Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC NABA MISHRA COLONY HATATOTA TALCHER DIST ANGUL PIN 759100 | TALCHER | ANGUL | ODISHA | 759100 | L1 | Accepted-AOC TECHNOCOMMERCIALLY ELIGIBLE L1 BIDDER | |
| 2 | Rejected-Technical AT DEULBERA PO TALCHER DIST ANGUL PIN 759100 | ANUGUL | ODISHA | 759100 | - | Rejected-Technical REJECTED FOR NOT BEING L1 | |
| 3 | Rejected-Technical AT FCI LAXMI BAZAR TALCHER PO VIKRAMPUR DIST ANGUL ODISHA 759117 | TALCHER | ANGUL | ODISHA | 759117 | - | Rejected-Technical REJECTED FOR NOT BEING L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical REJECTED FOR NOT BEING L1 | |
| 5 | Rejected-Technical KAMALA BIHAR BAGHUABOL PO HATATOTA TALCHER DIST ANGUL ODISHA PIN 759100 | ANUGUL | ODISHA | 759100 | - | Rejected-Technical REJECTED FOR NOT BEING L1 |
Tender Value
₹37.3 L
EMD Value
₹46,700
Closing Date
26 Jun 2024, 5:00 pmClosed
Staff Officer(EnM), Jagannath Area, MCL
Jay Prakash, Staff Officer(EnM), Jagannath Area, MCL PH 06760-269717, 06670-269751(Extn)2023 Fax 06760-269527 E-mail so-enm-jaga.mcl(at)coalindia.in
Electrical wiring and rewiring at different locations of mine and office establishments as and when required at Bhubaneswari OCP for a period of 730 days.
2024_MCL_310515_1
GM(JA)/EnM/e-Tender/24-25 /E-665/30 dtd. 14/06/24
Open Tender
Electrical and Maintenance Works
Item Rate
730 days
TALCHER
AS PER NIT
4 documents required · 4 mandatory
₹46,700
21 Aug 2024
14 Jun 2024
28 Jun 2024
15 Jun 2024
26 Jun 2024
15 Jun 2024
15 Jun 2024 - 19 Jun 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc. as required.Group A
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required (2 X 2.5 sq. mm + 1 X 2.5 sq. mm )
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required(2 X 4 sq. mm + 1 X 4 sq. mm)
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required(4 X 6 sq. mm + 2 X 6 sq. mm )
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required (1 X 1.5 sq. mm )
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or recesses with suitable size with phenolic laminated sheet cover in front including providing and fixing 5 pin 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plays to be used in non residential buildings).
Supplying & fixing angle holder including connection etc as required.
Supplying & fixing 3 pin, 5 Amps ceiling rose on the existing junction box/wooden block including connection etc. as required.
Supplying and fixing following piano type switch/ socket on the existing switch box/cover including connections etc. as required.5/6 amps switch
Supplying and fixing following piano type switch/ socket on the existing switch box/cover including connections etc. as required.3 pin 5/6 A socket outlet
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 poles and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way(4 + 24), Double door
Supplying and fixing following rating, double pole, (single phase and neutral), 240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63Amp
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage,connection, testing, commissioning etc. as required.Upto 450 mm sweep
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MOB DB complete with connections, testing and commissioning etc. as required. 40Amps
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A,36KA,FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 250 A,36KA,FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 400 A,50KA,FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 800 A, 50 KA,TPMCCB
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63A TP&N
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 100 A TP&N
Providing and Erection of Metal Oxide lighting arrester copper
Supplying and fixing DP sheet steel enclosure on surface/ recess along with surge protection device 240 Volts 1 ph-N complete with connections, testing and commissioning etc. as required
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Providing of 20 watt Ceilling light
Providing and fixing of garden light fittings 20W
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
J.N. RAY
M/s. Sahida Electrical Works
HBS ASSOCIATES
M/S MAA ELECTRICALS
TARENI ELECTRICALS
PRADEEP KUMAR BEHERA
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .