Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹7.5 L+₹56,000 (8.13%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹12.5 L+₹5.6 L (81.4%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹8.9 L
EMD Value
₹17,800
Closing Date
13 Jul 2023, 6:00 pmClosed
Chief Engineer Pathankot Zone
Chief Engineer Pathankot Zone
CONSULTANCY SERVICES FOR PROVISION OF PACKAGE TYPE SEWAGE TREATMENT PLANT FOR VARIOUS POCKETS IN RATNUCHAK UNDER GE KALUCHAK
2023_MES_602880_1
CEPZ-08/2023-24
Open Tender
Civil Works
Item Rate
90 days
GE Kaluchak
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Kaluchak
₹17,800
12 Sept 2023
13 Jun 2023
20 Jul 2023
13 Jun 2023
13 Jul 2023
28 Jun 2023
Amount
Consultancy services for preparation and submission of Detailed Project Report (DPR) for Consultancy Services for Provn of Package Type Sewage Treatment Plant and upgradation of sewer line at Ratnuchak (UT J&K) in two pockets complete all as specified including following brief scope of work as elaborated under serial No 1.01 to 1.08 here-in-after:-
Detailed topographical survey of area (Approx 180 Acre) over two locations as directed by GE/Engineer in charge. Topography map to show/superimpose the existing ground features like buildings, roads, Nallahas, rivers and other similar permanent features over the different locations/areas of Ratnuchak Military station for the areas as shown in the layout plan (available at the office of GE Kaluchak) including preparation of contour layout plan to show/superimposed contours @ 0.5 mtr interval. Contours should be linked to nearest Survey of India permanent bench marks.
Preparation of most economical and efficient sewage network, system including hydraulic design and calculations for quantity of sewage, storm runoff, automatic flushing tanks (AFT) (if required), manholes etc as required to complete the project including supply of requisite data and documents as required vide consultancy agreement.
Preparation of architectural and structural drawings and design of pumping station including lift wells, sump wells, automatic flushing tanks (AFT) (if required), manhole etc as required to complete the work.
Hydraulic design of MBBR including Comparison with other available technologies based STP (Sewage Treatment Plant) two Nos of capacity approximate equal to 200 KLD and 100 KLD (subject to finalization of ground data/ scheme) and preparation of general arrangement drawings as per scheme approved by Accepting Officer along with structural drawings and redistribution of treated sewage for gardening and arboriculture. The effluent quality of STP at outlet point should comply with the limits prescribed by State/ UT Pollution Control Board for arboriculture purpose and use in flushing tanks.
Electro Mechanical design of pumping station and sewage treatment plant including Supervisory Control And Data Acquisition (SCADA) automation system.
Preparation and submission of Detailed Project Report (DPR) and detailed estimates of all structures (buildings, STP, electric & mechanical parts) and sewage network including lift wells, sump wells, automatic flushing tank (AFT), (if required), manholes etc as required to complete the project based on the SSR-2020 (Rates)/ prevailing market rate/ derived rate as the case may be.Notes:- (a) The design and technology proposed for STP shall comply the norms of treated effluent parameters within the limits prescribed by State/ UT Pollution Control Board (SPCB) for arboriculture purpose and use in flushing tanks. (b) The scheme shall be designed by the consultant and submitted for scrutiny and final approval by the HQ Chief Engineer Pathankot Zone. (c) In any case, the effluent shall not be discharged into natural streams/Nallah/Canal/Natural Water bodies as per State/ UT Pollution Control Board (SPCB) norms.
Vetting of Scheme from Govt Engineering College like IIT/NIT.
Common Notes for All items:- (i) All components and entire scheme shall be designed as per CPHEEO (Central Public Health and Environmental Engineering Organisation) actual and/or relevant standards of latest edition as applicable and actual ground data shall be collected by the consultant on ground and/or from MES and/or other departments as the case may be. (ii) All misc structures like retaining walls, cross over structures, vents etc shall be planned and designed as per site requirements. (iii) All structures shall be designed for seismic Zone –IV as per IS-1893 and grade of concrete shall not be less than M-30 with exposure conditions as per IS-456. (iv) Soft copy of Hydraulic Design calculations for each sewer line and structure shall be submitted on the MS excel format along with Six sets of hard copies. (v) Structural design/output/calculations shall be submitted in PDF format along with soft copy of input files on the STAAD format/MS Excel sheet as applicable. (vi) Consultants are advised to visit site before quoting the rates and all the above mentioned aspects are deemed to be included in the quoted rates for the said Job. No claim what so ever shall be entertained at the belated stage on this account. The area falls under GE Kaluchak.
(vii) No lodging, boarding and transportation shall be provided by the department to visit the site during execution of main project as well as while performing the consultancy work and at the time of preparation of tender by the department for the main project which will be based on the DPR provided by the consultant under this contract. (viii) Consultant shall visit the site at least once in a quarter and total not less than 5 visits as decided by the GE during execution of work and provide technical assistance for implementation of design and drawings in execution and give suggestion/revision to drgs/design if required in, due to any reasons. (ix) The Consultant shall also be required to visit office of Chief Engineer Pathankot Zone and / or provide necessary clarifications when ever required during preparation and finalizing the tender/contract for the main project by the Department. The consultant quoted rates in the BOQ shall be inclusive of all such expenses to be borne by the consultant. (x) The consultant for NON compliance of any of the contractual obligations to the best satisfaction of the Accepting Officer as stipulated in these notes No (vii) and (viii) above shall be penalized as per relevant clause/paras of the contract.
PEE Consultants
INDUS WATERWAYS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .