Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical REJECTED |
| 4 | Rejected-Technical | Rejected-Technical REJECTED |
| 5 | Rejected-Technical | Rejected-Technical REJECTED |
Tender Value
₹24.8 L
EMD Value
₹50,000
Closing Date
19 May 2021, 5:00 pmClosed
Arun Bhatia
Executive Engineer, Provl. Divn. No.2, Hr. PWD B and R Br., Kurukshetra.
Construction of Washu Judo Hall Dronacharya Stadium at Kurukshetra
2021_HRY_169696_2
PWD/AMB/KKR-2/110139
Open Tender
Construction Works
Works
90 days
Kurukshetra
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹50,000
16 Jun 2021
11 May 2021
20 May 2021
11 May 2021
19 May 2021
11 May 2021
Amount
Dismantling Brick Work, TileMasonry or Tile Lining and Tile Terracing in cement.(HSR 8.5) (b)
Dismantling Concrete cement concrete plain 1:2: 4 mix (HSR-8.6) (d)
Dismantling Roofing demolishing mud phaska in tile terracing (HSR-8.8) (g)
Rebarring 25mm dia bar hole size 30 mm dia & depth upto 300 mm (HSR B1882) (a) Coloumn C1, C2 25mmQ & Coloumn C3', C3 25mmQ
Rebarring 16 mm dia bar hole size 20 mm dia & depth upto 160 mm (HSR B1880) (b) Coloumn C3', C3 16mmQ
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size forreinforced concrete work for walls exceeding 20cm thickness (straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centering and shuttering, laid in position, complete in all respects.HSR 10.86. (a) Second Storey (i) Height up to 4 Metre
(b) Third Storey
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in well kerbs excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects. (HSR 10.92 + 10.95)(a) (a)Slab
(b)Stair
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in fascias parapets and other thin vertical sections, not covered by Item Nos. 10.82, 10.86 to 10.88 not exceeding 10 cm thickness excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects.(HSR 10.89 + 10.95)
Fe-500 EQR TMT steel bar for RCC work, where not included in the complete rate of RCC including bending, binding & placing in the position complete. (Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. From the length so measured, the weight of reinforcement shall be calculated in tones on the basis of IS:1732.Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing, shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement). (NS).
First class brickwork laid in cement sand mortar 1:6 in first storey upto 4 meters above plinth level.(HSR 11.7)
15 mm thick cement plaster 1:6 on the rough side of single or half brick wall (HSR 15.12).
12 mm thick cement plaster 1:6(HSR 15.7).
10 mm thick ceiling cement plaster 1:4(HSR 15.52).
Terracing consisting of tiles 22.86 cm X 11.43 cm X 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and on other layer of mud mortar for laying the tiles, including two coasts of bitumen laid hot at 1.65 Kg per sqm on top of R.C.C. slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc.(HSR 13.13).
Cement pointing 1:2 flush on flat brick flooring (HSR 15.71).
Cement concrete 1:2:4 gola 10cm X 10cm quadrant along junction of roof with parapet wall finished smooth, where specially specified.(HSR 13.64).
Top khurra 0.6 m x 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50 mm thick cement concrete 1:8:16 ( HSR 13.50).
Screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping. (HSR 14.4).
Kotah stone flooring minimum 25 mm thick in any pattern as specified over 20 mm thick base of cement coarse sand mortar 1:3 laid and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing.(HSR 14.62).
Kotah stone 20 mm thick in skirting risers of steps, dados and wall facing (lining) and pillars laid on 12 mm thick cement coarse sand plaster 1:3 laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing including labour for fixing cramps, dowels and pins etc.(HSR 14.66).
Providing & fixing PVC Rain water pipe 6Kg. Pressure of ISI mark in cement mortar during masonry work. 150 MM dia PVC pipe 6 Kg. Pressure.(HSR 13.89) (b).
Providing & fixing PVC Bend ISI Mark (b) 150 mm dia PVC Bend .(HSR 13.90) (b).
Pressed steel sheet frames (chowkats), consisting of 2 mm thick steel sheet of the specified section, including iron lugs (hold fasts), iron hinges, conforming to P.W.D. specifications, including bolts for fixing stops, lock notch, provision for receiving tower bolts, and finished with one coat of ready-mixed paint red lead non-setting primer, of approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame, and cement concrete 1:3:6 for lugs complete: -(c) door and window frame size 127 mm X 50 mm with 40 mm wide double rebate.(HSR 18.34) (c).
Factory manufactured panelled door or glazed window, shutters of commercial hard wood, such as hollock, champ,chikrassy and chaplash,etc.,(non-coniferous timber other than teak,conforming to I.S.specification No.1003,kiln-seasoned),with 100 mm wide verticle styles, 150 mm wide lock rail, 200 mm wide bottom rail and 100 mm wide other rails, with panels of15 mm thick, tongued and grooved of commercial hard wood and including cost of iron hinges,screws,chocks/cleats,stops,nails etc., complete,fixed in position (excluding the cost of any fittings,other than specified above,but including labour for fixing the same in position).(HSR 17.90) (c) 40 mm thick
Factory manufactured panelled and glazed door shutters of commercial hard wood, such as hollock, champ, chikrassy and chaplash,etc.,(non-coniferous timber other than teak,conforming to I.S.specification No.1003, kiln-seasoned),with 100 mm wide verticle styles, 150 mm wide lock rail, 200 mm wide bottom rail and 100 mm wide other rails, with panels of 12 mm thick commercial veneered both sides particle board or plywood of B.W.R. grade, hot-presses, including cost of iron hinges,screws,chocks/cleats,stops, and nails etc., complete,fixed in position (excluding the cost of any fittings,other than specified above,but including labour for fixing the same in position).(HSR 17.91) (c)
Factory manufactured wire gauze door and window shutters of commercial hard wood suchas hollock, champ, chikrassy and chaplash,etc.,(non-coniferous timber other teak, conforming to I.S.specification No.1003, kiln-seasoned),with 100 mm wide vertical styles, 150 mm wide lock rail, 200 mm wide bottom rail, and wire gauze of 140G or 120G designation including cost of iron hinges, screws,chocks/cleats,stops nail etc.,complete fixed in position (excluding the cost of any fitings,other than specified above,but including labour for fixing the same in position)-(HSR 17.92) (ii).
Wrought iron and mild steel (using angles, flats, square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors open able or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position.(HSR 18.12).
Scraping white wash and colour wash.(HSR 8.32) (a)
Providing and applying two coats white cement based putty over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete (JK/Birla Make)(HSR 16.81).
Distempering with washable oil bound\ Distemper (of approved manufacture) two coats over one priming coat on new work.(HSR 16.58).
Finishing walls with exterior decorative cement based paints such as snowcem, Robbiacem etc. on new work, two coats to give an even shade. (HSR 16.61)
Finishing walls with exterior decorative cement based paints such as snowcem, Robbiacem etc. on old work, one coat to give an even shade.(HSR 16.62).
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete(HSR 16.1).
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade.(HSR 16.3).
Note: In case of any difference in the unit & nomenclature of any of the HSR items depicted in this DNIT and that given in HSR, the unit and nomenclature given in HSR shall be applicable.
Aggarsain Coop L C Society
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .