Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 LAccepted-AOC | L1 | Accepted-AOC Being the L1 bidder | |
| 2 | L2₹3.6 L+₹16,409 (4.76%)Rejected-Finance | L2 | Rejected-Finance Being L2 and unsuccessful bidder |
Tender Value
₹3.9 L
Closing Date
1 Sept 2021, 3:00 pmClosed
Executive Engineer (E), BSNL, Bhubaneswar
Room no.317, 3rd Floor, Door Sanchar Bhawan, Unit-IX, Bhubaneswar-751022
Providing Electrical wirings and fittings and misc . works
2021_BSNL_85700_1
NIT NO- 44 /BSNL/BSR/2021-22
Open Tender
Electrical Works
Item Rate
15 days
Bhubaneswar
3 documents required · 3 mandatory
₹0
Exempted
20 Sept 2021
23 Aug 2021
2 Sept 2021
23 Aug 2021
1 Sept 2021
23 Aug 2021
23 Aug 2021 - 27 Aug 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group-C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
4X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1 x 1.5 sq. mm
2 x 1.5 sq. mm
3 x 1.5 sq. mm
2 x 4 sq. mm
3 x 4 sq. mm
4 x 4 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75 mmX75 mm)
3 Module (100 mmX75 mm)
6 Module (200 mmX75 mm)
8 Module (125 mmX125 mm)
12 Module (200 mmX150 mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
20A 1 way Modular switch with Neon
6 pin 15/16 A socket outlet
Telephone socket outlet 1M
TV cable Socket 1M
RJ45 Jack with CAT6-2M
10A Modular Bell push switch with Neon
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
4 way (4 + 12), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way, Double door
Supplying and fixing following rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6-32Amps Single pole
6-32Amps Double pole
63Amps Double Pole
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply and fixing of wall mounted hood Kitchen Chimney of size 90cm, air suction capacity not less than 1250 CMH, touch/button control, auto clean, adjustable speed control, curved/straight glass, max noise level 58 db with LED lamps etc. suitable for operation on 230 volts 50Hz AC supply. (Make: Kutchina Wales DLX i/Glen model: 6055SS Glass/6062TS/6071SS Glass/Faber model: Stilus 3D Plus Max T2S2BK TC 90/Hindware model: Zavio90/Octavio90)
Supply and fixing of following ratings, 65000K LED light fittings suitable for operation on 140 volts to 270 volts AC, 50Hz i/c fixing and connection etc. as required. (Havells /Phillips / Surya / Polycab / Crompton)
15-22 watt Ultra slim square recess mounting 1'X1' LED panel 6500K with high brightness SMD LEDs as light source for glarefree homogenous illumination. (Make: Havells model: PLUTO1X1PLR15WLED857S / Phillips model 59109/ equivalent of Bajaj/Cromton/WIPRO)
12 watt ultra-slim, round-fit ceiling recessed light fixture with long-lasting LED light source and high-grade aluminium body. (Make: Havells model: EDGPRORDDLR12WLED857S / Phillips model 59521/ equivalent of Bajaj/Cromton/WIPRO)
18 watt 6500K LED Ceiling Circular (Surface type), round white. (Make: Havells model: LHEAABP71L1W018 / Phillips model 588973113/ equivalent of Bajaj/Cromton/WIPRO)
17 watt Super bright light slick and modern design wall LED light. (Make: Phillips model: ULTRON/Equivalent of havells/ Bajaj/Crompton/Wipro)
6 watt Rectangular LED wall lamp with Acrylic body, modern warm white. (Make: Smartway/SS)
20 watt surface / wall mounted LED Batten having Aluminium housing and integrated electronic driver
S/F of 400mm sweep superior quality Wall mounting fan with swing mechanism and speed regulator, connection, testing etc. complete as required. (Make- Havells: D'Zire HS/Equivalent of Usha/ Crompton)
Supply and installation of 15 Litre Capacity, rated power 1KW/2KW/3KW energy efficient 5 star rated storage, vertical wall mounted type water heater along with flexible connection pipes i/c connection of water inlet and outlet pipes, testing etc. as required. (Make: Puro Turbo DX of Havells/Equivalent of Bajaj/Cromton)
Supply and fixing of Ceiling Fan hooks on ceiling i/c cutting the CC and making good the damages etc. complete as required.
Installation of existing Ceiling fans i/c wiring the down rods with 2X1.5sqmm PVC insulated copper conductor single core cable, connection and testing etc. as required.
Installation of existing wall mounting fans on wall i/c connection and testing etc. as required.
Supply and fixing of 300mm sweep, 70 watt 230 volts 50Hz, 1380 rpm, 3/4 blades metal body (Make:Crompton/Almonard/Havells)
Dismantling the existing old/damaged wirings, fittings with down rods, fans, industrial socket outlet boxes and all electrical accessories after disconnection of electric power supply and handing over the same to the BSNL etc. complete as required. (At VIP suit no.1, Lounge and Dining)
Supply of 3.5X25sqmm 1.1KV grade LT XLPE insulated & PVC sheathed Aluminium conductor armoured cable etc. as requited.
Laying of 1no. PVC/XLPE insulated aluminium conductor armoured cable in recess of wall i/c cutting groove in the wall, making good the dames etc. as required.
Installation , testing , & commissioning of 1.5 TR Inverter Split A.C. Unit , mounting / Fixing of indoor & outdoor unit ,fixing of refrigerant piping with expanded polythene foam insulation, suitable size PVC pipe in wall crossings, laying of cable for interconnections and laying drain pipe of standard length which is supply along with AC unit, minor civil work i/c making holes on wall for laying refrigerant pipe lines, control cable and drain pipes and closing the extra openings with cement sand, making good the damages etc. as reqd.(Extra length of Refrigerant piping & cable shall be paid extra). (3nos in VIP suit no-1 and 3nos. in Lounge)
Providing and fixing of suitable size L- shaped powder coated MS bracket (2 nos. per set ) for fixing of the outdoor unit of the split A/C units and fixing on wall with anchor bolts, drilling holes etc. complete as reqd.
Providing & laying of additional refrigerant copper pipe for suction & discharge line (size not less than 1/4" & 1/2" dia ) or as recommended by the manufacturer along with expanded polythene foam insulation i/c cutting ,brazing /making joint etc as reqd. The measurement shall be taken on linear basis for one circuit which includes suction & discharge line & foam insulation.
Supplying & laying of following sizes PVC insulated & sheathed copper cable for electrical connection of indoor and outdoor units of ACs etc as reqd. (Finolex/L&T/Polycab/Havells)
4 core 2.5sqmm
3 core 2.5 sqmm
Providing and laying of additional drain pipe of size 20mm dia PVC braided/ solid (M class-ISI) along with all accessories and fixing on surface of wall with PVC saddles (if required) suitable for drainage of condensate water etc. as reqd.
Providing of additional R32/R22 refrigerant gas (if required) and charging into the Inverter AC unit etc. as reqd.
S/F of MCB protected Socket outlet 4 modules with metal box comprising of 01no. 25Amps socket and 01no. 25Amps Plug and 01no. 25Amps "C" series SPMCB for Split AC units i/c connection, testing etc. as required. (Make- Legrand /Havells/HPL/Standard)
Dismantling the Indoor and outdoor units of the Split AC units along with refrigerant pipe lines, drain pipes and electrical cable, channels etc. as required.
Dismantling the WAC units along with all accessories and shifting to the ground floor or as directed by the Engineer in charge etc. as required. Lounge-02nos, VIP Suit no.1-01no.)
Servicing of the Split AC units i/c chemical cleaning of indoor and outdoor units et. As required.
Repairing the indoor units of Split AC units i/c replacement of display units, blower motor capacitors etc. as required.
KISLAY KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .