Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC | L1 | Accepted-AOC Accepted due to L1 | |
| 2 | L2₹15.3 L+₹1.5 L (10.9%)Rejected-AOC | L2 | Rejected-AOC Higher rate | |
| 3 | L3₹16.2 L+₹2.4 L (17.6%)Rejected-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-AOC Higher rate | |
| 4 | L4₹21.0 L+₹7.2 L (52.3%)Rejected-AOC FLAT NO 602 THE ELEPHANT HEAD CGHS LTD PLOT NO 41 OPP AYUSHMAN HOSPITAL DWARKA SECTOR 10 SOUTH WEST DELHI 110075 | SOUTH WEST | DELHI | 110075 | L4 | Rejected-AOC Higher rate | |
| 5 | L5₹21.5 L+₹7.8 L (56.3%)Rejected-AOC WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | L5 | Rejected-AOC Higher rate |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
27 Aug 2021, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI
REPAIR MAINTENANCE OF CERTAIN EM FITTINGS FIXTURES AND INTERNAL WIRINGS AS WELL AS SUBMAIN WIRING LT PANEL AT CERTAIN BUILDINGS OF TPT UNIT IHQ ARMY ASC UNDER GE NEW DELHI
2021_MES_463983_1
GE/ND-40/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NEW DELHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NEW DELHI
₹47,000
Yes
30 Oct 2021
30 Jul 2021
3 Sept 2021
30 Jul 2021
27 Aug 2021
13 Aug 2021
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M&L for point wiring with PVC FRLS insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm 1100 V grade including one run of PVC insulated unsheathed multi stranded copper conductor of size 1.5 sqmm as earth continuity conductor connected to common earth dolly, in existing conduits and its accessories, including replacement of factory made steel boxes suitable for modular switch/sockets including modular plates of suitable size as per site requirement for the following Note: Cutting & chasing, if required, shall be measured/paid under relevant items
One light/ceiling fan/exhaust fan point controlled by one no. one way switch, 5/6 amps.
One bell / buzzer point controlled by one bell push
One 3 pin 5 Amps socket outlet point controlled by one no. one way switch, 5/6 amp, on independent board.
One 3 pin 5 Amps socket outlet point controlled by one no. one way switch, 5/6 amp on same board.
All as per item No 2.00 here-in-before but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 amp socket outlet point on independent board as specified and directed by Engineer in Charge
All as per item No 2.00 here-in-before but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core cable on independent circuit as specified and directed by Engineer in Charge
M&L for point wiring with PVC FRLS insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm 1100 V grade including one run of PVC insulated unsheathed multi stranded copper conductor of size 1.5 sqmm as earth continuity conductor connected to common earth dolly, in and including PVC conduit of suitable sizes of medium grade ISI marked for surface wiring and its accessories, including MS sunken box and hylem sheet of suitable size, ISI marked for housing the switches and sockets, for the following :-
One light/fan/exhaust fan point controlled by one nos, one way switch 5/56 amp
One three pin 5 Amp socket outlet point controlled by one no, one way switch 5/6 amp on independent board
One bell / buzzer point controlled by one bell push
One three pin 5 Amp socket outlet point controlled by one no, one way switch 5/6 amp on same board
All as per item No. 5.00 here-in-before but with 2.5 sqmm (for phase, neutral) and 2.5 sqmm (for continuous earth wire) cable for one 15/16 amp socket out let point on independent board.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc., and making good, cutting not exc. 10 cm girth on brick walls complete all as specified and as directed.
S&F Modular switch 6 amps 250 V AC one way with ISI mark including 6 amps switch frame complete all as specified and as directed.
S&F modular switch 16 A SP one way 240 volts complete all as specified and as directed.
S&F modular socket 6 A Multi socket for 2/ 3 pin 240 volts complete all as specified and as directed.
S&F modular bell push 6A with Neon 1 module 240 volts complete all as specified and as directed.
S&F modular socket 15 A Multi socket for 2/ 3 pin 240 volts complete all as specified and as directed.
S&F switch piano flush button single pole one way 6 amps complete all as specified and as directed.
S&F switch piano flush type 15 amps single pole one way complete all as specified and as directed.
S&F socket outlet 5/6 amps 2 in 1, 3 pin flush type complete all as specified and as directed.
S&F socket outlet 2 in 1, 3 pin 5 and 15 amp, flush type complete all as specified and as directed.
S&F bell push ,flush type 5 A 240 volts complete all as specified and as directed.
S&F electric bell Ding-Dong AC 230 Volt comlete complete all as specified and as directed.
S&F ceiling rose, 3 phase/ PVC/ polycarbonate isolated body complete all as specified and as directed.
S&F in replacement of factory made load line DBs double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 4 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB upto 125 A as incomer & MCB SP/TP as outgoing complete all as specified and directed.
S&F in replacement of factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB upto 125 A as incomer & MCB SP/TP as outgoing complete all as specified and directed.
Taking down DB of SPN 4 8/12 way type removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls etc. complete all as specified and directed.
S&F sheet metal enclosures for DBs when MCB to be used, SPN double door 240 volt, 12 way with 200 amps rated bus bar complete all as specified and directed.
S&F sheet metal enclosures for DBs when MCB to be used, SPN double door 240 volt, 4 way with 200 amps rated bus bar complete all as specified and directed.
S&F sheet metal enclosures for DBs when MCB to be used,SPN double door 240 volt, 8 way with 200 amps rated bus bar complete all as specified and directed.
Taking down MCCBs, any type, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls/pannel etc. complete all as specified and as directed.
Supply and fixing MCCB, 4 pole, 415 volt of capacity 125A breaking capacity not less than 25kA, Icu=100% Ics thermal magnetic type adjustable type 80 to 100 % confirming to IEC-60947-II, IS-13947-II , including thimbles, nuts, bolts, washers etc and connections, replacement of thimbles, minor parts like nuts bolts washer etc. complete all as specified and as directed.
Supply and fixing MCCB, 4 pole, 415 volt of capacity 250 Amp, breaking capacity not less than 36 kA , Icu=100% Ics thermal magnetic type adjustable type 80 to 100 % confirming to IEC-60947-II, IS-13947-II , including thimbles, nuts, bolts ,washers etc and connections, replacement of thimbles, minor parts like nuts bolts washer etc. complete all as specified and as directed.
Taking down MCB 6-32/40-63 Amps SP/SPN and 40-63 Amps TPN type removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls etc. complete all as specified and as directed.
S&F MCB SPN 40 to 63 Amp 240 volt 10 kA rupturing capacity, series C, complete all as specified and directed.
S&F MCB TPN 40 to 63 Amp 240 volt 10 kA rupturing capacity, series C, complete all as specified and directed.
S&F MCB SP 40 to 63 Amp 240 volt 10 kA rupturing capacity, series C, complete all as specified and directed.
S&F MCB SPN 6 to 32 Amp 240 volt 10 kA rupturing capacity, series C, complete all as specified and directed.
S&F MCB SP 6 Amp to 32 Amp, 240 V, 10 kA rupturing capacity, series C, complete all as specified and directed.
Taking down Metal clad enclosure with plug and socket 10/20 Amps removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls etc. complete all as specified and as directed.
S&F sheet Metal enclosure with plug and socket 10 Amp 240 volts with one MCB single pole kA rupturing capacity, series C, complete all as specified and directed.
S&F sheet Metal enclosure with plug and socket 20 Amp 240 volts with one MCB single pole kA rupturing capacity, series C, complete all as specified and directed.
S&F in replacement LED batten of 18 Watt 230Volt (size 4 ft) , box type complete with LED Tube Light 18 Watt & all accessories internally prewired including connecting up with three core sheathed flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in replacement of Endura Linear LED batten of 9 W (2 ft.), extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver in AC complete all as specified and as directed.
S&F in replacement aesthetically designed Wall mounted decorative wall LED light of 16 W fixture with opal diffuser to give glare free light including material of body floral blown glass metal ,suitable LED lamp of 2x8 W having Lamp base E27 complete all as specified and as directed.
S&F in replacement of cast aluminium housing, powder coated LED bulkheads light fitting 10watts with frosted diffuser complete with suitable driver complete all as specified and as directed. Make:CG Cat Part No LBHE-10-CDL, Halonix cat-HLBH-02-10-CW, Bajaj Cat Part No B1BWP10LED
Supply & fix in replacement 1x4 Panel light surface mounted LED light of 36 W fixture with opal diffuser to give glare free light including suitable LED light of 36 W complete all as specified.
Supply & fix in in replacement 2x2 Panel light surface mounted LED light of 36 W fixture with opal diffuser to give glare free light including suitable LED light of 36 W complete all as specified.
Supply & fix in replacement aesthetically designed recessed/surface mounted decorative downlighter LED light of 12 W fixture with opal diffuser to give glare free light including suitable LED lamp of 12 W complete all as specified and as directed.
Supply & fix in replacement aesthetically designed recessed/surface mounted decorative downlighter LED light of 15 W fixture with opal diffuser to give glare free light including suitable LED lamp of 15 W complete all as specified and as directed.
Supply and fix in replacement Metal clad plug top of capacity 20 Amp, 240 volts complete all as specified and directed.
Supply and fix in replacement Metal clad socket of capacity 20 Amp, 240 volts complete all as specified and directed.
Supply and fix in replacement decorative laminated sheet 3mm thick of size 8'' X 12'' including necessary cutting of sheet for fixing switch / socket complete as specified and directed.
Supply and fix in replacement decorative laminated sheet 3mm thick of size 8'' X 5'' including necessary cutting of sheet for fixing switch / socket complete as specified and directed.
Supply and fix in replacement only decorative laminated sheet 3mm thick of size 7'' X 4'' including necessary cutting of sheet for fixing switch / socket complete as specified and directed.
Supply and fix in replacement decorative laminated T cover sheet 3mm thick of size 2/3 inch dia complete all as specified and directed.
S&F in replacement STEP type electronic fan regulator flush type 230 volts complete all as specified and directed.
S&F electronic fan regulator modular type 100 Watt step type Double Modular complete all as specified and directed.
Supply and fix in replacement fan capacitor of the following capacity :-
Supply and fix in replacement non metallic rigid PVC conduit medium grade 20 mm dia, ISI Mark complete all as specified and directed
Supply and fix in replacement non metallic rigid PVC casing caping, ISI Mark complete all as specified and directed.
Taking down of ceiling fan/ exhaust fan dismantling of blades, transportation to workshop and carrying out for rewinding, transportation to site, reinstallation and testing complete.
M&L for Rewinding of ceiling fan 1200/1400/1600 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush, ball bearing wherever required complete all as specified and as directed.
All as per ser item No 58.00 here-in-before but exhaust fan 230/300 mm sweep
S&F ceiling fan Ball bearing of suitable size & model (as per sample).
M&L for replacing U' clamps with rubber reel, bolts, nuts, washers and safety pin ceiling fan of any size complete all as specified and as directed.
M&L in repair for Down rod of 1' height fabricated out of MS pipe 12mm dia heavy duty duly painted with one coat of white paint complete all as specified and as directed.
S&F in repair Canopy of Ceiling fans of 1200/1400/1600 mm swipe size heavy duty duly painted with one coat of white paint complete all as specified and as directed.
M&L for spray painting (white colour) with synthetic enamel paint to Ceiling fans/Exhaust fan of any capacity to reach upto satisfied finish of painting after cleaning and preparation of surface and marking MES No with black paint complete all as specified and as directed.
Supply & fixing in repair flat ceiling fan blade of aluminium, 1mm thickness suitable for 1200mm sweep ceiling fan,12-15 deg tilted,having 3 Nos in each set complete all as specified and as directed.
Supply & fixing in repair flat exhaust fan blade of aluminium, 1mm thickness suitable for 230/250/300mm sweep exhaust fan,12-15 deg tilted,having each set complete all as specified and as directed.
S&F in repair of Frame of 230/250/300 mm metallic exhaust fan including taking down of old frame complete all as specified & dircted.
Supply & fixing in replacement flat ventilation fan blade of PVC , 1mm thickness suitable for 230/250/300mm sweep exhaust fan,12-15 deg tilted, having each set all as specified as directed by Engg-in-charge.
S&F ventilation fan motor of size 230/250/300 including taking down of old ventilation fan motor complete all as specified and directed.
S&F Frame of 230/250/300 mm ventilation fan including taking down of old frame complete all as specified and as directed.
Taking down carefully Geysers 25 Ltr capacity, opening for inspection, , cleaning, descaling, reassembling and refixing in position after carrying out repairs like soldering/ brazing etc including replacement of pressed rubber gasket, Nuts, bolts, neon indicator lamp 1 Amp etc.
Taking down carefully Geysers 50 Ltr capacity, opening for inspection, , cleaning, descaling, reassembling and refixing in position after carrying out repairs like soldering/ brazing etc including replacement of pressed rubber gasket, Nuts, bolts, neon indicator lamp 1 Amp etc.
M&L for spray painting (white colour) with synthetic enamel paint to Geysers 25 Liters capacity to reach upto satisfied finish of painting after cleaning and preparation of surface and marking MES No with black paint complete all as specified and directed by Engineer-in-charge.
M&L for spray painting (white colour) with synthetic enamel paint to Geysers 50 Liters capacity to reach upto satisfied finish of painting after cleaning and preparation of surface and marking MES No with black paint complete all as specified and directed by Engineer-in-charge.
M&L heating element of 2.0 KW (Circular) as required at site including rubber washers (ISI marked) etc (As per sample) complete all as specified and as directed.
M&L heating element of 2.0 KW (triangular) as required at site including rubber washers (ISI marked) etc complete all as specified and as directed.
S&F storage tank made out of copper sheet of appropriate thickness and confirming to IS 208 (1974) for 50 litre capacity geysers with collar complete duly tested at required pressure as per IT I of 1986 of steel storage tank complete all as specified and as directed.
S&F storage tank made out of copper sheet of appropriate thickness and confirming to IS 208 (1974) for 25 litre capacity geysers with collar complete duly tested at required pressure as per IT I of 1986 of steel storage tank complete all as specified and as directed.
M&L for replacement of insulating material (Glass wool) for 25/ 50 litre capacity Geysers complete all as specified and as directed.
S&F base plate assembly 20 SWG heavy duty suitable for 50 litre capacity copper tank geyser with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element including clamps for holding the element with nuts, bolts and safety valves suitable for all type of geysers installed at site (As per sample) complete all as specified and as directed.
S&F base plate assembly 20 SWG heavy duty suitable for 25 litre capacity copper tank geyser with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element including clamps for holding the element with nuts, bolts and safety valves suitable for all type of geysers installed at site (As per sample) complete all as specified and as directed.
M&L chromium plated copper connection pipe 600/1000 mm long with two brass adopters washers and connecting up complete all as specified and directed.
M&L safety nut for high pressure release (As per sample) complete all as specified and as directed.
M&L top cover for geysers of 25/50 ltrs capacity any make as required at site duly painted with two coats of Synthetic enamel spray paint (first quality) complete all as specified and as directed.
S&F bottom cover for geysers of 25/50 ltr any make required at site duly painted with synthetic enamel spray paint (first quality) with inspection plate in two pieces complete all as specified and as directed.
S&F of outer cover for geyser made out of MS sheet suitable for 50 ltrs capacity geyser vertical/horizontal type complete all as specified and as directed.
S&F of outer cover for geyser made out of MS sheet suitable for 25 ltrs capacity geyser vertical/horizontal type complete all as specified and as directed.
S&F thermostat (ISI Marked) for 25/50 Liters capacity Geyser complete all as specified and as directed.
S&F indicator lamp (Red & Green) 230 volts suitable for Geyser (as per sample) complete all as specified and as directed.
Supply and fix mild steel hole fastener 10mm dia, 100mm long including nut and washer complete all as specified and as directed.
S&F in replacement lamp holder, PVC /polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and as directed.
S&F in replacement LED Bulb inverter type 15 watt suitable for fitting in pendant holder complete all as specified and as directed.
S&F in replacement gang box two module suitable for fiting one 5 Amp switch /socket complete all as specified and as directed.
S&F in replacement gang box four module suitable for fiting one 5A switch and one socket complete all as specified and as directed.
S&F in replacement gang box four module suitable for fiting one 15A switch and one socket complete all as specified and as directed.
M&L in replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burid in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32X6 mm galvanised iron strip complete all as specified and as directed.
Taking down submain wire of 6/10 sqmm Al/Cu to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls etc. complete all as specified and as directed.
S&F submain wiring alongwith earth wire with 2 run of 6 Sqmm (Main Cable and neutral) and one run of 6 Sqmm as earth wire of FRLS PVC insulated copper conductor, single core cable drawn through and including rigid PVC conduit of 20 mm bore with all fittings accessories complete all as specified and as directed.
S&F submain wiring alongwith earth wire with 2 run of 10 Sqmm (Main Cable and neutral) and one run of 10 Sqmm as earth wire of FRLS PVC insulated copper conductor, single core cable drawn through and including rigid PVC conduit of 20 mm bore with all fittings accessories complete all as specified and as directed.
Grid Infratech Pvt Ltd
RUCHIKA ENGG.WORKS
NEERU ELECTRICALS
M/S Sunil Steel Works
Surjit and Sons
SANJEEV ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .