Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-AOC | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹39.4 L+₹3.2 L (8.73%)Rejected-Finance PLOT NO 81 SHANTAJI COLONY JANKI NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L2 | Rejected-Finance Second Lowest amount quoted | |
| 3 | L3₹41.0 L+₹4.8 L (13.2%)Rejected-Finance MAIN ROAD RANJHI JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L3 | Rejected-Finance Third Lowest amount quoted | |
| 4 | L4₹41.9 L+₹5.7 L (15.7%)Rejected-Finance MANEGAON CHAMPANAGAR KHAMARIA JABALPUR 482005 MP | JABALPUR | JABALPUR | MP | 482005 | L4 | Rejected-Finance Fourth Lowest amount quoted | |
| 5 | L5₹42.0 L+₹5.8 L (15.9%)Rejected-Finance | L5 | Rejected-Finance Fifth Lowest amount quoted |
Tender Value
Refer Docs
EMD Value
₹82,000
Closing Date
16 Apr 2021, 6:00 pmClosed
Shri Dhiraj Kumar, IDSE, EE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2021_MES_430979_1
8311/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
Garrison Engineer (East) Jabalpur
D a(ii)
9 documents required · 9 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹82,000
Yes
29 May 2021
16 Mar 2021
19 Apr 2021
16 Mar 2021
16 Apr 2021
1 Apr 2021
16 Mar 2021 - 31 Mar 2021
Amount
Manning, operation and routine maintenance of water supply installation (pump house) with deputing of one skilled FGM operator of proper trade with ITI qualified having minimum 04 years of experience for round the clock of three shift of 08 hours each shift for 24 hours daily including Sunday and holidays for operation of pump sets, chloronome plant/BP Dozer for proper pumping from pump house No 37 to CMM (all OHTs) including operation of all valves, maintaining all equipment of pump house in perfect condition and keep it up always in inspection condition, cleaning of all water supply installation and surrounding area all specified and directed by Engr-in-charge. The installation comprises the following :- (i) Centrifugal pump sets 50 HP - 03 Nos (ii) Centrifugal pump sets 75 HP - 02 No (iii) Chlorine dosing plant - 01 No (iv) Submersible pump sets 12.5 HP - 05 Nos (v) DG sets 75 KVA- 01No, DG sets 125 KVA- 01No (vi) control panel boards of centrifugal pump sets and Submersible pump sets and connected starters-05 Nos
Manning, operation and routine maintenance of water supply installation (pump house) with deputing of one skilled FGM operator of proper trade with ITI qualified having minimum 04 years of experience for round the clock of three shift of 08 hours each shift for 24 hours daily including Sunday and holidays for operation of pump sets, chloronome plant/BP Dozer for proper pumping including operation of all valves, maintaining all equipment of pump house in perfect condition and keep it up always in inspection condition, cleaning of all water supply installation and surrounding area all specified and directed by Engr-in-charge. The installation of Rawalson line pump house (all OHTs) comprises the following :- (i) Centrifugal pump sets 50 HP - 02 No (ii) Centrifugal pump sets 40 HP - 04 Nos (iii) Chlorine dosing plant - 01 No (iv) Submersible pump sets 12.5 HP - 04 Nos (v) DG sets 75 KVA- 01No (vi) control panel boards of centrifugal pump sets and Submersible pump sets and connected starters (vii) Centrifugal pump sets 10 HP - 01 No and The installation of PAO(OR) pump house (In front of Rawalson line pump house handed over by GE (P) Jabalpur) (all OHTs) comprises the following :- (i) Centrifugal pump sets 50 HP - 02 No (ii) Chlorine dosing plant - 01 No (iii) Submersible pump sets 12.5 HP - 02 Nos (iv) DG sets 75 KVA- 01No (v) control panel boards of centrifugal pump sets and Submersible pump sets and connected starters.
Manning, operation and routine maintenance of water supply installation (pump house) with deputing of one skilled FGM operator of proper trade with ITI qualified having minimum 04 years of experience for three shift of 8hrs for 24 hrs daily including Sunday and holidays for operation of pump sets, chloronome plant/BP Dozer for proper pumping in Venus pump house & Signal Record (02 Nos) pump house (all OHTs) including operation of all valves, maintaining all equipment of pump house in perfect condition and keep it up always in inspection condition, cleaning of all water supply installation and surrounding area all specified and directed by Engr-in-charge. The installation comprises the following :- (i) Submersible pumping sets including connected starter - 02 Nos
Manning, operation and routine maintenance of water supply installation (swimming pool) with deputing of one skilled FGM operator of proper trade with ITI qualified having minimum 04 years of experience for two shift of 8hrs for 16 hrs daily excluding Sunday and holidays for operation of pump sets, chloronome plant/BP Dozer for proper pumping in swimming pool including operation of all valves, maintaining all equipment of pump house in perfect condition and keep it up always in inspection condition, cleaning of all water supply installation and surrounding area all specified and directed by Engr-in-charge. The installation comprises the following :- (i) Pumping sets including connected starter - 02 Nos
Notes for item Nos – 01 to 04 above are as follows:- (i) To maintain log sheet and log books for all plants and monthly duty roaster for duty staff.
(ii) POL chlorine gas or bleaching powder shall be arranged by the Engr-in-Charge as per requirement and issued to contractor on schedule B free of cost for bonafide Government use only & a pucca bound register shall be maintained showing day to day input/output only signed by JE/Engineer-in-charge/Contractor.
(iii) The unit per shift means 8 hours. The contractor shall deployed one FGM per shift of 08 hours at installation viz 3 different FGM per day.
(iv) Pumping supply hrs shall be observed as mentioned in particular specification here in after or as directed.
(v) One pumping set shall work at a time.
(vi) Timing shall be decided by GE as per requirements.
(vii) It is the responsibility of the contractor that chlorine plant/BP dozer are to be operated at the time of supply of water.
(viii) The quoted rate is deemed to include for all surrounding premises cleaning such as in side the pump, outside, toilet including cutting of grass shrubs etc and always keep ready position whenever any visiting officer visits the site the pump houses should be cleaned and neat in all respect. In case any bad/adverse remark given by any visiting officer at any time the necessary recovery @ double the rate quoted per remark per day will be charged from the contractor as certified by Engineer-in-Charge and no claim whatsoever is admissible on the account, GE’s decision is final and binding on this account.
(ix) Testing water for residual chlorine and PH value and maintain directed level as directed and proper register to be maintained.
(x) Gland packing, greasing and oiling of centrifugal pump sets shall be done monthly and proper register shall be maintained duly signed by the contractor, Engr-in-Charge & JE.
(xi) Trades men should be wear always Operators uniform and take preventive /safety measures and will use protective clothing as per code of IE rules. Department will not responsible for any type of incident.
(xii) Contractor shall be made security pass for all operators and maintain proper register duly signed by all concerned.
(xiii) T&P like spanners, screw drivers, pipe wrench, torch light, other items required for repair etc. will be provided by the contractor.
(xiv) It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duly signed kept on record and payment of trade men for the Nos of days present will only be made, Engineer-in-Charge will be responsible for payment of trade men in his presence. Contractor shall provide proper dress to tradesmen as approved by Eng-in-Charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per shift shall be made from his dues.
(xv) In case the contractor does not operate the pumping set/AC Plant for a shift or part thereof due to any reason whatsoever double of the quoted rate to each shift will be recovered.
(xvi) Leave of deployed person in inescapable cases shall be allowed on prior intimation but Contractor on demand of Engineer-in-Charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.
(xvii) In no case wages of deployed persons shall be less than the Minimum wages fixed by Govt Competent Authority. It is mandatory requirement for Contractor that payment of deployed person shall be made through Cheque/RTGS/Acceptable Electronic Mode only. Proof of payment shall be submitted by Contractor to Engineer in Charge monthaly basis or during claiming on account of Advance (RAR)/FB.
(xviii) The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952. shall be strictly adhered to by the Contractor. Social Security to workers i.e. EPF, ESIC, Personal Insurance(if applicable) on part of Employer shall be paid by Contractor and accordingly, Contractor/Bidder shall include all these factors in his quoted rate.
(xix) Statuatory levies/GST if applicable on part of contracts shall be paid by Contractor and accordingly, Contractor/Bidder shall include all these factors in his quoted rate.
(xx) Deployed person shall report daily to JE/Engineer in charge or nominated officers by Accepting Officer for their attendence & obtain instructions. An attendence register shall be maintained by Contractor on site shall be certified by MES rep every day.
(xxi) T&P - Working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by Contractor at his own cost.
(xxii) Retrieved materials obtained from replacement by new items shall be deposited in MES store.
(xxiii) An uniform of blue shirt/jersy duly embossed "MES OUTSOURCING SERVICES" at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.
(xxiv) Water & electric supply shall be provided by MES free of cost for outsourcing services only.
(xxv) Documentation - Attendance register & wages register,Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost.
(xxvi) The contractor shall arrange introductory meeting of tradesmen/personnels proposed to be employed with GE prior to finalise their employment to as certain their biodata, skill in the respective trade and final aprroval shall rest with GE. Similarly removal of service of any employed personel shall also be with the consent of GE.
(xxvii) All tradesman employed shall be insured by the contractor at his cost for the whole contract period from the date of commencemnt for any accident during the service hours.
(xviii) If quoted rates are less than minimum fair wages inclusive of GST, EPF, ESIC as applicable the bid shall be treated as non-bonafide and will be rejected. No objection/claim in this regard will be accepted
Dismantling/taking out unserviceable sluice valve of size 150 mm to 200 mm bore dia by opening/cutting rusted nuts, bolts etc all as specified and directed.
S&F the following CI sluice valves both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.6 ISI marked complete all as specified and directed :- Make : Kirloskar/L&T/Upadhiya
150 mm bore
100 mm bore
Taking up or down the following old unserviceable GI Tubing and connections :- Note :- Excavation/earthwork shall be measured & paid separately.
20 mm bore
25 mm bore
40 mm bore
S&F the followiing GI tubing medium grade with all fittings and fixed complete laid in trenches of size :-
20 mm bore
25 mm bore
40 mm bore
Taking down/removing the following Unserviceable Gate valve/stop valve from water supply lines, closing the opening with plug or preparing for new as required necessary fittings complete all as specified.
20 mm bore
25 mm bore
40 mm bore
S&F the followiing Gun metal Globe or Gate valve with iron wheel head, screwed both ends for iron pipe and fixed with required necessary GI fittings complete :- Make : Kartar/Zolto/Sant / Leader
20 mm bore
25 mm bore
40 mm bore
S&F in replacement the following stainless steel spindle suitable for following dia of sluice valve complete with stainless steel nut and threading including taking down as per sample & directed by engr-in- charge
250 mm bore sluice valve
200 mm bore sluice valve
150 mm bore sluice valve
100 mm bore sluice valve
Taking up Submersible Pump assembly including column pipe approx 50 to70 mtrs using chain pulley block manually and carrying out following phase of work all as directed for 17.5HP/15 HP Pump Set .(i) Transportation of submersible pump -motor assembly for necessary repair. (ii) Carrying out overhauling of motor assembly 3phase ,taking out burnt winding wire, with & including PVC insulated water proof copper wire with winding wire of appropriate gauge and turn, providing insulation materials and replacement of bearing and assembling with repaired/serviceable pump and testing complete all as directed by Eng-in Charge. (iii) Carrying out dismantling and overhauling of multi stage pump, incl cleaning and derusting of casing, replacement of worm out spare like bearings, impellar bushing, coupling etc & refixing of existing serviceable components after proper cleaning, machining all as required & assembling testing at workshop complete for 17.5/15 HP submersible pump of any make including carrying out painting by two coats of synthetic enamelled paint over a coat of primer,assembling the pump and motor including testing complete all as specified and directed.
Taking down unservicable existing motor starter of any size/capacity
M&L Fully Automatic Star Delta Motor starter 70 HP in sheet-steel enclosure type ML with single phase protection feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 28-42 complete all as specified. (Make : L&T / SIEMENS/schneider)
M&L Fully Automatic Star Delta Motor starter 50 HP in sheet-steel enclosure type ML with single phase protection feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 28-42 complete all as specified. (Make : L&T / SIEMENS/schneider)
M&L Fully Automatic Star Delta Motor starter 35 HP in sheet-steel enclosure type ML with single phase protection feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 22-32 complete all as specified. (Make : L&T / SIEMENS/schneider)
M&L Fully Automatic Star Delta Motor starter 25 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 13-21 complete all as specified. (Make : L&T / SIEMENS/schneider)
M&L Fully Automatic Star Delta Motor starter 15 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 11-18 complete all as specified. (Make : L&T / SIEMENS/schneider)
M&L Fully Automatic Star Delta Motor starter 12.5 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 9-14 complete all as specified. (Make : L&T/ SIEMENS/schneider)
Taking down unservicable existing cable from motor/pannel to starter any size/capacity
S & F in repair PVC Insulated unsheathed cable 19/1.54 mm dia single core multistranded bright annealed copper conductor 1100 volts, including taking down conf to IS-694 complete all as specified. Make : Plaza/ Paragon/ Polycab
S & F in repair PVC Insulated unsheathed cable 37/1.56 mm dia single core multistranded bright annealed copper conductor 1100 volts, including taking down conf to IS-694 complete all as specified. Make : Plaza/ Paragon/ Polycab
S & F in repair PVC Insulated unsheathed cable 37/2.04 mm dia single core multistranded bright annealed copper conductor 1100 volts, including taking down conf to IS-694 complete all as specified. Make : Plaza/ Paragon/ Polycab
Supply and fix in repairs submersible cable in to bore hole along with submersible pump set flat PVC insulated and sheathed water proof flexible copper conductor 1100 volts grade of size flat 3 core 10 sq mm including all necessary jointing materials/kit and connecting up motor and starter terminals and testing complete all as specified & directed. Make : POLYCAB/ FINOLEX/ RR KABEL/ HAVELLS
Dismantling/taking out unserviceable air release valve/non return/foot valve/fire hydant valve of any size by opening/cutting rusted nuts, bolts etc all as specified and directed.
Supply and fix CI double end flanged and drilled non return valve of size 200 mm PN-1.6 dia ISI MARKED MAKE : Kirloskar/Upadhyay/L&T
Supply and fix CI double end flanged and drilled non return valve of size 150 mm dia PN-1.6 ISI MARKED MAKE : Kirloskar/Upadhyay/L&T
Supply and fix CI double end flanged and drilled non return valve of size 100 mm dia PN-1.6 ISI MARKED MAKE : Kirloskar/Upadhyay/L&T
Supply and fix CI foot valve, flanged end and drilled of size 150 mm dia ISI MARKED MAKE : Kirloskar/Upadhyay/L&T
Supply and fix CI foot valve, flanged end and drilled of size 100 mm dia ISI MARKED MAKE : Kirloskar/Upadhyay/L&T
Supply and fix cast iron double ball air release valves of size 80mm as per IS 14845, PN rating H-7 ISI marked. MAKE : Kirloskar/Upadhyay/L&T
Dismantling of existing valve pit and M&L for construction of masonry valve pit (as per drawing No CEJZ/TD/819/91 dated 16/04/91) including with the following specification:- Necessary require excavation and earth work in any types of strata. Brick work in CM (1:4) with sub class 'B' bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 1200 x 1200x1200 mm,150mm thick copping on top in PCC (1:3:6), type C-1, 3mm thick MS sheet for cover, angle iron 40mmx40mmx5mm for frame all around with suitable handle with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing
Dismantling of existing valve pit and M&L for construction of masonry valve pit (as per drawing No CEJZ/TD/819/91 dated 16/04/91) including with the following specification:- Necessary require excavation and earth work in any types of strata. Brick work in CM (1:4) with sub class 'B' bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 900 x 900x1200 mm,150mm thick copping on top in PCC (1:3:6), type C-1, 3mm thick MS sheet for cover, angle iron 40mmx40mmx5mm for frame all around with suitable handle with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing
S&F in repairs MCCB 630 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : Legrand/ L&T / /Hager
S&F in repairs MCCB 400 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : Legrand/ L&T / /Hager
S&F in repairs MCCB 250 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : Legrand/ L&T / /Hager
S&F in repairs MCCB 200 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make :Legrand/ L&T / /Hager
S&F in repairs MCCB 160 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : Legrand/ L&T / /Hager
S&F in repairs MCCB 125 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make :Legrand/ L&T / /Hager
S&F in repairs MCCB 100 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : Legrand/ L&T / /Hager
S&F in repairs MCCB 63 A 16 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : Legrand/ L&T / /Hager
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr deep for fundations, manholes, laying GI/CI pipes etc n.exc 10Sqm on plan and getting out in soft/loose soil complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exce 25Cm thick complete all as specified and directed
Removing excavated soil to a distance not exce 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
Taking down of MCCB of any size
S&F in replacement Digital water leval indicator system 150 mm size digit direct display,operated on 230v Ac, suitable for upto 20 metre height over head Reservior/ underground sump of any capacity, preadjustable alarm for upper & lower level, temp range -5 to 50 degree, humidity up to 90% RH, reset push switch for silent the alarm including 4 core 1.5 sqmm copper cable. MAKE: SURYA ELECTRONICS & CONTROLS / RECTRONIC DEVICE & CONTROLS
S&F XLPE insulated armoured and PVC sheathed "heavy duty" electric cable with aluminium conductor 1100 volts grade laid in trenches, passing through pipes /ducts including testing complete of following cross sectional area of the following sizes:- Note:- Rate is inclusive of cable gland & cable lugs. The contractor shall be used old cable route indicator retrietive from item No 33 to 35 above. Fixing cost for the same shall be included in the quoted rates of these items. Make : Havells/GLOSTER/Poly Cab/Paragon
3 -1/2 core, 50 sqmm cross sectional area
3 -1/2 core, 70 sqmm cross sectional area
3 -1/2 core, 95 sqmm cross sectional area
3 -1/2 core, 120 sqmm cross sectional area
3 -1/2 core, 150 sqmm cross sectional area
3 -1/2 core, 180 sqmm cross sectional area
3 -1/2 core, 400 sqmm cross sectional area
S&F in repairs 40mm bore, GI steel tubing "light grade" for cable protection passing under road /floor or for fixing to poles complete all as specified and as directed Make :- JINDAL/ ZENITH/ TATA/ PRAKASH
S&F in repairs 50mm bore GI steel tubing "light grade" for cable protection passing under road /floor or for fixing to poles complete all as specified and directed Make - JINDAL/ ZENITH/ TATA/ PRAKASH
S&F in repairs 80mm bore GI seel tubing "light grade" for cable protection passing under road /floor or for fixing to poles complete all as specified and directed Make - JINDAL/ ZENITH/ TATA/ PRAKASH
M&L unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified. Note : Measurement shall be done after puning down of sand.
M&L Brick covering with width equal to length of bricks as mechanical protection to cable with well burnt sub class `B` old size bricks laid dry and flat complete all as specified and as directed.
Supply and lay in repairs 80 mm bore GI column pipe heavy grade ISI marked in standard length of 3 meter each duly threaded with both ends with and including long threaded heavy duty socket and fittings and lowering into well including supplying, lowering ,fixing, commissioning & testing complete all as specified and directed. Make : JINDAL/ TATA/ OSWAL/ ZENITH
Schedule of credit amount of Rs. 1,49,525.00 to be deducted during AOC
shri krishna traders
RAVINDRA ELECTRICAL
ASHOKA ASSOCIATES
GAUTAM ELECTRIC WORKS
Goodluck Enterprises
M/S INDIA ENTERPRISES
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .