| Sl No | Description | Qty | Unit | SUN LIGHT HOUSE L2 | Haasith constructions L1 | Srinivasa Consructions L6 | sandhya enterprises L5 | sree venkateswara enterprises L3 | Srinivash Engineers L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00Dismantling and strip opening the centrifugal/ Monoblock pump including disconnecting the suction, delivery, vaccum pipe lines and coupling for repairs to pump and refixing the same after repairs including overhauling the pump set, renewal of gasket to pump suction and delivery lines, gland packing, greasing nuts, bolts and washers, Metal Sleeves, painting, all kind of grinding & welding work, replacement of bearing, etc as required for arresting any kind of water leakages including testing and commissioning complete all as specified and directed for the following capacities as mentioned below : | |||||||||
| 1.01 | Pump 3 phase 220 to 240 HP capacity. | 3 | JOB | 15,000 ₹45,000 | 12,000 ₹36,000 Lowest | 20,000 ₹60,000 | 16,400 ₹49,200 | 15,000 ₹45,000 | 15,000 ₹45,000 |
| 1.02 | Pump 3 phase 180 to 200 HP capacity. | 3 | JOB | 12,000 ₹36,000 | 9,000 ₹27,000 Lowest | 20,000 ₹60,000 | 12,300 ₹36,900 | 13,000 ₹39,000 | 10,000 ₹30,000 |
| 1.03 | Pump 3 phase 7.5 HP capacity. | 3 | JOB | 3,000 ₹9,000 | 2,400 ₹7,200 | 300 ₹900 Lowest | 3,280 ₹9,840 | 700 ₹2,100 | 2,900 ₹8,700 |
| 1.04 | Pump 3 phase 3 to 5 HP capacity. | 1 | JOB | 2,500 ₹2,500 | 1,800 ₹1,800 | 2,000 ₹2,000 | 2,460 ₹2,460 | 600 ₹600 Lowest | 2,500 ₹2,500 |
| 1.05Notes for item Nos 1.01 to 1.04 :- (i) The rate quoted is deemed to be inclusive of tools and plants including transportation of pump set from site to workshop and back required for carrying out the repairs. (ii) The rate quoted is deemed to be inclusive of cost towards miscellaneous items such as cotton waste, grease, Gland packing, nut bolts, all kind of grinding, welding work, gasket and other minor consumables. The cost of other spares for pump measured and paid separately under appropriate items. (iii) The rate quoted is deemed to be inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The cost of spares for pump not mentioned above will be considered separately under appropriate items. | |||||||||
| 2.00Dismantling and strip opening the centrifugal/ INDUCTION motor including disconnecting the cable connections and coupling of the motor, removing the starter and rotor units, bearings, servicing the motor assembly including cleaning the carbon deposits with carbon tetra chloride, greasing the bearings etc, heat varnishing the motor windings by applying varnish and keeping the windings into the hot air oven till the moisture evaporates completely at authorized workshop and refixing the same after repairs including connecting up of the electric connections including testing and commissioning complete all as specified for the following capacities :- | |||||||||
| 2.01 | Motor 3 Phase 220 to 240HP capacity. | 5 | JOB | 10,000 ₹50,000 | 9,000 ₹45,000 Lowest | 20,000 ₹1,00,000 | 12,300 ₹61,500 | 9,000 ₹45,000 Lowest | 12,000 ₹60,000 |
| 2.02 | Motor 3 Phase 180 to 200 HP capacity. | 3 | JOB | 7,000 ₹21,000 | 6,000 ₹18,000 Lowest | 20,000 ₹60,000 | 8,200 ₹24,600 | 8,000 ₹24,000 | 10,000 ₹30,000 |
| 2.03 | Motor 3 Phase 7.5 HP capacity. | 4 | JOB | 2,500 ₹10,000 | 1,800 ₹7,200 | 3,000 ₹12,000 | 2,460 ₹9,840 | 900 ₹3,600 Lowest | 2,500 ₹10,000 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
25 Jul 2025, 6:00 pmClosed
GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIR/ REPLACEMENT OF PUMP CONTROL PANEL, PUMP, MOTORS, EARTHINGS, BOREWELL PUMP MOTOR, COPPER CABLE, AVIATION LIGHTING, PROTECTION, WATER LEVEL INDICATORS AND ALLIED WORKS AT DIV UNIT AREA, 54 IDSR, 554 ASC, 654 EME BN, ASSAY LINE, MAP JCO/ OR ACCN
2025_MES_717336_1
GE (U)/SEC/TOKEN/15 OF 2025-26
Open Tender
Civil Works - Water Works
Item Rate
270 days
SECUNDERABAD
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹70,000
Yes
6 Oct 2025
28 Jun 2025
1 Aug 2025
28 Jun 2025
25 Jul 2025
11 Jul 2025
Amount
Dismantling and strip opening the centrifugal/ Monoblock pump including disconnecting the suction, delivery, vaccum pipe lines and coupling for repairs to pump and refixing the same after repairs including overhauling the pump set, renewal of gasket to pump suction and delivery lines, gland packing, greasing nuts, bolts and washers, Metal Sleeves, painting, all kind of grinding & welding work, replacement of bearing, etc as required for arresting any kind of water leakages including testing and commissioning complete all as specified and directed for the following capacities as mentioned below :
Pump 3 phase 220 to 240 HP capacity.
Pump 3 phase 180 to 200 HP capacity.
Pump 3 phase 7.5 HP capacity.
Pump 3 phase 3 to 5 HP capacity.
Notes for item Nos 1.01 to 1.04 :- (i) The rate quoted is deemed to be inclusive of tools and plants including transportation of pump set from site to workshop and back required for carrying out the repairs. (ii) The rate quoted is deemed to be inclusive of cost towards miscellaneous items such as cotton waste, grease, Gland packing, nut bolts, all kind of grinding, welding work, gasket and other minor consumables. The cost of other spares for pump measured and paid separately under appropriate items. (iii) The rate quoted is deemed to be inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The cost of spares for pump not mentioned above will be considered separately under appropriate items.
Dismantling and strip opening the centrifugal/ INDUCTION motor including disconnecting the cable connections and coupling of the motor, removing the starter and rotor units, bearings, servicing the motor assembly including cleaning the carbon deposits with carbon tetra chloride, greasing the bearings etc, heat varnishing the motor windings by applying varnish and keeping the windings into the hot air oven till the moisture evaporates completely at authorized workshop and refixing the same after repairs including connecting up of the electric connections including testing and commissioning complete all as specified for the following capacities :-
Motor 3 Phase 220 to 240HP capacity.
Motor 3 Phase 180 to 200 HP capacity.
Motor 3 Phase 7.5 HP capacity.
Motor 3 Phase 3 to 5 HP capacity.
Notes for item Nos 2.01 to 2.04:- (i) The rate quoted is deemed to be inclusive of tools and plants including transportation of motor from site to workshop and back required for carrying out the repairs. (ii) The rate quoted is deemed to be inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii) The rate quoted is deemed to be inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The cost of spares for motor shall be paid separately under appropriate items.
M&L in replacement for rewinding the centrifugal/ Monoblock electric motor starter or rotor with PVC insulated, super enamelled copper conductor with ‘F’ class heavy grade insulation weight and turns to achieve its full efficiency including tying the winding and connecting the coils and brining the connections as that of existing one including applying insulating varnish, heating and backing the windings thoroughly including taking down old existing copper winding complete all as specified and directed of following capacities :- NOTE : Quoted rates inclusive of dismantling, refixing and transportation
Stator winding of Electric motor, 3 phase,220 to 240 HP capacity.
Stator winding of Electric motor, 3 phase,180 to 200 HP capacity.
Stator winding of Electric motor, 3 phase,7.5 HP capacity.
Stator winding of Electric motor, 3 phase, 3 to 5 HP capacity.
S&F in replacement of the following spares suitable for make existing at site of pump 2 stage 70 LPS capacity for repairs complete all as specified and directed :-
Pump shaft suitable for 2 stage impeller of capacity 70 LPS.
Cast Iron impeller Ist stage suitable for 70 LPS pump
Cast Iron impeller IInd stage suitable for 70 LPS pump.
Cast Iron bearing cover for drive and non drive end for pump of capacity 70 LPS
Cast iron inter stage ring for pump of capacity 70 LPS.
Rubber for water reflector for pump
Cast Iron shaft sleeve for drive end for pump of capacity 70 LPS.
Cast Iron shaft sleeve for non drive end for pump of capacity 70 LPS..
Cast Iron spacer sleeve for drive end for pump of capacity 70 LPS.
Supply only the spare part of Drive End Bearing suitable for make of motor existing at site for repairs of the following capacities of motors complete all as specified and directed :-
Cast Iron spacer sleeve for non drive end for pump of capacity 70 LPS..
Lock nut round type for pump of capacity 70 LPS.
Bronze nut for shaft sleeve for pump
Stuffing box bush cast Iron for pump
Gland packing for pump of capacity 70 LPS.
Set of key for pump set
Set of ‘O’ ring for pumps
Set of gaskets 3.0mm thick as per sample set of ‘O’ ring for pumps.
Cast iron gland set of 2 halves for pump of capacity 70 LPS Make of Pumps & Motors :- KIRLOSKAR/BEACON WEIR/DECON AIRCON/CG
Supply and fix in replacement the spare part of Non Drive End Bearing suitable for make of motor existing at site as in repairs for the following capacities of motors complete all as specified and directed :-
Motor, 3 phase, capacity 220 to 240 HP.
Motor, 3 phase, capacity 180 HP to 200 HP.
Motor, 3 phase, capacity 7.5 HP.
Motor, 3 phase, capacity 3 HP to 5 HP.
Motor, 3 phase, capacity 220 to 240 HP.
Motor, 3 phase, capacity 180 HP to 200 HP.
Motor, 3 phase, capacity 7.5 HP.
Motor, 3 phase, capacity 3 HP to 5 HP.
S&F in replacement of the ball bearing/ roller bearing (For Non-Drive End) suitable for make of pump existing at site for repairs of the following capacities of pumps complete all as specified and directed :-
Pump, fitted with 3 phase motor of capacity 220 to 240 HP.
Pump fitted with 3 phase motor of capacity 180 to 200 HP.
Pump fitted with 3 phase motor of capacity 7.5 HP.
Pump fitted with 3 phase motor of capacity 3 to 5 HP.
S&F in replacement of the ball bearing/ roller bearing (For Drive End) suitable for make of pump existing at site for repairs of the following capacities of pumps complete all as specified and directed :-
Pump, fitted with 3 phase motor of capacity 220 to 240 HP.
Pump fitted with 3 phase motor of capacity 180 to 200 HP.
Pump fitted with 3 phase motor of capacity 7.5 HP.
Pump fitted with 3 phase motor of capacity 3 to 5 HP.
Supply and fix in replacement thermal overload relay with built in single phase prevention (CT Operated), 3 phase of capacity 180-300 Amps suitable for 3 phase star delta starter, type MN12, 440 volts with necessary fixing materials including disconnecting and removing the old existing one complete all as specified and directed. Make :- L&T Cat No : SS94139OOQO or equivalent make in Siemens /Legrand
Supply and fix in replacement of electronic timer switch ST 100, 240/360/415 volts, Range 3 to 30 sec with mounting kit suitable for old existing ET 100replacement complete all as specified and directed. Make :- L&T Cat No : ST80328OOOO or equivalent make in Siemens /Legrand
S&F in replacement power contactor with coil voltage of 440 volts, 50 cycle confirming to IS, 300 Amps, 3 pole, type ML 12 with necessary inter connections suitable for 200 to 220 HP electric motor, testing and commissioning including removing the old existing one complete all as specified and directed. Make : L&T cat No : CS91010 or equivalent make in Siemens /Legrand
S&F in replacement for spare contact kit of voltage of 440 volts, 50 cycle conforming to IS, 300 Amps, 3 pole, type ML 12 with kit necessary inter connections suitable for 200 to 240 HP electric motor, testing and commissioning including removing the old existing one complete all as specified and directed. Make : L&T Cat No SS95317 or equivalent make in Siemens /Legrand
All as per item no 12.00 but 200 amps ML-10 suitable for 150 HP to 180 HP electric motor Make L&T Cat No SS 935315 or equivalent make in Siemens Legrand
S&F in replacement for spare coil for power contactor voltage of 440 volts, 50 cycle conforming to IS, 200 to 300 Amps, 3 pole, type ML 10 / 12 with kit necessary inter connections suitable for 150 to 200 to HP electric motor, testing and commissioning including removing the old existing one complete all as specified and directed. Make : L&T Cat No SS91011 or equivalent make in Siemens /Legrand
Supply and fix in replacement of Copper cable lugs of size of following sizes complete all as specified and directed :-
Supply and replace coupling including rubber / belt of 150 HP to 240 Hp motor including necessary arrangements complete all as specified and directed. Note : Quoted rates inclusive all arrangements required for replacement of Coupling
Material and labour in replacement for detachable Coupling cover for safety of operator of 150 HP to 220 HP motor made out of 2 MM thick CRCA sheet duly painted on length 1.1 m and width 30 CM including necessary arrangement for fixing at Base frame by using Nut and Bolts . Note : Quoted rates inclusive all arrangements required for fixing the protection cover
Supply and replace Unserviceable pressure gauge stainless steel of pressure range 100 PSI Suitable for 70 LPS Pumps complete including necessary arrangements including supporting pipes complete all as directed Note : Quoted rates inclusive all arrangements required for replacement of Pressure Guage
Servicing / periodical checking of Starter panel board suitable for 150 HP to 220 HP Motor by replacing all unserviceable parts, checking for any kind of loose contact, identification of fault etc complete all as specified and directed . Note : All spare to be replaced and measured under relevant items.
Disconnecting and removing the water and electric connections carefully from the existing submersible pump sets of capacity 3 HP to 5 HP and taking out the pump set alongwith pipes and fittings for flushing the bore well up to 450 feet depth or repair the pump set and strip opening the pump set for repairs/ replacement of worn out spares, refixing of serviceable spares, assembling the pump set completely, testing of pump set, lowering the pump set inside the bore well after repairs including connecting back the water and electric connections, commissioning of pump set for satisfactory operation on its full load complete all as specified and directed. Note :- The spares required for repair the pump sets and rewinding of motors will be measured and paid separately.
Disconnecting and removing the water and electric connections carefully from the existing submersible pump sets of capacity above 5 HP to 10 HP and taking out the pump set alongwith pipes and fittings for flushing the bore well above 450 feet and up to 750 feet depth or repair the pump set and strip opening the pump set for repairs/replacement of worn out spares, refixing of serviceable spares, assembling the pump set completely, testing of pump set, lowering the pump set inside the bore well after repairs including connecting back the water and electric connections, commissioning of pump set for satisfactory operation on its full load complete all as specified and directed. Note :- The spares required for repair the pump sets and rewinding of motors will be measured and paid separately.
M&L for rewinding the Submersible pump Motor with PVC insulated, super enamelled copper conductor with ‘F’ class heavy grade insulation weight and turns to achieve its full efficiency including tying the winding and connecting the coils and brining the connections as that of existing one including applying insulating varnish, heating and backing the windings thoroughly including taking down old existing copper winding complete all as specified and directed for Submersible pump motor of following capacity :-
Submersible Motor above 3 HP up to and including 5 HP.
Submersible Motor above 5 HP up to 10 HP.
Supply and replacement of the following spares suitable for existing make of submersible pump set 3 to 10 HP capacity, multi stage for repairs complete all as specified and directed :-
Gun metal Impeller.
Stage casing.
SS Sleeves.
Middle bush.(LB)
Middle sleeve.
Discharge outlet.(LB)
Pump coupling.
DOL SS Sleeve.
Suction bush.
Pump Shaft
Complete removal of existing treatment including preparation of old painted surfaces by washing, rubbing down and stopping of painted surfaces, painting with one coat of synthetic enamel paint of approved colour on centrifugal pump set of 150 HP to 240 HP capacity including inlet, outlet mains, couplings, sluice valve, non return valve, base plate, pulley with safe guard, vacuum pipe line, LT panel board and writing the MES / SM number with black paint of suitable size of letters complete all as specified and directed.
S&F in replacement PVC insulated Copper conductor, sheathed, Submersible flat cables of size 4 Sqmm, 3 core, for Submersible Pumps, 1100 Volts grade, conforming to IS:694/1990 with latest amendments cutting to required length connecting with necessary end ferrules / water proof joints and jointing and testing including disconnecting/taking out old existing cable complete all as specified and directed.
S&F in replacement PVC insulated Copper conductor, sheathed, Submersible flat cables of size 2.5 Sqmm, 3 core, for Submersible Pumps, 1100 Volts grade, conforming to IS:694/1990 with latest amendments cutting to required length connecting with necessary end ferrules / water proof joints and jointing and testing including disconnecting/taking out old existing cable complete all as specified and directed.
Material and labour in replacement of Rubber mat of size 1mX2mX20mm ISI marked
Material labour for removing submersible pump motor set of capacity up to 7.5 HP stuck in side the borewell of depth up to 100 meter including by flushing the existing borewells of any size with drilling compressor mounted on truck at a pressure of 7 Kg / Sqcm with compressed air and flushing the sand, mud including flushing out tree roots etc from the bore well till discharge of the fresh water and then clear the bore by using Rod drilling using Bore well drilling machine from any kind of obstruction, reinstall the motor and column pipe, necessary electric connection and testing complete all as specified and directed . Note; rate quoted by the contractor inclusive of Flushing by using suitable compressor, rod drilling for clearing of bore well, Removing the submersible pump set stuck inside the bore well and reinstall the same after repair including removing and refixing of column pipe, electrical connections, testing etc as required .
Supply & fixing in replacement HDPE heavy duty column pipe in Bore well internal dia 50mm PN 16kq/Sqmm including all necessary fittings and fixtures as requited for fixing with submersible motor Complete all as specified and directed. Note: Quoted rate inclusive of fixing of pipe with submersible motor and lowering in existing bore well
Supply & fixing in replacement HDPE heavy duty column pipe in Bore well internal dia 65 mm PN 16kq/Sqmm including all necessary fittings and fixtures as requited for fixing with submersible motor Complete all as specified and directed. Note: Quoted rate inclusive of fixing of pipe with submersible motor and lowering in existing bore well
Supply and fixing in replacement of DOL Starter suitable for up to 7.5 HP Motor, 5.5 KW and relay max range 20-32 Amp as in repairs complete all as specified and as directed. Makes : L&T cat part No CS90947 or equivalent of Havells/CG as approved.
Supply and fixing in replacement of single phase preventer suitable for up to 7.5 HP motor as in repairs complete all as specified and as directed. Make : L&T cat part No CS94824DOOO or equivalent of Havells/MINILAC
Supply and fix in replacement BRASS non return (reflux) valve screwed end with gun metal seat type of size 50 mm all as specified and directed. Make: Kartar/Kirloskar/Durga/Zoloto
Supply and fix in replacement of mild steel section (Angle iron, channel, I beans etc) including fabrication work (as QTL, welding, cutting, drilling etc) and required base for pump & motors
Supply and fix in replacement Cast iron foot valve swing type flanged of size 50 mm as per IS 4038 all as specified and directed. Make Kartar/Kirloskar/Durga
Supply and fix in replacement Cast iron foot valve swing type flanged of size 65 mm as per IS 4038 all as specified and directed. Make Kartar/Kirloskar/Durga
Supply and fix in replacement Cast iron foot valve swing type flanged of size 80 mm as per IS 4038 all as specified and directed. Make Kartar/Kirloskar/Durga
Supply and fix in replacement Contactor 40 amps 3 phase coil operating voltage 230 volt all as specified and directed.
Supply and fix in replacement Contactor 25 amps 3 phase coil operating voltage 230 volt all as specified and directed.
Supply and fix in replacement MCB SP&N 32 Amps 10 KA C Curve all as specified and directed.
Supply and fix in replacement MCB SP&N 25 Amps 10 KA C Curve all as specified and directed.
Supply and fix in replacement MCB SP&N 20 Amps 10 KA C Curve all as specified and directed.
Supply and fix in replacement MCB TP&N 20 Amps 10 KA C Curve all as specified and directed.
Supply and fix in replacement MCB TP&N 32 Amps 10 KA C Curve all as specified and directed.
Disconnecting, dismantling and taking aside the Pump set of 10 to 25 HP capacity for replacement of existing base frame with new one from the installed position and dismantling of existing PCC / RCC foundation and refixing the same motor by preparing sufficient PCC foundation and base frame required for 10 to 25 HP pump including connecting items like nuts, bolts and setting the alignment of motor and pump set testing and commissioning all as specified and directed. Note: The quoted rate will be inclusive of required replacement of base frame/ MS channel and PCC / RCC for foundation.
Disconnecting, dismantling and taking aside the Pump set of 5 to 7.5 HP capacity for replacement of existing base frame with new one from the installed position and dismantling of existing PCC / RCC foundation and refixing the same motor by preparing sufficient PCC foundation and base frame required for 5 to 7.5 HP pump including connecting items like nuts, bolts and setting the alignment of motor and pump set testing and commissioning all as specified and directed. Note: The quoted rate will be inclusive of required replacement of base frame/ MS channel and PCC / RCC for foundation.
Disconnecting, dismantling and taking aside the centrifugal motor and Pump set of 150 to 240 HP capacity for replacement of existing base frame with new one from the installed position and dismantling of existing PCC / RCC foundation and refixing the same motor by preparing sufficient PCC foundation and iron base frame required for 150 hp to 220 HP pump and Motor including connecting items like nuts, bolts and setting the alignment of motor and pump set testing and commissioning all as specified and directed. Note: The quoted rate will be inclusive of required replacement of base frame/ MS channel and PCC / RCC for foundation.
Arresting leakages from pumps of motor capacity 05 HP to 25 HP by replacing gasket, nutbolts, gland packing etc as required complete all as directed Note: Rate quoted by the contractor inclusive of all items as require to arrest the leakages from pumps
Arresting leakages from pumps of motor capacity 150 HP to 240 HP by replacing gasket, nutbolts, gland packing etc as required complete all as directed Note: Rate quoted by the contractor inclusive of all items as require to arrest the leakages from pumps
M&L for flushing of existing borewells of any size up to 150 Mtrs depth with drilling compressor mounted on truck including surging and flushing the bore at a pressure of 7 Kg / Sqcm with compressed air and flushing the sand, mud including flushing out tree roots etc from the bore well till discharge of the fresh water including testing of water samples for chemical and bacteriological tests and complete all as specified and directed .
M&L for flushing of existing borewells of any size up to 250 Mtrs depth with drilling compressor mounted on truck including surging and flushing the bore at a pressure of 7 Kg / Sqcm with compressed air and flushing the sand, mud including flushing out tree roots etc from the bore well till discharge of the fresh water including testing of water samples for chemical and bacteriological tests and complete all as specified and directed .
M & L for shifting of centrifugal Monoblock Motor of capacity 5 HP to 10 HP to a new location as directed after disconnecting from existing position including making base by using PCC (1:2:4 by using 20 mm gravel of size not less than 1 M X0.75 X0.75 M and base by using C Channel of suitable size and making electric and water connection complete all as specified and directed. Note : Quoted rates inclusive all arrangements required for Shifting of Pump set
Servicing / periodical checking of Starter panel board suitable for 15 HP to 40 HP Motor by replacing all unserviceable parts, checking for any kind of loose contact, identification of fault etc complete all as specified and directed . Note : All spare to be replaced and measured under relevant items.
Servicing / periodical checking of Starter panel board suitable for 5 HP to 10 HP Motor by replacing all unserviceable parts, checking for any kind of loose contact, identification of fault etc complete all as specified and directed . Note : All spare to be replaced and measured under relevant items.
Servicing of Submersible pump motor set of capacity up to 10 HP complete all as directed
Supply and fixing in replacement only the following spares for repairs of centrifugal / Monoblock pump set of up to 10 HP capacity complete all as specified and directed :-
Ball bearing suitable for induction motor.
Ball bearing for non drive end suitable for pump.
GM bush.
CI impeller.
MS pump shaft.
Gland cover.
Supply and fixing in replacement of the following spares for repairs of Centrifugal pump set of above 10 to 40 HP capacity complete all as specified and directed :-
(a) Ball bearing drive end for suitable size.
(b) Ball bearing for non driving end of suitable size.
(c) Gun Metal bush.
(d) CI impeller.
(e) MS pump shaft.
(f) Gland cover.
(g) Gland.
Supply and fix in replacement of unserviceable Gun metal (Bronze) Gate, globe & check valves IS : 778/1980 CL-1, K604 type connected with iron wheel head, screwed at both ends for iron pipes and fixed complete all as specified and directed for the following sizes:-
(a) 20mm dia bore
(b) 25mm dia bore
(c) 40mm dia bore
(d) 50mm dia bore.
Supply and fixing in replacement of DI D/F Gate valve (Soft Sealed) Resilient Seated Soft Sealing gate valves (Sluice valves RAISING TYPE) with body bonnet of ductile cast iron of grade GGG-40/SG- 400/15 or GGG-50/SG-500/7 or equivalent grade as per IS 3896 - Part 2- 1985 and subsequent revisions, Wedge fully rubber lined with EPDM Food grade quality and Seals of NBR and the valve should be vacuum tight and 100 % leak proof with face to face dimension as per BS 5163-89/IS 14846-2000/DIN 3202 F 4. and Valves should be electrostatic powder coating both inside and outside pocket less body passage class PN 1.6 including all jointing materials (Gasket, Nut bolts etc) connecting and testing complete all as specified and directed. Note : OLD SRRVICEABLE VALVES TO BE DEPOSITED TO the DEPARTMENT store FOR FURTHER USE as directed by Engr-In-Charge)
150 mm Dia
200 mm Dia
300 mm dia
M&L Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) as in foundation, PCC, protection of pipe etc., complete all as specified and as directed.
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvanised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Crystalline Conductive Material (CCM). The GI electrode shall be surrounded with 25 kg Backfill compound to provide maximum contact between the electrode and Back Fill Compound. The earthing pit should be cover with PCC (1:2:4, B1) cover,of 450 x 450 mm complete all as specified and directed make ASHLOK / INDELEC/JMV /TERCEL/True Power.
S&F in replacement Transceiver automation for the water level Detector and controller with the feature mentioned here under:- 1. S& F in replacement of Transceiver must communicate at a distance of 3km -5kms range with each module must have the LORA/GSM or suitable communication module (long range antenna) must work above 500 mhz and each module shall have a processor module connecting to the sensor, with the facility that the processor module to sense the low level (10-20%) and high level of the water level (90-100%) so as to raise the hooter and communicate with the other hardware modules with antennas. S&F transducer module wiring through the D sub connectors (MIL industrial grade are to be used). All the wiring must be shielded optical co-axial cable for connection to flasher and hooter. Rates quoted are deemed to be included for suitable flasher and hooter.
Contd... S&F Hooter 12V/5 Amp with suitable converter or hooter suitable for 230V AC Supply must be provided standard suspended rust proof stand Note: All the NPT cable glands must be used for the sensor interface and MCB controller board. S&F 12V flasher with suitable converter or flasher suitable for 230V AC Supply connected with suitable 3 Core Co axial cable suitably crimped nicomatic connector. Note: All the cables to be drawn through suitable medium grade conduit suitably fixed with clamps. S &F of LED display board with superior night vision display to be provided at the receiver station. S&F controller Board confirming to IP 65 protection 3D printed with EMI/EMC compatible FE 32 material for the enclosure. All the 3D/CAD models must be provided for review before the enclosure are fitted with AUTO CAD/PRO drawings shall be provided. Note: Complete system shall be warrantied with 24 hrs rectification for any non functioning for a period of 1 year replacement warranty. (a) One transmitter for over Head Tank and one receiver for Pump House .
Supply only Bleaching powder Grade-I, IS 1065:1989(used in drinking water), stable dry free flowing white in appearance without hard lumps and visible impurities in laminated high density polythene bags of 25 Kgs capacity of each bags. Notes (i) Contractor shall supply material as per monthly requirement basis in bags/containers as and when directed by Engr-in-Charge at various installation of AGE E/M No-II. (ii) The quoted rate is deemed to be included complete labour and transportation for the materials at various installations of AGE E/M No II with out any extra cost.
Supply and fixing in replacement of New water meters are confirming to ISO 4064:2005, including MS flange, nut bolts, rubber packing and flange thickness conforming to IS:7322-1985 and flange dimension conforming IS: 1538-1993 of size 300 mm dia MS/DI/CI pipe line, by cleaning and grinding by 3 core welding of the pipe outside welding of the joint including cost of gas oxygen acetylene, welding machines, skilled and semi skilled workers internal lighting arrangements and all other incidental and operational charges etc., complete all as directed by Engineer in Charge.
Supply and fixing in replacement and lay pipes MS BLACK ERW steel including specials having nominal dia 300 MM (outer dia 466 MM) and 8 MM Thick as per IS 3589-2001 Grade- 330 with plain ends and specials by welding, leak arresting of line laid in trenches / floors / walls / duct / open complete all as specified and directed including taking down old unserviceable MS Pipe. Note : Quoted rate is inclusive of supply and fixing of flange and bends of suitable size as required, welding, cutting etc as required for fixing of pipe
S&F in replacement MCCB along with both side spreader link and nut bolts of appropriate size in existing LT Panel box / feeder pillar box (KIOSK) of capacity 400 Amps 4 pole 35 KA 415 Volt including disconnecting / taking out existing old unserviceable / burnt MCCB complete all as specified and directed.
S&F in replacement MCCB along with both side spreader link and nut bolts of appropriate size in existing LT Panel box / feeder pillar box (KIOSK) of capacity 250 Amps 4 pole 35 KA 415 Volt including disconnecting / taking out existing old unserviceable / burnt MCCB complete all as specified and directed.
Supply and fix in wall mounted name plate of motors by using acrylic sheet 3 mm thick of size 45 CM X 30 CM mentioning capacity of motors, Serial No, Year of installation etc by using colour strip complete all as directed by Engineer-in-Charge
Supply and fix in replacement of digital ammeter 0-400 amps in existing panel board Including CT set of three complete all as directed incl taking down old one .
Supply and fix in replacement of digital Voltmeter 0-500 Volt in existing panel board size as per the existing complete all as directed incl taking down old one .
Supply in replacement of the following spares suitable for make existing at site of pump 6 stage 125 LPS capacity for repairs complete all as specified and directed :-
Pump shaft suitable for 6 stage impeller of capacity 125 LPS
Cast Iron impeller stage suitable for capacity 125 LPS pump
Cast Iron bearing housing for drive for pump capacity 125 LPS Model No B C 21Y 033
Cast Iron shaft sleeve for drive end for pump capacity 125 LPS
Cast Iron shaft sleeve for non drive end for pump capacity 125 LPS
Stuffing box bush cast iron for pump
Cast iron gland set of 2 halves for pump of capacity 125 LPS.
Non drive end bearing of suitable capacity of Pumps :- Pump capacity 240 HP. Make : SKF equivalent suitable for the Pump as approved by GE.
Drive end bearing of suitable capacity of Pumps :- Pump capacity 240 HP. Make : SKF equivalent suitable for the Pump as approved by GE.
Supply and fixing in replacement and lay pipes MS BLACK ERW steel including specials having nominal dia 150 MM (outer dia 466 MM) and 8 MM Thick as per IS 3589-2001 Grade- 330 with plain ends and specials by welding, leak arresting of line laid in trenches / floors / walls / duct / open complete all as specified and directed including taking down old unserviceable MS Pipe. Note : Quoted rate is inclusive of supply and fixing of flange and bends of suitable size as required, welding, cutting etc as required for fixing of pipe
Supply and fixing in replacement and lay pipes MS BLACK ERW steel including specials having nominal dia 200 MM (outer dia 466 MM) and 8 MM Thick as per IS 3589-2001 Grade- 330 with plain ends and specials by welding, leak arresting of line laid in trenches / floors / walls / duct / open complete all as specified and directed including taking down old unserviceable MS Pipe. Note : Quoted rate is inclusive of supply and fixing of flange and bends of suitable size as required, welding, cutting etc as required for fixing of pipe
SUN LIGHT HOUSE (BID ID -3361662)
sree venkateswara enterprises (BID ID -3362798)
Srinivash Engineers (BID ID -3358727)
sandhya enterprises (BID ID -3371157)
Srinivasa Consructions (BID ID -3362797)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .