Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.3 LAccepted-Finance | 1 | Accepted-Finance Rates are resonable |
| Sl No | Description | Qty | Unit | M/s A.K. ELECTRICAL WORKS L1 |
|---|---|---|---|---|
| 1.01 | Replacement of faulty/burned H.T power cable with new 3x120 Sqmm Aluminium HT Cables, Stranded Compactedt Circular Aluminium Conductor, Conductor Screen with Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with Extruded Semi Conducting Compound in Combination with Copper Tape, Cores Laid Up,Innersheath of PVC, Galvanised Steel Flat Strip Armoured, & Overall PVC Sheathed Cable Conforming to IS 7098 (Part-2) (Havells/KEI/POLYCAB/GEMSCAB or S.S.-ISI make) | 115 | Mtr | 3,66,275 ₹4,32,204.5 Lowest |
| 1.02 | Loading unloading and transpotation of 3x120.0 Sqmm H.T. alluminium power cable from shop to TE compound at Shivpuruwa through minitruck with the help of crain/hydra and skilled manpower etc complete as required. | 1 | Job | 3,600 ₹4,248 Lowest |
| 1.03 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 120 sq. mm | 10 | Mtr | 6,000 ₹7,080 Lowest |
| 1.04 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 120 sq. mm | 15 | Mtr | 1,350 ₹1,593 Lowest |
| 1.05 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. Up to 120 sq. mm | 90 | Job | 6,120 ₹7,221.6 Lowest |
| 1.06 | Providing and making a spherical hole approx 3 feet deep in ground to keep the extra/loop power cable i/c protective covering, sand coushing, making good etc complete as required. | 2 | Job | 3,000 ₹3,540 Lowest |
| 1.07 | supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required 3x120 Sqmm | 1 | Job | 16,500 ₹19,470 Lowest |
| 1.08 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required 3x120 Sqmm | 1 | Job | 22,500 ₹26,550 Lowest |
| 1.09 | Providing and making arrangeent for cleaning of chocked existing CC duct ,clear and clean the duct in the way that the cable may be laid in this duct smoothly , etc complete as required.(Note--At present duct is full of RAW/Waste material) | 1 | Job | 3,000 ₹3,540 Lowest |
| 1.10 | Providing and making coordination/liosining with the UPPCL staff , providing support , cleaning of tree parts , for smooth connection of HT power cable on pole , taking shutdown,etc complete as required. | 1 | Job | 3,700 ₹4,366 Lowest |
Tender Value
₹5.1 L
EMD Value
₹10,159
Closing Date
18 Aug 2025, 4:00 pmClosed
Executive Engineer (E) B.S.N.L., Varanasi
O/o The Executive Engineer (Electrical) BSNL Electrical Division, 3rd Floor, Admin. Bldg., T.E. Compound Shivpurwa Varanasi
Replacement of Faulty/Burned H.T. Cable with new 3x120 Sqmm XLPE Aluminium Power Cable at main exchange Shivpurwa. (On Urgent Basis)
2025_BSNL_244085_1
05/NIT/BED/VNS/2025-26 Dated 05.08.2025
Open Tender
Electrical Works
Item Rate
15 days
TE Shivpuruwa Varanasi
Please refer tender document
2 documents required · 2 mandatory
₹590
ACCOUNTS OFFICER, (Cash), O/oGMTD, BSNL, Varanasi
₹10,159
30 Aug 2025
6 Aug 2025
20 Aug 2025
6 Aug 2025
18 Aug 2025
6 Aug 2025
Replacement of faulty/burned H.T power cable with new 3x120 Sqmm Aluminium HT Cables, Stranded Compactedt Circular Aluminium Conductor, Conductor Screen with Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with Extruded Semi Conducting Compound in Combination with Copper Tape, Cores Laid Up,Innersheath of PVC, Galvanised Steel Flat Strip Armoured, & Overall PVC Sheathed Cable Conforming to IS 7098 (Part-2) (Havells/KEI/POLYCAB/GEMSCAB or S.S.-ISI make)
Loading unloading and transpotation of 3x120.0 Sqmm H.T. alluminium power cable from shop to TE compound at Shivpuruwa through minitruck with the help of crain/hydra and skilled manpower etc complete as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 120 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 120 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. Up to 120 sq. mm
Providing and making a spherical hole approx 3 feet deep in ground to keep the extra/loop power cable i/c protective covering, sand coushing, making good etc complete as required.
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required 3x120 Sqmm
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required 3x120 Sqmm
Providing and making arrangeent for cleaning of chocked existing CC duct ,clear and clean the duct in the way that the cable may be laid in this duct smoothly , etc complete as required.(Note--At present duct is full of RAW/Waste material)
Providing and making coordination/liosining with the UPPCL staff , providing support , cleaning of tree parts , for smooth connection of HT power cable on pole , taking shutdown,etc complete as required.
Providing and making suitable size of M.S Plate of 1.5x2.5 feet, 3.0 mm thich with openable handle to cover the open area of the existing CC duct for protection of the power cable etc complete as required.
Supply and fixing of 4 inch dia PVC hume pipe , fixing on wall with the help of M.S. Clamp, suitable size of nut & bolts,for laying of cable inside this PVC pipe etc complete as required.
Provising and makking hole on the 9 inch wall to insert the HT power cble from outside to substation romm making good the damage with cement sand etc complete as required.
Providing and filling of sand (White) in the existing CC tranch after laying of cable etc complete as required.
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .