Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC VILL DAKSHIN SHIBGANJ P O AND P S PATHARPRATIMA DIST SOUTH 24 PARGANAS | SOUTH 24 PARGANAS | WEST BENGAL | ₹4.3 L | L1 | Accepted-AOC AOC issued |
| 2 | L2₹4.7 LRejected-Finance CHATTAPADMAPUR RAMNAGAR DIST PURBA MEDINIPUR | PURBA MEDINIPUR | ₹4.7 L | L2 | Rejected-Finance That the Bid is not L1 |
| 3 | L3₹4.7 LRejected-Finance 119 MONOHAR PUKUR ROAD KOLKATA 700 026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | ₹4.7 L | L3 | Rejected-Finance That the Bid is not L1 |
| Sl No | Description | Qty | Unit | B. ENGINEERING CO. L1 | TAPAN ELECTRICS L2 | UNITED CONSTRUCTION SERVICE L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & delivery 2.0 TR capacity, R407/410 concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr, with 1 No. Rotary compressor, 1 No. IDU of rated power supply - 230V - 1ph-50Hz, 1 No. ODU of rated power supply - 230V, 1ph, 50 Hz, Air-flow/per IDU :- 800cfm, (Make : Hitachi / O-General / Daikin/ Voltas) | 5 | Nos | 69,000 ₹3.5 L | 76,500 ₹3.8 L | 76,250 ₹3.8 L |
| 2.00 | Erection, testing and commissioning charges for the above said 2.0 / 1.5 TR concealed Split / NORMAL SPLIT AC. The Indoor (IDU) & Outdoor (ODU) unit must be supported by structure made of 40 x 40 x 5 mm amgle and tie rod incl. necy. Painting & as per direction & satisfaction of EIC. | 5 | Nos | 5,000 ₹25,000 | 3,250 ₹16,250 | 3,500 ₹17,500 |
| 3.00 | Copper Refrigeration pipe line for Liquid Line hard drawn Cu piping (1/4" OD with 0.6 mm thick) & Copper Refrigeration pipe line for Suction Line hard drawn Cu piping (5/8" OD with 0.7 mm thick) with necy supports & brackets as per direction of EIC (make: Totaline/ Mandeep/ Uniflow) | 70 | Rmt. | 500 ₹35,000 | 535 ₹37,450 | 560 ₹39,200 |
| 4.00 | Supply & Fixing of Nitrile Rubber tube insulation (make : Twiga) of 9 mm thick on Suction & Liquid Line Copper Pipe. | 70 | Rmt. | 10 ₹700 | 30 ₹2,100 | 40 ₹2,800 |
| 5.00 | Control Cabling from Condensing Unit to Control Panel, 4 core 2.5 sq.mm. communication Cable (Mk. Finilex / Havell's / Gloster) | 80 | Rmt. | 80 ₹6,400 | 90 ₹7,200 | 95 ₹7,600 |
| 6.00 | S&charging of R-410 refrigerant | 2 | Kg | 500 ₹1,000 | 800 ₹1,600 | 1,200 ₹2,400 |
| 7.00 | Supply & laying PVC Drain Pipe 25 mm dia with necy claming arrangement as per direction of EIC (make-- Supereme/ Oriplast) | 120 | Rmt. | 80 ₹9,600 | 100 ₹12,000 | 110 ₹13,200 |
| 8.00 | Dismantling old Existing AC Machine with indoor and Outdoor unit and other acessories etc maintainning normalcy and mending good the damages and carry away material from site as per direction of EIC and deposit necessary useful material in section office . | 1 | Job | 4,000 ₹4,000 | 1,000 ₹1,000 | 1,200 ₹1,200 |
| 9.00 | Charges for Scaffolding arrangement including lifting for outdoor & indoor units.(Ground floor to 3rd Floor) | 5 | Nos | 600 ₹3,000 | 1,000 ₹5,000 | 1,000 ₹5,000 |
| 10.00Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties) | ||||||
Tender Value
Refer Docs
EMD Value
₹8,800
Closing Date
2 Jun 2025, 1:00 pmClosed
Assistant Engineer, KMC Electrical Sub-Division
Kolkata Medical College Electrical Sub-Division, P.W.Dte.Green Building, MCH Campus 88, College Street, Kolkata-700073.
Renovation and repairing work at OT in RIO Medical College and Hospital--Air Condition System Work.
2025_WBPWD_849309_1
WBPWD/AE/KMCESD/NIQ-05/25-26
Open Tender
ELECTRICAL WORKS ORG
21 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹8,800
10 Apr 2026
20 May 2025
4 Jun 2025
26 May 2025
2 Jun 2025
26 May 2025
Amount
Supply & delivery 2.0 TR capacity, R407/410 concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr, with 1 No. Rotary compressor, 1 No. IDU of rated power supply - 230V - 1ph-50Hz, 1 No. ODU of rated power supply - 230V, 1ph, 50 Hz, Air-flow/per IDU :- 800cfm, (Make : Hitachi / O-General / Daikin/ Voltas)
Erection, testing and commissioning charges for the above said 2.0 / 1.5 TR concealed Split / NORMAL SPLIT AC. The Indoor (IDU) & Outdoor (ODU) unit must be supported by structure made of 40 x 40 x 5 mm amgle and tie rod incl. necy. Painting & as per direction & satisfaction of EIC.
Copper Refrigeration pipe line for Liquid Line hard drawn Cu piping (1/4" OD with 0.6 mm thick) & Copper Refrigeration pipe line for Suction Line hard drawn Cu piping (5/8" OD with 0.7 mm thick) with necy supports & brackets as per direction of EIC (make: Totaline/ Mandeep/ Uniflow)
Supply & Fixing of Nitrile Rubber tube insulation (make : Twiga) of 9 mm thick on Suction & Liquid Line Copper Pipe.
Control Cabling from Condensing Unit to Control Panel, 4 core 2.5 sq.mm. communication Cable (Mk. Finilex / Havell's / Gloster)
S&charging of R-410 refrigerant
Supply & laying PVC Drain Pipe 25 mm dia with necy claming arrangement as per direction of EIC (make-- Supereme/ Oriplast)
Dismantling old Existing AC Machine with indoor and Outdoor unit and other acessories etc maintainning normalcy and mending good the damages and carry away material from site as per direction of EIC and deposit necessary useful material in section office .
Charges for Scaffolding arrangement including lifting for outdoor & indoor units.(Ground floor to 3rd Floor)
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties)
TAPAN ELECTRICS (BID ID -6485956)
UNITED CONSTRUCTION SERVICE (BID ID -6486164)
stage.html
html • 0.04 MB
techsummary_1897085.pdf
finance_1897085.pdf
BOQ Comparative Chart
xlsx
finsummary_1897085.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
BOQ_1897085.xls
BOQ • 0.34 MB
2911_Form.pdf
Tender Documents • 0.50 MB
suspension.pdf
Additional Documents • 2.91 MB
Download all tender documents and submit your bid