Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹26.5 L
EMD Value
₹66,365
Closing Date
23 Feb 2025, 10:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Directorate of Municipal Administration
Asha
Providing HT infra to existing water works installation as a alternative source in case of emergency only (from 11kV supply of M/s NMDC Ltd) at Taranagara village in Sandur town limit
DMA/2024-25/EL/WORK_INDENT35979
DMA/2024-25/EL/WORK_INDENT35979
Open
Electrical
Two Tender Document System(Two Cover)
DMA Town Municipal Council Sanduru
4 documents required · 4 mandatory
To qualify for award of this contract, each tenderer in its name should have in the last five years i.e.2019-2020 to 2023-24 mandating satisfactory completed as a prime contractor for at least one similar work to an extent of Rs.13.28 Lakhs
KPWD Electrical Licence, GESCOM Registered Conctractor Registration certificater
To qualify for award of this contract each tenderer in its name should have in the last five years (2019-20 to 2023-24) Achieved in at least two financial years an average annual financial turnover in all classes of civil engineering construction works only of Rs.26.54 Lakhs
Liquid assets and or availability of credit facilities of not less than Rs.7.97 Lakhs in the form of Credit lines or Letters of Credit or Certificates from Banks for meeting the fund requirement Conditional bankers certificate not acceptable
N-A
N-A
N-A
N-A
N-A
N-A
N-A
N-A
₹670
₹66,365
12 Feb 2025
12 Feb 2025
24 Feb 2025
19 Feb 2025
Providing HT infra to existing water works installation as a alternative source in case of emergency only (from 11kV supply of M/s NMDC Ltd) at Taranagara village in Sandur town limit
200105-RCC Pole 9.0M Long,145 kg WL
278811-11kv Danger board
278911- Barbed wire 10 mts.
27901205-11 kV Horizontal cross arm wit
2791002-DP Structure with 9 Mtrs RCC P
279130-EG Stirrups (MS)
2811101-Guy with Complete set
281683-Spiral Earth Electrode
283008-11kV, 5KN Composite/Polymeric
283320-Silcon rubber composite insula
284108-Rabbit ACSR Conductor
285508-Rabbit to Rabbit (P G Clamps)
287405-11kV 3 Core XLPE UG Cable-240S
288304-3X240 Sq.mm (Heat Shrinkable o
288334- 3X240 Sq.mm (Heat Shrinkable
302340-RMU (3 way), One In comer + On
303200-L.A. 9kV, 5kA, Metal Oxide
800650-River sand
278811-11kv Danger board
278911- Barbed wire (10 mts.)
27911104-9 Mtr RCC DP Transformer Strct
2798001-Fish plate with necessary clam
281008-8 SWG G.I.Wire
281110-7/10 SWG Guy Wire
2811101-Guy with Complete set
2811103-Earthing Materials Type for gr
283008-11kV, 5KN Composite/Polymeric
283320-Silcon rubber composite insula
284503-LT Spacer for TC Wiring
285565-240Sq.mm (P.G. Clamps Rabbit t
288536-240 Sq.mm Copper terminals (Lo
301056-LT Distribution Box for 250 KV
302011-11 kV D.O.L.O Cutouts Convent Set/3 nos.
303200-L.A. 9kV, 5kA, Metal Oxide
304212-11kV G.O.S 200A Single break
3214400-250kVA, Aluminium Wdg, BEE 4 S
357510-L.T. Electronic Tri-Vector Met
358071-With CT ratio 400/5 for 250 kV
82193003-AL lead wire- 240sqmm
287218-400 Sq. mm 3.5 Core (Armoured
288166-3.5 x 400/500 sq. mm Epoxy Ter
358352-LT metering Cubicle at low ten
Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials
Erection of RCC/PSC poles 9 to 10 mtr long but in a pit of 1.8 mtr depth
Fixing Danger Board
G.I. Barbed Wire (12 mtrs/1kg)
Fixing of V- Shape/Horizontal cross arm including single top support Braces and Insulators fixing.
Same as above using RCC poles 9 mtr to 10 mtr long
Fixing of Earth Guard Stirrup
Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)
providing spiral earth electrode type earthing along with pole (without charcoal, salt etc.,)
For Rabbit ACSR
3x185 to 240 sq.mm
UG Cable Works FOR Earth work excavation for cable trench of 0.5 to 0.75 mtr In Ordinary Soil
3x185 to 3x240 sq.mm
3x185 to 3x240 sq.mm
Fixing of 3 Nos lightning arrestors including wiring.
Soil classification has to be certified by the concerned Executive Engineer Elc. Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in...
Fixing Danger Board
G.I. Barbed Wire (12 mtrs/1kg)
Erection of pole 100 to 250 kVA with 9 mtrs. RCC pole
Wiring of One circuit of LT Wiring Kit for for 25/63/100 KVA DTC to
the existing LT protection Kit Kit / Distribution Box via metering box.
Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)
Providing GI Pipe Earthing for lightning arresters Transformer Neutral and Transformer Metal parts (Excluding digging of pits)
Fixing LT Distribution box for 100/ 250 / 500 KVA
DTCs (Excluding wiring)
Fixing DOLO cutouts / Horn Gap Fuses including fixing of cross arms and wiring
Fixing of 3 Nos lightning arrestors including wiring.
Fixing of GOS including wiring (11kV SB 200A)
Erection of 200-250 kVA Transformer on Transformer structure.
LT Electroic Tri-Vector Meter 5A, Class-0.5/1.0 Accuracy
LT Metering Box For Housing ETV Meter with CT
3x185 to 240 sq.mm
Erection of LT metering cubicle on platform
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
KW2_21.30 L gescom.doc
Tender Document • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .