Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC OLD AIRFIELD ROAD RAWALPORA WANBAL SRINAGAR 190005 J K | SRINAGAR | SRINAGAR | J K | 190005 | ₹1.1 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹1.2 Cr+₹6.7 L (5.96%)Rejected-AOC R O RAWALPORA WANBAL YAIYAL TEH DISTT SRINAGAR J K PIN 190005 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190005 | ₹1.2 Cr+₹6.7 L (5.96%) | L2 | Rejected-AOC L2 bidder |
| 3 | L3₹1.2 Cr+₹6.9 L (6.19%)Rejected-Finance | ₹1.2 Cr+₹6.9 L (6.19%) | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | L4₹1.2 Cr+₹9.4 L (8.39%)Rejected-Finance | ₹1.2 Cr+₹9.4 L (8.39%) | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 5 | L5₹1.3 Cr+₹19.5 L (17.4%)Rejected-Finance 01 DUDWAN KUPWARA DUDWAN KUPWARA JAMMU KASHMIR 193222 UDYAM JK 12 0031214 | KUPWARA | JAMMU AND KASHMIR | 193222 | ₹1.3 Cr+₹19.5 L (17.4%) | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
25 Dec 2024, 5:00 pmClosed
CWE AF SRINAGAR
CWE AF SRINAGAR
SPECIAL REPAIR TO LIVING AIRMEN BILLETS AT NO 1 AND 2 AREA AT AF STATION SRINAGAR
2024_MES_684641_1
CWE-AF-SRG/SRG-34/2024-25
Open Tender
Civil Works
Item Rate
180 days
AF STN SRINAGAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
GE AF SRINAGAR
₹2.1 L
Yes
11 Mar 2025
20 Nov 2024
27 Dec 2024
20 Nov 2024
25 Dec 2024
11 Dec 2024
Amount
Building Work
Taking down Chowkats or frames with shutters (without taking off shutters from the frames) n exc. 1.5 sqm and credited to the contractor all as specified and directed by Engineer-in-Charge. Note: The damaged portion of the tiles/rendering shall be made good with the same material to match with the adjacent surface.
Taking down Chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sqm but n exc 4 Sqm each and credited to the contractor all as specified and directed by Engineer-in-Charge. Note: The damaged portion of the tiles/rendering shall be made good with the same material to match with the adjacent surface.
Taking down shutters of any description size of shutter exc 1 sqm but not exc 2 sqm and removing from site complete all as specified and directed
S&F 125x60mm size of factory made pressed steel frame for door with one or more rebates including necessary fixing lugs, lock striking plates, hinges, hold fast (40x3mm) etc. complete size /profile of frame as per IS complete all as specified and as directed by the Engineer-in-Charge
M&L for PCC 1:3:6 type C0 (using 12.5 mm graded stone aggregate) as in back filling of pressed steel frame etc complete all as specified and directed.
Material and labour for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in bed blocks for hold fast and as in roof kerb benching & similar work etc complete all as specified and directed
Material and labour for two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer to new steel surface including preparation of surfaces exceeding 10cm with or girth complete all as specified and as directed.
Material and labour for applying one coat of synthetic enamal paint on steel surface of any description over 10cm widht or girth including preparation of old painted surfaces complete all as specified and as directed.
S & F for Factory made 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, in second class hardwood, complete all as specified and directed by Engineer-in-Charge
S & F for Factory made 35mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated in second class hardwood, complete all as specified and directed by Engineer-in-Charge
Material and labour for two coats of synthetic enamel paint over a coat of primer to new wooden surface including preparation of surfaces exceeding 10cm with or girth complete all as specified and as directed.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube and fixing in opening as specified and directed.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel heaving a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet fore tip rail, lock rail & bottom rail on either side and as gap insert fir top rail, lock on either side and as gap insert fir tip rail & bottom raill, paneling of plain colour PVC sheet to be filled in MS frame welded/sealed to the stiles and rails with suitable PVC shet beading and jointing together with solvent cement, supplying & fixing of frame at site all as directed.
S & F for Aluminium alloy, anodised, sliding door bolt 300mm length with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and directed by Engineer-in-Charge.
S & F for 150 mm long Aluminium anodised,handle of extruded section fabricated type anodised and fixed complete all as specified and directed.
S & F for Aluminium, anodised, barrel tower bolts 150mm size of extruded section, complete all as specified and directed by Engineer-in-Charge.
Supply & Fix 125 mm long Aluminium anodised,handle of extruded section fabricated type anodised and fixed complete all as specified and directed.
S & F for Aluminium, anodised, barrel tower bolts 125mm size of extruded section, complete all as specified and directed by Engineer-in-Charge.
S & F for Butt hinges, medium weight, cold rolled mild steel 100mm size, complete all as specified and directed by Engineer-in-Charge.
Floor door stopper of aluminium alloy body 140mm cover plate and tounge, anodised with harde drawn steel spring fixed in floor, complete all as specified and as directed by Engineer-in-Charge.
S&F door strip comprising of aluminium holds & rubber strip fixed at bottom of door shutter with screws, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Box type steel window double frame (glazed & gauged) made of ERW tube P- section of size 60 mm x 25 mm double rebated outer frame comprise glazed skelton shutter door frame of ERW tube P-section size 50 mm x 20 mm with two Nos openable leaf cnsisting of two Nos of sash bar of T-sec 20 mm x 3 mm welded to frame with one No vertcale mullion of ERW of ERW box type T-section size of 60 mm x25 mm FI 2 mm thick welded / screwed to frame for fixing of wire guage/glass including fixture and fitting like as handle, tower bolt stopper , cleat, pintal hinges, holdfast primer etc, complete all as specified and directed.(Note- sheet glass,wire mess, security grill will be measered and paidseaperately and window will be measured one side only)
All as per Sl item No 23 here-in-before but single shutter(glazed) with single frame. Complete all as specified and directed
Supply and fixing aluminium powder coated frame section 80x44mm 16 gauge thick for cubical partition but including 5mm thick plain/tinted /heat reflecting glass pan/10mm thick particle board with and necessary jointing cleats rubber beading alumimium powder coated snap beading screws alumimium powder coated flat for fixing etc complete all as specified and directed by Engineer-in-Charge.Note Min thickness of powder coating 50 micron
S & F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed by Engineer-in-Charge.
Material and labour for Anodised aluminium snap grid frame work for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, complete all as specifiedcomplete all as specified and directed by Engineer-in-Charge.
Material and labour for 08 mm thick Non asbestos fibre cement building boards one side aluminium foil coated fixed or laid/ inserted to aluminium frame work with screws including taking down complete all as specified and directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
Supply and fixing for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
Supply and fixing for mild Steel ordinary rat tail rod pattern springs including roller and roller plate complete 300mm length, complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for, Complete all as specified and directed by Engineer-in-Charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work for fair finished surface; not exceeding 200m thick (Horizontal or sloping), complete all as specified and directed by Engineer-in-Charge.
Material and labour for RCC, Type B1 1:2:4 (20 mm graded aggregate) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed by Engineer-in-Charge.
MS TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooking for columns, hooking ends and binding with and including mils steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair drapory rod 25mm dia fency type mild steel plastic coated inculding wooden funnel and wooden brackets, Complete all as specified and directed by Engineer-in-Charge.
Dismantling of Stone slabs and tiles of any description or thickness in floors aprons etc laid in cement mortar of any thicknes, complete all as specified and directed by Engineer-in-Charge.
Material and labour for granite (of any type) work (table rubbed and polished) 20mm thick as in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed in cm 1:4, complete all as specified and directed by Engineer-in-Charge.
Material and labour for machine cut kota stone slab flooring 20-25 mm thick over screed bed or bedding layer 20 mm thick in CM 1:6, and jointed with grey cement slurry mixed with pigment to match the shade of slab incl rubbing & polishing complete all as specified and directed by Engineer-in-Charge.
Material and labour for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with ditto as per item 13014 including backing coat 10mm thick in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Material and labour for 25mm thick cement concrete type B-0 (1:2:4) using 12.5 mm graded stone aggregate as in sub base of floor finish even and rough to receive further floor finishes ( tile/kota stone/ marble ), complete all as specified and directed by Engineer-in-Charge.
Material and labour for Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick Screed bed or bedding layer of mortar for laying floor finishes in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
Material and labour for Coloured Glazed ceramic tiles in vertical surface 600X300x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including Rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as backing coat complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. Complete all as specified and directed by Engineer-in-Charge.
Material and labour for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6, all as specified and directed by Engineer-in-Charge.
Material and labour for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6, Complete all as specified and directed by Engineer-in-Charge.
BLANK
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces and finishing even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material and labour for Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces and finishing even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering 5 mm thick on other than fair faces of concrete surfaces in ceilings in cement mortar 1:3 and finished fair and even without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparing new plastered surfaces and applying two coats of distemper oil emulsion including 3mm thick layer of wall care putty and priming coat preparatory to distempering on surfaces of wall, , complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparing of new surface of plaster and applying three coats of white wash on ceiling complete all as specified and directed by Engineer-in-Charge.
Material and labour for Preparation of newly plastered surfaces, and applying two coat of weather paint (Apex) paint over a coat of exterior primer colour and tint as ordered in any pattern upto 15 metres height including 1mm thick wall care putty on wall sides and soffits of the beams, ceilings, fascias, parapets etc complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel water tubing 15mm bore and connection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for GI tubes 15 mm bore 'medium grade' with all fittings and fixed complete to walls and ceilings or laid in trenches or cutting chases in wall and making good to disturbed portion of wall complete all as specified and directed by Engineer-in-Charge.
Refixing of old steel tubing and connection in new or old position of 15mm bore. complete all as specified and directed.
Taking up or down steel water tubing and connection complete 20 mm bore complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for Steel water tubing galvenised 20mm bore medium grade with all fittings and fixed to walls, ceiling or laid in floor complete all as specified and directed by Engineer-in-Charge.
Refixing old GI tubing and connections, 20 mm dia, in old or new position. (Walls, ceiling, floors, etc.) completed all as specified and directed.
Material and labour for Lagging to pipes 15mm bore used in external water supply or plumbing all around with 50mm thick bonded mineral wool pre-formed ‘SNAP ON’ pipe sections of density 144 Kg /Cum conforming to IS 9842 provided with chicken mesh wire netting 25mm gauge 20mm mesh complete all as specified and directed by Engineer-in-Charge.
Material and labour for Lagging to pipes 20mm bore used in external water supply or plumbing all around with 50mm thick bonded mineral wool pre-formed ‘SNAP ON’ pipe sections of density 144 Kg /Cum conforming to IS 9842 provided with chicken mesh wire netting 25mm gauge 20mm mesh complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair white vitreous China, under counter wash hand basin, oval shape, of size 595 x 420 x 200 mm with all fixing accessories fixed in counter, supply & fix new brackets, 32 mm size brass chromium plated waste coupling, complete, all as specified & directed.
Supply and fixing in PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair PVC waste pipe flexible for WHB of 32mm size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair, Vitreous china squating pan, orissa pattern size 580 x 440mm and making good, including connection to trap, and to flushing pipe, anti-syphonage pipe, etc., including trap set in and including concrete Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs PVC valveless, syphonic action type, flushing cistern , low level 10 ltr capacity, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 15 mm bib tap CP, cast copper alloy with capstain head screwed down screwed for iron pipe or for brass ferrule fancy type, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs CP angle/stop valve of cast copper alloy screwed down high pressure with capstain head screwed both ends for iron pipe or for unions and fixed 15 mm bore complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs CP shower roses with CP Arms, 15mm bore, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs of Shelf of PTMT fixed with and including chromium plated brass screws and wooden/ plastic cleates (minimum weight300gms) complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for Brass chromium plated, tubular towel rails 20 mm dia, D- type, 60 cm long between flanges, completed all as specified and directed.
Supply and fixing 15mm dia Brass CP wall mixer for mixing hot & cold water fixed in repairs, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair 15mm dia Brass CP central hole basin mixer with 450mm braided connection pipe (without pop-up) for mixing hot & cold water, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs Soap dish, brass CP any type, fixed to plugs with chromium plated brass screws Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs, PVC (SWR) pipes 75mm dia single socketed, in any length with rubber ring joints laid in trenches, floors or fixed to wall, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs, PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints laid in trenches, floors or fixed to wall complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 75mm bore dia PVC floor trap(SWR) plain with grating including jointing with solvent cement to waste pipe complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 75mm bore PVC(SWR) door bends any radius complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 75mm bore PVC (SWR) junction single (Single T) equal or unequal complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 110 mm bore PVC(SWR) door bends any radius provided with access door complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 110mm bore PVC (SWR) junction single (Single T) equal or unequal with access door complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 110mm bore PVC (SWR) 'P’ trap complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 75mm bore PVC (SWR) vent cowl, complete all as specified and directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment of walls and applying thin layer of wall care putty and prepare the smooth surface with sand paper and applying two coats of distemper oil emulsion (OBD) paint over a cot of primer on walls complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of old surfaces of ceiling including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc including cornices, pilasters etc (plastered or unplastered surfaces) and applying one coat of white (lime) wash complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing for 1000 litres capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling water tanks and removing from site including 20 mm Ball brass valves, high pressure, with polythene float and flynut complete all as specified and directed by Engineer-in-Charge.
supply and fixing in repair vitreous china urinal half stall type including all fittings with grating and union for discharge pipe complete including providing and fixing plug bedding urinal against wall in CM 1:2 securing urinal to plug with and including 60mm long brass screws pointing around back in cement complete all a specified
Material and labour for complete removal of existing surface treatment from the old plastered, pointed/concrete surfaces vertical or horizontal including brooming down or steel wire brushing, scrapping down, smoke soot moulds, moss and efflorescent salts and greasy spots and applying two coat of weather paint (Apex) paint over a coat of exterior primer, colour and tint as ordered upto 15 metres height including sides and soffits of the beams, ceilings, fascias, parapets etc, complete all as specified and directed by Engineer-in-Charge.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, Complete all as specified and directed by Engineer-in-Charge.
Material and labour for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded aggregate) as in pavement/plinth protection,plinth protection shall be laid in alternate bays and joints shall be filled with bitumastic gola with 80/25 bitumen (1 part bitumen mixed with 3 part of sand) finishing surface even and smooth without extra cement complete all as specified and as directed.
Demolition of cement / lime concrete from Sunkan portion in ground floors and paving not exc 15cm thickness (below or above ground level) including surface finishes of any type such as Mosaic, terrazo tile/tiles complete all as specified and directed.
Material and labour for mass concerte Type E-2, 1:5:10 using 40mm graded stone aggregate filling in Sunken portion complete all as specified and directed.
Material and labour for cleaning surface of sunken portion taking out existing material wall/bottom and applying cement slurry @1.2 Kg per Sqm and applying 15 mm thick cement plastred in CM 1:3 finished even and fair using extra cement and applying two coat of acrylic polymer modified cementious slurry as per manufactureas instruction to make the surface leak proof complete all as specified and directed.
Material and labour for Rolled mild steel in roof trusses (framed), trussed, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. Fe 410-W (Gde E-250) quality A complete all as specified and directed by Engineer-in-Charge.
Material and labour for structural steel work as in truss,rafter purling, made out of anglle/Hollowpipe/tube section including jointing cleats, plates flat iron , gusset plates, rails, braces etc Fe 410-W (gde-E-250) Quality, confirming to IS-1161-1979 of grade St-240 complete all as specified and as directed.
Material and labour for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings Fe- 290 (Gde E- 165) (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
Disconnecting existing water tanks exc 500 liters and n.exc 1000 liters setting aside(or lowering if reqd ) including ,Material and labour for cleaning and removing all scale,dirt and funges etc. from tanks and mouth of circulating pipes, with suitable cleaning chemical and brushing the wall and bottom of tanks, washing with clean water, writing letter i.e. "TANK CLEANED ON ......................(Date)" not exc. 100mm height with synthetic enamel paint for tanks of capacity 500 ltrs to 1000 ltrs complete all as specified and as directed.
Internal Electric Supply
Taking down carefully (copper/aluminum) unsv point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point ,socket point or power point including fixture and fitting such as switches , ceiling roses, pendants , regulators , sockets , light fitting etc. removing material to store for keeping in safe custody or for taking credit( credit for above items should be made as per conditions seperately) and making good the disturbed surfaces of wall/floor or ceiling to match with existing surface and finishing the surfaces as per existing complete all as specified and directed.
M&L Point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unseathed cable 1100 volt grade in and including concealed, non metalic rigid pvc medium grade ISI marked conduit not less than 20/25 mm with all fittings & other accessories and also including PVC insulated ISI marked unseathed FRLSH cable 1100 volts grade of size 1.5 sq mm copper conductor as earth wire to common earth dolly including concealed in wall/ceiling, modular MS box with modular cover plate with frame suitable for modular switches, sockets, fan regulator etc for the following :- Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green)
(a) One light/ceiling/exhaust fan point controlled by one way switch 5 amps 240 volts
(b) one 3 pin 5 Amps switch socket out let point on independent board
(c) one 3 pin 5 Amps switch socket out let point on same board
M&L Point wiring with 2.5 sq mm copper conductor FR-LSH (multistrand) PVC insulated ISI marked unseathed cable 1100 volt grade in and including concealed/surface , non metalic rigid pvc medium grade ISI marked conduit not less than 20/25 mm with all fittings & other accessories and also including PVC insulated ISI marked unseathed FR-LSH cable 1100 volts grade of size 1.5 sq mm copper conductor as earth wire to common earth dolly including concealed in wall/ceiling, modular MS box with modular cover plate with frame suitable for modular switches, sockets 16 Amps, 240 volts :- Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green)
S&F switch piano flush type single pole one way 6 Amp 240 volt marked light/fan suitable for one module etc complete as specified and directed.Make- Legrand/ Anchor/ Havells or equivalent approved be GE
S&F flush type 6 Amp 5 pin universal socket suitable for two module , 250 volts complete all as specified and directed by Engr-in-charge Make Legrand/ Anchor/ Havells or equivalent approved by GE
S&F switch piano flush type one way 16 Amps 240 volts suitable for one module complete as specified and directed by Engr-in-charge Make- Legrand/ Anchor/ Havells or equivalent approved by GE
S&F piano flush type 6/16 Amp socket suitable for two module, 250 volts complete all as specified and directed by Engr-in-charge Make Legrand/ Anchor/ Havells or equivalent approved by GE
S&F flush step type two module fan regulator suitable for 120 watt 250 volts complete as specified and directed by Engr-in-charge Make- Legrand/ Anchor/ Havells or equivalent approved by GE
M&L for ceiling rose with three terminal as per relevant IS complete as specified and directed Make SSK/havells/legrand /Anchor
Supply and fixing LED integrated batten T5 of 18/20 watt, 4FT.white,.indoor decorative PVC extracted T5 LED batten integrated type complete all asspecified and directed by Engr-in-Charge
Supply and fixing LED integrated batten T5 of 10 watt, 2FT.white,.indoor decorative PVC extracted T5 LED batten integrated type complete all asspecified and directed by Engr-in-Charge
S&F Energy saving new generation 10 W LED IP 65 bulkhead luminair complete as specified and directed by Engr-in-charge Make:- CG C&S ,Havells ,Crompton equivalent approved by GE.
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 4 way TPN (VTP) suitable for MCCB DB's 415 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete all as specified and directed.
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 8 way SPN suitable for MCB DB's 240 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete all as specified and directed
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 12 way SPN suitable for MCB DB's 240 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete all as specified and directed by Engr-in-charge.
S&F MCB single pole and neutral ISI marked ISI Marked `C' series working on 240 Volts 50 HZ AC supply for incomming and out going controlling cercuit of capacity 6-32 Amp breaking capacity 10 KA etc all as specified and directed. Make Legrand cat part No 408587 t0 408595 or equivalent approved by GE
S&F MCB single pole ISI marked ISI Marked `C' series working on 240 Volts 50 HZ AC supply for incomming and out going controlling cercuit of capacity 5-32 Amp breaking capacity 10 KA etc all as specified and directed. Make Legrand or equivalent approved by AO
M&L MCCB 4 pole 125 Amps 25 KA working on 415 Volts 50 HZ AC supply, all as specified and directed.
M&Lfor sub main wiring with two single core, PVC insulated,ISI marked, unsheathed, 1100 volts grade multistranded copper conductor FR-LSH cable drawn into and including suitable size non metalic pvc conduit (ISI marked) concealed/surface with all accessories and including one single core pvc insulated multistranded unsheathed 1100 volts grade copper conductor FR-LSH cable as earth wire of the following size as in repair complete all as directed & specified.
(a ) 2x6.0 sqmm + 1x6.0 sqmm earth wire
(a ) 2x4.0 sqmm + 1x4.0 sqmm earth wire
Disconnecting all water and electric connections of geysers and taking down carefully installed storage type electric geysers of any capacity of any make/type/size (horizontal/vertical) lowering and setting aside opening geysers examining and checking thoroughly for requisite repair/ replacement of defective/worn-out/ unserviceable components/parts materials including preparing inventory for each geyser separately in presence of Engineer-in-Charge and removing all scale and dirt de-scaling of deposited in inner copper tank and outer tank and heating elements by HCL or aqua clear pedilite solution, thermostat, indicator lamp, assemble checking electrical connection, stopping of minor leaking by soldering/brazing of the inner copper tank and replacement of defective worn out unserviceable components/partsand painting of geyser 50 ltrs after scraping, cleaning, knotting and stopping including preparation of surface of geyser and rubbing with emery paper for painting with one coat of duco paint by spray painting mation to achieve glossy finish of approved make first quality and re write MES No. on the body of geyser with black synthetic enamel paint (letters and figures 2cm high ) & re-fixing geyser in its original location including hoisting, connecting to water & electric connection and testing for proper functioning of geysers including earthing to the entire satisfaction of the Engineer-in-Charge including the replacement of the following items etc complete all as specified & directed.
(a) Supply only Fiber reinforced PVC nylon pipe heavy duty size 450 mm long 15mm bore with brass coupling chromium plated with rubber washers as both ends as per IS.-01 Nos (b) Supply only Flexible chromium plated connection pipe size 450 mm long 15 mm bore with brass chromium plates coupling suitable for geyser any capacity-01 Nos
Disconnecting, taking down ceiling fan from existing place and refxing the same after replacement of rubber bush, canopy,capacitor 2.5 ,mfd, clip incl greasing/oiling incl painting one coat of synthetic elament paint after preperation of surface as per specified incl replacement of unserviceable suitable size 3 core copper cable from ceiling rose to connector of fan etc and writing the MES No complete as specified and directed by EIC.
Taking down carefully exhaust fan any sweep and make, dismantling of blades, frame and opening and examining fan motor, cleaning of dust/.dirt of fan, cleaning and greasing of ball bearing and bushes with fresh oil and best quality of grease respectively, including applying synthetic enamel paint to achieve glossy finish approved coloured as directed by Engineer-in-Charge and marking MES No with black paint and reassembling of complete fan and re-fixing in its original location making connection with replacement of rubber real insulator,split pin,nut,bolt, washer, 3 core flexible cable from connector to ceiling rose and testing to the entire satisfaction of Engineer-in-Charge complete.
Earthing complete with galvanised steel earth plate electode 600 mm x 600 mm x 6.00 mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level connected to and including galvanised steel earth lead wire 4 mm dia by means of bolts, nuts, chock, nuts and washers of galvanised iron or steel including PCC Pit in 1:2:4 type B-1 angle iron frame with RCC cover and handle, excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore upto main board complete all as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected to main control board as specified and testing completion complete all as specified and directed. Note: (i) The unit rate includes GI pipe up to 7.5m for protection of earth lead. For any additional length the same shall be adjusted through deviation order. (ii) The unit rate includes main earthing lead/strip from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance is recorded more than 1.0 ohms then the earthing shall be re done by the contractor without any extra cost to the department.
S&F in repair sheet metal enclosure single pole and neutral with 2 pin earth metal plug and socket with one single pole MCB 20 A, 230 volts etc complete as specified and directed
External Electric Supply
Taking out LT under ground old cable of any size from trenches all as specified and directed by Engrr-in-Charge.
Supply, laying, jointing, testing , XLPE insulated and PVC sheathed with stranded aluminium conductor heavy duty, LT cable 1100 volts grade, armoured cable, conforming to IS 1554 Part I / ISI marked, including cable glands , cable lugs etc, to suitable the cable size, cables to be laid in trenches, fixed along the poles bare or through GI pipe laid under floors road etc fixed concealed in walls encased in GI pipe etc complete of sizes 35 Sqmm 3.5 core
Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5m depth and getting out in for foundation of pole,stay,laying of cable and pipe in any type of soil etc all as specified and directed
Returing, filling in incl spreading, levelling, watering and well ramming in layers n exc 25cm thick after laying of the cables,jointing & testing complete all as specified and directed.
Removing excavated material to a distance n.exc 50 m & depositing where directed at a level n. exc 1.50 m above the starting point complete as specified and directed.
M&L for sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of the sand after laying the cable but will be measured 18 cm after punning etc complete as specified and directed.
M&L for laying of bricks well burnt sub class B (old pattern) laid flat for cable protection width equal to the length of bricks complete all as specified and directed
Supply and fixing galvanised iron tube ` light grade' for protection of copper strip at wall and duct/road/trench for 40 mm dia of pipe complete all as specified and directed by EIC
Road Path
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, Complete all as specified and directed by Engineer-in-Charge.
M& L for 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in sub base Complete all
Supply and laying factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required Complete all as specified and direction by Engr-in-Charge.
Material and labour for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment all as specified and directed.
M&L Sand filling under floors or in foundations including watering and consolidation. Complete all as specified and direction by Engr-in-Charge.
Sewage Disposal
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in any type of soil, complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick using excavated soil, complete all as specified and directed by Engineer-in-Charge.
Removal of excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point, complete all as specified and directed by Engineer-in-Charge.
Demolition of Brickwork or stone / boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
Demolition of Precast cast RCC manhole cover of any descreption set in Cement mortar including removal of debries, complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description in any position complete all as specified and directed by Engineer-in-Charge
Taking down cement plaster of any description on brick or stone wall / ceiling etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up 150 mm dia bore salt glazed stone were drain pipe including PCC packing under hunching against the sides of pipe bed and complete PCC bedding and removal of debries all specified and directed.
S&F 150 mm bore, HDPE Double Wall Corrugated Pipe in any length with rubber ring joints, laid in trenches for sewage pipe complete all as specified and as directed by the Engineer-in-Charge.
M&L for Concrete bed to 150 mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:3:6 (Nominal mix) type C-2 using 40mm graded stone aggregate and tested, complete all as specified & directed.
M&L for cutting & removing 150 / 200 mm dia drain pipe from existing manhole and inserting new drain pipe of dia 150 / 200 mm, making good disturbed surface & benching with cement concrete 1:2:4 type B-1, complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius with old size bricks built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
All as per item No 20 above here-in-before but except bricks. Note:- Old brick retrieved vide item No 04 above shall be reused.
M&L for Cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in benching /coping and the like including weathering, slightly rounded or chamfered angles as directed including form work and finishing all exposed surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 15 mm thick on brick masonary wall surfaces in cement mortar 1:4, finished even and smooth without using extra cement including mixing only intergral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified and directed by Engineer-in-Charge.
Supply only liquid water proofing compound of approved manufacturer complete all as specified and directed by Engineer-in-Charge.
M&L for Pre cast RCC 1:2:4 type B1 using 20 mm graded stone aggregates as in cover slab for soakage well / manhole and similar works supported on walls and set in cement mortar 1:4 complete, complete all as specified and directed by Engineer-in-Charge. Note:- Reinforcement steel will be measured & paid separately
M&L for TMT steel bars 6 mm to 08 mm dia in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia all as specified. Complete all as specified and directed by Engineer-in-Charge.
M&L for TMT steel bars 8 mm to 10 mm dia in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia all as specified. Complete all as specified and directed by Engineer-in-Charge.
Supply, installation, testing & commissioning HDPE Septic tank of size 2000 mm dia and 2250 mm height, with 115 mm dia inlet pipe and supply & fix 160 mm dia PVC(SWR) pipe of length 2 m for connecting septic tank to soakage Pit & 50 mm dia vent pipe, fixed in position and connection with inlet, outlet & vent pipe as per manufacturer instruction complete all as specified and directed by Engineer-in-Charge. Make:- Sintex Model No CCST-500-01 or equivalent model No of make Comfert polymers, or make approved by GE. Note:- Excavation, Earthwork and returning filling with sand will be measured & paid separately.
M&L for Soakage well in soft / loose soil, PCC 1:3:6 in foundation, 150 mm thick, wells of Honey combed brick work with Cement Mortar 1:4 with using sub class ‘B’ old size brick, PCC bend using 1:2:4 concrete at every 1.00m Ht, 115mm thickness of brick work should be increased at every 0.75m depth and filling brick bats in the wall upto 2.00 height and provide RCC slab 100mm thick of M-25 grade concrete including intercepting / Screen chamber, complete size 3.50m dia and 4.00m depth (100 users) complete all as specified in TD-CE/AF/STD-15/2000 Sheet No 1/2 and 2/2 dated 05 Jan 2000.
M/S LATIF AHMAD BABA CONSTRUCTION (BID ID -3197388)
M/S Abdul Ahad Rather (BID ID -3191146)
M/S BASHIR AHMAD TANTARY (BID ID -3191936)
M/S WANI AND SONS (BID ID -3191457)
M/S RATHER CONSTRUCTION CO (BID ID -3198369)
M/S LATIF AHMED MIR (BID ID -3193833)
M/S SUHEEL CONSTRUCTIONS (BID ID -3192587)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .