Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC | ₹31.1 L Quoted ₹31.7 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹43.5 L+₹11.8 L (37.4%)Rejected-Finance | ₹43.5 L+₹11.8 L (37.4%) | L2 | Rejected-Finance Other than lowest |
| 3 | Rejected-Technical | - | - | Rejected-Technical bidder is not enlisted with cat |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
23 Oct 2024, 6:00 pmClosed
GE(AF) EM Chakeri Kanpur
GE(AF) EM Chakeri Kanpur
Cleaning of overhead tanks, UG Sumps, Static water tank and redevelopment of bore well including allied works at AFS Kanpur
2024_MES_676571_1
8726/E8
Open Tender
Civil Works
Item Rate
270 days
Area under GE(AF) EM Chakeri Kanpur
As per tender documents
9 documents required · 9 mandatory
₹500
GE(AF) EM Chakeri
₹80,000
Yes
22 Jan 2025
25 Sept 2024
28 Oct 2024
26 Sept 2024
23 Oct 2024
9 Oct 2024
Amount
Cleaning of internal surafces of RCC overhead tanks/ Reservoirs of 1,00,000 gallons capacity at 25 M height by using high pressure rotary jet machine and pumping out/ flushing out water, mud, sludge, dirt etc by any means of industrial vaccum cleaner including brooming down or steel wire brushing; scrapping down, moulds, moss and efflorescent salts and washing the inside surfaces including pipes, ladders etc. and treating the surfaces by spraying sodium hypochlorite (anti bacterial agent) in a concentration as directed by means of high pressure rotary jet machine & UV radiation disinfactant, disposing off the spoils to a distance not exceeding 50 M in a safe manner where , including mentioning details paint e.g date of cleaning of tank, next due date of cleaning of Tank with month and year to be mentioned, complete all as specified.
Cleaning of internal surafces of RCC overhead tanks/ Reservoirs of 70000 gallons capacity at 21 M height by using high pressure rotary jet machine and pumping out/ flushing out water, mud, sludge, dirt etc by any means of industrial vaccum cleaner including brooming down or steel wire brushing; scrapping down, moulds, moss and efflorescent salts and washing the inside surfaces including pipes, ladders etc. and treating the surfaces by spraying sodium hypochlorite (anti bacterial agent) in a concentration as directed by means of high pressure rotary jet machine & UV radiation disinfactant, disposing off the spoils to a distance not exceeding 50 M in a safe manner where , including mentioning details paint e.g date of cleaning of tank, next due date of cleaning of Tank with month and year to be mentioned, complete all as specified.
Cleaning of internal surafces of RCC overhead tanks/ Reservoirs of 50000 gallons capacity at 21 M height by using high pressure rotary jet machine and pumping out/ flushing out water, mud, sludge, dirt etc by any means of industrial vaccum cleaner including brooming down or steel wire brushing; scrapping down, moulds, moss and efflorescent salts and washing the inside surfaces including pipes, ladders etc. and treating the surfaces by spraying sodium hypochlorite (anti bacterial agent) in a concentration as directed by means of high pressure rotary jet machine & UV radiation disinfactant, disposing off the spoils to a distance not exceeding 50 M in a safe manner where , including mentioning details paint e.g date of cleaning of tank, next due date of cleaning of Tank with month and year to be mentioned, complete all as specified.
Cleaning of internal surafces of RCC overhead tanks/ Reservoirs of 20000 gallons capacity up to 21 M height by using high pressure rotary jet machine and pumping out/ flushing out water, mud, sludge, dirt etc by any means of industrial vaccum cleaner including brooming down or steel wire brushing; scrapping down, moulds, moss and efflorescent salts and washing the inside surfaces including pipes, ladders etc. and treating the surfaces by spraying sodium hypochlorite (anti bacterial agent) in a concentration as directed by means of high pressure rotary jet machine & UV radiation disinfactant, disposing off the spoils to a distance not exceeding 50 M in a safe manner where , including mentioning details paint e.g date of cleaning of tank, next due date of cleaning of Tank with month and year to be mentioned, complete all as specified. .
Cleaning of internal surafces of RCC overhead tanks/ Reservoirs of 10000 gallons capacity up to 25 M height by using high pressure rotary jet machine and pumping out/ flushing out water, mud, sludge, dirt etc by any means of industrial vaccum cleaner including brooming down or steel wire brushing; scrapping down, moulds, moss and efflorescent salts and washing the inside surfaces including pipes, ladders etc. and treating the surfaces by spraying sodium hypochlorite (anti bacterial agent) in a concentration as directed by means of high pressure rotary jet machine & UV radiation disinfactant, disposing off the spoils to a distance not exceeding 50 M in a safe manner where , including mentioning details paint e.g date of cleaning of tank, next due date of cleaning of Tank with month and year to be mentioned, complete all as specified. .
Cleaning of internal surafces of Underground sump/ Reservoirs of 200000 gallons capacity, by using high pressure rotary jet machine and pumping out/ flushing out water, mud, sludge, dirt etc by any means of industrial vaccum cleaner including brooming down or steel wire brushing; scrapping down, moulds, moss and efflorescent salts and washing the inside surfaces including pipes, ladders etc. and treating the surfaces by spraying sodium hypochlorite (anti bacterial agent) in a concentration as directed by means of high pressure rotary jet machine & UV radiation disinfactant, disposing off the spoils to a distance outside MOD land (1 KM range) in a safe manner where, including mentioning details paint e.g date of cleaning of tank, next due date of cleaning of Tank with month and year to be mentioned, complete all as specified.
Cleaning of internal surafces of Underground sump/ Reservoirs of 175000 gallons capacity, by using high pressure rotary jet machine and pumping out/ flushing out water, mud, sludge, dirt etc by any means of industrial vaccum cleaner including brooming down or steel wire brushing; scrapping down, moulds, moss and efflorescent salts and washing the inside surfaces including pipes, ladders etc. and treating the surfaces by spraying sodium hypochlorite (anti bacterial agent) in a concentration as directed by means of high pressure rotary jet machine & UV radiation disinfactant, disposing off the spoils to a distance outside MOD land in a safe manner where , including mentioning details paint e.g date of cleaning of tank, next due date of cleaning of Tank with month and year to be mentioned, complete all as specified. .
M&L for clening of underground static water tank of approx 25000gln capacity by mechanised de watering by using industrial submersible pump, scrapping sludge and removel by using industrial sludge pumping ,cleaning of all dust particle ,sterilization of tank by using chlorination chemical and two coat of whitewash on internal surfaces of wall including preperation of surfaces,including mentioning details paint e.g date of cleaning of tank, next due date of cleaning of Tank with month and year to be mentioned, complete all as specified. Note:- (a) Sludge shall be removed to a distance not exc 50 mtr distance and depositing where directed.(b) the cost of T&P and safty equipment shall be included in the quoted rates. (c) The contractor will responsible for all safty measure of workers.
M&L for clening of RCC underground sump of 20000 Gallon capacity in a fire pumphouse at 110 block inside by mechanised de watering by using industrial submersible pump, scrapping sludge and removel by using industrial sludge pumping ,cleaning of all dust particle ,sterilization of tank by using chlorination chemical and two coat of whitewash on internal surfaces of wall including preperation of surfaces,including mentioning details paint e.g date of cleaning of tank, next due date of cleaning of Tank with month and year to be mentioned, complete all as specified. .
Note for item no.1 to 9:- (i) Necessary Ladder/Sacafolding etc. as required shall be arranged by the contractor without any extra cost to Govt.
(ii) Necessary safety arrangement to the manower engauged by the contractor shall be provided by the contractor without any extra cost to Govt.
Collecting of Sampling of non chlorinated water from various pump houses under AOR of AGE E/M-II Chakeri as and when directed by Engineer-in-Charge and testing the water for bacteriogogical , Physical and chemical as per IS-1622 and 3025 from any Government/NABL approved laboratories and submission of test report to Engineer-in-Charge within 10 days of direction for testing complete all as directed by Engineer-in-Charge . Note:- Sampling shall be done by the authorised rep of the approved laboratory from whom the testing of water is to be carried out in presence of JE/Engr-in-charge).
Taking down existing wornout Flex Board and S&F of PVC sheet weighing 350gm/sqm flex duly fixed on a aluminium pipe frame work madeout of 40mmx40mmx2mm thick pipe by suitable means.Flex Board of size 900mmx1200mm fixed to walls with and including stainless steel nuts, bolts and washers duly printed (embossed) with the specifications of pump, including its year of commissioing, capacity, make, MES /Machine No., supplied areas, interconnection etc. in desired colour of water supply and allied connections of Pump house as per sample format provided by Engineer-in-charge complete all as specified.
Taking down of unserviceable /wornout LED aviation light fitting from OHT and S&F LED aviation obstruction light 7 watt luminaires , die cast aluminium alloy housing with red polycarbonate dome, integral driver, complete all as specified.
M & L for construction of valve chamber in replacement 1200 x 1200 x 1200 mm internal dimensions, 6 mm thick MS sheet cover with 2 Nos MS hinges welded to angle iron frame of 40x40x6 mm thick with lifting hook and locking arrangement complete with necessary earth work, brick work in CM (1:6), 230 mm thick, PCC bed (1:4:8) type D2 150 mm thick, cement plastering, finishing 15 mm thick in CM (1:4) and applying a coat of black bituminous paint to the steel surfaces incl dismantling and removal of old unserviceble valve pit remains all as specified and directed.
All as per item no 13 but of size 1000x1000x1000mm
All as per item no 13 but of size 900x900x900mm
All as per item no 13 but of size 600x600x600mm
Supply & fixing in replacement sluice valves 250 mm dia class PN-1.6 , IS-14846 with flanged ends, stainless steel spindle and iron wheel including nut bolts and rubber packing complete all as specified and directed by Engineer in Charge
All as per item no 17 but 200mm bore
All as per item no 17 but 150mm bore
All as per item No 17 but 100mm bore
All as per item No 17 but size 80mm bore
S& F in replacemnt Electronic microprocessor based digital & wire less type water level indicator with alarm at time of full level/Low level in tank including all eqpts accomodated in GI sheet box or completely enclosed complete including testing & Commissioning complete all as specified and as directed
Supply and fixing in replacement phase sequencer cum pump protection system 415/440 volts, 50 Hz, internal working voltage 12/14 volt, suitable for 50 HP with MNX 100 comtactor capacity load for auto change of phase sequence if incommimg phase sequence changes, single phasing prevention system and adjustable low and high voltage protection system to protect the machinery, mounting on bracket made out 40x3 mm angle iron frame, all control wirings, cable connections complete all as specified and as directed. Model No. MU-G 50 of L&T or as approved by GE
All as per item No 23 but suitale for 30 HP complete. Model No. MU-G 30 of L&T or as approved by GE
S & F in replacement fully automatic star delta starter suitable for 50 HP submerssible pump set including connecting all incoming and outgoing copper wire as directed
S & F in replacement fully automatic star delta starter suitable for 30 HP submerssible pump set including connecting all incoming and outgoing copper wire as directed
M&L for design, manufacture,supply,installation and comissioning LED display boards of following sizes having compact design,and maintenance friendly. The base of the board made of ACP(aluminium composite Panel) 3 mm thick and back side of board covered with GI sheet 24SWG, the letters and borders made of acrylic sheet 3 mm thick of colour as approved by Engineer-in-charge, LED module should as per requirement of letter space, the display language may be English/Hindi(Alpha numeric), its visibility should be suitable for day & Night (Outdoor application) and should be visible upto 25 M(minimum), the text effect should be static, the LED suitable for powe supply 230 volts/50 Hz, AC with switch ON and OFF the power supply to the display boards. The board shall be suitably braced on back side with angle iron 40mmx40mmx3mm and making good of disturbed surfaces as per original including necessary connection with 3 core coppper conductor cable 1.5 sqmm from LED display boards to ceiling rose complete all as specified and as directed.
(a) Rectangular board having max 40 letters or characters in English language letter or character size, height not exceeding 250 mm and back depth max 65 mm of suitable width. NOTE:- Angle iron 40mmx40mmx3mm including nuts, bolts and washers shall be measured and paid seperately under respective items as considered therein.
M&L for making Translite colour print LED panel for water supply site plan of pump house and OHT's or any other purpose including using clear acrylic sheet, blurr acrylic sheet of suitable thickness, clipon edge lit LED frame with using of high resolution LED complete with adopter and necessary fixing arrangements for making LED panel, wall mounted complete complete all as specified and as directed. NOTE:- (i) Water supply site plan kept at AGE E/M-II office.(ii) Letters or characters size shall be as directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, all as specified and directed
M&L for framed work such as grills,gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of Ladder in Over Head Tank and similar work con-forming to Fe 290.Gde-E-165 complete all as specified and directed.
M&L forapplying two coat of synthetic enamel paint over a coat of red oxide primer including preparation of newly steel surface of any description exc. 10 cm width or girth complete all as specified and directed
M&L for cement concrete 1:2:4 Type B 1 using 20 mm graded stone aggregate, for PCC work under over head tank and other water supply area, complete all as specified and as directed by Engineer- in -Charge.
S&F in replacement new generation IP-65 POST TOP 25 W, energy saving, environment friendly, long aesthetically designed with symmetrical light distribution spun aluminium landscape luminaire with high power LEDs as light source including fixing arrangement complete all as specified and as directed.
Cleaning of Pump house and all connected valve pits inside and outside and cleaning roof of building cutting of grass in side of boundery wall , surrounding of OHTs and complete remove the all waste materials approx area upto 500 sqm complete all as specified and directed. Note:- Min two cleaning of Pump House area shall be done, 1st cleaning shall be done just after commencment of work and 2nd cleaning shall be done just before completion of work. this shall be considered as one job ,so contractor shall quote their rate accordingly.
M&L for pouring of Sodium Meta Hexa Phosphate in the borewell complete all as specified and directed. Note:- Qty as braught by the contractor and remaining qty after pouring shall be recorded in MB.
M&L for lifting out submersible pumps set from bore well with column pipe steel rope, submersible cable including lowewring, commissioning testing the same after developing the borewell complete all as specified and directed.
M&L for development of bore well by Air Compressor capable to work at pressure gauge approx 300 to 500 PSI and capacity approx 1000 cfm continously, to clean the slots of the pipe and to explore the possiblity of recouping of well with natural water table including transportation, errection and dismantling of air compressor complete all as specified and directed.
M&L for development of bore well by over pumping to clean the slots of the pipe and to explore the possiblity of recouping of well with natural water table including transportation, errection and dismantling of air compressor complete all as specified and directed.
All as per item No. 38.00 above but for 24 hrs if required on the basis of out put results complete all as specified and directed.Note:- for item No 37, 38 & 39: Log sheet of compressor machine shall be maintained and signed by Contractor, JE, Engineer-in-Charge and GE.
M&L for testing of yield of well by means of 'V' notch, necessary T&P and equipments complete all as specified and directed.
Running of developed bore for 16 Hrs continous to check the potability of water after and including lowering the pump set of desired capacity complete all as specified and directed.
Supply & filling pea gravel for packing of size 3 to 5 mm to be designed by the contractor of natural shape brought direct from river bed and packing around the casing and slotted pipe in deep borewell all as directed by Engineer in Charge. Note:- For payment purpose 'P' gravels as braught by the contractor shall be recored in MB and after pouring P gravels in bore well, remaining qty shall also be recorded in MB.
S&F discharge head assembly 150 mm dia fixed with and including PCC 1:2:4 type B1 using 20 mm graded stone aggregate for and with provision of bolts for foundation etc complete all as specified and directed.
Supply & Fix in replacement MS nut bolt with washer of any size complete all as specified and directed.
S&F in replacement rubber packing flange 80 mm dia complete all as specified and directed.
S&F in replacement of rubber packing flange 100 mm dia complete all as specified and directed.
S&F in replacement of rubber packing flange 150 mm dia complete all as specified and directed.
M&L for providing water proof joint for submersible cable any size complete all as specified and directed.
S&F in replacement of electric cable submersible type flat 3 core 16 Sqmm stranded copper conductor PVC sheathed complete all as specified and directed. Note :- Old cable shall be deposited to MES store
All as per item No 49 above above but size 10 Sqmm 3 core.
Supply, installation, testing and commissioning in replacement of Submersible pump set electric driven, ISI marked, , pump with bronze impellars, CI casing, with ss shaft, leaded bronze bearings, / bushes , complete all as per IS- 8034 with copper wound submersible motor suitable for 415 Volts , 3 phase, 50 Hz supply of 40 HP, stain less steel tubing as per IS-9283 of 2013 ( suitable for 200 mm dia borewell ) with Head 90-110 mtrs and discharge 1400-1500 LPM, 6 stage complete including lifiting of existing submersible pump from borewell, removal of old pump set and fixing of new one all as directed by Engineer in Charge. Make- KSB or equivalent Note : Rate quoted by contractor shall deemed to be inclusive of lifiting of existing submersible pump from borewell, removal of old pump set and fixing of new one complete with cable joint water proff and relowering complete all as specified and directed by Engr-in-charge. Old Pump shall be deposited to MES store and same shall be taken on Ladger Book.
Supply & lowering in replacement MS column pipe 150mm dia in standard length of 3.00 m, heavy duty heavy grade ERW pipe, duly threaded at ends with provision of MS flange duly drilled and welded, supported with 4 nos welded MS flat strips at each flange complete all as specified and directed.
All as per item No. 52 above but 100 mm dia.
All as per item No. 52 above but 80 mm dia.
S&F 2.5 sqmm 3 core Copper Flexible Cable with suitable clamps complete all as specified and directed.
S&F in replacement MCCB FP, 415V, 100 Amps with breaking capacity 16 KA complete all as specified and directed.
S&F in replacement MCCB FP, 415V, 125 Amps with breaking capacity 25 KA complete all as specified and directed.
Preetpowercontrol (BID ID -3141321)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .