Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
16 Jul 2024, 6:00 pmClosed
GE (AF) Srinagar
Garrison Engineer (AF) Air Force Station Srinagar 190 007
REPAIR / MAINTENANCE OF SUMMER APPLIANCES, HOT WATER APPLIANCES (GEYSER) AND OTHER MISC E/M WORKS UNDER GE (AF) SRINAGAR
2024_MES_661768_1
GE (AF)/SGR-05/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE AF Srinagar
Please refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Srinagar
₹66,000
Yes
2 Sept 2024
24 Jun 2024
18 Jul 2024
24 Jun 2024
16 Jul 2024
9 Jul 2024
Amount
Taking down folloiwing fans of any type and size from site and removing to MES store for servicing like cleaning, lubricating, greasing and replacement of split pin, bearing, bush, capacitor, connection wire and refixing the fans at same location after spray painting to complete fan including blade by applying one coat of synthetic enamel paint and testing, complete all as specified and directed. Note :- (a) Contractor will provide one electrician and one helper for removing the faulty fan and refixing the serviced ceiling fan. (b) Contractor team will report to AGE E/M Sub Div daily except sunday and holiday at 0900 Hrs to collect ceiling fan complaints. (c) Contractor will give one year guarantee for repairable fan except burnt out fans). (d) Rate quoted by the contractor shall be deemed to be inclusive of spare parts as required.
Ceiling fans of any size any sweep
Exhaust fans of any size (metal body)
Exhaust fans of any size (PVC body)
Wall mounting/air circulator fan of any size and type
M&L for replacement of burnt out coil of copper and aluminium winded for following fans and rewinding complete with super enamelled copper wire of same guage and weight including replacement of bearing, bush, capacitor, insulation paper and varnishing including spray painting to complete fan including blade by applying one coat of synthetic enamel paint and testing complete including taking down, removal to workshop and refixing upto satisfaction of Engr-in-Charge. Note :- 1. Rewinding work shall be carried out at AGE E/M store yard or any place decided by Engineer-in-Charge. 2. Contractor is responsible to give one year guarantee for rewinding fans).
Ceiling fan 1200/1400 mm sweep working on 230 volts AC supply
Exhaust fan upto 600 mm sweep working on 230 volts AC supply (metal body)
Exhaust fan upto 400 mm sweep working on 230 volts AC supply (metal body)
Exhaust fans upto 300mm sweep working on 230 volts AC supply (PVC body)
Wall mounting/air circulator fan of any sweep working on 230 volts AC supply
S&F in repairs fan hanging hook any type or size suitable to hang on wooden block, MS bar etc with rubber reel, nuts, bolts, split pin etc suitable for ceiling fan, complete all as specified and as directed.
S&F in replacement down rod made out of GI pipe medium grade 15mm 40cm length dia with fan clamps including drilling, cutting threading & white painting etc for ceiling fans 1200/1400mm sweep, complete all as specified and directed.
S&F in repairs canopy for ceiling fans upper and bottom (Set of two), complete all as specified and directed.
S&F in replacement by cutting sizes water proof plywood ISI Marked, 12mm thick, of required size incl necessary provisions for mounting in walls, openings and securing using fasteners 10 cms long and 8 mm dia for mounting of exhaust fans in various locations and sizes, complete all as specified and directed.
Taking down old unserviceable PVC ventilation/exhaust fan after disconnecting the wire from ceiling rose and deposited to store yard of AGE E/M and supply and fix ventilation/exhaust fan made out of plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm, complete all as specified and directed.
Taking down old unserviceable PVC ventilation/exhaust fan after disconnecting the wire from ceiling rose and deposited to store yard of AGE E/M and supply and fix ventilation/exhaust fan made out of plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200 to 250 mm, complete all as specified and directed. (Note:- Size of fan shall be decided by the Engineer-in-Charge.)
Taking down old unserviceable ceiling fans after disconnecting the wire from ceiling rose and deposited to store yard of AGE E/M and supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE 5 star rated with brushless direct current motor (BLDC), complete all as specified and directed.
S&F in replacement stepped type , electronic fan regulator flush type on the existing phenolic laminated sheet etc.suitable for 1200 mm sweep ceiling fan, complete all as specified and directed.
S&F in replacement louver shutter of exhaust fan upto 400 mm size round or square as per site condition including fixing arrangement with fixing material, complete all as specifed and directed.
S&F in replacement terminal connector 3 way, complete all as specified and directed.
S&F in replacement capacitor 2.5 mfd 230 volts, complete all as specified and directed.
S&F in replacement capacitor3.5/ 4 mfd 230 volts, complete all as specified and directed.
S&F MS screw for fixing of ceiling fan blade of any size and type, complete all as specified and directed.
S&F in replacement of fan blade suitable for 1200mm dia ceiling fan, complete all as specified and directed. (Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells/ Polar make fans.)
S&F in replacement of fan blade suitable for 1400mm dia ceiling fan, complete all as specified and directed. (Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells/ Polar make fans.)
S&F in replacement of fan blade suitable for upto 300 mm dia PVC exhaust fan, complete all as specified and directed. (Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells/ Polar make fans.)
S&F in replacement of PVC fan blade suitable for wall mounted fan upto 400mm dia, complete all as specified and directed. Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells/ Polar make fans.
S&F in replacement of PVC fan blade suitable for wall mounted fan upto 600mm dia, complete all as specified and directed. Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells/ Polar make fans.
S&F in replacement of wall mounted fan blade guard of size upto 600 mm dia, complete all as specified and directed. Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells/ Polar make fans.
Taking down and refixing ceiling fan of any size after replacement of fan rod with anti suicide fan rod (12") white, MS pipe zinc plated, 19mm OD, 1.8+/-0.05mm thick, spring set grade 3 carbon steel material zinc plated, MSME tested for performance test and opening at impact load of 22 Kgf and above and spring hidden in the pipe will expand to about 1 mtr or more complete all as specified and directed.
S&F in replacement of 6 Amp Modular switch, complete all as specified and directed.
S&F in replacement of 6 Amp piano switch, complete all as specified and directed.
S&F in replacement PVC copper cable flexible 3 core round heavy duty of size 40/0.0076 suitable for fan connection of any capacity, complete all as specified and directed.
Supply only ball bearing of ceiling fan of size 1200/1400mm sweep exactly similar as existing in fan, complete all as specified and directed.
Supply only ball bearing of exhaust fan of size 300/400/450mm sweep exactly similar as existing in fan, complete all as specified and directed.
Supply only gun metal bush of ceiling fan of size 1200/1400mm sweep exactly similar as existing in fan, complete all as specified and directed.
Supply only gun metal bush exhaust fan of size 300/400/450mm sweep exactly similar as existing in fan, complete all as specified and directed.
Disconnecting & taking down unserviceable geyser of 25/50 litre capacity of any make from the wall and opening carefully including descaling the inner surface by scrapping, carrying out soldering/ brazing/gas welding to prevent the leakage, filling of glass wool & replacement of any other defective spares, including replacement of required number of stainless steel screws, nuts & bolts,assembling the the same after repair work and fixing in its orginal place, connecting to water mains and electric supply, testing after repairs, complete all as specified and as directed by Engineer-in-charge. Note :spare parts and glass wool shall be measured and paid separtaly under respective items of BOQ.
Supply only glass wool of good quality as approved for 25 litre capacity of geyser complete all as specified and as directed by Engineer-in-Charge.
All as per above Ser item No. 30.00 here-in-before but 50 litre capacity.
S&F in replacement of unserviceable Stain less steel inner tank of 25 liter capacity geysers of existing make & model including testing after assembling & fixed at site, complete all as specified and directed.
All as per above Ser item No. 33.00 here-in-before but 50 litre capacity.
Replacement of unserviceable heating element with new heating elements screw/or stud type ISI marked 1500 watt 230 volts AC single phase including necessary washer, screw, nuts bolts etc., complete all as specified and directed.
All as per Ser item No 35.00 here in before but 2000 watt ISI marked.
All as per Ser item No 35.00 here in before but 3000 watt 415 volts AC three phase ISI marked.
All as per Ser item No 35.00 here in before but 4000 watt 415 volts AC three phase ISI marked.
Replacement of unserviceable Geyser thermostat switch with new thermostat switch ISI marked 230 Volts 50 Hz AC of range 0-100, degree centigrade, adjustable between 70 to 100 degree centigrade with necessary washer, screws nut etc., complete all as specified and directed.
Replacement of unserviceable Geyser thermostat switch with new thermostat switch ISI marked 415 Volts(Three phase) AC of range 0-100, degree centigrade, adjustable between 70 to 100 degree centigrade with necessary washer, screws nut etc., complete all as specified and directed.
S&F in repairs 06/08 hole Assembly for water heater of cap 25 Ltr ISI Marked, complete all as specified and directed.
S&F in repairs 06/08 hole Assembly for water heater of cap 50 Ltr ISI Marked, complete all as specified and directed.
S&F in replacement of safety valve ISI marked for any make and capacity, complete all as specified and directed.
Replacement of unserviceable indicator lamp assy with new indicator lamp assy 230 volts square or round suitable for any type or make of Geyser including connecting, complete all as specified and directed.
Replacement of unserviceable 23 to 30 cm long ,10 mm bore C.P Connection with brass union, complete all as specified and directed.
S&F in replacement of unserviceable Gun metal non return valve ,15 mm bore, complete all as specified and directed.
Replacement of unserviceable 45 cm long , 15mm bore PVC connection pipe with brass union both ends fixed to GI Pipe, complete all as specified and directed.
Replacement of unserviceable Apparatus plate for Syphon Assy for 25 litre, complete all as specified and directed.
Replacement of unserviceable Apparatus plate for Syphon Assy 50 litre, complete all as specified and directed.
Replacement of bottom/top plates made out of MS sheet of 1mm thick made to shape of required size factory made complete fitted with machining screws duly painted with synthetic enamelled white paint, complete all as specified and directed.
S&F in repairs sheet metal enclosure with single pole and neutral with two pin and earth plug socket including 20Amp 240 Volt including MCB SP,20 Amp (C-series), complete all as specified and directed.
S&F in repairs metal clad industrial plug and socket 3 pole+ earth 415 Volts 40 Amp etc., complete all as specified and directed.
S&F in repairs MCB single pole 240 Volts ISI marked of capacity 25 Amps B series, complete all as specified and directed.
S&F in repairs MCB single pole and neutral 240 Volts ISI marked of capacity 40 to 63 Amps B series, complete all as specified and directed.
S&F in repairs switch socket combination 5 in 1 16 Amp flush type ISI marked 240 Volts, complete all as specified and directed.
S&F in repairs three pin plug top ISI marked 15/16 Amp suitable for 240 Volts 50Hz AC, complete all as specified and directed.
S&F in repairs socket outlet 2 in 1 5 pin 16 Amp Flush type ISI marked suitable for 240 Volts 50Hz AC, complete all as specified and directed.
S&F in repairs socket outlet 2 in 1 5 pin 16 Amp modular type ISI marked suitable for 240 Volts 50Hz AC, complete all as specified and directed.
S&F in repairs piano switch flush type single pole one way 16 Amps, ISI marked or 240 Volts 50Hz AC, complete all as specified and directed.
S&F in repairs Modular switch flush type single pole one way 16 Amps, ISI marked or 240 Volts 50Hz AC, complete all as specified and directed.
S&F in repairs PVC gang box with 2 in 1 5 pin 16 Amps switch socket combination, ISI marked or 240 Volts 50Hz AC, complete all as specified and directed.
S&F 1100 Volts grade heavy duty cable pvc insulated stranded aluminium conductor served with inner sheathing of pvc tape and used for cservice connections suspended by insulating hangers not more than 1 mtr apart of size 10 sqmm 2 core, complete all as specified and directed.
S&F in repairs of Rubber O ring /gaskit having suitable holes to suit the hole of base plate of geyser of 25 ltrs capacity, complete all as specified and directed.
S&F in repairs of Rubber O ring /gaskit having suitable holes to suit the hole of base plate of geyser of 50 ltrs capacity, complete all as specified and directed.
Preparation of surface of geyser of 25 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying synthetic enamel paint over a coat of red oxide primer with spray gun and writing the MES No with black paint, complete all as specified and directed.
Preparation of surface of geyser of 50 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying synthetic enamel paint over a coat of red oxide primer with spray gun and writing the MES No with black paint, complete all as specified and directed.
S&F heavy duty pin type fastner 4'' long (GI nuts and volts and washer of suitable sizes) suitable for any capacity of geyser as per site, complete all as specified and directed.
S&F in repairs storage type water heater 5 star rated 50 ltrs capacity vertical wall mounting type made out of CRCA sheet outer body, stainless steel storage tank, titanium enamalled heatinh element, thermostate , thermal cutout, glass wool, including 15mm 450 mm long pvc connnectons etc making necessary all electric and water connections with 2.5 sqmm 3 core copper, multistranded cable with top indiacator plug top 15 Amp from geyser connection to socket including hold fast for fixing of new geyser and writing the MES No and unserviceable geysers will be deposited in MES store yard etc., complete all as specified and directed.
S&F in repairs storage type water heater 5 star rated 25 ltrs capacity vertical wall mounting type made out of CRCA sheet outer body, stainless steel storage tank, titanium enamalled heatinh element, thermostate , thermal cutout, glass wool, including 15mm 450 mm long pvc connnectons etc making necessary all electric and water connections with 2.5 sqmm 3 core copper, multistranded cable with top indiacator plug top 15 Amp from geyser connection to socket including hold fast for fixing of new geyser and writing the MES No and unserviceable geysers will be deposited in MES store yard etc., complete all as specified and directed.
Cutting chasing in brick walls for GI tubing 15/20mm bore including making good with cement mortar 1:3, cutting not exceeding 10cm girth, complete all as specified and directed.
S&F in repairs for 15mm bore long shank stop valve cast copper alloy chromium plated, fancy type, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed, complete all as specified and directed.
S&F in repairs for 20mm bore stop valve cast copper alloy, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed, complete all as specified and directed.
S&F in repairs for 20mm bore stop valve cast copper alloy chromium plated, fancy type, long shank cup concealed high pressure with cutch or butterfly handle screwed both ends for iron pipe or union and fixed, complete all as specified and directed.
S&F in repairs for 15 mm bore stop valve cast copper alloy, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed, complete all as specified and directed.
S&F for 15mm bore steel water tubing, medium grade, galvanised with all fittings and fixture fixed & concealed in wall/ceiling or laid in floors including taking out unserviceable pipe, complete all as specified and directed.
S&F for 20mm bore steel water tubing, medium grade, galvanised with all fittings and fixture fixed & concealed in wall/ceiling or laid in floors including taking out unserviceable pipe, complete all as specified and directed.
S&F in replacement of unserviceable cable with flexible PVC insulated copper conductor cable 3 core of size 40/0.0076 for AC of any capacity, complete all as specified and directed.
S&F in repairs of outer body ISI marked cap 25 Ltr, complete all as specified and directed.
S&F in repairs of outer body ISI marked cap 50 Ltr, complete all as specified and directed.
M&L for point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 2.50 sqmm drawn in and including electrical grade PVC conduit/casing caping on surface of wall not less than 20mm dia/25mm width with IS 9537 (Part-III) 1983 marked medium grade on surface of wall/ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm pressed steel modular boxes sunk on wall for mounting of modular switches, switch sockets, fan regulator etc including modular cover with frame any size complete all as specified and making good disturbed surfaces for one power point controlled by one, one way switch, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly.
Deduction to be made from BOQ for Schedule 'A' Part-II (Credit Schedule from dismentling/taking down items) worth 1,57,803.00 during AOC. Note :- Tenderers shall not quote for this Schedule.
M/S UTA MOTORS
M/s Jaipal Associates
M/S LATIF AHMED MIR
M/S LUCKY BUILDERS
M/S A.R TANTRAY
M/s Bashir Enterprises
M/S M.Y Enterprises
M/s Bilal Construction
M/S GULAM AHMAD ABDUL SAMAD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .