| 1 | ELECTRICAL PREVENTIVE MAINTENANCE AMC MONTHLY CHARGES | DAILY ELECTRICAL OPERATIONS or SERVICES ON ROUND THE CLOCK BASIS FOR ALL DAYS OF THE YEAR INCL. SUNDAYS AND HOLIDAYS AT ONE MANPOWER EACH IN 3 SHIFTS AND THE OFF-RELIEVER IN GENERAL SHIFT ON NON-OFF DAYS AS PER ATTACHED SCOPE OF JOB, SPECIAL TERMS and CONDITIONS, ETC. The vendor shall engage or nominate a qualified and experienced supervisor who can understand the instructions given by Officer-in-charge and can read and write and take instructions from officer-in-Charge. The contractor shall engage a qualified supervisor having Grade C license in the depot for supervising the work in general shift on Depot working days. The contractor shall engage qualified and experienced electricians on 24hrs x 7days. The electricians should have the required qualification and wireman license as per IE rules and state electricity board requirement. At least one qualified electrician to be engaged in 3 shifts from 6 am to 2 pm, 2 pm to 10 pm and 10 pm to 6 am for all days of month. One qualified Electrician shall be arranged by the Contractor for reliever duty as per statutory requirement. As per state minimum wages revison on April 2023, Minimum wages to Electrician (skilled category,Class B city) is Rs.27367/- per month. For 5 persons, a minimum Base amount to be quoted against the line is Rs.149396/- per month. any vendor quoting lesser than this amount in the tender will be disqualified. | 12 | Month | arunkthomas | 365 |
| 2 | | CARRYING OUT TESTING OF EARTH PIT BY CALIBRATED MEGGER or EARTH TESTER AND FURNISHING THE TYPE OF EARTHING, RESISTANCE VALUE (OHMS), DATE OF TEST AND DUE DATE OF TESTING. THE JOB ALSO INCLUDES SUPPLY OF STICKER AND DISPLAYING IN EXISTING MILD STEEL BOARD NEAR EARTH PIT. | 600 | Number | arunkthomas | 365 |
| 3 | THERMOGRAPHY TEST FOR TRANSFORMER | CHARGES TOWARDS THERMOGRAPHY OF 500KVA TRANSFORMER INSTALLED AT HPCL COIMBATORE IRD. JOB INCLUDS ALL TOOLS, TACKLES AND EQUIPMENT AND SUBMISSION OF REPORTS AS PER SCOPE OF JOB. ONLY VENDORS HAVING CLASS A LICENSE SHALL BE ENGAGED FOR CONDUCTING THE TESTS. JOB INCLUDES (BUT NOT LIMITED TO) OPENING OF TERMINAL BOXES OF MOTORTRANSFORMERS, PANEL COVERS, CLEANING OF CONTACTS WITH CRC, APPLICATION OF PETROLEUM JELLY OR GREASE TO THE NUTS AND BOLTS, CONNECTION AND DISCONNECTION OF CABLES AT BOTH ENDS AND ENSURING PROPER TIGHTNESS AFTER RECONNECTIONS, ASSURING THE FLP NATURE OF THE EQUIPMENTS ETC. | 2 | Number | arunkthomas | 365 |
| 4 | AIR CIRCUIT BREAKER TESTING AND SERVICING | TESTING AND SERVICING OF AIR CIRCUIT BREAKERS ISNTALLED AT COIMBATORE IRD. VENDOR SHALL ARRANGE FOR ALL TOOLS, TACKLES AND EQUIPMENT FOR TESTING AND CALIBRATION AND INCLUDES SUBMISSION OF REPORTS AS PER SCOPE OF JOB. JOB INCLUDES (BUT NOT LIMITED TO) OPENING OF TERMINAL BOXES OF MOTORS, PANEL COVERS, CLEANING OF CONTACTS WITH CRC, APPLICATION OF PETROLEUM JELLY OR GREASE TO THE NUTS AND BOLTS, CONNECTION AND DISCONNECTION OF CABLES AT BOTH ENDS AND ENSURING PROPER TIGHTNESS AFTER RECONNECTIONS, ASSURING THE FLP NATURE OF THE EQUIPMENTS ETC. | 6 | Number | arunkthomas | 365 |
| 5 | CALIBRATION OF ENERGY,VOLT,AMPS METER | CALIBRATION OF EXISTING ENERGY METER AND OTHER MULTI FUNCTION METERS INSTALLED AT COIMBATORE IRD. VENDOR SHALL ARRANGE FOR ALL TOOLS, TACKLES AND EQUIPMENT FOR TESTING AND CALIBRATION AND INCLUDES SUBMISSION OF REPORTS AS PER SCOPE OF JOB. JOB INCLUDES (BUT NOT LIMITED TO) OPENING OF TERMINAL BOXES OF METERS, PANEL COVERS, CLEANING OF CONTACTS WITH CRC, APPLICATION OF PETROLEUM JELLY OR GREASE TO THE NUTS AND BOLTS, CONNECTION AND DISCONNECTION OF CABLES AT BOTH ENDS AND ENSURING PROPER TIGHTNESS AFTER RECONNECTIONS, ASSURING THE FLP NATURE OF THE EQUIPMENTS ETC. | 50 | Number | arunkthomas | 365 |
| 6 | CONTINUITY TEST-DECANTING HOSE | PRODUCT UNLOADING HOSE PIPE CONTINUITY CHECKING WITH MEGGER. VENDOR SHALL ARRANGE FOR ALL TOOLS, TACKLES AND EQUIPMENT FOR TESTING AND CALIBRATION AND INCLUDES SUBMISSION OF REPORTS AS PER SCOPE OF JOB. CHECKING SHALL BE DONE ONCE IN SIX MONTHS | 700 | Number | arunkthomas | 365 |
| 7 | IR VALUE TESTING OF CABLES,MOTORS | TESTING OF INSULATION AND WINDING RESISTANCE VALUES OF ALL MOTORS, TRANSFORMER, POWER CABLES CONNECTED TO THESE MOTORS AND OTHER POWER CABLES TO VARIOUS OFFICE BUILDINGS, FIELD EQUIPMENTS, HIGH MASTS, ETP ETC. ONCE IN SIX MONTHS AND SUBMITTING THE REPORTS TO HPCL OFFICER INCHAGRE. JOB INCLUDES (BUT NOT LIMITED TO) OPENING OF TERMINAL BOXES OF MOTORS, PANEL COVERS, CLEANING OF CONTACTS WITH CRC, APPLICATION OF PETROLEUM JELLY OR GREASE TO THE NUTS AND BOLTS, CONNECTION AND DISCONNECTION OF CABLES AT BOTH ENDS AND ENSURING PROPER TIGHTNESS AFTER RECONNECTIONS, ASSURING THE FLP NATURE OF THE EQUIPMENTS ETC. | 2 | Number | arunkthomas | 365 |
| 8 | TAN DELTA TESTING OF TRANSFORMER | CALIBRATION OF RESISTANCE AGAINST FIXED VOLTAGE FOR TAN DELTA & RESISITIVITY INSTRUMENT. VENDOR SHALL ARRANGE FOR ALL TOOLS, TACKLES AND EQUIPMENT FOR TESTING AND CALIBRATION AND INCLUDES SUBMISSION OF REPORTS AS PER SCOPE OF JOB. ONLY VENDORS HAVING CLASS A LICENSE SHALL BE ENGAGED FOR CONDUCTING THE TESTS. JOB INCLUDES (BUT NOT LIMITED TO) OPENING OF TERMINAL BOXES OFTRANSFORMERS, PANEL COVERS, CLEANING OF CONTACTS WITH CRC, APPLICATION OF PETROLEUM JELLY OR GREASE TO THE NUTS AND BOLTS, CONNECTION AND DISCONNECTION OF CABLES AT BOTH ENDS AND ENSURING PROPER TIGHTNESS AFTER RECONNECTIONS, ASSURING THE FLP NATURE OF THE EQUIPMENTS ETC. | 1 | Number | arunkthomas | 365 |
| 9 | OIL FILTRATION OF TRANSFORMER | OIL FILTRATION AND BREAK DOWN VOLTAGE TESTING OF TRANSFORMER. ONLY VENDORS HAVING CLASS A LICENSE SHALL BE ENGAGED FOR CONDUCTING THE TESTS. VENDOR SHALL ARRANGE FOR ALL TOOLS, TACKLES AND EQUIPMENT FOR TESTING AND CALIBRATION AND INCLUDES SUBMISSION OF REPORTS AS PER SCOPE OF JOB. JOB INCLUDES (BUT NOT LIMITED TO) OPENING OF TERMINAL BOXES OF TRANSFORMER, PANEL COVERS, CLEANING OF CONTACTS WITH CRC, APPLICATION OF PETROLEUM JELLY OR GREASE TO THE NUTS AND BOLTS, CONNECTION AND DISCONNECTION OF CABLES AT BOTH ENDS AND ENSURING PROPER TIGHTNESS AFTER RECONNECTIONS, ASSURING THE FLP NATURE OF THE EQUIPMENTS ETC. | 2 | Number | arunkthomas | 365 |
| 10 | | TESTING AND CALIBRATION OF RELAYS INSTALLED AT COIMBATORE IRD. RELAY TESTING FOR DOL CONTACTOR. RELAYS TESTING INCLUDES THE FOLLOWING APPLICABLE JOBS FOR RELAYS ASSOCIATED WITH CONTACTOR OPERATED FEEDERS - 1)PROTECTION RELAYS TESTING BY SECONDARY INJECTION. 2)TRIP CIRCUIT CHECKING. 3)RELAY TERMINALS TIGHTENING. VENDOR SHALL ARRANGE FOR ALL TOOLS, TACKLES AND EQUIPMENT FOR TESTING AND CALIBRATION AND INCLUDES SUBMISSION OF REPORTS AS PER SCOPE OF JOB. JOB INCLUDES (BUT NOT LIMITED TO) OPENING OF TERMINAL BOXES OF MOTORS, PANEL COVERS, CLEANING OF CONTACTS WITH CRC, APPLICATION OF PETROLEUM JELLY OR GREASE TO THE NUTS AND BOLTS, CONNECTION AND DISCONNECTION OF CABLES AT BOTH ENDS AND ENSURING PROPER TIGHTNESS AFTER RECONNECTIONS, ASSURING THE FLP NATURE OF THE EQUIPMENTS ETC. | 100 | Number | arunkthomas | 365 |