Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 CrAccepted-AOC | ₹2.9 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹3.2 Cr+₹25.8 L (8.91%)Rejected-Finance NOT SPECIFIED | ₹3.2 Cr+₹25.8 L (8.91%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹3.4 Cr+₹46.5 L (16.0%)Rejected-Finance D 3 7TH BLOCK JAIN GREEN ACRES DHARGA ROAD ZAMIN PALLAVARAM CHENNAI 600043 | CHENNAI | CHENNAI | TAMIL NADU | 600043 | ₹3.4 Cr+₹46.5 L (16.0%) | L3 | Rejected-Finance Not being L1 |
| 4 | Rejected-Technical BLDG NO 22 2079 COAST GUARD ROAD NEAR COAST GUARD FAMILY ACCOMMODATION MUNDAMVELI PO PALLURUTHY VII ERNAKULAM 682 507 | ERNAKULAM | ERNAKULAM | KERALA | 682507 | - | - | Rejected-Technical See evaluation report |
| 5 | Rejected-Technical | - | - | Rejected-Technical See evaluation report |
Tender Value
Refer Docs
EMD Value
₹3.9 L
Closing Date
1 May 2021, 6:00 pmClosed
CE AF BANGALORE
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
PROVN OF WORK SERVICES FOR BUYER FURNISHED FACILITIES AT AFS SULUR
2021_MES_431549_1
801488/E8
Open Tender
Civil Works
Lump-sum
546 days
GE (AF) Sulur
As per NIT
8 documents required · 8 mandatory
₹2,000
Yes
GE (AF) Sulur
₹3.9 L
Yes
12 Jun 2021
18 Mar 2021
3 May 2021
18 Mar 2021
1 May 2021
18 Apr 2021
18 Mar 2021 - 8 Apr 2021
Amount
BOQ dated 18 Mar 2021
GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to IX are prepriced by MES under Ser No. 1 to 10. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “Building or works” as listed in Schedule ‘A’ Part–I
Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part–II
Lumpsum price worked out by the contractor for “Internal Electric Supply" as listed in Schedule ‘A’ Part–III
Lumpsum price worked out by the contractor for “Road” as listed in Schedule ‘A’ Part – IV.
Lumpsum price worked out by the contractor for “Sewage Disposal" as listed in Schedule ‘A’ Part V .
Lumpsum price worked out by the contractor for “Gate” as listed in Schedule ‘A’ Part – VI.
Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part – VII.
Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part – VIII.
Lumpsum price worked out by the contractor for “Special items (B/R)” as listed in Schedule ‘A’ Part – IX.
Sch 'A' Part - X : Fittings / Fixtures & Misc items. INTERNAL WATER SUPPLY Supply and fix Angle cock, cast copper alloy with capstan head chromium plated, screwed down, high pressure, screwed both ends for PP-R pipe and fixed suitable for 15 mm dia pipe complete all as specified and as directed.
ROAD Material and labour for applying evenly a priming / tack coat with rapid setting bitumen cationic emulsion conforming to IS - 8887 at 6 Kg / 10 Sqm over unsyfaced macadam surfaces all as specified and as directed.
INTERNAL ELECTRIC SUPPLY Supply and fix sub main wiring complete 2 runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor, with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor as earth continuity conductor, drawn through and 25mm dia PVC rigid conduit and conduit accessories laid in ducts duly fixed / concealed in wall / ceiling complete all as specified and as directed. NOTE: 2 runs of 10 sqmm cable alongwith one run of 10 sqmm cable for earth conductor and PVC conduit shall be measured as one length
Supply and fix sub main wiring complete 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor, with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor as earth continuity conductor, drawn through and 25mm dia PVC rigid conduit and conduit accessories laid in ducts duly fixed / concealed in wall / ceiling complete all as specified and as directed. NOTE: 2 runs of 6 sqmm cable alongwith one run of 6 sqmm cable for earth conductor and PVC conduit shall be measured as one length
Supply and fix sub main wiring complete 4 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor, with 2 run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor as earth continuity conductor, drawn through and 25mm dia PVC rigid conduit and conduit accessories laid in ducts duly fixed / concealed in wall / ceiling complete all as specified and as directed. NOTE: 4 runs of 6 sqmm cable alongwith 2 runs of 6 sqmm cable for earth conductor and PVC conduit shall be measured as one length
Supply and fix sub main wiring complete 4 runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor, with 2 run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor as earth continuity conductor, drawn through and 25mm dia PVC rigid conduit and conduit accessories laid in ducts duly fixed / concealed in wall / ceiling complete all as specified and as directed. NOTE: 4 runs of 10 sqmm cable alongwith 2 runs of 10 sqmm cable for earth conductor and PVC conduit shall be measured as one length
Supply and fix MCB DB TPN 4 way horizontal double door, IP 43, 415 V, 50 Hz suitable for MCB TP as incomer and MCBs TP/SP as outgoing with tinned copper bus bar, neutral link earth link complete all as specified and as directed.
Supply and fix MCB DB SPN 8 way horizontal double door, IP 43, 415 V, 50 Hz suitable for MCB SPN as incomer and MCBs SP as outgoing with tinned copper bus bar, neutral link earth link complete all as specified and as directed.
Supply and fix MCB DB SPN 4 way horizontal double door, IP 43, 415 V, 50 Hz suitable for MCB SPN as incomer and MCBs SP as outgoing with tinned copper bus bar, neutral link earth link complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3mm thick buried in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to galvanised earth lead wire 4.00mm GI earth continuity conductor including 15 mm bore pipe Light grade for protection of lead by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel connected to maint switch control board upto 7.5 mt away from earth electrode all as shown as per plate No 03 of SSR part - I including necessary earth work, PCC 1:3:6 type C1 chamber, RCC cover slab of 50 mm thick 1:2:4 with 8 mm CTD 140 mm C/C with suitable handle, watering pipe 20 mm dia medium grade pipe with funnel, charcoal, salt and testing on completion with connected items all as directed.
Taking down carefully by unscrewing from boards / sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and rugulators etc and deposit to AGE E/M store complete all as specified and as directed.
Supply, fix and connecting up Heavy duty Exhaust fan of size 450mm sweep 1400 rpm complete with cable 3 core of size 0.5 sqmm from ceiling rose to fan, provision of 3mm thick bakelite sheet cover including writing MES No 2 cm height with synthetic enamel black paint all as specified.
Supply, fix and connecting up ceiling fan of size 1200mm sweep complete including with modular type fan step regulator 120W, 2 module cable 3 core of size 0.5 sqmm from ceiling rose to fan, including writing MES No 2cm height with synthetic enamel black paint complete all as specified and as directed.
Supply, fix and connecting up wall mounted fan of size 400mm sweep 1320 RPM metal blades with pull cord mechanism for speed control complete with necessary fixing arrangements including writing MES No 2cm high with synthetic enamel black paint complete all as directed.
Supply, fix and testing of 4 feet LED surface and wall mounted sleek and seamless profiled extruded / polycarbonate batten LED luminaries, 19/20 Watts, with latest LED technology and efficient optics ensuring perfectly uniform illumination and unparalleled light distribution, high optically efficient diffuser, 50000 burning hours, with 70% of its initial lumen maintained, fixed complete including all accessories and provision of PVC sheathed 3 core 1.5 sqmm copper conductor for connection complete all as specified and as directed. Make: Wipro, Cat Part No. LL20-281-XXX-65AL1 / Havells, Cat Part No. ENDURA LINEAR NEO BS 20W LED 840SPC WH or equivalent in BAJAJ / PHILIPS
Supply, fix and testing 15W, high efficient LED street light, aluminium pressure Die cast housing parts for long life, pure polyster powder coated Dark grey housing, toughened glass with silicon gaskets for protection, driver cover designed to suit top maintenance, suitable for fixing on walls / poles, including suitable GI pipe bracket not less than 1.5m long, CCCV driver with Voltage range 150-270V AC surge protection from over voltages, 3.0KV in CM, 50000 burning hours, Make: BAJAJ CAT Part No. BRLEP 15W LED / Havells Cat Part No. ENDURA PEARLSL 15 WLED757 SASYTOPC / Crompton Cat No. LSTS-15-CDL
Supply and fix LED 1x4 surface ceiling light with height performance 40 watts light fitting. Model: SPAN of Crompton cat reference No. LCTLSN-40-CDL (1x4) or equivalent approved make. Note: The rate quoted deemed to include the cost of fixing arrangement as specified by the manufacturer on ceiling.
Supply and fix surface mounted LED square down light fitting surface mounted 6-8 watts with CRCA powder coated housing, with a life time of 50000 burning hours as per L70 criteria, power factor> 0.9, Driver should meet IEC compliant for safety with multi stage high isolate CC-CV operated driver with voltage variation range - 150 to 270 volts AC, surge protection of 3 KV and including connecting up with PVC sheathed 3 core 1.5 sqmm copper conductor flexible wire fixed complete all as specified and as directed. Make : BAJAJ Cat No. BGSLO sleek surface 8W WH SQ surya Cat No SLE DLS 6WXX stellar SQ 6 W or equivalent in WIPRO / HAVELLS / PHILIPS Note: The contractor shall submit warranty certificate from manufacturer for both light and driver
Material and labour for wiring for circuit with heat resistant retardant HRFR PVC insulated industrial copper conductor cable of size 10 sqmm complete all as directed.
Material and labour for wiring for circuit with heat resistant retardant HRFR PVC insulated industrial copper conductor cable of size 16 sqmm complete all as directed.
Supply and fix MCB TPN 32 amps 415 volts 10 KA 50 Hz complete all as directed.
Supply and fix MCB SP 6 to 32 amps 415 volts 10 KA 50 Hz C curve complete all as directed.
Supply and fix MCB SPN 16 amps 415 volts 10 KA 50 Hz with enclosure complete all as directed.
Supply and fix Energy efficient recessed mounted LED luminaire for 2x2 grid ceiling suitable for clean room of capacity not less than 30 watts, 240 volt complete with constant current electronic driver and all accessories including connecting up with ceiling rose using twin core twisted flexible copper conductor cable of suitable size all as specified and as directed. Make: Wipro Cat No. LC 20-551 or equivalent in Havells / Bajaj / Philips
Supply and fix MCB single pole 25 Amps complete all as specified and as directed.
Supply and fix MCB single pole and Neutral 32 Amps complete all as specified.
EXTERNAL WATER SUPPLY Material and labour for cutting the existing 80 mm GI pipe and inserting, supply and fix GI TEE (50X50X40 mm) and necessary threading, union etc complete all as directed.
EXTERNAL ELECTRIC SUPPLY Supply and installation of copper wound transformer step down, outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:2026 of capacity upto 100 KVA (K factor 13) complete all as specified and as directed.
Supply and installation of copper wound transformer step down, outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:2026 of capacity upto 160 KVA (K factor 13) complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 200 KVA complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, outdoor type & designed for input variation between 340V to 460V with output voltage stabilized at 415V with accuracy +/- 2.5 % and speed of correction 8 Volts per second and of capacity 100KVA complete all as specified and as directed.
Material and labour for earthing complete with galvanised steel earth plate electode 600 x 600 x 6 mm thick burried directly in ground earth pit not less than 2.25 mtr deep below ground level connected to & including galvanised iron strip 32 x 6 mm as earthing lead by means of nuts, bolts, check nuts and washers of galvanised iron, passing throgh protection pipe of 40 mm dia light grade GI pipe all as shown in electrical plate Nos 3 of SSR Part - I and connected to machinery / equipment complete including testing filling of adquate quantity of charcoal dust and common salt including excavation and refilling earth and removal of surplus soil upto 50 mtrs and PCC 1:3:6 type CI chamber, precast RCC cover 50 mm thick reinforced with 8 mm dia MS bar 3 Nos both way with handle made out of MS rod 12 mm dia and watering pipe 20 mm dia LG with funnel, wire mesh etc and connecting and testing complete all as specified and directed.
Supply and installation of 11 KV, 3 phase, 630 Amp, 25 KA/1 sec load break switch with 200 Amp DO set and earth switch, Fuse trip mechanism, HT HRC Fuse -50 A, 230VAC Trip coil and Aux contact 2 No+2NC, Operation - Manual ON/OFF Both LBS and Earth switch with following specifications: ENCLOSURE- CRCA sheet steel enclosure suitable for outdoor protection IP-55 with provision of bottom cable entry (incoming &outgoing) system excluding cable termination kits, lugs and glands. BUS CONNECTION- ALUMINIUM BUS BAR 630A: Main aluminium bus bar of size 1RX50X12mm with heat shrinkable HT sleeves insulation and earth bus bar size 1RX40X6mm with heat shrinkable sleeves insulation. INDICATION LAMP: suitable LED indication lamp 230 V AC for LBS ON/OFF, LBS E/S ON/OFF. CONTROL SWITCHES: Toggle on/off switch for space heater 10A 230V AC, Door limit switch for CFL 1 No + 1NC 230V AC, Emergency Trip push button, MCB DP 10A - 1 No with space heater, thermostat, Cubicle illumination lamp with holder, 11KV Surge arrester (9KV, 10KA) all as specified and as directed.
Supply, installation, testing and commissioning of maintenance free grounding solution set comprising of High tensile low carbon steel rod of 3 mtr length and 17.2mm dia with 250 micron (average) molecularly bounded copper on the outer surface to confirm with requirements of UL 467 including suitable copper earth termination clamp alongwith back fill compound of 3X25 kgs strictly of carbon based conductive concrete type, have a fixed carbon content of more than 99% and resistivity of less than 0.12 ohm per mtr, standard back fill compound should be electrically conductive (Like in metals) and should not depend on moisture for conduction, size of bore 150 to 200 mm dia, 12 feet depth, including provision of earth pit cover made of heavy duty polyplastic and earth inspection cover made of high grade polypropylene of size top dia 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia, with Cap complete all as specified and directed. Make : JEF Eco safe earthing/ISG Global or equivalent. Note : Copper Strip 25 x 3 mm for loop/inter connection between earth pits will be measured separately.
Supply and fix LT feeder pillar box totally enclosed floor mounted Indoor type weather and vermin proof made out of MS sheet 3.15 mm thick duly painted with 2 coats of enamel paint over a coat of red oxide primer consisting of the following items :- (a) TPN bus bar 315 Amps - 01 set (b) MCCB Four Pole 160 Amps, 50 KA - 01 No (c) MCCB 4 pole 100 Amps-1 No (d) MCCB 4 pole 63 Amps 35 KA -8 Nos (e) Digital Multifunction Meter to measure Volt, Amps, PF etc. for three phase, with CT-1 No (f) LED indication lamps with backup MCB for 3 phase supply –1 set. (P-15 /Main LT panel)
Supply and fix Capacitor metalized polypropylene heavy duty (MPP-H) for 3 phase 440V, 50 Hz, system for permissible non linear load 15% of 50 (25x2) KVAR Capacity complete all as specified and as directed.
Supply and fix copper control cable 6 sqmm 3 core for AC complete all as specified and as directed.
Supply and laying of 4 core 16 sqmm copper cable for AC complete all as specified and as directed.
Supply and fix LT feeder pillar box totally enclosed floor mounted Indoor type weather and vermin proof made out of MS sheet 3.15 mm thick duly painted with 2 coats of enamel paint over a coat of red oxide primer consisting of the following items :- (a) TPN bus bar 400 Amps - 01 set (b) MCCB 4 Pole 320 Amps, 35 KA - 01 No (c) MCCB 4 pole 160 Amps, 35 KA - 01 Nos (d) MCCB 4 pole 125 Amps, 25 KA - 01 Nos (e) MCCB 4 pole 100 Amps, 25 KA - 02 Nos (f) Digital Multifunction Meter to measure Volt, Amps, PF etc. for three phase, with CT-1 No (g) LED indication lamps with backup MCB for 3 phase supply –1 set. (main LT panel Board/P-26)
Supply, fixing, testing and commissioning LT panel board indoor type mounted on floor made out of MS sheet 3.15 mm thick duly painted with 2 coats of enamel paint over a coat of red oxide primer consisting of the following items :- (a) TPN bus bar 400 Amps - 01 set (b) MCCB 4 pole 250 Amps, 35 KA - 02 Nos (c) MCCB 4 pole 63 Amps 35 KA -2 Nos (d) Digital Multifunction Meter to measure Volt, Amps, PF etc. for three phase, with CT-1 No (e) LED indication lamps with backup MCB for 3 phase supply –1 set. (P/26 Bldg with 120 KVA Test bench)
Supply, fixing, testing and commissioning LT panel board indoor type mounted on floor made out of MS sheet 3.15 mm thick duly painted with 2 coats of enamel paint over a coat of red oxide primer consisting of the following items :- (a) TPN bus bar 200 Amps - 01 set (b) MCCB 4 pole 100 Amps, 35 KA - 02 No (c) MCCB 4 pole 63 Amps 35 KA -1 Nos (d) Digital Multifunction Meter to measure Volt, Amps, PF etc. for three phase, with CT-1 No (e) LED indication lamps with backup MCB for 3 phase supply –1 set.
Supply and fix capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase 440 v 50 HZ system for permissible non-linear load 15% of 80 (20x4) KVAR Capacity complete all as specified and as directed.
Supply and spreading and compacting riddled sand in trenches for cable cushioning 8 cm at bottom and15 cm at top of cable complete all as specified and as directed.
Supply and lay burnt bricks sub class 'B' of old size laid dry in trenches for under ground cable protection all as specified.
Supply and fix cable gland double compressed for various size from 95 sqmm to 300 sqmm complete all as specified and as directed.
SPECIAL POWER SUPPLY Supply, install and testing of high precision variable DC (Rectifier) regulated Power supply 0-32 V, 0-60 A, 1.92 KW complete all as directed. Make- Aplab, Model No. L3260 or equivalent approved in Powerone, Volina
Supply, install and testing of high precision variable DC (Rectifier) regulated Power supply 0-32 V, 0-45 A, 1.44 KW complete all as directed. Make- Aplab, Model No. L3260 S or equivalent approved in Powerone, Volina
Supply, install and testing of high precision variable DC (Rectifier) regulated Power supply 0-32 V, 0-120 A, 3.84 KW complete all as directed. Make- Aplab, Model No. L3299 S or equivalent approved in Powerone, Volina
Supply, install and testing of Frequency converter 5 KVA suitable for input supply single phase, 3 wire, 230 V, AC, 50 Hz, and out put supply 115VAC, 400Hz, 1P, 3 wire, LCD display complete all as directed. Make- Aplab or equivalent approved make.
Supply and fix Static Frequency converter 25 KVA suitable for input supply three phase, 340-440 V, AC,50 Hz and out put supply 115 V, AC-400 Hz, single phase, 3 wire, LCD display complete all as directed. Make-APLAB or equivalent approved make.
COMPRESSED AIR SUPPLY Supply and fix Portable compressor of 30 Litre tank capacity (0.75 HP) and hoses for spray painting complete all as specified and as directed.
Supply and fix 7.5 KW/10 HP Reciprocating Air compressor on 420 litres horizontal Air Receiver provided with Air cooled After cooler and D.O.L Starter - Two stage. (a) Capacity (Free Air Delivery) : 37.5 CFM, (b) Power (KW/HP) : 7.5/10, (c) Normal working pressure : 12Kg/Sqcm, (d) No of stages : Two stages/two cylinder, (e) Cooling system : Air cooled (f) Motor - 10 HP 3 phase SQC induction motor, TEFC type, suitable for operation on 400+10% 3 ph,50 Hz, AC supply, F class insulation with IP55 deg of protection (g) Starter - Star/Delta (h) Air receiver capacity : 250L
Supply and fix stainless pipe 25 mm bore, ISI marked, Heavy duty, class C, fixed to wall with necessary pipe supports, clamps, brackets and suitable for compressed air supply line of 7 to 8 bar complete all as directed.
Supply and fix stainless pipe 15 mm bore, ISI marked, Heavy duty, class C,' including all tube fitting such as bend, elbow, tees, reducers, sockets etc and fixed to wall/floor/ceiling with necessary pipe supports, clamps, brackets and suitable for compressed air supply line of 7 to 8 bar complete all as directed.
Supply and fix auto drain valve 15mm, ISI marked, high pressure, screwed for steel pipe heavy duty, Class C and suitable for compressor air supply line 7 to 8 bar complete all as specified and directed.
Supply and fix ball valve 15mm, ISI marked, high pressure, screwed for steel pipe heavy duty, Class C and suitable for compressor air supply line 7 to 8 bar complete all as specified and directed.
Supply and fix quick release coupling 15mm, ISI marked, high pressure, screwed for steel pipe heavy duty, Class C and suitable for compressor air supply line 7 to 8 bar complete all as specified and directed.
Supply and fix filter, regulator and lubricant with gauge on regulator and suitable for compressed air supply line of 7 to 8 bar complete all as specified and as directed.
Supply and install air blow gun 15mm 10 mtr long fibre brailded air hose heavy duty flexible suitable for 10 Kg sqcm pressure with pressure guage complete all as specified and as directed.
AIR CONDITIONING Supply, installation, testing and commissioning of inverter split unit indoor / outdoor single phase 230 V 50 Hz complete with BLDC compressor Anti allergy coating, Anti virus coating, dehumidification, Refrigerant R410 A of capacity 1.5 TR (copper tube) 5 star rated all as specified and as directed. Make: Blue star Cat No. 5CNHW18PAFU or equivalent of LG / SAMSUNG
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 285 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA. Model No VND500 of V-Guard or equivalent approved make.
Supply and fix distribution boards, single pole MCB 10 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified (Make/Model : Lexic MCB of MDS Legrand Cat No : 408590 to 408595 or equivalent in Schneider / Siemens / L&T
Sub main wiring with 2 runs of 4 Sqmm PVC insulated unsheathed 1100 volts grade multi stranded copper conductor cable in and including non metallic rigid PVC conduit / casing capping with all accessories fixed to wall / roof / ceiling / floors along with 1.5 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100 V grade as earth continuity conductor and connected to common earth dolly. Note : 2 runs of 4 Sqmm cable along with one run of 1.5 sqmm cable for earth conductor and PVC conduit / casing capping shall be measured as one length.
SPECIAL ITEMS (AIR CONDITIONING) Supply, Installation, testing and commissioning of indoor type double skinned (0.6mm outer/0.6mm inner/26 mm Poly eurothene puf) Horizontal Floor Mounted/Top Discharge DX Type Air Handling Unit. The Air handling unit is fitted with a double inlet, double width (DIDW) Direct drive fan with forward curved blades (belt driven is not acceptable). Fan operation is monitored using an airflow sensor. In the event of a fan failure all other unit functions are inter locked to prevent their operation. Electric motor for fan to be TEFC type withIP-55 and class F insulation. The control system will be deemed to be include with modular microprocessor based electronic control only. Cost for following items indoor/outdoor stand/power and control cable between indoor and outdoor/rubber pad/transportation till site etc. Actual capacity of AHU to be of not less than 17 TR / 7500 CFM minimum flow/Humidification 60% + or - 5% / 100 mm static pressure @ outdoor temp 41 deg C. Noise level not to exceed 85 db at 2 Mtrs, complete all as per note given here in after.
(a) Modular AHU panels with GI sheet of 0.6 mm outer /0.6 mm inner/ 26 mm poly eurothene PUF insulation sandwiched in between the outer panel will have pre-coating for corrosion resistance as also to provide a very good finish. (b) Drain section with 0.8 mm SS drain pan and pipe shall be extended as directed. (c) Filter section with 5 MICRON HDPE woven mesh filter in aluminium frames (d) Cooling coil section shall be with minimum 4 rows DX type (e) AHU shall be suitable for supply air plenum and return air shall be provided with suitable strip heater, suitable control shall be provided for humidity 60% +/- 5% such that automatically the heaters will be operated to maintain required humidity. (f) AHU control panel shall be equipped with necessary shut down relay arrangements in the event of fire as per the fire safety norms.
Supply and installation of Ducting made out of 24 guage GI sheet with proper gaskets, supports, angle frames, rods etc and fabricated as per ISI standards and as directed. Insulation : Insulation material with Nitrile foam/cross linked Polythylene material outer and adhesive will be used (SR 505)
Supply and fix HEPA Filters with Plenum Box, Media Ultra clean glass fibre paper-imported, and aluminium casing, High efficiency particular air designed to remove particles down to 0.3 Microns from air streams with an efficiency of 99.997%. The filter matrix comprises specially treated glass fiber media of size 550x550x75 mm complete all as specified and as directed.
Supply and fix grills/ diffusers for supply air duct made out of CRCA sheet 1.2 mm thick, with perforation duly power coated etc adjustable type (with flow regulating arrangements all as directed.
Supply and fix Return air riser with, grills/diffusers and pre filters, Flange type, synthetic, non-oven polyster fiber, Washable with casing of aluminium of 20 micron with 90% efficiency for return air duct made out of aluminium duly power coated with all as directed.
Supply and Fix Galvanised steel Volume control damper, Opposed / parallel Blade Dampers are used to carry out a rough air system balance with closer control being carried out at the individual grilles or diffusers for supply air complete all as directed.
Supply and Installation of Magnehelic Pressure guage 0-10 mm for monitoring differential room pressures with Tubing & Pressure Nozzle with SS box complete all as directed.
SPECIAL ITEMS (B/R) Supply and fix Ceiling paneling system with tongue & groove type panel for wall paneling system and profile type for ceiling paneling system, return air raiser ducts as per the requirement and the panel will be double skin pre coated 8mm thick GI on both sides with fire rated EPS or injected PUF 38/40 Kg per cum in fill including accessories like flashing bottom track ceiling suspension induction screws tie rod reinforcing clamps and brackets etc for panel thickness 50 mm complete all as specified and as directed.
Supply and fix Wall paneling system with tongue & groove type panels for wall paneling system and profile type for ceiling paneling system return air raiser ducts as per the requirement and the panel will be double skin pre coated 8mm thick GI on both sides with fire rated EPS or injected PUF 38/40 Kg per cum in fill including accessories like flashing bottom track ceiling suspension induction screws, tie rod reinforcing clamps and brackets etc for panel thickness 50 mm complete all as specified and as directed.
Supply and fix Clean room Flushed Doors of PCGI, PUF infill 60-80 micron painted with flush double glazing glass hardware like, door closure, Stainless steel D handles, Stainless Steel ball bearing butt hinges and with provision for concealed automatic door bottom seal etc of size
Single Leaf Door : 915 x 2100 mm
Single Leaf Door : 1200 x 2100 mm
R 50 Extruded PVC /AL Covings for the entire corners
3 D Corner coves
View glass for panel of size 900mm x 900mm double glass view
Material and labour for 3mm thick Epoxy flooring with required screed and necessary base preparation with desired colour complete all as specified and as directed by Engineer in charge.
Material and labour for Epoxy Coving for floor to wall joints to avoid sharp edges for easy cleaning and maintenance complete all as specified and as directed.
Supply and fix aluminium fixed partition, partition frame (section No 20047) of size 63.50x38.1x1.53 mm weighing 0.942 kg/RM with powder coating of min thickness 50 micron, 5 mm thick plain glass at top & 12 mm thick pre-laminated particle board at bottom including glazing clips, rubber neoprnepaching, hinges, handles, snap beading screws, mortice lock etc complete all as specified and as directed.
Supply and fix Aluminium door FRAME of size (section No 20047) 63.5x38.1x1.53 weighing 0.942 Kg/m, SHUTTER frame vertical member (section No 19569) of size 47.62x44.45x2.02 weighing 1.059 kg/m, shutter top horizontal frame (section No 19528) of size 47.62x10.16x1.74 weighing 0.881 kg/m, shutter bottom horizontal frame (section No 19529) of 47.62x95.25x1.70 weighing 1.301 kg/m, with powder coating of min thickness 50 micron, 5 mm thick colour tinted glass at top,12 mm thick pre-laminatead particle board at bottom, including decorative aluminium handles, hinges, glazing clips, rubber neoprene packing, snap beading screws, Aluminium body door closer hydraulically regulated designation No 3, Mortice lock etc complete all as specified and as directed.
United Sales Corporation
lakshmibuilders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .