| Sl No | Description | Qty | Unit | THE BRIGHT ASSOCIATES | Vyankatesh Pharma | Ag Sales and Service |
|---|---|---|---|---|---|---|
| 1.00Supply Of Hysteroscopic Instruments | ||||||
| 1.01 | Diagnostic Hysteroscope-
- Feature Specification
- Outer Diameter 2.7 Mm
- Working Length 250 Mm – 300 Mm
- Angle Of View: 30°
- Field Of View Wide-Angle (≥80°)
- Image Transmission Rod Lens System (Preferred), Or Fiberoptic
- Sheath Size 3.5 Mm (Outer Sheath)
- Distension Media Normal Saline Or Co₂ (Based On System Compatibility)
- Light Source Connection Standard Fiber Optic Light Post (Compatible With Xenon Or Led Sources)
- Port Type Luer Lock Inflow Port (Optional Outflow Depending On Model)
- Sterilization Autoclavable Or Low-Temperature Plasma Sterilization
- Material Surgical-Grade Stainless Steel And Medical-Grade Polymers | 1 | No. | 2,57,250 ₹2.7 L | 2,74,400 ₹2.9 L | 2,99,700 ₹3.1 L |
| 1.02 | Operative Hysteroscope (4 Mm)
- Telescope Diameter 4.0 Mm
- Working Length 270–300 Mm
- Outer Sheath Diameter 5.5 Mm (Depending On Continuous Flow Or Single-Flow Sheath)
- Working Channels 1 Or 2 Channels, Standard 5 Fr (1.7 Mm) Instruments
- Angle Of View 30° (Standard)
- Field Of View Wide-Angle, Distortion-Free
- Image System Rod Lens Optical System, Hd-Compatible
- Sheath Type Continuous Flow (Inflow And Outflow Channels)
- Material Surgical-Grade Stainless Steel
- Light Transmission Fiber Optic Light Post, Universal Connector
- Distension Media Compatibility Normal Saline (For Bipolar Energy) Or Non-Electrolyte Fluid (For Monopolar)
- Electrosurgical Compatibility Bipolar Or Monopolar Electrodes (Rollerball, Loop, Hook, Etc.)
- Electrode Type Supported 5 Fr Electrodes – Resectoscope Type
- Instrument Compatibility Operative Scissors, Graspers, Biopsy Forceps (5 Fr)
- Sterilization Autoclavable (134°C) Or Low-Temperature Plasma Sterilization | 1 | No. | 2,57,250 ₹2.7 L | 2,79,000 ₹2.9 L | 2,99,700 ₹3.0 L |
| 1.03 | Hysteroscopic Resectoscope
Sheath & Telescope
Outer Diameter: 4.0 Mm Working Channel: 1.5–2.0 Mm (For Scissors, Biopsy Forceps, Graspers, Bipolar Electrodes)
Angle Of View: 30° Length: ~25–30 Cm
Fibre Optic Light Transmission With High-Resolution Rod Lens System
Resectoscope System (If Using With Loop / Rollerball)
Available As Mini-Resectoscope (4.0 Mm)
Compatible With Bipolar Energy Source
Working Element: Spring-Loaded Resectoscope With 4 Mm Telescope
Electrodes: Loop, Rollerball, Knife, Needle (Bipolar Compatible)
Fluid Management
Compatible With Saline (0.9%) As Distension Medium (For Bipolar)
Continuous Flow Sheath For Clear Vision
Inflow/Outflow Channels For Pressure-Controlled Irrigation
Other Features
Autoclavable Stainless Steel
Ergonomic Design For Operative Stability
Compatible With Standard Hd Camera And Light Source Systems | 1 | No. | 3,67,500 ₹3.9 L | 3,92,000 ₹4.1 L | 4,10,560 ₹4.3 L |
| 1.04 | Hysteroscopic Scissors
Size: 5 Fr (~1.7 Mm), 30–36 Cm
Passes Through Working Channel Of 4 Mm Hysteroscope.
Types: Straight / Curved / Angled
Material: Stainless Steel, Autoclavable | 2 | Nos. | 10,290 ₹10,804.50 | 12,000 ₹12,600 | 17,000 ₹17,850 |
| 1.05 | Hysteroscopic Biopsy Forceps
Size: 5 Fr (~1.7 Mm), 30–36 Cm Long.
Fits Into Working Channel Of 4 Mm Operative Hysteroscope.
Types: Biopsy (Punch), Grasping, Scissors.
Jaws: Serrated, Single/Double Action, Rotatable.
Reusable (Autoclavable). | 2 | Nos. | 10,290 ₹10,804.50 | 12,000 ₹12,600 | 17,000 ₹17,850 |
| 1.06 | Hysteroscopic Morcellator
System Components
Handpiece With Cutting Blade (Rotating/Reciprocating)
Inner Cutting Tube (Sharp-Edged) Inside Outer Sheath
Continuous Suction Attached → Simultaneous Cutting + Tissue Removal
Compatible Hysteroscope Sheath
Dimensions
Sheath Outer Diameter: 6–7 Mm (Mini Systems Available With 5 Mm)
Working Channel: 3–3.5 Mm (For Morcellator Blade)
Blade Sizes: 2.5–3 Mm (Straight Or Side-Facing Cutting Window)
Length: 26–30 Cm
Optics
0° Or 12° Telescope, 2.9–4 Mm Rod Lens
High-Definition Fibre-Optic Illumination
Energy / Working Principle
Mechanical Cutting
Continuous Suction For Clear Vision And Specimen Collection
Works With Normal Saline As Distension Medium | 1 | No. | 36,96,000 ₹38.8 L | 39,42,000 ₹41.4 L | 42,59,000 ₹44.7 L |
| 1.07 | Hysteromat – Fluid Management System
Specifications
Medium Used: Co₂ (Rarely Now) Or, Preferably, Fluids (Normal Saline, Glycine, Mannitol, Sorbitol).
Pressure Range: Adjustable, Usually 30–150 Mmhg.
Flow Rate: 50–500 Ml/Min (Depending On Model).
Display: Digital Display For Set Pressure, Actual Pressure, Inflow, Outflow, And Fluid Deficit.
Safety: Audible Alarms For Excessive Pressure Or Fluid Deficit (To Prevent Overload/Turp Syndrome).
Tubing Set: Disposable Dual Line Tubing (Inflow + Outflow). | 1 | No. | 4,99,800 ₹5.2 L | 5,33,000 ₹5.6 L | 5,17,600 ₹5.4 L |
Tender Value
Refer Docs
EMD Value
₹14,000
Closing Date
3 Jan 2026, 5:00 pmClosed
DEAN, MGIMS
Mahatma Gandhi Institute of Medical Sciences Sevagram, Wardha 442102, Maharashtra, India
Supply Of Hysteroscopic Instruments
2025_MGIMS_881717_2
eTender/2025-26/CPS/056
Open Tender
Equipments (Hospital / Lab)
365 days
MGIMS, SEVAGRAM
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹14,000
Yes
19 Jan 2026
18 Dec 2025
5 Jan 2026
18 Dec 2025
3 Jan 2026
18 Dec 2025
18 Dec 2025 - 28 Dec 2025
Supply Of Hysteroscopic Instruments
Diagnostic Hysteroscope- - Feature Specification - Outer Diameter 2.7 Mm - Working Length 250 Mm – 300 Mm - Angle Of View: 30° - Field Of View Wide-Angle (≥80°) - Image Transmission Rod Lens System (Preferred), Or Fiberoptic - Sheath Size 3.5 Mm (Outer Sheath) - Distension Media Normal Saline Or Co₂ (Based On System Compatibility) - Light Source Connection Standard Fiber Optic Light Post (Compatible With Xenon Or Led Sources) - Port Type Luer Lock Inflow Port (Optional Outflow Depending On Model) - Sterilization Autoclavable Or Low-Temperature Plasma Sterilization - Material Surgical-Grade Stainless Steel And Medical-Grade Polymers
Operative Hysteroscope (4 Mm) - Telescope Diameter 4.0 Mm - Working Length 270–300 Mm - Outer Sheath Diameter 5.5 Mm (Depending On Continuous Flow Or Single-Flow Sheath) - Working Channels 1 Or 2 Channels, Standard 5 Fr (1.7 Mm) Instruments - Angle Of View 30° (Standard) - Field Of View Wide-Angle, Distortion-Free - Image System Rod Lens Optical System, Hd-Compatible - Sheath Type Continuous Flow (Inflow And Outflow Channels) - Material Surgical-Grade Stainless Steel - Light Transmission Fiber Optic Light Post, Universal Connector - Distension Media Compatibility Normal Saline (For Bipolar Energy) Or Non-Electrolyte Fluid (For Monopolar) - Electrosurgical Compatibility Bipolar Or Monopolar Electrodes (Rollerball, Loop, Hook, Etc.) - Electrode Type Supported 5 Fr Electrodes – Resectoscope Type - Instrument Compatibility Operative Scissors, Graspers, Biopsy Forceps (5 Fr) - Sterilization Autoclavable (134°C) Or Low-Temperature Plasma Sterilization
Hysteroscopic Resectoscope Sheath & Telescope Outer Diameter: 4.0 Mm Working Channel: 1.5–2.0 Mm (For Scissors, Biopsy Forceps, Graspers, Bipolar Electrodes) Angle Of View: 30° Length: ~25–30 Cm Fibre Optic Light Transmission With High-Resolution Rod Lens System Resectoscope System (If Using With Loop / Rollerball) Available As Mini-Resectoscope (4.0 Mm) Compatible With Bipolar Energy Source Working Element: Spring-Loaded Resectoscope With 4 Mm Telescope Electrodes: Loop, Rollerball, Knife, Needle (Bipolar Compatible) Fluid Management Compatible With Saline (0.9%) As Distension Medium (For Bipolar) Continuous Flow Sheath For Clear Vision Inflow/Outflow Channels For Pressure-Controlled Irrigation Other Features Autoclavable Stainless Steel Ergonomic Design For Operative Stability Compatible With Standard Hd Camera And Light Source Systems
Hysteroscopic Scissors Size: 5 Fr (~1.7 Mm), 30–36 Cm Passes Through Working Channel Of 4 Mm Hysteroscope. Types: Straight / Curved / Angled Material: Stainless Steel, Autoclavable
Hysteroscopic Biopsy Forceps Size: 5 Fr (~1.7 Mm), 30–36 Cm Long. Fits Into Working Channel Of 4 Mm Operative Hysteroscope. Types: Biopsy (Punch), Grasping, Scissors. Jaws: Serrated, Single/Double Action, Rotatable. Reusable (Autoclavable).
Hysteroscopic Morcellator System Components Handpiece With Cutting Blade (Rotating/Reciprocating) Inner Cutting Tube (Sharp-Edged) Inside Outer Sheath Continuous Suction Attached → Simultaneous Cutting + Tissue Removal Compatible Hysteroscope Sheath Dimensions Sheath Outer Diameter: 6–7 Mm (Mini Systems Available With 5 Mm) Working Channel: 3–3.5 Mm (For Morcellator Blade) Blade Sizes: 2.5–3 Mm (Straight Or Side-Facing Cutting Window) Length: 26–30 Cm Optics 0° Or 12° Telescope, 2.9–4 Mm Rod Lens High-Definition Fibre-Optic Illumination Energy / Working Principle Mechanical Cutting Continuous Suction For Clear Vision And Specimen Collection Works With Normal Saline As Distension Medium
Hysteromat – Fluid Management System Specifications Medium Used: Co₂ (Rarely Now) Or, Preferably, Fluids (Normal Saline, Glycine, Mannitol, Sorbitol). Pressure Range: Adjustable, Usually 30–150 Mmhg. Flow Rate: 50–500 Ml/Min (Depending On Model). Display: Digital Display For Set Pressure, Actual Pressure, Inflow, Outflow, And Fluid Deficit. Safety: Audible Alarms For Excessive Pressure Or Fluid Deficit (To Prevent Overload/Turp Syndrome). Tubing Set: Disposable Dual Line Tubing (Inflow + Outflow).
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.83 MB
NIT056.pdf
Tender Documents • 0.82 MB
BOQ_935904.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid