Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Lowest quoted tenderer | |
| 2 | L2₹19.3 L+₹4.2 L (28.0%)Rejected-Finance | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L3₹20.9 L+₹5.8 L (38.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
Refer Docs
EMD Value
₹55,440
Closing Date
23 Jul 2022, 6:00 pmClosed
CWE Allahabad
HQ CWE New Cantt Allahabad
REPAIR AND MAINT OF CENTRAL AC PLANT, PACKAGE AND WALK IN COOLER ETC ARMY AREA AT NEW CANTT UNDER GE (WEST) ALLAHABAD.
2022_MES_530572_1
81679/W/E8
Open Tender
Civil Works
Item Rate
180 days
Allahabad
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (West) Allahabad
₹55,440
Yes
16 Sept 2022
13 Jun 2022
25 Jul 2022
14 Jun 2022
23 Jul 2022
27 Jun 2022
Amount
M&L for checking the leakage in both low and high side of the system by feeding dry nitrogen upto 300 PSI to maintain adequate pressure in the system, plugging the leaks including S&F in replacement of Teflon sealing of all refrigerant line valves like liquid lines valves/ suction/ discharge valves of compressors, gland packages of all angle valves flaring of all connections framing welding etc complete for AC plant of capacity 3x37.5TR-Plant for OT millitary Hospital, complete all as specified and directed by Engineer-in-Charge.
M&L for opening the upper sheet and side sheet of AHU for access to cooling coil including for washing/cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing of air filters and re-fixing and changing of V Belt both set with necessary fitting and T&P for mounting for AC plant of capacity 3x37.5TR-Plant for OT Millitary Hospital, complete all as specified and directed by Engineer-in-Charge.
M&L for PCB Package AC plant of capacity 9 TR including in replacement of nut, bolt and other packing material etc; checking the proper electric connection, testing and commissioning for smooth operation at optimum efficiency for 803 FD Workshop, complete all as specified and directed by Engineer-in-Charge.
Taking out the existing unserviceable the item of packege AC 9 TR capacity, item including cooling coil, air filters, plasma filters etc (indoor uint), condenser, condenser, fan motor etc electrical/electonic circuits realays,wiring kit,thermostats, swiches, knobs,remort control unit, including PCB , fan blower and refixing the same in ex position complete after replacement wiht supply only meterial from item no 7.00 to 17.00 all as specified and directed
Supply and fixing cooling coil of 4ft X 3ft , four row deep sutable for 9TR complete all as specified and directed.
Supply and fixing of indoor air bolwer motor 9 TR capacity complete all as specified and directed.
Supply and fixing cooper wounded condensor fan motor packege type AC of 9 TR Capacity out door unit complete all as specified and directed.
Disconnecting the mains and taking out the UNSV condensor coil of packege type AC capacity of 9 TR any make form any location and supply fixing and testing new condenser coil as per exiting size and patterns for complete all as specified and directed.
S&F condensor fan blade of alluminium for package type AC of capacity 9 TR as per Existing size as specified and directed
S&F in repair of Expansion Valve for package type AC of capacity of 9 TR complete all as specified and directed by Engineer-in-Charge. Make :- Danfos/Emerson/Temsuch
S&F for Thermostate of package type AC capacity of 9 TR all as per existing, complete all as specified and directed by Engineer-in-Charge
S&F in replacement of suction valve set of size 9.52 mm (3/8") for package type AC capacity 9 TR all as specified and directed by Engineer-in-Charge. (Note:- Supply and filling of refigerant gas shall be measured and paid under relevent items)
S&F in replacement of discharge valve set of size 9.52 mm (3/8") for package type AC capacity of 9 TR all as specified and directed by Engineer-in-Charge. Make :- LG/Voltas /blue star/Hittachi
S&F for Cooling coil package type AC capacity 9 TR including cheking leaking welding and other packing material etc, testing and commissioning for smooth operation complete all as specified and directed by Engineer-in-Charge.
Removing burnt/defective sealed compressor unit of any make from any type of Package type AC capacity 9 TR by cutting of suction and discharge lines unscrewing the foundation nuts, bolts etc, supply and fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with gas welding/brazing work and tightening foundation nuts & bolts etc complete all as specified and directed
M&L PCB Package AC plant of capacity 6 TR including in replacement of nut, bolt and other packing material etc; checking the proper electric connection, testing and commissioning for smooth operation at optimum efficiency, for 803 FD Workshop complete all as specified and directed by Engineer-in-Charge. Make :- LG/Voltas /blue star/Hittachi.
Taking out the existing unserviceable the item of packege AC 6 TR capacity, item including cooling coil ,air filters,plasma filters etc (indoor uint), condencer, condencer ,fan motor etc electrical/electonic circuits realays,wiring kit,thermostats, swiches, knobs,remort control unit, including PCB , fan blower and refixing the same in ex position complete after replacement wiht supply only meterial from item no 20 to 30 complete all as specified and directed.
Supply only cooling coil of 4ft X 3ft , four row deep sutable for 6TR complete all as specified and directed.
Supply only of indoor air bower motor 6 TR capacity complete all as specified and directed.
Supply only cooper wounded condensor fan motor packege type AC of 6TR Capacity out door unit complete all as specified and directed.
Disconnecting the mains and taking out the UNSV condensor coil of packege type AC capacity of 6TR any make form any location and supply fixing and testing new condercer coil as per exiting size and patterns for complete all as specified and directed.
Supply only condensor fan blade of alluminium for package type AC of capacity 6TR as per Existing size as specified and directed
Supply only in replacement of Expansion Valve for package type AC of capacity of 6TR complete all as specified and directed by Engineer-in-Charge. Make :- Danfos/Emerson/Temsuch
Supply only for Thermostate of package type AC capacity of 6TR all as per existing, complete all as specified and directed by Engineer-in-Charge
Supply only in replacement of suction valve set of size 9.52 mm (3/8") for package type AC capacity 6 TR all as specified and directed by Engineer-in-Charge. (Note:- Supply and filling of refigerant gas shall be measured and paid under relevent items)
Supply only in replacement of discharge valve set of size 9.52 mm (3/8") for package type AC capacity of 6 TR all as specified and directed by Engr-in-Charge. Make :- LG/Voltas /blue star/Hittachi
Supply only for Cooling coil package type AC capacity 6 TR including cheking leaking welding and other packing material etc, testing and commissioning for smooth operation complete all as specified and directed by Engineer-in-Charge.
Removing burnt/defective sealed compressor unit of any make from any type of Package type AC capacity 6 TR by cutting of suction and discharge lines unscrewing the foundation nuts, bolts etc, supply and fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with gas welding/brazing work and tightening foundation nuts & bolts etc complete all as specified and directed
M&L for dismantling of electric driven horizontal induction motor of capacity 35/40 HP of any type and make, by engaging sufficient man power and suitable T&P to ensure safety of motor including disconnecting of electric connections, dismantling of motor, taking out the burnt windings, cleaning and washing of slots and rewinding the same with copper winding wire of existing gauge and quantity (as per original manufacturer design) including replacement of all damaged parts i. e. bearings, bush, thrust plate, thrust bearing, connector plate, insulating materials such as insulating sheets insulating paper (Class "F"), sealing compounds etc and reassembling the motor after varnishing, heating/drying, greasing of moving parts etc and reinstallation of the motor in original location, checking the alignment, making proper electric connection, testing for smooth operation, complete all as directed. Note : (i) The cost of winding wire and all replaced defective parts are deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. (ii) The cost of transportation (to and fro) and other necessary equipment shall be arranged/brought by contractor to complete the job at site or at repair shop and no extra cost shall be paid to the contractor in this effect.
All as per srl item no 31.00 here-in-above but for 25/30 HP capacity.
All as per srl item no 31.00 here-in-above but for 20 HP capacity.
All as per srl item no 31.00 here-in-above but for 10/12.5 HP capacity.
All as per srl item no 31.00 here-in-above but for 5/7.5 HP capacity.
All as per srl item no 31.00 here-in-above but for 3.0 HP capacity.
M&L for complete overhauling of condenser / chiller centrifugal pumpset of 20 HP by engaging sufficient man power and suitable T&P to ensure safety of pump-motor as well as working persons including disconnecting suction & discharge water lines and removing of electric connection, dismantling the U/S pumpset from MS foundation, detaching the pump, opening the pump, remelting the shaft and filling of metal at decayed portions including all kind of machine works i.e. welding, turning, polishing etc as required to make the shaft of required shape and size, as original, balancing the shaft and refitting in pump body complete incl carrying out complete repair / replacement of damaged parts i.e. bearings, bush, gland plate, gland packing, coupling assembly etc and reassembling the pump after greasing of moving parts and reinstallation of the pump with motor in original location using new MS stud, nut, bolt, washer and other packing material etc; checking the alignment; reconnecting the suction and delivery pipes, making proper electric connection, testing and commissioning for smooth operation at optimum efficiency, complete all as specified and directed.
All as per srl item no 37.00 here-in-before but for 10 /12 HP capacity.
All as per srl item no 37.00 here-in-before but for 5 /7.5 HP capacity.
M&L in replacement Y-type strainer flanged type as per existing 50/80mm dia, complete all as specified and directed by Engineer-in-Charge. Make : Zoloto/Leader /Zenith / Crescent
M&L for dismantling existing water softener and replacement with raw water in to online electrostatic non chemical water treatment system electrically operated control panel to be fixed on sub header/tapping suitable for , the outer casing shall be of 304 grade stainless steel with both ends flanged and capable of preventing scale formation of AC Plants flanged ends including necessary mechanical jointing operation like welding work, nut, bolts and rubber packing with starter panel electronically operated of existing length. Complete all as specified and directed by Engineer-in-Charge. Make: scale off model no 3021 mfg by Weldon Engineers.
M&L for cleaning of all condensor tubes of central AC plant by disconnecting the condensors -02 Nos from the system, cleaning by descaling pump using descaling solution of Make:-MAIC / HIBIRD or Hydrochloric acid 20%, cleaning the system through cooling tower by using descaling solution, cleaning condensor tubes by nylon brushes & mild steel rods of suitable size, renewal of suction water filter for 2x75 TR capacity plant at SCE. complete all as specified and directed by Engineer-in-Charge. (Note:- T&P such as pumps, tube etc & descaling solution etc shall be arranged by the contractor at his own cost.)
M&L for cleaning of all condensor tubes of central AC plant by disconnecting the condensors - 03 Nos from the system, cleaning by descaling pump using descaling solution of Make:-MAIC / HIBIRD or Hydrochloric acid 20%, cleaning the system through cooling tower by using descaling solution, cleaning condensor tubes by nylon brushes & mild steel rods of suitable size, renewal of suction water filter for 3x37.5 TR capacity plant at MH complete all as specified and directed by Engr-in-Charge. (Note:- T&P such as pumps, tube etc & descaling solution etc shall be arranged by the contractor at his own cost.)
Dismantling of burnt fan motor of walk cooler out door unit double shaft and supply & fixing new fan motor (Suitable for Carrier/ Voltas/ Blue star /LG/ Samsung Make AC) as per sample completeg all as specified and directed.
Servicing of IDU (Indoor unit) of ceiling mounted casset type split Air conditioner of 3 TR/4 TR capacity comprising of Blower, blower motor ,water lifting motor, oiling & greasing of moving parts complete all as specified and directed.
Supply and filling in compressor oil for topping up make- servo friz 68/Freezol 68 or as recommonded by the dealer suitable for existing compressor complete all as specified and directed.
S&F in replacement brass suction valve size 3/8" complete all as specified and directed
S&F in replacement Discharge valve size 1/2" complete all as specified and directed .
S&F in replacement ML-1 contractor 240 volt, 25 Amp for split type AC complete all as specified and directed.
S&F in replacement copper capillary of size 0.55 mm complete all as specified and directed.
M&L for Nitrogen pressure testing Flushing out the system by Nitrogen ,vacumrnation and charging of refrigerant gas R-32/R410A into walking cooler unit all as specified and directed. (The refrigerant gas R-32/R410A will be provided by Contractor)
Servicing and overhauling of walk in cooler of any make Blue star Model - PC 1950 with strainer steel product and with two condensing unit installed at any location in cantonment including cleaning and painting internally and externally with two coats of synthetic enamel paint ; reparing/ renewal/replacement of defective parts and component all as specified and directed. Parts renewed shall be measured and paid separately under appropriate items
S&F in replacement of expanssion device of walk in cooler complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of PLC unit of walk in cooler 2 ton capacity complete all as specified and directed. Make: Siemens/ Schnieder
S&F in replacement of PCB circuit of walk in cooler complete all as specified and directed by Engineer-in-Charge.
Removing burnt/defective sealed compressor unit of any make from any type of walk in cooler 1.5/2 ton capacity by cutting of suction and discharge lines unscrewing the foundation nuts, bolts etc, supply amd fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with gas welding/brazing work and tightening foundation nuts & bolts etc complete all as specified and directed.
Repair & replacement for repair to PCB circuit in walk in cooler 1.5/2 ton capacity complete all as specified & directed.
Taking out the existing unserviceable low pressure cut - out switch and supply & fixing new low pressure cut-out switch type. MP - 1 all as specified and directed. (Make:- INDFOSS / RANUTROL)
Taking out the existing unserviceable low pressure cut - out switch and supply & fixing new low pressure cut-out switch type. MP - 5 complete all as specified and directed. (Make:- INDFOSS / RANUTROL)
Taking out the existing defective pilot control solenoid valve and supply & fixing new pilot control solenoid valve complete all as specified and directed (Make: SPORLAIN or as approved by GE.)
Taking out the existing defective loader/ unloader solenoid valve ( Capacity Control solenoid valve) and supply & fixing new loader / unloader solenoid valve complete all as specified and directed. (Make: Nikko / Rotex or equivalent as approved by GE)
M&L (in repairs) single phase preventor to prevent against single phasing, reverse phasing with wiring & testing complete complete all as specified and directed. (Make:- Minilec / Electromed / L&T/ABB/Seimens)
Supply and topup refrigerant gas Non CFC compatible to R-32 in returnable sealed cylinder complete all as specified and directed. (Make:- Floran / Mafron)
Supply and topup refrigerant gas Non CFC compatible to R-407 in returnable sealed cylinder complete all as specified and directed. (Make:- Floran / Mafron/R value)
Supply and topup refrigerant gas Non CFC compatible to R-410 in returnable sealed cylinder complete all as specified and directed. (Make:- Floran / Mafron/R value)
Taking out the existing silica gel flange type filter drier 1/2" x 1/2" dia flare and supply & fixing new filter drier of the same type & size (Make:- Universal / Unistar) including repairs to flare etc complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of return air grill aluminium with powder coated white collers of size 300 mm x 900 mm complete all as specified and directed.
Supply and replacement of air grill MS air control damper of size 300 mm x 900 mm complete all as specified and directed.
M&L for servicing of air curtain by removing the existing choked fins/filters complete all as specified and directed by Engineerr-in-Charge.
Removing burnt/defective sealed compressor unit of any make from any type of air conditioner split/cassele type 3 ton capacity by cutting of suction and discharge lines unscrewing the foundation nuts, bolts etc, supply amd fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with gas welding/brazing work and tightening foundation nuts & bolts etc complete all as specified and directed
S&F in replacement of blower Motor 0.2/0.25 HP for walking cooler/Air curtain complete all as specified and directed. (Make - GE/Crompton/Polar).
S&F in replacement of blower Motor 0.5 HP for walking cooler complete all as specified and directed. (Make - GE/Crompton/Polar)
S&F in replacement of PCB circuit as per existing model of walking cooler all as specified & directed. (Make – Blue Star/Voltas/Carrier)
M&L for removing the existing choked fins of 2x75/3x37.5 TR cap cooling tower and supply and fixing new fins to cooling tower for AC Plant complete all as specified and directed by Engineerr-in-Charge.
S&F capacitors 6 Mfd capacities 2 pin for ACs/ Walk- in- cooler etc complete all as specified and directed by Engieerr-in-Charge. Make:- Asian/Tipcon/Usha/Epcos/Havells
S&F capacitors 10 Mfd capacities 3 pin for ACs/ Walk- in- cooler etc , complete all as specified and directed by Engineer-in-Charge. Make:- Asian/Tipcon/Usha/Epcos/Havells
S&F capacitors 30/40 Mfd capacities 4 pin for ACs/ Walk- in- cooler etc , complete all as specified and directed by Engieer-in-Charge. Make:- Asian/Tipcon/Usha/Epcos/Havells
S&F capacitors 50/60 Mfd capacities 4 /6 pin for ACs/ Walk- in- cooler etc , complete all as specified and directed by Engineer-in-Charge. Make:- Asian/Tipcon/Usha/Epcos/Havells
S&F capacitors 80/100 Mfd capacities 4 pin for ACs/ Walk- in- cooler etc, complete all as specified and directed by Engineer-in-Charge. Make:- Asian/Tipcon/Usha/Epcos/Havells
S&F in replacement of V Belt, 'B' section (17x11mm) of B-29 size, complete all as specified and directed. Make : Fenner / Dunlop.
All as per srl item No. 80.00 here-in-before but B-36 size.
All as per srl item No. 80.00 here-in-before but B-41 size.
S&F of Step Controller with digital display, More than 5 steps, for Hot Water Generator wall as per sample, complete all as specified and directed. Make - Rapid cool / Honeywell.
Quarterly Periodical, preventive & comprehensive maintenance by dis-assembly, repairing, overhauling, servicing & testing of complete inner tank, Elements, inlet and out let pipe, valves of Hot water generator installed at AC plant including descaling, replacement of gaskets complete incl painting with two coat of heat resistant paint of smoke grey colour complete all as specified and directed.
S&F in replacement, of three phase heating element capacity 20KW( set of 06 Nos) capacity, ISI marked of existing shape and size suitable for hot water generator and making electric connections and taking down old unserviceable heating elements, complete all as specified and directed. Make : Daspass / Theata
Quarterly Periodical, preventive & comprehensive maintenance by dis-assembly, repairing, overhauling, servicing & testing of complete industrial RO plant 500 ltrs/hrs system complete with Vessels, filter media, pressure pump & replacement of damage PVC pipe line/ leakage complete and replacement of following parts:
Supply only inreplacement of vessel paintier with filter media for RO plant 500ltrs/hrs complete all as specified and directed.
Supply only Adaptors and SMPS 12 Volt DC complete all as specified and directed.
Supply only UV Components complete all as specified and directed.
Supply only Sand filter media complete all as specified and directed.
Supply only Carbon filter media complete all as specified and directed.
Supply only membrane filter for 500 ltrs/hrs complete all as specified and directed.
S&F in replacement of dosing puimp complete with inlet & out let valve complete all as specified and directed.
S&F Anti scalent chemical complete all as specified and directed.
Quarterly Periodical, preventive & comprehensive maintenance by dis-assembly, repairing, overhauling, servicing & testing of complete industrial RO plant 50 ltrs/hrs system complete with Vessels, filter media, pressure pump & replacement of damage PVC pipe line/ leakage complete and replacement of following parts:
S&F RO Booster Pumps for 50 ltr /hrs complete all as specified and directed.
S&F RO membranes for 50 Ltrs /hrs to remove the major part of TDS up to 98% complete all as specified and directed.
S&F Adaptors DC supply complete all as specified and directed.
S&F UV Components complete all as specified and directed.
S&F carbon filter complete all as specified and directed.
S&F Filter Cartridges complete all as specified and directed.
S&F UF Membranes complete all as specified and directed.
Supply only Single phase preventer with Auto switch . Type- Cat No 2.BSP-2, complete all as specified and directed by Engineer - in - Charge. Make- Bentex / Minilec
Supply only MCCB (AC 415 V) with adjustable thermal & adjustable magnetic setting Four pole 400 Amp 36 KA, complete all as specified and directed by Engineer - in - Charge. Make : GE or equivalent C &S /Legrand.
Supply only MCCB (AC 415 V) with adjustable thermal & adjustable magnetic setting Four pole 320 Amp 36 KA, complete all as specified and directed by Engineer - in - Charge. Make : GE or equivalent C &S /Legrand.
Supply only MCCB of capacity , 250 Amps ,04 pole ,415 V, 36 KA Breaking capacity with fixed thermal magnetic release, complete all as specified and directed by Engineer - in - Charge. Make- GE or equivalent C &S /Legrand
Supply only MCCB 200 A, 4 Pole, 415 V, 36 KA Breaking capacity, with fixed thermal magnetic release, complete all as specified and directed by Engineer- in-Charge. Make- GE or equivalent C &S /Legrand.
Supply only MCCB 100 A, 3 Pole, 415 V, 35 KA Breaking capacity, with fixed thermal magnetic release, complete all as specified and directed by Engineer - in - Charge. Make- GE or equivalent C &S /Legrand.
Supply only Moulded Case Circuit Breaker (MCCB) (AC 415 V) with adjustable thermal & adjustable magnetic setting Three pole 63 Amp 25 KA , complete all as specified and directed by Engineer-in-charge. Make : GE or equivalent C &S /Legrand.
Supply only Motor protection circuit breaker thermal overload relays suitable for ML contactors relay range 10-16A, complete all as specified and directed by Engineer-in-Charge. Make-Havells/L&T/Legrand.
Supply only Power contactor 3 pole Type MNX 18 AC 3 rating 18 A with auxiliary contact 2 NO + 2 NC, complete all as specified and directed by Engineer-in-Charge. Make- L&T/Legrand.
Supply only Power contactor 3 pole Type MNX 70 AC 3 rating 70 A with auxiliary contact 2 NO + 2 NC, complete all as specified and directed by Engineer-in-Charge. Make- L&T cat part No. ST19002 or equivalent in Legrand.
Supply only Power contactor 3 pole Type 3 ML AC 3 rating 40 A with auxiliary contact 2NO + 2NC, complete all as specified and directed by Engineer-in-Charge. Make- L&T cat part No - SS90721 or equivalent in Legrand.
Supply only Power contactor 3 pole Type MNX 25 A AC 3 rating 25 A with auxiliary contact 2NO + 2NC, complete all as specified and directed by Engineer-in-Charge. Make- L&T cat part No - SS90921 or equivalent in Legrand.
Supply only Power contactor 3 pole Type 1.5 ML AC 3 rating 25 A with auxiliary contact 2 NO + 2 NC, Cat No - SS91851 Make- L&T/Legrand.
M&L for replacement of Cable 3 core flexible heavy duty copper cable of size 4 sqmm of AC , Water Cooler, stabilizer etc complete all as specified and directed. (Make-Plaza/Finolex /Polycab)
M&L for replacement of Cable 3 core flexible heavy duty copper cable of size 6 sqmm of AC , Water Cooler, stabilizer etc complete all as specified and directed. (Make-Plaza/Finolex /Polycab)
M&L for shifting/installing Split type Air conditioner of any 3/4 Ton capacity complete with piping and copper tubing arrangements including fixing the suction unit on wall and making good as existing as well as making electric connections all as directed by Engineer-in-charge. Note :- Copper tubing ,drain pipe and other insulation material measured under relevant item).
S&F insulation of copper tubing wherever required complete all as specified & directed by Engineer-in- harge. Note : Insulation of cold&return air copper tuning measured as one running meter.
S&F Copper pipe 20 mm dia with insulation for split AC complete all as specified & directed by Engineer-in-Charge.
S&F Copper pipe 12 mm dia with insulation for split AC complete all as specified & directed by Engineer-in-Charge.
M&L for scraping down, cleaning and preparation of old painted surface, applying one coat of synthetic enamelled paint to AC installation Central type AC Plant 2x75 TR all as per existing colour code including sign writing as directed. (AC installation comprising of compressor, motor condenser, pipe line, panel board, valves, AHU cooling tower, Chillar pipe and display board) marking direction of flow and writing SM Nos and MES Nos of size not less than one inch complete all as specified and directed.
M&L for scraping down, cleaning and preparation of old painted surface, applying one coat of synthetic enamelled paint to AC installation Central type AC Plant 3x37.5 TR all as per existing colour code including sign writing as directed. (AC installation comprising of compressor, motor condenser, pipe line, panel board, valves, AHU cooling tower, Chillar pipe and display board) marking direction of flow and writing SM Nos and MES Nos of size not less than one inch complete all as specified and directed.
Ajanta Associates
M/S SS Tarders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .