Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹34.3 L+₹3.3 L (10.6%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹35.1 L+₹4.1 L (13.1%)Rejected-Finance C O SHRI AMRENDER KUMAR YADAV IACHHIPUR SANTOSH NAGAR GORAKHNATH GORAKHPUR UTTAR PRADESH PIN 273015 | GORAKHPUR | UTTAR PRADESH | 273015 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹36.7 L+₹5.7 L (18.4%)Rejected-Finance NURSERY SCHOOL 1 SECTOR 33 SUNCITY KURUKSHETRA ROAD KAITHAL 136027 HARYANA | KAITHAL | KAITHAL | HARYANA | 136027 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹41.6 L+₹10.6 L (34.1%)Rejected-Finance HOUSE NO 415 ALIKAN ROAD MANDI DABWALI SIRSA HARYANA 125104 | MANDI DABWALI | SIRSA | HARYANA | 125104 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
1 Feb 2025, 6:00 pmClosed
GE (Army) Suratgarh
GE (Army) Suratgarh Suratgarh
Repair to internal wiring and replacement of electrical fitting in certain Md Accn in MAP and KLP area under AGE EM at Suratgarh Mil Stn
2024_MES_690920_1
GE (A) SOG Token No -79/24-25
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Suratgarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(Army) Suragarh
₹90,000
Yes
13 Feb 2025
30 Dec 2024
3 Feb 2025
30 Dec 2024
1 Feb 2025
13 Jan 2025
Amount
Notes:- (i) 100 percent nonperishable items of the work shall be deposited by the L1 bidder within 30 days after placing of work order. (ii) The critical path network shall be submitted by L1 bidder immediately after the acceptance of tender and approved by GE. (iii) The bidders must ensure to visit the site, check relevant documents and makes of materials required to be incorporated under the subject from concern Engineer-in-Charge. (iv) Material obtained from demolition/dismantled and the serviceable material (other than reused in the work) shall be the property of the Govt and shall be removed and deposited in the MES Store Yard without any extra cost to Govt. (v) In case of non-availability of any make mentioned under list of Makes, the L1 Bidder shall obtain non-availability / non-manufacturing certificate from the concern OEM / authorised dealers and submitted to Accepting Officer, the L1 bidder may be incorporated Group-I category makes as approved by HQ CE SWC Jaipur / HQ CE BTZ in the works after prior approval of Accepting Officer. (vi) L1 Bidder shall produce E-way bill alongwith test certificate from OEM / manufacturer for costly items / major items of amount above Rs 50,000/- along with RAR’s and Final Bill. (vii) L1 Bidder shall be maintained an album containing Photos of all the material brought at site and each stage wise work progress and kept at site. Same shall be deposited in Engineer-in-Charge office after completion of work. (viii) The cost of all the above provisions shall be deemed to be included in the quoted rate of bidder, nothing extra shall be paid to the bidder.
Taking down carefully or drawing out from conduit, existing copper / aluminium point wiring for light, fan, bell, socket, power point etc complete including fixture and fittings such as switches, sockets, ceiling rose, pendent holder, light fittings, top sheet covers, fan regulators and making good the disturbed surfaces of wall/ceiling complete all as specified and as directed by Engineer-in-charge.
M&L for Modular point wiring including provn of inverter connection complete with 2.5 Sqmm (nominal cross section area) FRLSH PVC insulated multistranded unsheathed copper conductor cable drawn in and including concealed PVC rigid conduit medium grade 25 mm dia, pipe hooks, elbows, junction covers and junction boxes including cutting chases in walls and making good the disturbed surfaces of wall with all jointing accessories including provision of pressed steel modular sunken terminal boxes made of 1.2mm thick pressed steel sheet, 60mm deep of suitable length and painted with red oxide primer and modular decorative sheet cover including 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 02 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per serial item No. 02 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per serial item No. 02 here-in-before except provn of inverter connection but for One light point controlled by Two 2- way switches.
All as per serial item No. 02 here-in-before but for One bell or buzzer point controlled by by one push button on same board with other or independent switches
All as per Srl item No. 02 here-in-before except provn of invertor connection but wiring with cable of cross sectional area 4.0 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts for one socket outlet 6 pin, 5/15 Amps on independent board including 4.0 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F Modular switch piano flush type 6 Amps single pole, one way, complete all as specified and directed by Engineer-in-charge.
S&F Modular socket flush type 2 / 3 pin, 6 Amps, 230 volts, complete all as specified and directed by Engineer-in-charge.
S&F Modular switch piano flush type 5/6 Amps single pole, two way, complete all as specified and directed by Engineer-in-charge.
S&F Modular switch piano flush type 15/16 Amps single pole, one way, complete all as specified and directed by Engineer-in-charge.
S&F Modular socket flush type 2 / 3 pin,15/16 Amps, 230 volts, complete all as specified and directed by Engineer-in-charge.
S&F Modular bell push piano flush type 6 Amps single pole, one way, complete all as specified and directed by Engineer-in-charge.
S&F Modular electronic step type fan regulator suitable for ceiling fan of 1200mm / 1400mm sweep,2 Module complete all as specified and directed by Engineer-in-charge.
M&L for point wiring complete with 2.5 Sqmm (nominal cross section area) FRLSH PVC insulated multistranded unsheathed copper conductor cable drawn in and including concealed PVC rigid conduit medium grade 25 mm dia, pipe hooks, elbows, junction covers and junction boxes including cutting chases in walls and making good the disturbed surfaces of wall with all jointing accessories including provision of pressed steel sunken terminal boxes made of 1.2mm thick pressed steel sheet, 60mm deep of suitable length and painted with red oxide primer including 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 15 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per serial item No. 15 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per serial item No. 15 here-in-before but for One light point controlled by Two 2- way switches.
All as per serial item No. 15 here-in-before but for One bell or buzzer point controlled by by one push button on same board with other or independent switches
All as per Srl item No. 15 here-in-before but wiring with cable of cross sectional area 4.0 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts for one socket outlet 6 pin, 5/15 Amps on independent board including 4.0 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
M&L for point wiring complete with 2.5 Sqmm (nominal cross section area) FRLSH PVC insulated multistranded unsheathed copper conductor cable drawn in existing or open new PVC rigid conduit medium grade 25mm dia, pipe hooks, elbows, junction covers and junction boxes and making good the disturbed surfaces of wall with all jointing accessories including 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 21 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per serial item No. 21 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per serial item No. 21 here-in-before but for One light point controlled by Two 2- way switches.
All as per serial item No. 21 here-in-before but for One bell or buzzer point controlled by by one push button on same board with other or independent switches
All as per Srl item No. 21 here-in-before but wiring with cable of cross sectional area 4.0 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts for one socket outlet 6 pin, 5/15 Amps on independent board including 4.0 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F switch piano flush type 6 Amps single pole, one way, complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 2 / 3 pin, 6 Amps, 230 volts, complete all as specified and directed by Engineer-in-charge.
S&F switch piano flush type 6 Amps single pole, two way, complete all as specified and directed by Engineer-in-charge.
S&F switch piano flush type, 15 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 3/5 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F electronic step type fan regulator suitable for ceiling fan of 1200mm / 1400mm sweep,2 Module complete all as specified and directed by Engineer-in-charge.
S&F bell push, flush type, 5 Amp, 230 Volts grade complete all as specified and directed by Engineer-in-charge.
S&F electric bell (ding - dong), AC, 230 Volts, Single pole & connecting up complete all as specified and directed by Engineer-in-charge.
S&F Lamp holder, insulated body with back plate etc complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge.
M&L for Sub main wiring complete with 2 single core 6 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in medium duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 6 Sqmm size cable as earth continuity wire drawn in same conduit including taking down old unsv complete all as specified and directed by Engineer-in- charge Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade top of pipe with funnel & wiremesh, and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including taking down old eathing complete all as specified and directed by Engr-in-charge. Notes :- (i) Cost of GI wire upto 7.5m is included in this item. (ii) PCC 1:2:4, Excavation, earthwork is included in the quoted rate of this item. (iii) Cost of GI tubing upto 7.5m is included in the quoted rate of this item. (iv) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (v) Minimum weight of reinforcement for RCC cover shall be 1 KG.
S&F in repeir/replacement digital single phase energy meter 240 volts AC having LCD display tamper proof Displays various electrical parameters like electric consumption (Kwh), Voltage(V), Current(I), Power-factor(PF), Load (kw/kva), Frequency(Hz) on press of button and complete all as specified and directed by Engr-In-Charge.Make:- L&T,Havells,Secure Meters & other eqlt makes as per Appx.
Taking down old unsv LED Lights fittings and supply and fix new LED light fittings of following :-
(a) S&F in repair/replacement LED lights fitting 1x 18/20W, 220V, AC integrated decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-In-Charge.
(b) S&F in repair/replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-In-Charge.
(c) S&F in repair/replacement Bulk Head wall light fixture 9/10 Watt Environment Friendly Energy saving Edge Lit LED luminare of high brightness IP 65 Protection wall mounted, complete all as specified and as directed by Engineer-in-charge.
Dismentaling /Taking down Existing Meter box/Main Incoming Wall Mounted MCB Box,including electric connections and refixing the same after duly painted with two coats of aluminium paint over a coat of red oxide primer complete and proper fitting of doors and boxes with replaced hings, fixed dents, locks and seal gaps and including new connection to each meter with 10 sqmm copper conductor cable and including replacement of copper bus bar with proper insulation, with color coding complete all as specified and directed by Engr-In-Charge.Note:- MCB SPN , MCB TPN,MCCB and MCB SP paid under appropriate items saparetly.
Supply and fixing DB, double door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting SPN, 8 way, 230 Volt, with 200 Amp rated bus bar suitable for fixing MCBs, isolators etc including taking down old complete all as specified and directed by Engr-In-Charge.
(a) All as per sl item no. 43 here-in-before but 4 ways TPN DB 415 volts with 200Amp rated bus bar.
S&F in repair/replacement of below mentioned MCBs / MCCBs of following type and capacity as per directed by Engr-In-Charge:-
(a) S&F in repair/replacement MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
(b) S&F in repair/replacement MCB 40 - 63Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
(c) S&F in repair/replacement MCB 63 to 100 Amps, TPN 415 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
(d) S&F in repair/replacement of MCCB, 100 Amp, 4 Pole, 16KA, 415 volts with fixed thermal magnetic release complete all as specified and directed by Engineer-in-charge.
(e) S&F in repair/replacement of MCCB, 125 Amp,4 Pole,16KA, 415 volts with fixed thermal magnetic release complete all as specified and directed by Engineer-in-charge.
S&F in repair/replacement LED post top light fitting 40 watt, decorative design, glare free and better uniformity, complete fitting with all accessories and LED lamp, fixing on existing GI pipe system or as directed by Engineer-in-Charge including making electric connections complete fitting with all accessories and specifications and all as directed by Engr-in-Charge.
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections in and including where required PVC conduit 20 mm dia heavy duty ISI marked one twin core cable flat or circular 6 Sqmm etc including necessary fittings including taking down old unserviceable cable complete all as specified and as directed by Enigneer-in-Charge. Note : Excavation and earthwork shall be measured and paid seperately
Supplying, laying, jointing, commissioning and testing in replacement PVC insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 25 sq mm 4 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes including taking down old unsv etc complete all as specified and directed by Engineer-in-charge. Note : Excavation and earthwork, Brick protection and sand cushioning shall be measured and paid seperately
(a) All as per item No 48 above but cable of cross sectional area 16 sq mm 4 core.
(b) All as per item No 48 above but cable of cross sectional area 35 sq mm 4 core.
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in approved soft/loose soil including spreading, leveling, watering and well ramming in layers each n.exc 25cm complete all as specified and as directed by Engineer-in-Charge.
Removing surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed by Engineer-in-Charge.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge. Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, abutting each other with gap between adjacent bricks not exc. 10mm, length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
Supplying and laying for GI pipe light grade 40 mm bore (ISI marked) laid in trenches/ road crossings/ fixed to poles /walls/ path /drain/floors with and including all necessary clamps, nut bolts and washers etc all fitting as required including taking down old unsv pipe , complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully existing geyser of storage capacity of 25/50 ltr capacity for repair/replacement of following unserviceable parts :-.
(a) S & F in replacement heating element of capacity 1.5 KW including rubber washer , bolts , clamps etc for geysers of 25 Itr capacity of any type & make complete all as specified and as directed by Engineer - in - charge .
(b) S & F in replacement heating element of capacity 2 KW including rubber washer , bolts , clamps etc for geysers of 50 Itr capacity of any type & make complete all as specified and as directed by Engineer - in - charge .
(c) S & F in replacement thermostatic switch ( ISI marked ) of range 0 ° C to 80'C suitable for 25/50 ltr capacity geyser complete all as specified and as directed by Engineer - in - charge .
(d) S & F in replacement indicating lamp round / rectangular type as per existing suitable for 25/50 ltr capacity geysers working on 230 volt AC supply complete all as specified and as directed by Engineer - in - charge .
(e) S & F in replacement fusible safety brass plug as per existing suitable for 25/50 ltr capacity geysers complete all as specified and as directed by Engineer - in - charge .
(f) S & F in replacement 600mm long PVC connection set of two suitable for hot and cold water of 15 mm bore with PTMT nuts on both sides complete all as specified and directed by Engineer - in - charge .
(g) S&F in replacement plug top 3 pin,15 Amp, 230 volt AC complete all as specified and as directed by Engineer-in-charge .
Taking down existing Exhaust fan / Ceiling fan / wall mounted fan of any make and any size for repair/replacement of following unserviceable parts:-
(a) Supply and fix in repair/replacement ball bearing of required size for ceiling fan of size 1200/1400 mm sweep ISI marked complete all as specified and directed by Engineer-in-Charge.
(b) Suppy and fix in repair/replacement ball bearing of required size for Exhaust fan/wall fan of any size ISI marked complete all as specified and directed by Engineer-in-Charge.
(c) S&F in repair/replacement mild steel clamp assembly including steel nut bolt, split pin heavy duty suitable for ceiling fan of any make and size complete all as specified and directed by Engineer-in-Charge.
(d) S&F in repair/replacement capacitor of 4 mfd capacity, 230 Volts including provision of insulation sleeves ISI marked complete all as specified and directed by Engineer-in-Charge.
(e) S&F in repair/replacement capacitor of 3.15 mfd capacity, 230 Volts including provision of insulation sleeves ISI marked complete all as specified and directed by Engineer-in-Charge.
(f) S&F in repair/replacement capacitor of 2.5 mfd capacity, 230 Volts including provision of insulation sleeves ISI marked complete all as specified and directed by Engineer-in-Charge.
S.K BUILDERS AND ENGINEERS (BID ID -3228722)
SHIVA BUILDERS (BID ID -3229377)
godara construction company (BID ID -3218144)
SIGMA ENGINEERS AND CONTRACTORS (BID ID -3217885)
Bhavya Enterprises (BID ID -3217740)
BHADU BUILDERS (BID ID -3229307)
B.K. ROY & SONS (BID ID -3217496)
DASHMESH ENTERPRISES (BID ID -3222883)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .