Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.1 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹1.3 Cr+₹18.7 L (16.5%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹1.3 Cr+₹18.7 L (16.5%) | L2 | Rejected-Finance Being other than Lowest |
| 3 | L3₹1.3 Cr+₹20.7 L (18.3%)Rejected-Finance | ₹1.3 Cr+₹20.7 L (18.3%) | L3 | Rejected-Finance Being other than Lowest |
| 4 | L4₹1.3 Cr+₹21.0 L (18.5%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | ₹1.3 Cr+₹21.0 L (18.5%) | L4 | Rejected-Finance Being other than Lowest |
| 5 | L5₹1.3 Cr+₹21.4 L (18.9%)Rejected-Finance | ₹1.3 Cr+₹21.4 L (18.9%) | L5 | Rejected-Finance Being other than Lowest |
Tender Value
Refer Docs
Closing Date
3 May 2021, 6:00 pmClosed
CWE NW MUMBAI
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
MANNING OPERATION AND REPAIR ROUTINE MAINTENANCE OF RO PLANT WATER SUMPS INCLUDING PERIODICAL CLEANING AND SUPPLYING OF ESSENTIAL CHEMICALS AND REPAIR ROUTINE MAINTENANCE OF AC PLANTS AT INS SHIKRA BOAT POOL AND CONNECTED WORKS AND REPAIR REP
2021_MES_432435_1
8662/CWE(NW)/MUMBAI
Open Tender
Civil Works
Item Rate
330 days
GE (NW) NOFRA
Class B and above
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) NOFRA
Exempted
12 Jun 2021
23 Mar 2021
5 May 2021
23 Mar 2021
3 May 2021
28 Apr 2021
23 Mar 2021 - 14 Apr 2021
Amount
PART-I Manning and Operation of R.O Plant in three shifts round the clock 0600 hrs to 1400 hrs, 1400 hrs to 2200 hrs and 2200 hrs to 0600 Hrs including sunday and holiday with cleaning and up keep of the installation operating the submersible pump installed in raw water bore well -02 Nos and operation of treated water pump set including taking care from any pilferage, theft or damage of RO plant etc complete all as specified and directed by Engineer-in-Charge. Notes :- (i) RO operator : 01 No per shift (ii) RO Plants- 02 Nos. (iii) Quoted rate shall be deemed to be for the both RO Plant and shall have out put water capacity not less than 40,000 liters per day. (iv) The Quality of out put water shall confirm to IS 10500 of 1991.
PART-II Routine maintenance of RO plants No. 1 & 2 installed at Vandana and Vishakha complex having out put capacity of drinking water not less than 40,000 ltrs / day, maintenance of chlorine dosing system,coagulant dosing system,antiscalant dosing system carrying out the routine maintenance recommended by the manufacturer for daily, weekly, monthly and quarterly including repairs/ replacement of parts such as bearings, repairs of pumps, filters, welding of cracked/ broken any mild steel items/ foundation, PVC pipes and their fittings, LT panel boards etc complete including painting to all equipment with synthetic enamelled paint complete and all as specified & directed by Engineer-in-Charge including testing of treated water in the approved laboratory for bacteriological test and potability test for every month. Notes :- (a) Chemicals required for operation of RO plant will be measured and paid seperately under Schedule 'A' Part - III of this BOQ (b) RO Plant shall be maintained for smooth functioning and for out put capacity of drinking water not less than 40,000 liters / per day.
PART-III Material and labour for overhauling and including replacement of minor spare parts of submercible pump installed at Vandana and Vishakha complex complete all as specified and directed by Engineer-in-Charge.
Supply only Antiscalant chemical (Make : Aquachem /Acqua filtron/GE )
Supply only cleaning Chemical (Make: Aquachem/Agua pure/GE )
Supply only Calcium Hypochlorite in granular form in 45 Kg drum, having minimum 70% of available chlorine (Ca(OCI)) with anti-corrosive and anti-scaling properties suitable for human consumption. Make: PuriChlor (SRHSH)/ or equivalent as approved by GE. Note: Contractor shall produce letter of authorisation, COA with unique serial number and NSF certiifcate from manufactuer
Disconnecting and taking out unserviceable multiple valve and supply fix with new multiple valve of RO plant complete to match the existing and connecting up with existing system including all accessories complete all as specified and directed by Engineer-in-Charge. Make :- DEWS Aircon / Flow Max / Initiative
Disconnecting and taking out unserviceable cartridge filter and supply fix with new cartridge filter of RO plant complete to match the existing and connecting up with exisiting system including all accessories complete all as specified and directed by Engineer-in-Charge
Disconnecting and taking out unserviceable carbon filter and supply fix with new Carbon filter of RO plant complete to match the existing and connecting up with exisiting system including all accessories complete all as specified and directed by Engineer-in-Charge
Taking out old unserviceable membranes and supply & fix new Reverse Osmosis Membrane all as specified and directed by Engineer-in-Charge. Make: Hydranautic/GE/ DOW/CSM
Disconnecting and taking out unserviceable control panel and supply fix with new control panel for RO plant complete to match the existing and connecting up with existing control / electric system including all accessories complete all as specified and directed by Engineer-in-Charge.
Supply and demonstration of chlorine residual test kit portable digitally operated range 0.1-1 PPM and 0.6 to 6 PPM with enclosure & orthodin solution bottle 500 ml capacity complete all as spificied and directed.
Supply and fix in repair LT Cable on wall/floor/ceiling with proper saddles, including testing of XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 2.5 sq mm 3 core complete all as spificied and directed.
Taking down old existing CPVC pipes , supply & lay CPVC pipes medium grade with all fittings laid in floors or fixed to walls and ceilings etc. of size 40 mm dia complete all as spificied and directed. Make:prince/sudhakar/Ashirvad
Disconnecting and taking out unserviceable FRP Housing of membrane and supply fix with new FRP Housing of membrane for supporting and balanceing existing membrane of RO plant complete to match the existing and connecting up with existing system including all accessories complete all as specified and directed by Engineer-in-Charge.
Part -IV Manning & operation of Central AC Plant two in number 32.5 TR make Kirloskar run at a time one compressor and one stand by for smooth functioning of entire system and to maintain the specific temperature 20+2ºC, RH 50+5% AC plant consists of the following items fitting/ fixtures/ device components for operation at Epoxy coating workshop boat pool 8hrs daily including Sunday and Holiday in one shift.(i.e 0800 To 1600 Hrs) one AC plant operator per shift and taking care cleaning etc any pilferage, theft or damage etc complete all as directed:- (a) Compressor make Kirloskar -02Nos. (b) Compressor motor HBB 50HP-02Nos. (c) Condenser water pump set mono block 7.5HP - 02 Nos. (d) Air handling unit with blower motor 10HP-01No. (e) AHU motor 10HP HBB-01No. (f) Cooling tower induced draft type -01No. (g) Electrical control panel cubical type floor mounted with maint switch MCBs voltmeter, Ammeter, Starter condenser etc. complete-01Set. (h) Control devices such as expansion valve thermostat solenoid valves HP/LP/CP cuts out with panel board installed gauges-01 Set (j) Digit type thermometer-01Set (k) Air supply duct with grill diffusers, dampers and heater etc. complete-01Set (l) Condensor MS piping 100mm with valves, pressure gauge, temperature gauge complete-01Set
Manning & operation of Central AC Plant of water cooled chillers 3Nos. x 50 TR (Two running,one standby) Total 150 TR make: voltas for smooth functioning of entire system and to maintain temperature of AC plant consists of the following items fitting/ fixtures/ device components for operation at INS SHIKRA . 16 hrs daily including Sunday and Holiday in two shift.(i.e 0600 to 1400 Hrs,1400 to 2200 Hrs ) one AC plant operator per shift and taking care cleaning etc any pilferage, theft or damage etc complete for the following:- (a) Compressor model No. ACCWC05000MNT-03 Nos. (b) Compressor motor 60HP-03Nos (c) Condenser / chiller water pump set mono block 10/7.5HP-04Nos. (d) Air handling unit with blower motor -01No. (e) FRP Cooling tower with CT Fan-01No. (f) Control devices such as expansion valve thermostat solenoid valves HP/LP/CP cut outs with panel board installed gauges -01Set. (g) Digit type thermometer-01 Set. (h) Air supply duct with grill diffusers dampers and heater etc. complete-01Set. (j) Condenser piping MS 100/80/50mm dia with valves, pressure gauge, temperature gauge -01Set
PART-V Comprehensive maintenance including Sunday and Holiday of Central Air conditioning Plant of capacity 32.5TR X 2Nos comprising of following equipment mentioned under including cleaning, securing, gearing the merable parts of pump motors and painting of plants motor, cooling towers and pipes, cleaning of cooling tower etc complete all as specified and directed by Engineer-in-Charge at Boat Pool Workshop:- (a) Compressor make Kirloskar -02Nos. (b) Compressor motor HBB 50HP-02Nos. (c) Condenser water pump set mono block 7.5HP - 02 Nos. (d) Air handling unit with blower motor 10HP-01No. (e) AHU motor 10HP HBB-01No. (f) Cooling tower induced draft type -01No. (g) Electrical control panel cubical type floor mounted with maint switch MCBs voltmeter, Ammeter, Starter condenser etc. complete-01Set. (h) Control devices such as expansion valve thermostat solenoid valves HP/LP/CP cuts out with panel board installed gauges-01 Set (j) Digit type thermometer-01Set (k) Air supply duet with grill diffusers, dampers and heater etc. complete-01Set (l) Condensor MS piping 100mm with valves, pressure gauge, temperature gauge complete-01Set
Comprehensive maintenance inclduing Sundays & Holidays of central AC plant of water cooled chillers 3Nos. x 50 TR (Two running,one standby) Total 100 TR make: voltas, model No. AC WC05000MNT at INS SHIKRA complete with cooling tower AHU & other accessories for for the following:- (a) Compressor model No. ACCWC05000MNT-03 Nos. (b) Compressor motor 60HP-03Nos. (c) Condenser / chiller water pump set mono block 10/7.5HP-04Nos. (d) Air handling unit with blower motor -01No. (e) FRP Cooling tower with CT Fan-01No. (f) Control devices such as expansion valve thermostat solenoid valves HP/LP/CP cut outs with panel board installed gauges -01Set. (g) Digit type thermometer-01 Set. (h) Air supply duet with grill diffusers dampers and heater etc. complete-01Set. (j) Condenser piping MS 100/80/50mm dia with valves, pressure gauge, temperature gauge -01Set.
PART-VI Material and labour for pumping down and transfer existing refrigerant gas of compressor complete for over hauling of compressor, reciprocating open type Model No. AC- 470 Make:Kirloskar 32.5Ton capacity and dismantling complete assembly & replacing of minor unserviceable parts including matching of crank shaft boring polishing etc. replacing of gaskets packing reassembly and recharging of pumped down refrigerant & topping up if required, maintain the required standing pressure charging of compressor oil complete testing for smooth functioning etc complete all as specified and directed by Engineer-in-Charge at Epoxy work shop Boat Pool. Note: (Major spare parts, compressor oil and refrigerant for topping up will be measured and paid seperately herein after as supply only).
Material and labour for pumping down and transfer existing refrigerant gas of compressor complete for over hauling of compressor, reciprocating open type Model No. 5H20 Make:Voltas 50Ton capacity and dismantling complete assembly & replacing of minor unserviceable parts including matching of crank shaft boring polishing etc. replacing of gaskets packing reassembly and recharging of pumped down refrigerant & topping up if required, maintain the required standing pressure charging of compressor oil complete testing for smooth functioning etc complete all as specified and directed by Engineer-in-Charge at INS Shikra. Note: (Major spare parts, compressor oil and refrigerant for topping up will be measured and paid seperately herein after as supply only).
Supply only following items for compressor reciprocating model No AC-470. Make :- Kirloakar 32.5 ton and compressor reciprocating model No.5H20 Make :- Voltas 50 ton capacity
Main bearing
Liner assembly
Piston rings
Piston Oil rings
Piston pins
Suction valve reeds
Suction valve reed springs
Discharge valve reeds
Discharge valve reed spring
Discharge valve guide assembly
Connecting Rod
Oil filter inner/ outer
Discharge valve retaining plate
Piston
Oil regulating valve
Connecting rod bearing of two
Loading/ unloading valves
Loading/ unloading rings
Crankshaft
Oil pump Assembly
Oil pump bush
Solenoid coil valve assembly
Taking down old unserviceable shaft seal assembly complete and supply and fix new shaft seal assembly suitable for 32.5 TR capacity central AC Plant all as directed by Engineer-in-Charge
Taking down old unserviceable shaft seal assembly complete and supply and fix new shaft seal assembly suitable for 50TR capacity central AC Plant all as directed by Engineer-in-Charge
Material and labour for expansion valve of AC plant capacity 32.5TR including taking down unserviceable valve complete all as specified and directed by Engineer-in-Charge at Boat pool. Make : Sporlon or equivalent
Material and labour for expansion valve model no- MV-52 of AC plant capacity 50TR including taking down unserviceable valve complete all as specified and directed by Engineer-in-Charge at Boat pool. Make : Sporlon or equivalent
Material and labour for pumping down the plant to preserve the existing in refrigerant gas & leak testing of plant by charging of nitrogen gas in to entire plant & monitoring for 24hrs to find the leakages, rectification of leak by brazing & replacement of necessary gasket packing wherever required including copper tubes of suitable size vacumising of the plant by vacum pump & keeping 24hrs for testing including rectification of leakages if any finally recharging of existing refrigerant gas to the plant and topping up of refrigerant if required to maintain the standard pressure complete testing of the plant for smooth functioning complete all as specified & as directed by Engineer-in-Charge.
Dismantling/Disconnecting AHU of 3 x 50TR capacity AC plant carefully by removing side and top panel removing unserviceable blower shaft bearings,removing motor & blower assembly, replacement of new AHU blower shaft bearings reassembling blower assembly and refixing electric motor & top side panel in original position with new nut bolts washers & shafts keys & checking the shafts balancing & testing for smooth running all as specified and directed at INS SHIKRA.
Removing the unserviceable liquid line valve of size 25mm dia from the liquid line after pumping down the compressor & supply and fixing new liquid line valve 25mm dia including connected works as required for smooth functioning of AC plants complete all as specified and directed by Engineer-in-Charge
Material and labour for dismantling FRP cooling tower of capacity 50x3 TR at INS Shikra by removing CT Fans, sprinklers, PVC filler and clean cooling tower body by removing scale , dust, dirt and refix PVC filler by cleaning with diluted HCL solution reassembling, connecting , cleaning external surface and applying two coats of approved synthetic enamel paint including writing SM number/ marking and testing etc. complete all as specified and directed
Taking out old unserviceable cooling tower fills sheets of 3X50 TR from the site and supply and fix new fibre fills sheet of same size for cooling tower as per the existing at site and all as specified and directed at INS Sikra AC Plant
Taking out old unserviceable cooling tower nozzles and supply and fix new cooling tower nozzles suitable for 3x 50 TR Mihir make cooling tower as per existing at INS Shikra
Material and labour for disconnecting condenser for descaling, plugging them & providing of 15mm tee out let for local circulation of mild acid solution in the condenser (separate container and small pump set to circulate diluted acid solution to be used) PH value of solution to be circulated & to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be used for descaling purpose after 2 to 3 hours of cleaning if ph value remains less than 7flush with fresh water mixed with sodium carbonate tubes and cleaning with nylonbrush after closing the end covers, circulating diluted acid solution as specified above, to maintaine PH value as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure complete all as specified & directed by Engineer-in-Charge.
Replacement of Compressor Oil with new Compressor oil of Frizol 68 all as specified and directed by Engineer-in-Charge.
Removing old unserviceable discharge valve 25mm dia and supply and fix new discharge valve of size 25mm dia suitable for R-22 gas discharge line all as specified & directed.
Supply and fix in replacement of unserviceable / wornout 'V' belt of compressor, AHU etc of make fenner Dunlop / Nurlon as approved
Taking down old existing MS pipes, supply, lay and welding MS pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc. of sizes 125 mm dia
Taking down old existing MS pipes, supply, lay and welding MS pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc. of sizes 100 mm dia
Taking down old existing MS pipes, supply, lay and welding MS pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc. of sizes 80 mm dia
Taking down old existing GI pipes, supply, lay and welding GI pipes medium grade with all fittings laid in floors or fixed to walls and ceilings etc. sizes of 100 mm dia:
Taking down old existing GI pipes, supply, lay and welding GI pipes medium grade with all fittings laid in floors or fixed to walls and ceilings etc. sizes of 80 mm dia:
Taking down old existing GI pipes, supply, lay and welding GI pipes medium grade with all fittings laid in floors or fixed to walls and ceilings etc. sizes of 50 mm dia:
Removing the unserviceable solenoid valve 5/8" flare from the liquid line and supply and fix new solenoid valve 5/8" suitable for AC plant of various capacities complete with all as specified and as directed by Engineer-in-Charge
Supply and fix in repairs CI Butter fly valve slim seal design with nitrile rubber lined seal with clutch lever (P10 or PN 16) as per IS 13095 of size 125 mm bore .Make: AUDCO/SANT/SIR as approved.
All as per item No 44.00 above but 100 mm bore.
All as per item No 44.00 above but 80 mm bore.
All as per item No 44.00 above but 50 mm bore.
Taking down old unserviceable Non Return valve and supply and fix new CI Non Return valve of size 100 mm Bore. Make: -Kirloskar /Kartar/Zolota/Leader as approved
All as per item No 48.00 above but 80 mm bore.
All as per item No 48.00 above but 50 mm bore.
Taking down old unserviceable Strainer of any make and size and supply and fix new Strainer of size 100 mm Bore.Kirloskar /Hammer/Zolota/Leader as approved
All as per item No 51.00 above but 80 mm bore.
Supply and fix Condensor safety valve suitable for chiller unit all as specified and directed by Engineer-in-Charge.
Removing old unserviceable over load relay assembly and supply fixing new overload relay assembly of same make and capacity all as directed.Make: L & T or its equivalent
Removing old unserviceable timer and supply & fix NewTimer with suitable for existing make OF L&T for Condenser motor all as specified & directed.
Supply and charge refrigerant Gas of R22 as per requirement. Make- Mafron/Ferron as approved by GE.
Removing old unserviceable power contactor and supply & fix new power contactor 3TF-47 all as specified & directed by Engineer-in-Charge Make : Siemens or equivalent
Removing old unserviceable power contactor ML-2 and supply & fixing new power contactor ML-2 all as specified & directed.Make:L&T/Siemens/BCH
Removing old unserviceable power contactor ML-3 and supply & fixing new power contactor ML-3 all as specified & directed. Make:L&T/Siemens/BCH
Removing old unserviceable Auxilary contactor and supply & fix new Auxilary contactor all as specified & directed by Engineer-in-Charge. Make : L & T or equivalent
Removing old unserviceable power contactor and supply & fix new power contactor MNX -32 all as specified & directed by Engineer-in-Charge Make : L & T or equivalent
Removing the unserviceable pressure gauges HP/LP/OP from existing position and supply and fixing new pressure gauge of capacity 0 to 30Kg. / square centimeter complete with necessary accessories all as specified & directed by Engineer-in-Charge
Removing the unserviceable water pressure gauges from water line & supplying and fixing new water meter up to pressure 0-7Kg. / square centimeter complete with necessary accessories all as specified & directed by Engineer-in-Charge
Material and labour for scraping cleaning & preparation of external surface & painting complete installation of 32.5 x 2 TR (65TR capacity) including compressor, motor, piping, cooling tower, condensor, AHU & panel board etc with two coats of synthetic enamel paint over a coat of primer as per direction on colour code as given including writing SM & MES numbers complete all as per specified & as directed by Engineer-in-Charge
Material and labour for scraping cleaning & preparation of external surface & painting complete installation of 50 x 3 TR (150TR capacity) including compressor, motor, piping, cooling tower, condensor, AHU & panel board etc with two coats of synthetic enamel paint over a coat of primer as per direction on colour code as given including writing SM & MES numbers complete all as per specified & as directed by Engineer-in-Charge
Material and labour for disconnecting for Chiller descaling & Plugging them & providing of 15 mm tee outlet for local circulation of mild acid solution in the Chiller (separate container and small pump set to circulate diluted acid solution to be used) PH value of solution to be circulated & to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be used for descaling purpose after 2 to 3 hours of cleaning if ph value remains less than 7, flush with fresh water mixed with sodium carbonate tubes and cleaning with nylon brush after closing the end covers, circulating diluted acid solution as specified above & PH value to be maintained as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure of 3x50 TR capacity at INS Shikra ACplant complete all as specified & directed by Engineer-in-Charge.
Material and labour for replacement to Microprocessor alongwith circuit board as per site of 50 TR Capacity chiller unit including replacing diods , transistors and wiring etc for AC Plant at INS SHIKRA all as specified and directed
Material & Labour for LP/HP/OP cut out KP-1 Including taking down old one. Make:- Indofoss
Removing the unserviceable solenoid coil and Supply and fix new solenoid coil suitable for AC plant of various capacities complete with all as specified and as directed
Removing the unserviceable chiller water sensor and supplying and fixing new chiller water Sensor of suitable capacity complet all as specified & directed by Engineer-in-Charge
Removing the unserviceable pressure Sensor HP / LP / OP from and supplying and fixing new pressure Sensor of suitable capacity complet all as specified & directed by Engineer-in-Charge
Supply and errect factory fabricated rectangular square duct made out of 24 gauge GI sheet in L shaped hollow profile including all accessories such as corner, carriage bolt hangers, gasket and seal the longitudinal joints with and including approved sealant complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable insulation from any surface and supply and fix nitrile rubber insulation of one layer of 19mm thickness sticking on surface by using approved adhesive and sealing the joints by weather proof tape all as directed by Engineer-in-Charge.
Supply and fix in repairs leather type canvas in AHU duct of any size as per existing at site complete all as specified and directed
Taking down old unserviceable AHU pre filter and Supply and fix new pre filters (EU-4)synthetic non oven type efficiency 90% down to particular size of 10 micron double knitted twisted polymer fabric (washable) rated with press drop of 6 mm WC to be mounted in AHU filter assembly size as per existing complete all as specified and directed. Make: ASPAWYMAN/DYNA/MHP
Material and labour for framed work with structural steel sections including nuts, bolts,washers, welding ,bending cold or hot, drilling holes for bolts, in any shape or size as directed including applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Supply and fix Display board of size (4x 3) feet with printing Plant Capacity, date of Installation etc. letter in board including aluminium frame out side the board and fixing on wall complete all as specified and directed.
Rewinding of unserviceable electric motor 3 phase 50 Hz 415volt of following capacity pump set complete comprises as under :- (a) Disconnecting & removing the electric motor from installed position including, loading, unloading and transporting to approved workshop. (b) Taking out the existing burnt winding from the motor including rewinding complete with super enameled copper winding wire of existing gauge including all insulating material such as insulation paper, sleeves, tape, varnish etc. complete for class 'F' insulation. (c) Transporting the motor back to the location, reinstalling in original position including alignment, electrical & water connection, commissioning and testing for 8hours continuously to check the RPM etc. to the satisfactory performance etc. complete. NOTE: Any damage caused during handling will be made good by contractor without any extra cost to department
20 HP Chiller Water Pump Motor .
15 HP Condenser Water Pump Motor.
5.0 HP Condenser Water Pump Motor.
50 HP Compressor Motor .
60 HP Compressor Motor .
10 HP AHU Blower Motor .
Over hauling of Monoblock pump set after removing from the base plate, disconnecting from pipe line, dismantling the pump set, replacing unserviceable gland packing, gun metal bush bearing water seal applying grease etc. complete and reassembling the pump set connecting with pipe line reconnection of electric supply, including buts bolts, gaskets etc. complete testing of pumps for smooth functioning with following capacity of pumps and motors:-
20 HP Chiller Water Pump Motor .
15 HP Condenser Water Pump Motor.
5.0 HP Condenser Water Pump Motor.
50 HP Compressor Motor .
60 HP Compressor Motor .
10 HP AHU Blower Motor .
Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type OCB trolly of rupturing capacity 250 MVA, 400 Amps from location and repair /overhauling and carrying out with the following and all as specified and directed by Engineer-in-Charge. Note: spare parts and new transformer oil shall be measured & paid seperatly .
(i) Inspecting/overhauling of spring drive mechanism by checking mechanism, hold on catch assembly,trip bridge, z srew, Cam U, Aluminum trip bridge, Main trip lever assembly and apply multi grease lubricant to function smoothly. (ii) Inspecting / overhauling of OLTLF assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system. (iii) Inspecting / overhauling / cleaning and inspecting insulators, moving contacts ,fixed contacts,arcing chamber by carbon cleaner solution and apply dry graphite conductive sealant for contacts to avoid carbon deposits on contact surfaces. (iv) Inspecting/Cleaning of oil tank inside and out side surface by CRC throughly and replacement of transformer oil (60 litre for each OCB) and apply heavy duty grease for tank raising/lowering guide. (v) Assembling all items/components parts to the respective position & testing the breaker with High Voltage and Meggering before and after high voltage test complete.
Material and labour for painting of HT OCB capacity 250/350MVA,11KV, 400Amps, with one coat of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities for out side surface and in side surface of OCB all as per specified and as directed by Engineer-in-charge.
Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350 MVA, 400/630/800 Amps from location and repair /overhauling and carrying out with the following all as specified and directed by Engineer-in-Charge. Note: spare parts will be measured & paid seperately under respective item of schedule.
(i) Inspecting / overhauling of manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly. (ii) Inspecting / overhauling of tripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system. (iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptors by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces. (iv) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC) and meggering before and after high voltage test complete.
Material and labour for painting of HT VCB capacity 250/350MVA,11KV, 400/630/800Amps, with one coat of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities for out side surface and in side surface of OCB and all as specified and as directed by Engineer-in-charge.
Material and labour of Opening the bus -bar chamber,CT chamber, PT Chamber and Meter chamber of HT 11KV, panel board and carry out following and all as directed and specified by Engineer-in-Charge. Note: spare parts shall be measured & paid seperately.
Overhauling and secondary injection of over current earth fault relays/release on each multiple setting readjustment by artificial load complete all as specified including testing complete.
Dismantling, overhauling and testing Potential transformer capacity 11 KV / 110 volts AC and replacement of worn out spares such as contacts, bushing, control wiring fibre plates, gaskets , transformer oil and applying multi grease to the mechenical parts & dry graphite conductive sealant to contacts etc & re-assembling the same and commissioning complete all as specified and directed by Engineer-in-Charge. (Note : Spare parts and oil will be measured and paid seperately)
Testing of dielectric strength of transformer oil of indoor type transformer, 11KV/433 volt, filteration of transformer oil by passing through filtration plant to remove moisture, impurities and improving di-electic strength to above 40 KV for 1 minute including new transformer oil for toping up & testing after filtration complete as specified. (Note: Transformer oil will be measured & paid seperately.)
Supply and toping of transformer oil with 50KV di-electric strength complete all as specified. Make: Power /Asian/Savita/Electric.
Supply and fixing in repair of breather with 500 Grams celica gel of indoor type transformer 300KVA/400/500 KVA, all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of thermometer(oil temperature gauge) for indoor type transformer, all as specified and directed by Engineer -in -Charge.
Material and labour for Spray Painting of Transformer of following capacity,indoor type with Two coats of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities and all as specified and as directed by Engineer-in-charge.
Transformer 630KVA - 750 KVA ,11KV/433Volt
Transformer 500KVA ,11KV/433Volt
Transformer 400 KVA ,11KV/433Volt.
Transformer 315 KVA ,11KV/433Volt.
Transformer 200 KVA ,11KV/433Volt.
Material and labour for Disconnecting of LT and HT cable carefully from Transformer and draining out transformer oil, dismantling transformer top cover and dismantling of 4Nos LT bushing and 3Nos of HT bushing including necessary tools and plant for removal of sediments,carbon deposits at bottom of transformer tank, on core,on winding etc cleaning with new transformer oil including of cleaning of oil tank and attending leakage problem with oil seal and all gaskets and re assembling complete all as directed.(Note : New Transformer oil and spare parts will be measured and paid separatley excluding oil seal)
Transformer 630KVA - 750 KVA ,11KV/433Volt
Transformer 500KVA ,11KV/433Volt
Transformer 400 KVA ,11KV/433Volt.
Transformer 315 KVA ,11KV/433Volt.
Transformer 250 KVA ,11KV/433Volt.
Material and labour for Burnt out Studs and bushing with nuts of any material by providing new copper alloy stud with nut,washers and bushing on HT Side all as directed for following capacity transformers:-
Transformer 630KVA - 750 KVA ,11KV/433Volt
Transformer 500KVA ,11KV/433Volt
Transformer 400 KVA ,11KV/433Volt.
Transformer 315 KVA ,11KV/433Volt.
Transformer 250 KVA ,11KV/433Volt.
Material and labour for Burnt out Studs and Bushing with nuts of any material by providing new copper alloy stud with nut,washers and bushing on LT Side all as directed for following capacity transformers:-
Transformer 630KVA - 750 KVA ,11KV/433Volt
Transformer 500KVA ,11KV/433Volt
Transformer 400 KVA ,11KV/433Volt.
Transformer 315 KVA ,11KV/433Volt.
Transformer 250 KVA ,11KV/433Volt.
Supply and fix in repair cooling fins of transformer of capacity 750 KVA as per manufacturer's specifications and standard practice and all as directed.
Supply and fix in repair cooling fins of transformer of capacity 400/500 KVA as per manufacturer's specifications and standard practice and all as directed.
Material and labour for loading into truck of faulty Transformer of capacity 250 KVA to 500 KVA with the help of Crain and shifting from site to factory premises and unloading all as directed
Material and labour for loading into truck of Transformer capacity 250KVA to 500KVA after caary out the repair with the help of Crain and shifting from factory premises to site and unloading and shifting to inside the sub station and connecting all HT and LT cable connections and earthing connections and all as directed.
Material and labour for Dismantling the Core and taking out along with windings and cleaning oil tank of transformer 250 to 500KVA, 11KV/415Volts and removing sludges from tank, manufacturers specifications and standard practice and all as directed. (Note: Transformer Oil will be measured and paid seperately).
Material and Labour for Dismantling the faulty HV winding carefully from transformer of any type and capacity11KV/433Volts from core and rewinding the HV winding with suitable size of insulated copper wire as per manufacturers specifications and standard practice and all as directed.
Material and Labour for Dismantling the faulty LV winding carefully from transformer of any type and capacity,11KV/433Volts from core and re winding the LV winding with suitable size of insulated copper wire and as per manufacturers specifications and standard practice and all as directed.
Material and labour for reinsulating the HV winding with DPC insulation and as per manufacturers specifications and standard practice and all as directed.
Material and labour for reinsulating the LV winding with DPC insulation and as per manufacturers specifications and standard practice and all as directed.
Material and labour for refixing the core and windings assembly with insulating material and hardware of Transformer of any capacity and type,11KV/433Volts in to the oil tank with suitable fixing arrangements and re connecting HV and LV internal connections to HV and LV bushings and replacing gaskets of bushings,bottom and top valve, top cover, conservator and replacing celica gel breather and fixing top cover with conservators and reassembling all parts respect to original position and refilling of new transformer oil and filler to achieve the BDV Values and testing as per manufacturers specifications and standard practice and all as directed. (Note: transformer oil will be measured & paid seperately)
Supply and fix in repair of spout insulator assembly for HT OCB 11 KV , 400 amps indoor type with current carrying parts complete all as specified and directed by Engineer-in-Charge.
Supply, fixing in repair of OCB through insulator assembly with current carrying parts for OCB, 11KV, 400Amps, indoor type and all as specified and directed.
Supply, fixing in repair of OCB oil tank gasket 3mm thick suitabale for OCB, 11KV, 400Amps, indoor type and all as specified and directed.
Supply and fix in repair of following Spare parts suitble Make Areva/Schnieder or any existing make/model ,VCB 11 KV , 630 amps indoor type complete all as specified and directed by Engineer-in-Charge.
Opening / Closing Push Button Assembly
Motor Charding mechanism gear box
Limit Switches
Closing Coil Assembyl
Tripping Coil assembly
Spring Charging Motor
Auxiliary Switch with link
Spring return latch
Vaccum Interupter assembly Make: Siemens/Areva/existing sample as approved by GE.
Spout Insulator assembly (3Phase) feeder side
Spout Insulator assembly (3Phase) Bus barr side
Potential Transformer,11KV/110Volt/Rout3,100VA burden Trolly mounted with HRC Fuse . Make: Siemens/Areva/ ABB/Schneider/existing sample as approved by GE.
Current Transformers,50-30,5+5Amps, Class1 and 5p10,15VA,18.3kA/3Sec Make: Siemens/Areva/ ABB/Schneider/existing sample as approved by GE.
TNC Switch
Indicating Lamps LED type
Supply and fix in repair of following Spare parts suitble Make Areva/Schnieder or any existing make/model ,VCB 11 KV , 630 amps indoor type complete all as specified and directed by Engineer-in-Charge.
Voltmeter Digital Type PTR 11KV/110Volt,96x96mm Make: Siemens/Areva/ABB/Schneider/As per existing model approved by GE.
Ammeter Digital Type PTR 11KV/110Volt,96x96mm Make: Siemens/Areva/ABB/Schneider/As per existing model approved by GE.
Indicating Lamps LED type
Supply & fix in repairs strip type heater 80watt with control wiring suitable for indoor OCB/VCB,11 KV switch gear Panel board complete all as specified and directed by Engr-in-Charge.
Supply & fix in repairs indicating lamp holder with bulb LED(Red Yellow,Blue,Green) type to indicate incoming supply suitable for 24 V DC/110 VAC/230Volts AC and all as specified and directed. Make:Teknic/ C&S /L&T
Dismantling Air Circuit Breaker 4pole/3pole, 630Amps to 1200Amps, 415 Volts, draw out/fixed type from location and repair /overhauling of spring drive mechanism, coil, auxiliary switch including setting of over load coil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspecting male and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective position and testing complete all as specified and directed by Engineer-in-Charge.(Note : Spare parts will be measured and paid separately)
Supply , fixing ,test and commissionning in repair in existing panel ACB. 3Pole, 630Amps ,MDO ,50KA suitable for 415V, 3phase, AC supply including necessary modification in panel with 2mm thick CRCA sheet door and suitable size of Copper bus bar as per existing model/sample and all specified and directed. Make : Schneider/L&T/C&S/Havells/HPL / Legrand.
Material & Labour for repairs/ Overhauling/Servicing to Existing LT electric panels Indoor type of each Transformer by taking shut down from appropiate authority including following(i) loose connections and tight connection and cleaning inside/out side all con replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors ,providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting (silver colour) / powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge all as directd and specified. (Note: The tenders quoted rate per unit shall deemed to be inclusive of taking out burnt ACB/ MCB/MCCB/Voltmeter/Ampermeter/CT/LED lamps of any type and discription etc and refixing the same,which shall be measured and paid as supply only vide relivent items of this schedule.)
(i) Cleaning inside the panel and all incoming and out going feeders i.e incling MCCB/SFU/Changeover switches/Contactors/ ACB,s thorouly with help of Vaccum Cleaner. (ii) Checking the loose connections of incoming and out going feeders and rectifify the same with help of new GI nut bolts and washers (iii) Replaceing the burnt out coluor coated PVC Sleeve of main and fedders bus with appropriated size of New PVC heat shrinkable sleeves -01Job (iv) Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/Hrc Fuses.(Note: New items will be measured and paid separatly)-01Job (v) Replacing burnt out contrle wiring of Ammeter/Voltmeter/Indicating lamps and CT'swith 2.5/1.5Sqmm copper sinhel core,1100V grade copper conductor cable- 01Job (vi) Replacing Burnt out Bus Bar of incomming and out going feededs with approprieted size new bus bar (Copper/Aluminum) -01Job( Note : Bus Bar will measured and paid separately) (vii) Replacing Burnt out Insulators of incomming and out going feededs with approprieted size new Insulators -01Job( Note : Insulators will measured and paid separately) (vii) Re welding of Doors as directed.
Material & Labour for repairs/ Overhauling/Servicing to Existing LT electric FBB Out door type of each Transformer by taking shut down from appropiate authority including following(i) loose connections and tight connection and cleaning inside/out side all con replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors ,providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting (silver colour) / powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge all as directd and specified. (Note: The tenders quoted rate per unit shall deemed to be inclusive of taking out burnt ACB/ MCB/MCCB/Voltmeter/Ampermeter/CT/LED lamps of any type and discription etc and refixing the same,which shall be measured and paid as supply only vide relivent items of this schedule.)
(i) Cleaning inside the panel and all incoming and out going feeders i.e incling MCCB/SFU/Changeover switches/Contactors/ ACB,s thorouly with help of Vaccum Cleaner. (ii) Checking the loose connections of incoming and out going feeders and rectifify the same with help of new GI nut bolts and washers (iii) Replaceing the burnt out coluor coated PVC Sleeve of main and fedders bus with appropriated size of New PVC heat shrinkable sleeves -01Job (iv) Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/Hrc Fuses.(Note: New items will be measured and paid separatly)-01Job (v) Replacing burnt out contrle wiring of Ammeter/Voltmeter/Indicating lamps and CT'swith 2.5/1.5Sqmm copper sinhel core,1100V grade copper conductor cable- 01Job (vi) Replacing Burnt out Bus Bar of incomming and out going feededs with approprieted size new bus bar (Copper/Aluminum) -01Job( Note : Bus Bar will measured and paid separately) (vi) Replacing Burnt out Insulators of incomming and out going feededs with approprieted size new Insulators -01Job( Note : Insulators will measured and paid separately) (vii) Re welding of Doors as directed.
S&F Aluminium Bus Bar strip with insulation, of any size, for extention of MCCB terminals for cable terminations, inside the cable alley of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size complete all as specified and as directed . Note :- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs. (b) Overall length of the strip shall be measured and paid after necessary conversion into weight. (c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. No extra payment shall be admissible on that account. (d) Bolts, Nuts etc shall be measured and paid separately under respective items.
S&F Copper Bus Bar strip with insulation, of any size, for extention of MCCB terminals for cable terminations, inside the cable alley of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size complete all as specified and as directed . Note :- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs. (b) Overall length of the strip shall be measured and paid after necessary conversion into weight. (c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. No extra payment shall be admissible on that account. (d) Bolts, Nuts etc shall be measured and paid separately under respective items.
S&F of suitable type and size FRP / DMC bus bar support insulator (Bridge Insulator) for fixing the extended aluminium bars, for cable terminations, duly fixed in the body of the panel board by and including galvanized steel bolts , nuts, washers etc.and necessary drillings, in the panel body,complete all as specified and as directed.
M&L for repairing of Capacitor (APFC ) panel of 100KVAR to 250KVR and carryout repairs as (i)Dismantling of Power contactor,TP,415Volts and auxiulary contactors and cleaning,Overhauling,servicing ,repairing thorougly and replacing burnt contactors upto 63Amps including suitable capacity of copper wire single core,1100Volts grade -01 Job (New contactors will be measured paid separatly) (ii)Replacing of the HRC fuses and fuse base with MCB, D'curve,TP,415Volts upto 63Amps with mounting rail including suitable capacity of copper wire single core,1100Volts grade. (New HRC fuse /MCB will be measured paid separatly) (iii)Dismantling ,testing and replacing of damaged Capacitor banks up to 25KVAR including suitable capacity of copper wire single core,1100Volts grade (New Capacitor banks will be measured paid separatly) (iv) Reapair/repalcement of controle wiring of realy,contactors,aux contactors,indicating circuits,auto/manual circuits etc including all logic circuit with new copper wire single core1.5/2.5Sqmm,1100Volts grade-01Job
Supply only APFC Relay, 12Stages digital type suitable for 415V, 3phase, AC supply and all specified and directed. Make - L&T/ Syntron/Sycon
Supply and fix of power pack ,230V AC input, 30V DC /110Volt DC out put suitable for VCB/OCB 11 KV as power back complete Make : Alan/CG/Areva
Supply only Capacitor bank 5KVAr, Heavy duty type,415Volts,50Hz AC supply in existing panel complete as specified and directed by Engr-in-charge. (make: Prabodhan/Epcos/Havells/Schnieder
All all as per item No.126.00 but of rating 10KVAR
All all as per item No.126.00 but of rating 15KVAR
All all as per item No.126.00 but of rating 20KVAR
All all as per item No.126.00 but of rating 25KVAR
Supply only Power contactors Capacitor Duty(Type MOC of L&T) 50Amps Capacitor duty with 2NO+2NC suitable for ,415Volts,50Hz AC supply in existing panel completeas specified and directed by Engr-in-charge Make : L&T/C&S/Schnieder
All all as per item No.131.00 but rating 40Amps
All all as per item No.131.00 but rating 32Amps
S&F in repair of MCB,TP,C'Curve,63 Amps,415Volts,50Hz AC supply in existing panel with mounting rail complete as specified and directed by Engr-in-charge.
All all as per item No.134.00 but rating 40Amps
All all as per item No.134.00 but rating 32Amps
All all as per item No.134.00 but rating 20Amps
Supply only Auxilaury contactors 10Amps Capacitor duty with 8NO+8NC suitable for ,415Volts,50Hz AC supply in existing panel completeas specified and directed by Engr-in-charge Make : L&T/C&S/Schnieder/Havells
Supply only Time delay Timer suitable for APFC panel ,415Volts,50Hz AC supply in existing panel completeas specified and directed by Engr-in-charge Make : L&T/C&S/Schnieder/Havells
Supply only Current Transformers,415 Volt 600/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed. Make : AE/NSDA/MECO/C&S
Supply only Current Transformers,415 Volt 400/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed. Make : AE/NSDA/MECO/C&S
Supply only Current Transformers,415 Volt 200/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed. Make : CMake : AE/NSDA/MECO/C&S
Material and labour for fault finding on HT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
Supply and fix cable jointing STRAIGHT THROUGH JOINT for 11KV grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3 core XLPE armoured, alluminum conductor cable of size 120 to 185 sq mm and all as directed by Engineer-In-Charge.
Supply and fix cable jointing END TERMINATION JOINT for indoor/outdoor 11KV grade cable for End termination joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3 core XLPE armoured, alluminum conductor cable of size 90 to 185 sq mm and all as directed by Engineer-In-Charge. Make: 3M/Danson/raychem
Supply and fix cable jointing END TERMINATION JOINT for indoor/outdoor 11KV grade cable for End termination joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3 core XLPE armoured, alluminum conductor cable of size 240 to 300 sq mm and all as directed by Engineer-In-Charge. Make: 3M/Danson/raychem
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)11000 Volts grade with stranded aluminium conductor of size 185 Sqmm 3 core and all as directed by Engineer-In-Charge.
Material and labour for fault finding on LT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
Supply and fix cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 70 to 185 sq mm and all as directed by Engineer-In-Charge.
Supply and fix cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 240 to 300 sq mm and all as directed by Engineer-In-Charge.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 240Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 70Sqmm 3.5 core and all as directed by Engineer-In-Charge.
Material & labour for chequered plate 5 mm thick size as per site requirement including cutting to required shape and appling two coat of synthetic enamel paint over a coat of red oxide primer and all as directed
Material and labour for fixing angle Iron of size 25x25x6mm size and square bar applying two coats of synthetic enamel paint over a coat of red oxide primer and all as directed
Material and labour for PCC 1:2:4 type B-1 using (using 20mm graded stone aggregate) as in copings for pole including necessary form work etc complete all as specified and directed by Engineer-in-Charge
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth in hard/dense soil for laying of cable/ GI pipe and getting out complete all as specified and directed.
Returning, filling in including spreading levelling watering well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing surplus soil to a distance outside MoD land and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour for dry clean river sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed. Note :- Only compacted thickness of sand will be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV Type I, flat, size 250 mm x 150 mm x 40 mm. laid in trenches complete all as specified and directed.
Supply and fix insulation rubber mat at power houses and pump houses including pasting of rubber mats with adhesive resin all as specified and directed by Engineer-in-Charge.
Cutting metal road/hard standing for laying of cable and re metaling/making good the same to match the existing surface complete all as directed by Engr incharge.
M&L for repair/replacement of unserviceable parts of DG set of capacity 100 KVA installed at INS Shikra carrying out the following maintenance including testing on completion for satisfactory performance for a period of 02 hrs. at connected load complete all as specified and as directed :- (Make: Greaves Ltd & Kirolskar Green)
(a) Drain out of diesel from tank and storing in cleaned containers, cleaning the tank thoroughly by removing sediments settled at the bottom and refilling the drained out diesel duly filtered. (b) Drain out engine oil from the sump, cleaning the sump thoroughly and refilling the sump with new engine oil upto required level ( Note: Engine Oil will be measured and paid separately as 'Supply Only'). Replacement of Piston Assembly Replacement of Cylinder Liner Assembly- 06 Nos Replacement of Cylinder Liner Assembly- 06 Nos Replacement of Valve Pair Inlet and Exhaust- 06 Nos Replacement of Valve Seat Insert Inlet- 06 Nos Replacement of Valve Seat Insert Exhaaust- 06 Nos Replacement of Valve Guide- 12 Nos Replacement of Wire Snap Ring- 12 Nos Replacement of Con Rod Bearing- 01 Nos
Replacement of Piston Ring Set- 06 Nos Replacement of Oil Filter- 02 Nos Replacement of Diesel Filter (Pre))- 01 Nos Replacement of Diesel Filter (Micro)- 01 Nos (a) 4 hole Injector Nozzle TBD 234 H RPM- 06 Nos (b) Nozzle tenster and O ring- 01 Nos (c) Nozzle holder with nozzle- 01 Nos
Servicing of diesel engine of 100 KVA to 125 KVA repair/replacement of the following components including opening engine components checking and cleaning as required and replacing patrs all as specified and directed by Engr-in -charge (a) All fuel,oil,and coolent to be changed. (b) Element air cleaner 1 No (c) Checking and correcting up impeller of water pump for excess play. (d) Checking and correcting turbocharger oil leakage, tightening of mounting screws and nuts (e) Cleaning, tightening all electrical connection of engine (f) Cleaning of entire engine. (g) Checking exhaust and inlet manifold bolts and cap screw (h) Cleaning of radiator inside and outside by removing and refixing after cleaning. (j) Checking and adjusting injector and valves. (k) Checking of vibration damper. (l) Checking of fan belt and replace as required.
Servicing of diesel engine of 63 KVA repair/replacement of the following components including opening engine components checking and cleaning as required and replacing patrs all as specified and directed by Engr-in -charge (a) All fuel,oil,and coolent to be changed. (b) Element air cleaner 1 No (c) Checking and correcting up impeller of water pump for excess play. (d) Checking and correcting turbocharger oil leakage, tightening of mounting screws and nuts (e) Cleaning, tightening all electrical connection of engine (f) Cleaning of entire engine. (g) Checking exhaust and inlet manifold bolts and cap screw (h) Cleaning of radiator inside and outside by removing and refixing after cleaning. (j) Checking and adjusting injector and valves. (k) Checking of vibration damper. (l) Checking of fan belt and replace as required.
Taking down old MCX 33, 4 pole contactor from DG Set panel and supply and fixing its orginal position and testing as ditrcted by Engr- In- charge. Make : L & T or equivalent
Taking down old MCX 34, 4 pole contractfor from DG Set panel and supply and fixing its orginal position and testing as ditrcted by Engr- In- charge. Make : L & T or equivalent
Supply and fixing 12 Volt 180 AH battery with 24 plates , liquied immersed and fully charged Make- -Exide/Amron or equivalent
Repair to AMF pannel of scilient proof DG set 100 KVA and replacement the folowing items :
(a) MCCB 250 Amps 35 KA - 01 Nos (b) Fuse as per sample - 01 Nos (c) Card as per sample- 01 Nos (d) Relay as sample - 02 Nos (e) Timmer - 02 Nos (f) Display -01 (g) complete wiring and fuse and sencer unit etc.
Supply and replacement of AVAR for 100- 125 KVA DG set as per sample all as directed by Engr -in-Charger.
Supply only of engine oil of suitable grade for various DG Sets as per manufacturer's recommendation complete all as specified and as directed. Make: K-oil or Cummins.
Supply only of coolant suitable for DG sets complete all as specified and as directed. Make: K-oil / Cummins Castrol /Servo.
Taking out old U/S MCCBs and supplying and fixing of MCCB,3Pole,250 Amps,25kA, 415Volts,50Hz ACs including necessary cutting/fixing/fittings as per site requirement complete as specified and directed by Engr-in-charge. Make: Havells/Legrand/Siemens/Indoasion.
Taking out old U/S MCCBs and supplying and fixing of MCCB,3Pole,200 Amps,25kA, 415Volts,50Hz AC s including necessary cutting/fixing/fittings as per site requirement complete as specified and directed by Engr-in-charge. Make: Havells/Legrand/Siemens/Indoasion.
Taking out old U/S MCCBs and supplying and fixing of MCCB,3Pole,160 Amps,25kA, 415Volts,50Hz AC s including necessary cutting/fixing/fittings as per site requirement complete as specified and directed by Engr-in-charge. Make: Havells/Legrand/Siemens/Indoasion.
Taking out old U/S MCCBs and supplying and fixing of MCCB,3Pole,125 Amps,25kA, 415Volts,50Hz AC s including necessary cutting/fixing/fittings as per site requirement complete as specified and directed by Engr-in-charge. Make: Havells/Legrand/Siemens/Indoasion.
Taking out old U/S MCCBs and supplying and fixing of MCCB,3Pole,100 Amps,10kA, 415Volts,50Hz AC s including necessary cutting/fixing/fittings as per site requirement complete as specified and directed by Engr-in-charge. Make: Havells/Legrand/Siemens/Indoasion.
Taking out old U/S MCCBs and supplying and fixing of MCCB,3Pole, 63 Amps,10kA, 415Volts,50Hz AC s including necessary cutting/fixing/fittings as per site requirement complete as specified and directed by Engr-in-charge. Make: Havells/Legrand/Siemens/Indoasion.
Supply and Fixing Micro processor base fault relay protection for over current + L-L fault, SC fault, L-L-L fault Make: Seimens/Areva/Schneider/ABB
Taking out old U/S MCCBs and supplying and fixing of MCCB,4Pole, 400 Amps,35kA, 415Volts,50Hz AC s including necessary cutting/fixing/fittings as per site requirement complete as specified and directed by Engr-in-charge. Make: Havells/Legrand/Siemens/Indoasion.
Notes for Item Nos 1.00, 16.00 & 17.00 :- The rate quoted shall be deemed to be included the following :- (i) The shift time shall be first shift 0600hrs to 1400hrs, second shift 1400hrs to 2200hrs & third shift 2200hrs to 0600hrs as given in BOQ item. (ii) The contractor has to apply for entry pass, for the labours to be employed against the work, from Naval Police with valid documents and shall submit Police verification of labours after receipt of work order through GE (iii) Operator must be skilled & must have knowledge of operation & maintenance of AC Plant, RO Plant, Panel and controlling valves etc. (iv) Valve Man must be semi skilled & must have knowledge of controlling valves etc. (v) Consumable stores such as cotton waste, Grease including tools required shall be provided by the contractor. (vi) Operator must ensure cleanliness of AC Plant, RO Plant. (vii) The rate quoted by the contractor shall be inclusive of Life insurance for the tradesmen employed by him in case of untoward incident such as injuries, fracture or casualty while on duty. (viii) Carrying out minor repairs viz. replacing blown out fuses, recharging MCCBs, priming of pumps, repair to pipe lines as directed. (ix) Checking of leakage /water level in the radiator,checking of leakage of oil from the engine ,compressor etc, shall be carried out by the operator. (x) Inform the JE/AGE E&M in charge of any electric faults, water supply failure, and any other mishappenings. (xi) Any other work, not specifically mentioned above, but ordered by the Engineer-in-Charge for the smooth functioning of AC Plant and RO Plant will have to be carried out without any extra cost. Rates quoted shall be deemed to be included accordingly
(xii) Rate quoted shall be inclusive for Relief Staff to the persons employed in shifts. (xii) After issue of work order, contractor has to submit the list of employees including reserve alongwith relevant documents as directed by Engineer-in-Charge. (xiv) Payment to employees shall be done by crossed cheque through Aadhaar linked bank account only and it shall not be less than minimum fair wages as per act in vogue. The contractor shall submit proof to Engineer-in-Charge before claiming any payment. (xiv) Contractor has to submit proof of payment of EPF subscription made by him alongwith RAR failing which RAR will not be progressed for payment. (xv) The rates quoted by the contractor shall be deemed to be included provision of all latest labour laws / regulations including all relevant taxes as applicable. (xvi) Contractor shall quote the rates considering their monthly leaves, releiver etc as per labour laws and nothing extra shall be paid on account of the above. In case of absence of staff/tradesman from duty, payment of that shift will not be paid. In addition to that a penalty of Rs 700/- per shift per person will be recovered from contractors dues. Also in case of long absence (more than one week) of staff/tradesman, the penalty shall be recovered including Sundays & Holidays if any. The contractor shall have no claim on this account.
(xvii) Contractor has to supply three sets of Tools and Plants to the labours employed by him and should be placed with the safe custody of department. Rates quoted shall be deemed to be included the above provision. (xviii) In case any variation in manpower as indicated in Column No 4 of BOQ due to any reasons / or any manpower held in Department or any policy change contractor should have no claim on that account. The bidders are advised not to quote rate less than minimum fair wages as circulated by competent authority. If the quoted amount is less than the estimated cost of work mentioned in NIT, the lowest bidder will have to deposit FDR/BGB as elaborated herein after in favour of Accepting Officer within 07 days of opening of financial bid (Cover No 2). The deposited amount shall be the difference between estimated cost mentioned in NIT / TS for M & O items and amount quoted by lowest bidder against M&O items. FDR/BGB shall be released only after satisfactory completion of work. If the contractor fails to pay minimum wages to employees, the department shall have right to withhold the said amount which will be verified by GE. The decision of Accepting Officer regarding amount to be withhold shall be final and binding. The withhold amount will be utilised by GE for payment to employees if contractor fails to pay minimum wages and balance amount if any shall only be released. If the lowest bidder fails to deposit the amount as stated above within 07 days, the contractor shall be banned for 06 months & his bid shall be rejected. The contractor shall sumbit 03 Nos of FDRs of equal amount as mentioned above. The FDRs validity shall be 04 months, 08 month & 12 months respectively for the purpose of encashment/ release as the case may be
cooltech engineering services
GRAND SERVICES
shakti engineering and electrical works
somnath engineering corporation
BRITE INDUSTRIES
pk Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .