Loading…
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹21.2 L
EMD Value
₹42,350
Closing Date
16 Nov 2026, 5:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Sumit Chopra
Municipal Council Fatehabad
Supply of street light 90 watt 120 watt and 150 watt from ward 1 to 13
2026_HRY_558851_1
20268486790E 4521 444F 9D2A 76353F27D050272ULB
Open Tender
Civil Works
Works
150 days
Fatehabad
1st time tender
2 documents required · 2 mandatory
₹1,000
₹42,350
Yes
5 Nov 2026
5 Nov 2026
17 Nov 2026
5 Nov 2026
16 Nov 2026
5 Nov 2026
5 Nov 2026 - 7 Nov 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | [23.28.19.4]Supplying, installation, Testing and Commissioning of Smart Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement ( ( 700ma), Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000- 4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP-66,IK-08, CRI )80 , under voltage and over voltage protection, EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 and (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
1. Control and monitor LED luminaries with bi directional control (Status, Fault, Alarm, dimming level, wattage, energy)
2. to measure voltage, current, power, power factor, apparent energy, active energy, operating hours.
3. Inbuilt ambient light sensor, motion sensor based on Passive Infra Red (PIR).
4. Wi-Fi LoRA/Zigbee/Power line with Ethernet network based IOT feature as per site requirement or engineer in charge.
5. should be controlled through auto/ manual
6. Programmable level of not less than 48 different light intensity settings,
7. Inbuilt repeater and relay signals function to other controllers 4. 90 Watt [Rate] | 365 | Each | 3,375 | ₹12,31,875 |
| 2 | [23.28.19.6]Supplying, installation, Testing and Commissioning of Smart Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement ( ( 700ma), Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000- 4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP-66,IK-08, CRI )80 , under voltage and over voltage protection, EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 and (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
1. Control and monitor LED luminaries with bi directional control (Status, Fault, Alarm, dimming level, wattage, energy)
2. to measure voltage, current, power, power factor, apparent energy, active energy, operating hours.
3. Inbuilt ambient light sensor, motion sensor based on Passive Infra Red (PIR).
4. Wi-Fi LoRA/Zigbee/Power line with Ethernet network based IOT feature as per site requirement or engineer in charge.
5. should be controlled through auto/ manual
6. Programmable level of not less than 48 different light intensity settings,
7. Inbuilt repeater and relay signals function to other controllers 6. 120 Watt [Rate] | 130 | Each | 3,580 | ₹4,65,400 |
| 3 | [23.28.19.7]Supplying, installation, Testing and Commissioning of Smart Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement ( ( 700ma), Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000- 4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP-66,IK-08, CRI )80 , under voltage and over voltage protection, EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 and (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
1. Control and monitor LED luminaries with bi directional control (Status, Fault, Alarm, dimming level, wattage, energy)
2. to measure voltage, current, power, power factor, apparent energy, active energy, operating hours.
3. Inbuilt ambient light sensor, motion sensor based on Passive Infra Red (PIR).
4. Wi-Fi LoRA/Zigbee/Power line with Ethernet network based IOT feature as per site requirement or engineer in charge.
5. should be controlled through auto/ manual
6. Programmable level of not less than 48 different light intensity settings,
7. Inbuilt repeater and relay signals function to other controllers 7. 150 Watt [Rate] | 100 | Each | 4,200 | ₹4,20,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
BOQ_638863.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .