Part 1):1982 latest Yes * Extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the entry of the dust
Requiredwater
Requiredinsects etc.
RequiredYes * Luminaries light transparency should be of Toughened glass Yes * Toughned transparent glass cover thickness >/=4 mm * Toughned Glass shall not get discoloured shall not suffer degration due to heat and ageing within warranty period Yes * Number of electronic control gear per 1 1 5/10 luminaire (power supplies) (in Numbers) Driver components shall be industrial grade or above Yes * PCB shall be FR4 grade minimum 0.8 to 1.0 mm thick or more Yes * The Luminaires works on single phase three wires system (Phase
RequiredNeutral and Earth) Yes * Suitable connector shall be provided for LED connection between driver output and LED Yes * Length of ISI marked three core wire (shall be provided along with supply of material) 50 cm 50 cm Light Source SMD LED Chip as per LM 80/IS16106 * Manufactures Name and and brand on the aluminium die cast body Engraved/Embossed * Manufacturer’s name
Requiredmodel number
Requiredserial number Yes * Date of manufacture (month-year)
Requiredand lot number as identification mark inside each unit and the outside of each packaging box Yes * The operation characteristics voltage and power be marked inside of each LED luminaire unit Yes * LED Make OSRAM/NICHIA/CREE SAMSUNG/SEOUL LUMILED/PHILIPS EDISON/SYSKA LUMENMAX EVERLIGHT BRIDGELUX NATIONSTAR/REFOND
RequiredOSRAM/NICHIA/CREE SAMSUNG/SEOUL LUMILED/PHILIPS EDISON/SYSKA LUMENMAX EVERLIGHT BRIDGELUX NATIONSTAR/REFOND
Required6/10 System must have EMI/EMC compliance as applicable (Test reports shall be furnish on demand by buyer/consignee) Yes * LM 79 (Photometry) (Ref.IS:16106:2012) report from Central Government lab/NABL/ILAC accrediated lab. Reports shall be furnish on demany by buyer (LM-79 report shall have total lumen output
Requiredpower
RequiredPF
RequiredCurrent in Amps
RequiredCRI & CCT etc.
Required) Yes * LM 80 & TM 21 (Part of LM 80) (Ref. IS:16105:2012) Reports and Photo biological report for LED report from Central Government lab NABL/ILAC accrediated lab. Reports shall be furnish on demany by buyer (LM-80 report shall haveand the Pohoto Biological report of the LED Chip being used in the luminaire) Yes * Availability of test Report from Central Government lab/NABL/ILAC accrediated lab to Indian Standrad IS:10322/part 5/sec-5/2012 and IS 16107 (Part 2/Sec 1) : 2012 Yes * DC or AC supplied electronic control gear for LED Module shall comlpy as per IS:15885 (Part 2/Sec.13) Yes * LED Luminaire for Flood Light shall comply with Complusory Registration(CRS) of BIS for safety as per IS Yes * 7/10 10322 (Part 5/Section 5): 2012 as applicable on the date ACCESSORIES - G I Pipe G.I. Pipe (ISI Marked) for earthing with all accessories per pole shall supplied Yes Yes G.I. Pipe length (in mm) 300 mm 300 mm G.I. Pipe dia 20 mm 20 mm ACCESSORIES - G I Wire ISI marked G.I. wire shall be supplied per pole for earthing Yes Yes G.I. wire dia (in mm) 2.64 mm 2.64 mm G.I. Wire length (in m) 20 20 ACCESSORIES - Power Cable PVC Insulated
Requiredarmoured power cable (ISI marked to IS:1554 Part 1) shall be supply per pole Yes Yes No. of core 3 2
Required3
RequiredNA Cross sectional area of cable (in Sq.mm) 2.5 2.5 Conductor material Aluminium Aluminium Cable category Type C
RequiredC2
RequiredFR-LSH Type C
RequiredC2
RequiredFR-LSH Length (in mtrs.
Required) 25 25 ACCESSORIES - Wiring PVC insulated wiring cable (IS Marked to IS:694) shall be supply per pole Yes Yes No. of core 2 2 Cross sectional area of cable (in Sq.mm) 1.5 1.5
RequiredNA Conductor material (for wiring) Copper Copper Cable category (for wiring) Type C
RequiredFR-LSH Type C
RequiredFR-LSH Cable length (in mtrs.
Required) 20 20 ACCESSORIES - MCB Distribution Board with Switches & Terminals and ISI marked MCB per pole shall be supply with lighting system Yes Yes 8/10 Distribution board for fixing MCB with enclosure protection Yes. Provided with IP 43 Yes. Provided with IP 43 Distribution Board per pole for fixing MCB with enclosure protection IP43 and above Yes. Provided. Yes. Provided. MCB - Rated current (in Ampere) 63.0 A 63.0 A No. of pole 1 Pole 1 Pole Rated Voltage 240 Volt 240 Volt Bracket for each pole : Mounting arrachement including suitable bracket for fixing the Luminaires with each pole. Bracket material shall be MS. Galvanised min. Mass of Zinc coating 360 Gms. sq. Mtr.
RequiredYes Yes CERTIFICATIONS Marking: All the products shall have marking details as per relevant BIS standard Yes * Seller shall furish all the test reports and certificates as per the technical specification to the purchase auhtority on demand Yes * * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.