| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC 1ST FLOOR BL 8 6 DR B C ROY SARANI JYANGRA BAGUIHATI KOLKATA 700059 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | ₹17.9 L | L1 | Accepted-AOC 1st lowest |
| 2 | L2₹18.5 LRejected-Finance AT DANGALPARA SURJ BIRBHUM PIN 731191 | SURI | BIRBHUM | WEST BENGAL | 731191 | ₹18.5 L | L2 | Rejected-Finance 2nd lowest |
| 3 | L3₹18.7 LRejected-Finance MAIRAKATA P O GARBETA DIST PASCHIM MEDINIPUR 721127 | GARBETA | PASCHIM MEDINIPUR | WEST BENGAL | 721127 | ₹18.7 L | L3 | Rejected-Finance 3rd lowest |
| Sl No | Description | Qty | Unit | M/S S. CHATTERJEE L1 | BABA ELECTRIC L2 | R.K.ENTERPRISE L3 |
|---|---|---|---|---|---|---|
| 1.00 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- R R Kabel/ Havells/KEI/Polycab/as per direction of EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/ fan/call bell points with Modular type switch (Make- Legrand/Havells/L&T/Gold Medal/ as per direction of EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 8 mtr | 320 | Pt | 1,344 ₹4.3 L | 1,350 ₹4.3 L | 1,351 ₹4.3 L |
| 1.01 | On Board | 64 | Pt | 271 ₹17,344 | 280 ₹17,920 | 281 ₹17,984 |
| 2.00 | Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works 19 mm dia 3 mm thick polythene pipe without earth continuity wire | 840 | Mtr | 108 ₹90,720 | 110 ₹92,400 | 111 ₹93,240 |
| 3.00 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make- R R Kabel/ Havells/KEI/Polycab/as per direction of EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 1.5 sqmm | 440 | Mtr | 60 ₹26,400 | 60 ₹26,400 | 61 ₹26,840 |
| 3.01 | 2x2.5 sqmm+1x1.5 sqmm | 100 | Mtr | 81 ₹8,100 | 80 ₹8,000 | 82 ₹8,200 |
| 3.02 | 2x 6 sqmm + 1x 4 sqmm | 300 | Mtr | 174 ₹52,200 | 175 ₹52,500 | 178 ₹53,400 |
| 4.00 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works 175 x 100 x 65 | 20 | Nos. | 197 ₹3,940 | 198 ₹3,960 | 200 ₹4,000 |
| 4.01 | 200 x 150 x 65 | 24 | Nos. | 266 ₹6,384 | 265 ₹6,360 | 270 ₹6,480 |
| 5.00 | Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required 175 x 100 x 65 | 20 | Nos. | 58 ₹1,160 | 56 ₹1,120 | 55 ₹1,100 |
| 5.01 | 200 x 150 x 65 | 24 | Nos. | 75 ₹1,800 | 1,850 ₹44,400 | 1,840 ₹44,160 |
Tender Value
Refer Docs
EMD Value
₹30,010
Closing Date
23 Feb 2024, 10:55 amClosed
Executive Engineer, PWDte
Bankura
Thorough Renovation of Internal Electrical Installation work of the Boys Hostel building at Ramananda College Bishnupur in the district of Bankura.
2024_WBPWD_664106_1
WBPWDTE/EE/BED/NIQ_78/Q of 2023-24
Open Tender
ELECTRICAL WORKS ORG
45 days
Bishnupur
Please refer Tender documents.
3 documents required · 3 mandatory
₹30,010
15 May 2026
9 Feb 2024
27 Feb 2024
9 Feb 2024
23 Feb 2024
9 Feb 2024
Amount
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- R R Kabel/ Havells/KEI/Polycab/as per direction of EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/ fan/call bell points with Modular type switch (Make- Legrand/Havells/L&T/Gold Medal/ as per direction of EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 8 mtr
On Board
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works 19 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make- R R Kabel/ Havells/KEI/Polycab/as per direction of EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 1.5 sqmm
2x2.5 sqmm+1x1.5 sqmm
2x 6 sqmm + 1x 4 sqmm
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works 175 x 100 x 65
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required 175 x 100 x 65
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. (Make- Legrand/L&T/ABB/Havells/as per direction of EIC) 2+10 Way
Supplying and fixing MCB SS enclosure with IP-20 /30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment as per GS. (Make- Legrand/L&T/ABB/Havells/as per direction of EIC) 2 Way
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS. (Make- Legrand/L&T/ABB/Havells/as per direction of EIC) 6Way
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS (Make- Legrand/L&T/ABB/Havells/as per direction of EIC) 4Way ( Up to 160 A )
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS (Make- Legrand/L&T/ABB/Havells/as per direction of EIC) 40 A DP
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS (Make- Legrand/L&T/ABB/Havells/as per direction of EIC). 160 A FP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS (Make- Legrand/L&T/ABB/Havells/as per direction of EIC) 6-32 SP
32A DP MCB For Street Light Control
63A TPMCB
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall as per GS. [Make- Siemens/L&T/ ABB/ Havells/ as per direction of EIC]. 160A
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make- R R Kabel/ Havells/ Gloster/ as per direction of EIC] 2 Core 10 Sq. mm
4Core 25 Sq. mm
4Core 70 Sq. mm
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes. 2.5 to 35 Sq. mm
Laying of cable above 35 and upto 185sqmm in underground trench as per GS.
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. (Brand approved by EIC) 2 Core 10 Sq. mm
4Core 25 Sq. mm
4Core 70 Sq. mm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS (Brand approved by EIC) 40 mm dia
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket with 6A Modular type switch as per GS (Make- Legrand/Havells/L&T/Gold Medal/ as per direction of EIC)
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket with 16A Modular type switch, without plug to as per GS (Make- Legrand/Havells/L&T/Gold Medal/ as per direction of EIC)
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch, 16A Modular switch type MCB as per GS (Make- Legrand/Havells/L&T/Gold Medal/ as per direction of EIC)
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS.
Fixing only single/twin fluorescent light fitting in the ceiling fixed with “L” type MS clamp as per GS
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit as per GS
Supply & Fixing angular batten holder (Brand approved by EIC) on 75mm dia PVC round block / round bakelite on wall/ceiling as per GS
Supply of LED 4 Ft. 20 Watt single/twin florescent light fitting for indoor application,complete with all accessories & 18 Watt LED Master Tube [ Make -Philips Model No- TMC 502 1xT-LED 22W with 18 master tube Mas LED Tube 1200mm 18W865 T8 I/ equivalent model of CG/Wipro/ Jaquar/as per direction of EIC)
TMC 502 2xT-LED 22W with 2 nos 18 master tube Mas LED Tube 1200mm 18W865 T8 I
S&F 9 watt LED Light (Make- Philips/CG/ Wipro/ Jaquar/ as per direction of EIC)
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Make- Legrand/Havells/L&T/Gold Medal/ as per direction of EIC) on existing Modular GI switch board as per GS
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS
Fixing only exhaust fan after making holes in wall as per GS (12")
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall as per GS (12")
Supply of ceiling fans complete with all accessories having the following Model / Cat No.( Make -Usha Striker plus safety wire with P2 capacitor/euivalent model of Crompton Greaves/ Orient/ as per direction of EIC) 1200 mm Sweep
Supply of heavy duty Exhaust fans complete with all accessories having the following Model / Cat No. 12"( 300mm ) Speed 1420 RPM (Make- EPC/CG/Usha/ as per direction of EIC)
S & Erection of mini pole (Brand approved by EIC) of size 6 ft. long approx 80 mm. dia seamless pipe Class - B , on the roof of the Bldg. By S& providing M.S. plate incl. Rose type arrangement near base plate for smooth cable entry position and making C.C. muffing of size 450 x 450 x 600 mm. hight with cement mortor mixture ( 6 : 3 : 1 ) incl. neet cement finish before cheaping properly the existing roof incl. S& providing earth bold after drilling holl etc. as per direction of E.I.C.
S&F cylindrical type pole head suitable for 80 mm. dia seamless pipe and should be waterproof & fabricated from steel member steel pipe. The cylindrical portion of the pole head which sleeve over the pole shall have a length of 40 cm. ( 18" ) approx. Incl. making 225 mm. dia ( 9" ) cable terminal box. The above terminal box welded with sleeve incl. S&F 1 No. 4 way bakelite terminal AC/DC make & 1 No. 15 Amp. fuse base & bridge inside the cylindrical portion of the header assembly as per direction of E.I.C.
S&F 50 mm. dia 1.5 mtr. long detachable type Single arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC
Inter connection of LED light fittings by 2 x 1.5 Sq. mm. PVC insulated copper wire (Make- R R Kabel/ Havells/KEI/Polycab/as per direction of EIC) from pole loop box with best quality PVC pipes as per direction of EIC
Supply & Fixing of 240V, 90 Watt Fittings Crompton [ Cat No. LSTN-90 -CDL -A]
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint Upto 9.0 mtr. long pole 1st coat of aluminium paint over 1 coat of RO priming and 2nd coat of aluminium paint over 1st coat as per GS
Excavation of soil for installation of Earth Electrode and filling & ramming as per GS For Morum Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS 4SWG
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS
BABA ELECTRIC
R.K.ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.22 MB
BOQ_1439545.xls
BOQ • 0.35 MB
2911.pdf
Additional Documents • 0.13 MB
Download all tender documents and submit your bid