Sh Nitesh Verma DGM C&M Powergrid Corporation of India Ltd Western Region Transmission System II Regional Head Quarter Plot No 54 Adjacent to Riya Revati Resort Opp Ambe Vidyalaya Sama Savli Road Vadodara 390008 Mobile No 91 6264002998 Alternate No 91 9904754872
Establishment of new 220/33 kV, 2x50 MVA Substation at Solar PV Plant Nagda
WR2/NT/W-AIS/DOM/G01/23/01672
Open
Supply, errection and Commissioning
Works
Solar PV Plant Nagda
₹25,000
20 Apr 2023
20 Apr 2023
11 May 2023
20 Apr 2023
10 May 2023
20 Apr 2023
250kVA, 33/0.433kV, 3ph Transformer
245KV, 1600A, 40KA, 3PH CIRCUIT BREAKER
245KV, 1600A, 40KA,1-PH, CT-120% RATING
245KV, 4400PF, 1PH CVT
245KV, 1600A, 40KA, 3PH DB ISOLATOR+1E/S
245KV, 1600A, 40KA, 3PH DB ISOLATOR+2E/S
245kV,1600A,40KA 3PH DB ISOLATOR(TANDEM)
245kV,1600A,40KA 3PH DB ISOLATOR without E/S
SURGE ARRESTER,1-PH,216KV
245KV, 1PH BUST POST INSULATOR (BPI)
ERECTION H/W-220KV DM & BYPASS BUS COUPLER BAY
ERECTION H/W-220KV DM& BYPASS T/F BAY
ERECTION H/W-220KV DM& BYPASS LINE BAY
ERECTION H/W-220KV DM7 BYPASS BUS WORK-3 BAYS
36MM MS ROD(KM)
220KV BUS BAR PROTECTION PANEL-SAS
220KV TRANSFORMER PROTECTION PANEL-SAS
220KV LINE PROTECTION PANEL-SAS
220KV CB RELAY PANEL W/O A/R-SAS
220KV CB RELAY PANEL WITH A/R-SAS
220KV S/S AUTOMATION SYSTEM-MAIN BAY
S/S AUTOMATION SYSTEM FOR AUXILIARY SYSTEM
220V DCDB
415V AIRCONDITIONING DB
415V ELDB-25KVA LIGHTING TRAFO
415V MLDB WITH 25KVA LIGHTING TRAFO
415V ACDB
415V MAIN SWITCHBOARD
220V, 300 AH BATTERY
220V, 60A/60A BATTERY CHARGER
100 KVA DG SET
33KV, 3CX95 SQMM XLPE AL ARMOURED CABLE
CABLE TERMINATION KIT FOR 33KV 3CX95 SQMM XLPE AL ARMOURED CABLE
CABLE TERMINATION KIT FOR 33KV 3CX95 SQMM XLPE AL ARMOURED CABLE
1.1KV PVC CONTROL CABLE
1.1KV PVC POWER CABLE
1.1KV XLPE POWER CABLE
HIGH WALL TYPE SPLIT AC-2 TR
FIRE EXTIN.-DCP TYPE 4.5/5 KG PORTABLE
FIRE EXTINGUISHER-CO2 TYPE 4.5KG
FIRE EXTINGUISHER-WATER TYPE 9L
FIRE DETECTION & ALARM SYST-CRB-220KV
NITROGEN INJECTION FIRE PROTECTION-220KV
LIGHTING PANEL TYPE ACP-2
LIGHTING PANEL TYPE DCP
15A,240V,2POLE,3PIN O/D RECEPTACLE (RO)
63A, 415V O/D RECEPTACLE (RP)
250A O/D RECEPTACLE FOR OIL FILTERATION
LIGHTING FIXTURE LED TYPE FL2
CONTROL ROOM BUILDING ILLUMINATION-220KV
STD LM (50M)
STD 220KV GANTRY B1
STD 220KV TOWER CA
STD 220KV TOWER CB
STD 220KV TOWER CC
STD 220KV TOWER CD
STD 220KV TOWER CTC
STD 220KV TOWER CTH
PIPE STRUCTURE-220KV HIGH BPI (EXCL WT)
STD PIPE STRUCTURE - 220KV 1PH BPI
STD PIPE STRUCTURE - 220KV 1 PH CT
STD PIPE STRUCTURE - 220KV 1 PH HCT
STD PIPE STRUCTURE - 220KV 1PH CVT
STD PIPE STRUCTURE - 220KV 3PH ISOLATOR
STD PIPE STRUCTURE - 220KV 1PH SA
FOUNDATION BOLTS - 28MM DIA
FOUNDATION BOLTS - 40MM DIA
FOUNDATION BOLTS - 56MM DIA
BASE EQUIPMENT STM-16 MADM UPTO 5 MSP
E1 INTERFACE (MIN 16 NOS.)
ETHERNET L2 INTERFACE 10/100MBPS(MIN 8)
GIGABIT ETHERNET LAYER 2 INTERFACE-2 NO
EQUIPMENT CABINETS FOR SDH
VOIP TELEPHONE+ONE COMMON S/W(MIN 8PORT)
48V DC POWER SUPPLY OF 25 AMP RATING
VRLA BATTERY BANK 300AH FOR DCPS
APPROACH CABLING: 24 F (KM)
PMU WITH GPS CLOCK
WAMS - TIME SYSTEM (GPS RECEIVER)
WAMS - SUBSTATION GRADE L3 LAN SWITCH
WAMS - ARMORED FIBRE OPTIC CABLE
SPARE-245KV CIRCUIT BREAKER
SPARE-245KV ISOLATOR
SPARE-216KV SURGE ARRESTER
SPARES-SUBSTATION AUTOMATION SYSTEM
SPARE-RELAY & PROT PANEL (AUTOMATION)
245KV, 1600A, 40KA,1-PH, CT-120% RATING
245KV, 4400PF, 1PH CVT
SPARE-220KV POWER TRANSFORMER
Long Text
250kVA, 33/0.433kV, 3ph LT Transformer
245kV, 1600A, 40KA Circuit Breaker(3-Phase) with support structure
245 kV, 1600A, 40KA, 1-Phase CurrentTransformer with 120% extended current rating
245 kV, 4400pf Capacitive Voltage Transformer (1- Phase)
245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator with one E/S
245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator with two E/S
245kV, 1600A, 40 KA, 3-phase DoubleBreak Tandem Isolator without E/S
245kV, 1600A, 40 KA, 3-phase DoubleBreak Isolator without E/S
216kV Surge Arrester (1-phase)
245 kV, 1 phase Bus Post Insulator (except for Line Traps)
Erection Hardware for 220kV layout (Double Main and bypass isolator)-Bus Coupler Bay as per technical specification
Erection Hardware for 220kV layout (Double Main and bypass isolator)-Transformer Bay as per technical specification
Erection Hardware for 220kV layout (Double Main and bypass isolator)-Line Bay as per technical specification
Erection Hardware for 220kV layout (Double Main and bypass isolator)-Complete Bus work (Three Bays) as per technical specification
36 MM MS ROD FOR MAIN EARTHMAT
220kV Bus Bar Protection Panel (Single)-(with Automation)
220kV Transformer Protection Panel (For both HV & MV side)-(withAutomation)
220kV Line Protection Panel (with Automation) at Nagda Solar SS end Including matching Line differential protection relays & necessary Fibre optic cable, along with interface equipment for remote end (Nagda MPPTCL SS)
220kV Circuit Breaker Relay Panel without Auto Reclose (withAutomation)
220kV Circuit Breaker Relay Panel with Auto Reclose (with Automation)
Complete Substation automation System for 220kV bay as per TechnicalSpecification
Complete Substation automation System for controlling and monitoring of Auxilary System including BCUs as per technical specification
220V DCDB
415V Airconditioning DB
415V Emergency Lighting DB(along with 1no. 25kVA 415V/415V lightingtransformer)
415V Main Lighting DB(along with 2 nos.25 kVA 415V/415V Lighting transformer)
415V AC Distribution Board (ACDB) as per Technical Specification
415V Main Switchboard
220V, 300 Ah Battery
220V, 60A/60A Float Cum Boost BatteryCharger
100 kVA Diesel Generator along with control Panel
33KV, 3CX95 SQMM XLPE AL ARMOURED CABLE ALONGWITH ACCESSORIES AS PER TECH. SPECIFICATION
Cable Termination Kit for 33KV 3CX95 SQMM XLPE AL ARMOURED CABLE for 250kVA, 33/0.433kV, 3ph Transformer end (one set consists of complete requirement for Three phases)
Cable Termination Kit for 33KV 3CX95 SQMM XLPE AL ARMOURED CABLE for 33KV HT panel end (one set consists of complete requirement for three phases)
1.1kV grade Control Cables (PVC insulated) along withlugs,glands,straight joints &accessories,etc.
1.1kV grade Power Cables (PVC insulated)along withlugs,glands,straight joints &accessories,etc.
1.1kV grade Power Cables (XLPE insulated) along withlugs,glands,straight joints &accessories,etc.
High wall type split AC unit of 2 TR capacity
PORTABLE FIRE EXTINGUISHER-DCP TYPE 4.5/5 KG
4.5 kg CO2 type Portable Fire extinguisher
9 litre water type Portable Fire extinguisher
Fire Detection and Alarm System for Control Room Building(220kV)
Nitrogen injection type fire protection for 220kV transformer
Lighting Panel type ACP-2 as per technical specification
Lighting Panel type DCP as per technical specification
15A, 240V: Outdoor Receptacle 2 pole, 3-pin modular (type RO) as pertechnical specifications
63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications
Outdoor Power Receptacle for oil filtration unit (250A)
LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS
Control room cum administrative building (220kV) illumination
Fabrication, galvanising and supply of Std LM (50m) includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts
Fabrication, galvanising and supply of Standard 220 kV Gantry B1 including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts
Fabrication, galvanising and supply of Standard 220 kV Tower CA including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts
Fabrication, galvanising and supply of Standard 220 kV Tower CB including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts
Fabrication, galvanising and supply of Standard 220 kV Tower CC including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts
Fabrication, galvanising and supply of Standard 220 kV Tower CD including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts
Fabrication, galvanising and supply of Standard 220 kV Tower CTC including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts
Fabrication, galvanising and supply of Standard 220 kV Tower CTH including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts
Fabrication, galvanising and supply of Std Pipe Structure - 220 kV HIGH BPI including nuts, bolts, all type of washers, packplates, step boltsand gusset plates excluding foundation bolts
Fabrication, galvanising and supply of Std Pipe Structure - 220 kVBPI including nuts, bolts, all type of washers, packplates, step boltsand gusset plates excluding foundation bolts
Fabrication, galvanising and supply of Standard Pipe Structure - 220kV CT including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts
Fabrication, galvanising and supply of Standard Pipe Structure - 220kV HCT including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts
Fabrication, galvanising and supply of Standard Pipe Structure - 220kV CVT including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts
Fabrication, galvanising and supply of Standard Pipe Structure - 220kV ISOLATOR 3Phase including nuts, bolts, all type of washers, packplates,step bolts and gusset plates excluding foundation bolts
Fabrication, galvanising and supply of Standard Pipe Structure - 220kV SA including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts
Fabrication, galvanising and supply of 28mm dia foundation boltsincluding nuts, checknuts, washers and packplates.
Fabrication, galvanising and supply of 40mm dia foundation boltsincluding nuts, checknuts, washers and packplates.
Fabrication, galvanising and supply of 56mm dia foundation boltsincluding nuts, checknuts, washers and packplates
SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS
TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.)
ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD)
TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.)
Equipment Cabinets For SDH
VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT)
48V DCPS - SMPS BASED 48V DC POWER SUPPLY (DCPS) SYSTEM OF 25 AMP RATING
VRLA Battery Bank for DCPS system of 300AH rating
24F (DWSM) APPROACH FIBRE OPTIC CABLE INCLUDING ALL INSTALLATIONHARDWARE SET
PMU with GPS Clock (clock can be either internal or external)
WAMS Hardware - Time System (GPS receiver)
WAMS Hardware - Substation Grade Layer-3 LAN Switches with minimum 4 x10/100 Mbps Ethernet ports and 2 x 1 Gbps Ethernet ports
WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station
Spare-245kV Circuit Breaker
Spare-245kV Isolator
Spare-216kV Surge Arrester
Spares-Substation Automation System
Relay & protection Panels (with automation)
245 kV, 1600A, 40KA, 1-Phase CurrentTransformer with 120% extended currentrating
245 kV, 4400pf Capacitive Voltage Transformer (1- Phase)
SPARE-220KV POWER TRANSFORMER
HSN SAC Number
Total Price (INR)
Award for or against the bidder
Completion Period for balance quantity
Name of Micro and Small Enterprises(MSEs)
Details of the plant from where supplies are proposed.
Name of Micro and Small Enterprises(MSEs)
Cost of withdrawal of the deviation
Factory Address
Establishment of new 220/33 kV, 2x50 MVA Substation at Solar PV Plant Nagda
Total value of Balance Works (B){B=B1+B2}
Date of joining and designation in our organisation
Name of the published index *
CACMAI
FALSE
Indian Labour Bureau, Shimla, Govt. of India (monthly) (Base: 2001 = 100) (www.labourbureau.nic.in)
Yes(Documentary Evidence Attached)
Addressed to (name of the Bank)
Award for or against the bidder
Balance Quantity to be supplied as on
fifteen
sixteen
...[Enter Amendment Date]…
MSE exemption
Purpose of Commission or gratuity
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
price_schedule.xlsx
xlsx • 0.11 MB
02_Attachment-8-Manufacturer Authorization Form.doc
doc • 0.03 MB
04_Attachment-20_KMP Declaration.doc
doc • 0.04 MB
05_Attachment-21-Affidavit of Self certification regarding Minimum Local Content.DOCX
docx • 0.02 MB
06_Attachment-22-Certificate by Auditor.docx
docx • 0.02 MB
07_Attachment-23-Compliance to the process related to the e-RA.docx
docx • 0.02 MB
08_Attachment-24_Declaration regarding events encountered pursuant to ITB Clause 2-1.docx
docx • 0.03 MB
09_Attachment-26-Authorization Certificate issued by Domestic Manufacturer.docx
docx • 0.02 MB
10_Attachment-27-Affidavit for Self Certifictaion-Iron & Steel.docx
docx • 0.02 MB
11_Attachment-28-Certification by the Bidder per DoE Order in line with ITB Clause 2-1.docx
docx • 0.02 MB
12_Attachment-29_Bid Securing Declaration.docx
docx • 0.02 MB
First Envelope-Bid Forms& Attachments.xlsx
xlsx • 0.71 MB
Vol-III_10-Legends.pdf
pdf • 0.03 MB
LT Switchgear R5.pdf
pdf • 0.47 MB
LT Transformer-Rev05.pdf
pdf • 0.07 MB
Power & Control Cable Rev R6.pdf
pdf • 0.26 MB
sec- CRP Rev 09.pdf
pdf • 0.37 MB
Section PMU Rev 0.pdf
pdf • 0.59 MB
Section Structure Rev 6.pdf
pdf • 0.10 MB
Section Telecommunication Systems Rev 02.pdf
pdf • 1.78 MB
Section-Sub-station Automation_Rev04.pdf
pdf • 0.98 MB
Section-Sub-station Automation_STANDARD FACTORY SIMULATION TEST PLAN.pdf
pdf • 0.54 MB
Section-Switchgear-CB_Rev11.pdf
pdf • 0.61 MB
Section-Switchgear-INST_rev11.pdf
pdf • 1.00 MB
Section-Switchgear-ISO_Rev12.pdf
pdf • 0.17 MB
Section_Switchyard Erection_Rev_10.pdf
pdf • 5.99 MB
1_0 GTR Rev 15 .pdf
pdf • 3.09 MB
400kV Transformer specification_Rev 13.pdf
pdf • 4.54 MB
Air conditioning R4.pdf
pdf • 0.04 MB
Batery&Charger R6.pdf
pdf • 1.05 MB
Civil Works Rev 11A.pdf
pdf • 2.00 MB
DG Set Rev 5.pdf
pdf • 0.27 MB
EHV XLPE cable Rev01.pdf
pdf • 0.60 MB
Fire Protection Rev 6.pdf
pdf • 1.97 MB
Lighting Specification Rev_07.pdf
pdf • 4.29 MB
Annex-I C-13i 220 Beam 2B1.pdf
pdf • 5.55 MB
Annex-I C-13j LM 50 meter.pdf
pdf • 4.74 MB
Annex-I C-14 Security Hut Details.pdf
pdf • 0.21 MB
Annex-I C-15 HBPI Structure Dwg.pdf
pdf • 0.48 MB
Annex-I C-16 474006-220kv 2CT(SH_1 OF 1).pdf
pdf • 0.57 MB
Annex-I C-17 HCT Structure Dwg.pdf
pdf • 0.26 MB
Annex-I C-18 474003-220kv 2CVT(SH_1 OF 1).pdf
pdf • 0.45 MB
Annex-I C-19 474005-220kv 2ISO(SH_1 OF 1).pdf
pdf • 0.56 MB
Annex-I C-20 474004-220kv 2LA(SH_1 OF 1).PDF
pdf • 0.43 MB
Annex-I C-21 474001-220kv 2BPI(SH_1 OF 1).pdf
pdf • 0.49 MB
Annex-I C-22 Concept drawing of PEB.pdf
pdf • 0.09 MB
Annex-I C-23 28mm Dia Foundation bolt.pdf
pdf • 0.08 MB
Annex-I C-24 40mm Dia Foundation bolt.pdf
pdf • 0.11 MB
Annex-I C-25 56mm Dia Foundation bolt.pdf
pdf • 0.10 MB
Annex-I C-13e 220 TOWER 2CD 2of2.pdf
pdf • 5.07 MB
Annex-I C-13f 220 TOWER CTC.pdf
pdf • 5.30 MB
Annex-I C-13g 220 TOWER CTH.pdf
pdf • 4.80 MB
Annex-I C-13h 220 TOWER Peak 2P1.pdf
pdf • 4.07 MB
Annex-I C-13a 220 TOWER 2CA.pdf
pdf • 5.23 MB
Annex-I C-13b 220 TOWER 2CB.pdf
pdf • 5.15 MB
Annex-I C-13c 220 TOWER 2CC.pdf
pdf • 4.97 MB
Annex-I C-13d 220 TOWER 2CD 1of2.pdf
pdf • 1.57 MB
Annex-I List of Drawings.pdf
pdf • 0.42 MB
Annex-I A-1 Tender Drawing GA plan.pdf
pdf • 0.28 MB
Annex-I A-2 Tender Drawing SLD.pdf
pdf • 0.21 MB
Annex-I A-3 Tender Drawing Sectional Layout.pdf
pdf • 0.25 MB
Annex-I B-1 SLD AC SYSTEM.pdf
pdf • 0.34 MB
Annex-I B-2 SLD DC SYSTEM.pdf
pdf • 0.15 MB
Annex-I C-1 Tentative Overall Layout plan of Solar PV plant.pdf
pdf • 0.22 MB
Annex-I C-10 Septic Tank drwing for CRB.pdf
pdf • 0.34 MB
Annex-I C-11a Latest drawing of CHAIN LINK FENCING.pdf
pdf • 1.44 MB
Annex-I C-11b Latest drawing of switchyard gate.pdf
pdf • 1.20 MB
Annex-I C-12 LM 40m foundation.pdf
pdf • 0.14 MB
Annex-I C-2 Fdn Drwgs 220 Tower CA CB CTC.pdf
pdf • 0.28 MB
Annex-I C-3 Fdn Drwgs 220 Tower CC CD CTH.pdf
pdf • 0.25 MB
Annex-I C-4 Fdn Drwgs 220 Eqpts CT CVT ISO SA BPI.pdf
pdf • 0.34 MB
Annex-I C-5 BITUMENOUS ROAD.pdf
pdf • 1.30 MB
Annex-I C-6 Drain-R0-2016.pdf
pdf • 2.24 MB
Annex-I C-7 Cable Trench Dwgs modified.pdf
pdf • 0.63 MB
Annex-I C-8 Parking Shed.pdf
pdf • 1.27 MB
Annex-I C-9 UnderGround Water Tank.pdf
pdf • 2.63 MB
1 of 2 SFQPs erection.pdf
pdf • 7.72 MB
2 of 2 SFQPs erection.pdf
pdf • 8.86 MB
Annex-II Mandatory Spares.pdf
pdf • 0.36 MB
Annex-III Major Technical parameters of Power Transformer.pdf
pdf • 0.97 MB
Annex-IV Specific Requirement_Rev 07 with Annexures.pdf
pdf • 5.79 MB
Section Project.pdf
pdf • 0.85 MB
Standard Field Quality Plan Switchyard Civil Works Revision 06.pdf
pdf • 2.40 MB
01- IFB_SS.pdf
pdf • 0.23 MB
02 Section - II ITB.pdf
pdf • 0.57 MB
03- Section-III-BDS_SS.pdf
pdf • 0.29 MB
04-Annexure-A (BDS)_SS.pdf
pdf • 0.40 MB
04-Annexure-B to BDS_SS.pdf
pdf • 0.49 MB
04-Annexure-C to BDS_SS.pdf
pdf • 0.32 MB
05-Section - IV GCC -S&I_SS.pdf
pdf • 1.93 MB
06- Section-V-SCC_SS.pdf
pdf • 0.39 MB
07- Appendix-I to SCC.pdf
pdf • 0.25 MB
08-Section - VI Forms and Proceedures_SS-85.doc
doc • 0.53 MB
Bid Security Declaration.pdf
pdf • 0.39 MB
~$ Section - II ITB.docx
docx • 0.00 MB
~$- IFB_SS.docx
docx • 0.00 MB
~$- Section-III-BDS_SS.docx
docx • 0.00 MB
~$-Annexure-A (BDS)_SS.doc
doc • 0.00 MB
~$-Annexure-B to BDS_SS.docx
docx • 0.00 MB
~$-Annexure-C to BDS_SS.docx
docx • 0.00 MB
Amend-I.pdf
pdf • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .