Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.1 LAccepted-AOC 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹56.5 L+₹7.2 L (14.5%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹64.7 L+₹15.4 L (31.2%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L3 | Rejected-Finance Other than being lowest |
Tender Value
₹95 L
EMD Value
₹1.7 L
Closing Date
2 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
MANNING AND OPERATION FOR MARINE MAINTENANCE TEAM AT VARIOUS JETTIES AND CONNECTED ITEMS AT NAVAL DOCKYARD UNDER GE (NW) KUNJALI, COLABA, MUMBAI
2024_MES_668561_2
8353/CWE (NW) Mumbai/E8
Open Tender
Civil Works
Item Rate
330 days
GE (NW) Kunjali
Class C
category d (v)
7 documents required · 7 mandatory
₹1,000
GE (NW) Kunjali
₹1.7 L
Yes
22 Apr 2025
14 Oct 2024
4 Nov 2024
14 Oct 2024
2 Nov 2024
21 Oct 2024
14 Oct 2024 - 20 Oct 2024
Amount
Manning and operation including attending breakdowns of HT/LT network at various jetties, including cassions sub stations 6.6 KV/433 volts with 6.6 KV incoming from MRSS/INSS sub station and consisting of various sub stations and frequency convertor , transformers, HT/LT breakers, LT capacitor bank, battery chargers, LT panels, APFC panels, COPE points, distribution panels, including internal lighting/ventilation of the sub stations and manning duty round the clock in three shifts by skilled operator having minimum 3 years experince in electrical, mechanical and external electrification, carrying out manning duties by deploying the under mentioned manpower in three shifts including Sundays and Holidays complete all as specified and directed by the Engr- in- charge:- Electrician- Skilled -06 Electricians per day in 03 shifts (2 x 3= 6). Shift timings above are as under:- (a) First shift : 0600 hr to 1400 hr (b) Second shift : 1400 hr to 2200 hr (c) Third shift : 2200 hr to 0600 hr Rate shall be quoted for 06 Nos electricians
Manning and operation including attending breakdowns of HT/LT network at various jetties , including sub stations 6.6 KV/433 volts with 6.6 KV incoming from MRSS/INSS sub station and consisting of various sub stations and frequency convertor , transformers, HT/LT breakers, LT capacitor bank, battery chargers, LT panels, APFC panels, COPE points, distribution panels, including internal lighting/ventilation of the sub stations and manning duty round the clock in three shifts by skilled operator having minimum 3 years experince in electrical, mechanical and external electrification. carrying out manning duties by deploying the under mentioned manpower in three shifts including Sundays and Holidays complete all as specified and directed by the Engr- in- charge:- Mate electrician - Semi- Skilled- 12 Mate electricians per day in 3 shifts (4 x 3 = 12) Notes :- (i) Mate electrician must have passed matriculation with minimum two years experience in the trade. Shift timings of above are as under:- (a) First shift : 0600 hr to 1400 hr (b) Second shift : 1400 hr to 2200 hr (c) Third shift : 2200 hr to 0600 hr Rate shall be quoted for 12 Nos Mate electricians
NOTE FOR ITEM NO.1 & 2 : The duty for each shift at various substations are located inside Naval Dockyard area as directed by Engineer -in-Charge.
Manning and operation including attending breakdowns of water supply installation / sewage pump house at various water supply installations/sewage pump house at Naval Dockyard are as under : 1. CASSION No.1 & No.2 at SBW Jetty. 2. SOUTH WHARF pump house. Fresh water supply line incoming from BMC, sewage line to BMC main sewage pipeline and various other installations,and manning duty in two shifts by skilled operator having minimum 3 years experince in FGM/ pump opeartion. carrying out manning duties by deploying the under mentioned manpower in two shifts including Sundays and Holidays complete all as specified and directed by the Engr- in- charge:- FGM - Skilled - 2 FGM per day in 2 shifts (01 x 02 =2) Shift timings shall be as under:- (a) First shift : 0600 hr to 1400 hr (b) Second shift : 1400 hr to 2200 hr Rate shall be quoted for 02 Nos FGMs
Notes for item no 1.00 to 3.00- i) The cost of employment of supervisior and any assitance required to operate and maintain the installations by operating staff shall deemed to be included in above offer. ii) Each shift shall be of continuous 8 hours durations. As per industrial act one person should not be continued on duty for more than 06 days and he should be given weekly off day for his personal maintenance and one reliver should be employed for off duty by arrangement of contractor without any extra cost to the Govt.The rate quoted includes Oustourcing for operation & maintenance of installation on all days including Sundays/Gazetted Holidays. iii) The cost of maintenance of documents installations charts and daily records as clarified under relevant particular specifications shall deemed to be included in the rates quoted above. iv) The location of sunstations to be outsourced are lying inside restricted area and therefore the contractor/operating staff shall comply to all security measures/ restrictions imposed by the unit from time to time.
(v) The quoted rate deemed to be inclusive for provision of reliever duty and leave periods (vi) The operator on duty should have proper uniform in light blue colour shirt and dark blue trouser duly printed name as MES and contractor with all protective arrangement during the duties like shoes etc and required tools for operation and maintenance of installation.The rate quoted shall deemed to be inclusive of minor servicing like greasing of bearings, replacment of glands/ rubber coupling, belts etc.Periodical cleaning of cooling tower and AHU filters is contractors responsibility. (vii) The installation will be handed over in operating state on the commencement of contract though work order. (viii) Antecedents of the Personnel engaged by the contractor to carry out the work shall be verified from police authorities and accordingly security passes shall be issued. (ix) The contractor shall be solely responsible for all personnel deployed for carrying out the above jobs and all transport required for conveyance. The rate quoted shall deemed to be inclusive of EPF etc all as per latest norms of labour Commissioner.
x). The labourers shall be provided with protective devices and shall wear them while working. In case any accident/ injury/ fatal or partial disability happened, the contractor shall be solely responsible for settling all claims/ compensation. Department will have a right to recover any sum indicated/ claimed by Labour Commissioner/ Court directive. (xi) Contractor will render a certificate/ confirmation every month that minimum wages act is not violated and every employee engaged have been paid their wages only through individual bank account in full and receipts there on obtained. (xii) In case the absence of operator, GE shall impose penalty of Rs 500/- per hour.
(xiii) The bidders are advised not to quote rates less than minimum fair wages as circulated by competent authority . If the quoted amount is less than the estimated cost given at SCH A Note at Page No 14 the lowest bidder will have to depost FDR/BGB as elaborated herein after in favour of Accepting Officer within 07 days of opening of financial bid (cover No 2). (xiv) The deposited amount shall be the difference between estimated cost given at SCH A Note at Page No 14 and amount quoted by lowest bidder for respective item. FDR/BGB shall be released only after satisfactory completion of work. If the contractor fails to pay minimum wages to employees, the department shall have right to withhold the said amount which will be verified by GE. The decision of Accepting Officer regarding amont to be withheld shall be final and binding. The withheld amount will be utilised by GE for payment to employees if contractor fails to pay minimum wages and balance amount if any shall only be released. If the lowest bidder fails to deposit the amount as stated above within 07 days, the contractor shall be banned for 06 months & his bid shall be rejected. The contractor shall submit 03 Nos of BGBs/FDRs of equal amount as mentioned above. The BGBs/FDRs validity shall be 04 months, 08 month & 12 months respectively for the purpose of encashment release as the case may be.
Supply and fixing JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 25 mm dia with 250 micron ( average ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly shall be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF Powerfill Loresco compound shall be supplied in 50 Pound Bag. ( 1 Bag of 50 Pounds required per earthing set). Back-fill compound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set complete all as specified and directed by the Engr- in- charge Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
Supply & Fixing MCCB, 415 volts, four pole of capacity 1250 Amps, 50 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as specified and directed by the Engr- in- charge
Supply & Fixing MCCB, 415 volts, four pole of capacity 800 Amps, 36 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as specified and directed by the Engr- in- charge
Supply & Fixing MCCB, 415 volts, four pole of capacity 400 Amps, 36 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as specified and directed by the Engr- in- charge
Supply & Fixing MCCB, 415 volts, four pole of capacity 250 Amps, 50 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as specified and directed by the Engr- in- charge
Supply & Fixing Drawout version ACB, 415 volts, four pole of capacity 2500 Amps, 50 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as specified and directed by the Engr- in- charge
Shree Ayyappa Engineering (BID ID -3150827)
AGRAWAL ASSOCIATES (BID ID -3147379)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .