Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹40.8 L+₹2.4 L (6.26%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L2 | Rejected-Finance Being not lowest tenderer | |
| 3 | L3₹49.9 L+₹11.5 L (29.9%)Rejected-Finance | L3 | Rejected-Finance Being not lowest tenderer |
Tender Value
₹40.9 L
EMD Value
₹81,800
Closing Date
31 Jul 2023, 6:00 pmClosed
CWE AF TUGHLAKABAD
AF STATION, TUGHLAKABAD PO SANGAM VIHAR NEWDELHI-110080
PROVN OF SHED FOR SOLID WASTE MANAGEMENTS (SWM) AT AF STN SEKHON VIHAR UNDER GE (AF) GURGAON NO.1
2023_MES_606587_1
CWE/TKD/GUR/TOKEN-31 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Gurgaon No.1
As per NIT conditions
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON NO.1
₹81,800
Yes
7 Sept 2023
28 Jun 2023
2 Aug 2023
28 Jun 2023
31 Jul 2023
12 Jul 2023
Amount
Sch 'A' Part-II ((Earth Work and Demolition)
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete al as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft loose soil complete al as specified and directed.
Removing excavated material exc 5.00Km and n exc.15.0 Km and depositing where directed at a level n exc. 1.5 m above the starting point complete al as specified and directed.
Returning, filling in, incl spreading,levelling, watering and well ramming in layers n. exc 25 cm. In soft/loose soil complete all as specified and directed.
Sch 'A' Part-I (Bldg B/R works)
Supply and Fixing of Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses Electric resistance or induction butt welded tubes etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
S & F MS Plates, holding down bolts nuts, bolts washers screws of any size and sections etc, plates comlete all as directed
Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Preparation of new steel surfaces and applying two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed.
Fixing only chainlink fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed.
Supply only chain link MS galvanised fencing of 4 mm dia, size 50x50mm complete all as specified and as directed.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete all as specified and as directed.
M & L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and dia of neck 5 to 10 mm complete all as specified and as directed.
M & L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,exc 22.50cm n exc 30 cm long and dia of neck 15 to 20 mm complete all as specified and as directed.
M & L brick work with sub class 'B' bricks(old size bricks) straight or curved on plan exc 6 m mean radius built in cm 1 : 6 with and including weep holes in brick work complete all as specified and directed.
M & L rendering 15 mm thick on fair faces of brick work /concrete surfaces, finishing even and smooth without using extra cement in cement mortar 1 : 4 complete all as specified.
M & L for two coats of cement paint inciuding preparation of new plastered surfaces of walls complete all as specified and directed .
M&L PCC 1:2:4 type B1 using 20mm graded stone aggregate as in foundation filling kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, all as specified and as directed.
M&L 75 mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection complete all as specified and as directed.
M & L Hardcore of broken stone of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M & L PCC 1:4:8 type D-2(using 40mm graded stone aggregate) as in foundation sub base, filling and mass concrete complete all as specified and as directed.
M&L for 100mm thick Cement concrete type B- 1, 1:2:4 (40mm graded stone aggregate) including finished even and smooth without using extra cement complete all as specified and as directed.
M & L Reinforced cement concrete M-25 (design mix) for columns, etc. using 20mm graded stone aggregate complete in all respect as specified and directed.
M & L Reinforced cement concrete M-25 (design mix) for RCC Foundations, including rafts, footings, foundation beams plinth beams; bases for columns, etc. basement slabs, under-reamed piles and mass concrete using 20mm graded stone aggregate complete in all respect as specified and directed.
M&L mild steel TMT bars 10mm dia and over cut to length , bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia bars confirming to Fe-410-S or Fe-410-0 complete in all respect as specified and directed.
M&L mild steel TMT bars 5mm dia and over up to 10mm for stirrups cut to length , bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia bars confirming to Fe-410-S or Fe-410-0 complete in all respect as specified and directed.
M & L for rough finished concrete Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete in all respect as specified and directed.
M & L for rough finished concrete Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter complete all as specified and as directed.
M & L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified Note- (Payment for providing grooves shall be made separately under respective item of BOQ).
Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge :
Sch 'A' Part-II (Bldg E/M works )
M & L for point wiring (concealed on wall & surface/concealed on cealing) for one light/fan/exhaust fan controlled by one modular/piano switch one way in different locations/building including rigid non metallic PVC conduit, medium grade, ISI marked , 20 mm dia, with 1.5 sqmm FRLS PVC insulated & unsheathed, stranded copper conductor of 1.5 sqmm as continuous earth connected to common earth dolly, complete all as specified and directed by Engr-in-charge.
All as per item No 2.01 above but for 5 Amps 5 Pin socket outlet on the same board complete all as specified and as directed.
All as per item No 2.01 above but one 5 pin, 5 Amp socket outlet on independent board not below the switch board of the light point in the same vertical plane complete all as specified and as directed.
-Ditto- as per item No. 2.01 above but point wiring with 2.5 Sqmm cable and 2.5 Sqmm earth continuity conductor for 3 pin 15 Amp socket complete all as specified and directed.
S& F ceiling rose, 2 to 3 terminals complete all as specified and as directed .
S&F Modular switch, one way 6 Amps , 1 module as specified.
S&F Modular Socket , 6 A-2/3 Pin combined 2 module all as specified and directed.
S&F twin socket modular type heavy duty outlet 6 pin 6/16 Amps 2 module, complete all as specified and as directed.
S&F switch Modular type 16 Amps , single pole one way 240 volts one module as specified.
M&L for metal flush box for fixing of switches for 3 module complete all as specified and as directed.
M&L for metal flush box for fixing of switches for 8 module complete all as specified and as directed.
Supply & fix Modular White cover plate with frame for 3 module complete all as specified and as directed.
Supply & fix Modular White cover plate with frame for 8 module complete all as specified and as directed.
Supply and fix PVC ventilating fan AC single phase 230/240 volts of size 200 mm sweep with louvers and connecting up including provision of cable from ceiling rose to connector to exhaust fan also making of suitable size hole on wall/window as per site requirement and make the disturbed surface good with existing treatment complete all as specified and as directed.
S&F Double door distribution board 240 Volts 8 way with 200 amps rated bus bar complete all as specified and as directed.
S & F MCB SP of rating, 06 to 32 Amp,240 volt, 10 KA 'B' Series type complete all as specified and as directed.
S & F MCB SPN of rating 40 Amp, 240 Volt, 10 KA, 'B' series type complete all as specified and as directed.
S & F MCB TPN of rating 63 Amp, 415 Volt, 10 KA, 'C' series type complete all as specified and as directed.
M&L for sub main wiring of two run with 04 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC casing-n-coping/conduit pipe as per site requirement medium grade ISI marked and accessories of suitable size and fixed on wall/ceiling including one run of 4.0 Sqmm single core PVC insulated, FRLS , flexible copper cable as earth continuity conductor in green color all as specified and as directed.
S&F in replacement of 4 ft 18/20 watt Decorative ultra slim aluminium LED lighting fixture with high lumen output, environmental friendly, energy complete all as specified and by Engr-in-charge.
S&F in replacement of 2 feet 09 W slim LED battern (cool day light) Basic all purpose surface and wall mounted with polycarbonate housing & integrated with electronic driver complete all as specified and as directed.
Supply & fix sheet metal enclosure for 220 volts 20 Amps with a three pin and earth plug top with socket and one single pole MCB 20 amps complete as well as specified and directed.
Supply & fix Solution with Insulated Plug & Socket sheet metal enclosure for 415 volts 63 Amps MCB with 3P+N+E complete as well as specified and directed.
Supply and fixing 30 watt LED street light fitting including with suitable size mounting bracket complete all as specified and directed.
Supply & fix 1200 mm sweep ceiling fan 5 star rated power consumption 6 W (lowest speed) 35 W (highest speed); Speed 370 RPM; Air delivery 220 CMM; Operating voltage 90 V - 300 V complete all as specified and directed.
Supply & fixing heavy duty exhaust fan AC single phase 230/ 240 V AC of size 300 mm sweep 4 blade and having 1400 RPM with suitable size of louvers complete all as specified and directed.
Sch 'A' Part-III (Road Path works)
Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in soft and loose soil complete all as specified and directed.
Rolling and consolidation formation surfaces of road/herms in curring with 8 to 12 filling tonnes power road roller complete to rolled and consolidated to required gradient and camber as necessary and filling in hollows and depressions which may occur during the process of rolling all as specified and as directed by the Engineer in charge
M&L for stone soling with crushed stone interstices filled surface formed and rolled and consolidated to required gradiant and camber 150 mm special thickness complete all as specified and directed
M&L for 150 mm thick (compacted thickness WBM in two layers 75 mm thick with coarse aggregated of grading 2 (63 to 40 mm) granite trap or blast crushed stone spread and camber required complete all as specified and directed
Preparing surface of un-surfaced water bound mecdam by brushing with wire brushes for removing cracked mud etc sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc and applying evenly a priming/ tack coat with and including bituminous primer (paving biumen ) at the rate of 10 kg per 10 square meter of road surface and providing and M&L for bituminous premixed semi donse asphalted concrete 40 mm consolidated thickness using paving bitumen of grade [email protected]% binder coment by weight of total mix spread by means of self propelled mechanical spread/ pavers rolled and campacted to required camber and gradiant by using mechanical power road roller 8 to 10 ton capacity complete all as specified and as directed.
M&L Hard core of gauge not exceeding 63 mm deposited spread and levelled in layers not exc 15 cm thick watered and rammed to a true surface complete all as specified and directed.
M&L for PCC (1:4:8) Type D-2 (using 40mm graded stone sggregate ) as in filling/sub base to floors etc complete all as specified and directed
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS15658-2006 of 80mm thickness M-40 grade with grey cement and pigment over and including 30 mm thick sand cushioning complete all as specified and directed.
M&L for PCC (1:2:4) Type B-1 (using 20mm graded stone sggregate ) as in cills, steps, bands etc complete all as specified and directed
M&L for precast cement concrete block of PCC 1:2:4 type B 1 using 20 mm graded stone aggregate for road side kerb stones set and jointed in cement mortar 1:4 complete all as specified and directed.
Removing excavated material exc 1.50Km and n exc. 5.0K m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Sch 'A' Part-IV (External Electric Supply )
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4.0 core complete all as specified and directed.
Demolition of concrete any description in ground/floor /paving not exc. 15 cm thickness ( below or above ground level) complete all as specified and directed.
M & L PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundation of pole complete all as specified and directed.
M & L PCC 1:3:6 type C1 using 20 mm graded stone aggregate in coping of pole including necessary form work complete all as specified and directed.
Supply and fixing GI pipe Light grade 50 mm bore (ISI marked) laid in trenches/ path /road crossings/ fixed to poles/ceiling/ along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, complete all as specified and as directed by the Engineer-in-Charge. (Note:- Necessary excavation and earth work shall be measured and paid for separately)
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick electrode, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to 4 mm dia galvanized earth wire by means of bolts, nuts, check-nuts and washers of galvanized iron or steel all as shown in electrical plate No 5 (duly protected with 15 mm dia light grade GI pipe upto 7.5m from the earth plate) and connected to GI steel earth plate including charcoal, dust, common salt, necessary excavation in soft/loose soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m from the starting point, watering pipe 20 mm bore GI tube of light grade treated with 1 No PGI funnel, pit of PCC 1:2:4 type B-1/ RCC 1:2:4 type B-1, pit cover 75 mm thick reinforced with 6 mm dia bars @ 75 mm c/c both ways and with MS handle 12 mm dia connected to earth test point including testing complete all as specified and directed.
S&F Sheet metal enclosure suitable for fixing of FP 63 Amps MCCB with breaking capacity 25 KA complete all as specified and directed.
M&L for excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc. and getting out soft/ loose soil complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layer not exceeding 25cm complete all as specified and directed.
Removing excavated materials not exceeding 50 mtrs away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply and laying clean dry sand for cable cushioning including gently punning down complete all as specified and directed..
M&L for old size , burnt brick, sub class 'B', laid in trenches, abutting each other with a gap not exceeding 10 mm , vertically over the cable for cable protection complete all as specified and directed.
Sch 'A' Part-V (Sewage Disposal)
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft loose soil complete all as specified and directed.
Removing excavated material exc 5.00Km and n exc.15.0 Km and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Concrete bed to drain pipes of 150 mm dia with cement conrete 1:3:6 type C2 using 20mm graded stone aggregate including packing under, and hunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M&L for RCC drain pipes class NP3 With collors 150 mm dia laid in trenches and joints as specifiedcomplete all as specified and directed.
M&L for cement concrete 1:3:6 type C2 ( 40mm graded stone aggregate) as in sub base and mass concrete all as specified and as directed.
M& L for Providing cement concrete type B-1 1:2:4 in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating,complete all as specified and directed.
M& L for Brick work with sub-class `B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed.
M & L rendering 15 mm thick on fair faces of brick work /concrete surfaces, finishing even and smooth without using extra cement in cement mortar 1 : 3 complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
Providing precast cement concrete type B-1 1:2:4 in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed.
M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required placing in position and binding with MS wire not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
akhil enterprises
tarun construction co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .