| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC MN SARKAR ROAD MAHANANDAPARA SILIGURI 734401 | DARJEELING | WEST BENGAL | 734401 | ₹42.7 L Quoted ₹44.4 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹46.7 LRejected-Finance 30 HAREN MUKHERJEE ROAD HAKIMPARA SILIGURI 734 001 DARIEELING WB | DARJEELING | WEST BENGAL | 734001 | ₹46.7 L | L2 | Rejected-Finance Not Lowest Bidder |
| 3 | L3₹47.3 LRejected-Finance KHAPRAIL BAZAR PO NEW CHAMTA DIST DARJEELING WEST BENGAL PIN 734 009 | DARJEELING | WEST BENGAL | 734009 | ₹47.3 L | L3 | Rejected-Finance Not Lowest Bidder |
| 4 | L4₹47.7 LRejected-Finance | ₹47.7 L | L4 | Rejected-Finance Not Lowest Bidder |
| 5 | L5₹47.7 LRejected-Finance JYOTIRMAY COLONY WARD NO 32 P O SILIGURI BAZAR P S BHAKTINAGAR SILIGURI JALPAIGURI 734005 | SILIGURI | JALPAIGURI | WEST BENGAL | 734005 | ₹47.7 L | L5 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | MS ORIENT ENGINEERING WORKS L2 | ELECTRO WIR WAY L1 | DAS AND GHOSH CONSTRUCTION L7 | M/S RANEN PAL L6 | Janata Enterprises L8 | D K SARKAR L3 | M/S. KARMAKAR ENGINEERING COMPANY L5 | PAUL CONSTRUCTION L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Soft/ Loose soil complete all as specified and directed. | 400 | Sqm | 35 ₹14,000 | 30 ₹12,000 | 42 ₹16,800 | 30 ₹12,000 | 33 ₹13,200 | 30 ₹12,000 | 35 ₹14,000 | 40 ₹16,000 |
| 2.00 | Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and not exceeding 1.5 m in depth getting out in soft / loose soil complete all as specified and directed. | 250 | Cum | 165 ₹41,250 | 150 ₹37,500 | 165 ₹41,250 | 150 ₹37,500 | 156 ₹39,000 | 152 ₹38,000 | 160 ₹40,000 | 180 ₹45,000 |
| 3.00 | Excavation in trenches not exc. 1.50 m wide and exc. 1.50 m in depth but not exc. 3.00 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and not exceeding 1.5 m in depth getting out in soft / loose soil complete all as specified and directed. | 1 | Cum | 190 ₹190 | 180 ₹180 | 198 ₹198 | 180 ₹180 | 188 ₹188 | 170 ₹170 | 190 ₹190 | 220 ₹220 |
| 4.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed. | 145 | Cum | 89 ₹12,905 | 80 ₹11,600 | 98 ₹14,210 | 80 ₹11,600 | 88 ₹12,760 | 89 ₹12,905 | 90 ₹13,050 | 100 ₹14,500 |
| 5.00 | Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in Soft/ Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed. | 30 | Each | 360 ₹10,800 | 350 ₹10,500 | 378 ₹11,340 | 350 ₹10,500 | 355 ₹10,650 | 345 ₹10,350 | 340 ₹10,200 | 120 ₹3,600 |
| 6.00 | Removing Excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point complete all as specified and directed. | 90 | Cum | 190 ₹17,100 | 180 ₹16,200 | 198 ₹17,820 | 180 ₹16,200 | 188 ₹16,920 | 180 ₹16,200 | 190 ₹17,100 | 140 ₹12,600 |
| 7.00 | M & L for Hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed. | 25 | Cum | 1,860 ₹46,500 | 1,850 ₹46,250 | 1,875 ₹46,875 | 1,850 ₹46,250 | 1,855 ₹46,375 | 1,840 ₹46,000 | 1,890 ₹47,250 | 2,050 ₹51,250 |
| 8.00 | M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. | 6 | Cum | 4,300 ₹25,800 | 3,480 ₹20,880 | 4,300 ₹25,800 | 4,200 ₹25,200 | 4,250 ₹25,500 | 4,500 ₹27,000 | 4,300 ₹25,800 | 4,600 ₹27,600 |
| 9.00 | M&L cement concrete 1:2:4 type B1, (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, benching, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating and including necessary formwork complete all as specified and directed. | 2 | Cum | 5,200 ₹10,400 | 3,850 ₹7,700 | 5,300 ₹10,600 | 5,100 ₹10,200 | 5,200 ₹10,400 | 5,000 ₹10,000 | 5,300 ₹10,600 | 6,400 ₹12,800 |
| 10.00 | S & F Mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. | 550 | Kg. | 145 ₹79,750 | 140 ₹77,000 | 147 ₹80,850 | 145 ₹79,750 | 141 ₹77,550 | 145 ₹79,750 | 150 ₹82,500 | 155 ₹85,250 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
26 Mar 2026, 6:00 pmClosed
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist-Darjeeling, WB-734009
REPAIRS AND REPLACEMENTS OF OLD UNSV DAMGED LT POLES 2 POLES AND 4 POLES STRUCTURE GODS LA AND CONNECTED ALLIED WORKS ALONGWITH REPLACEMENT OF OLD UNSV SECURITY FENCING AND PCC OF SUB STN AT DIFFERENT LOCATION UNDER AGE E/M OF GE SUKNA AT MIL STN
2026_MES_755054_1
GE Sukna/9014
Open Tender
Civil Works
180 days
SUKNA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SUKNA
₹80,000
27 Apr 2026
3 Mar 2026
28 Mar 2026
4 Mar 2026
26 Mar 2026
19 Mar 2026
4 Mar 2026 - 26 Mar 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: GARRISON ENGINEER SUKNA
Name of Work : REPAIRS AND REPLACEMENTS OF OLD UNSV DAMGED LT POLES, 2 POLES & 4 POLES STRUCTURE, GOD's LA AND CONNECTED ALLIED WORKS ALONGWITH REPLACEMENT OF OLD UNSV SECURITY FENCING AND PCC OF SUB STN AT DIFFERENT LOCATION UNDER AGE E/M OF GE SUKNA AT MIL STN
Contract No: GE/SUK/ OF 2025-26
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Soft/ Loose soil complete all as specified and directed. Sqm Excess(+) Full Conversion INR
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and not exceeding 1.5 m in depth getting out in soft / loose soil complete all as specified and directed. Cum Excess(+) Full Conversion INR
Excavation in trenches not exc. 1.50 m wide and exc. 1.50 m in depth but not exc. 3.00 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and not exceeding 1.5 m in depth getting out in soft / loose soil complete all as specified and directed. Cum Excess(+) Full Conversion INR
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed. Cum Excess(+) Full Conversion INR
Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in Soft/ Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed. Each Excess(+) Full Conversion INR
Removing Excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point complete all as specified and directed. Cum Excess(+) Full Conversion INR
M & L for Hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed. Cum Excess(+) Full Conversion INR
M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. Cum Excess(+) Full Conversion INR
M&L cement concrete 1:2:4 type B1, (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, benching, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating and including necessary formwork complete all as specified and directed. Cum Excess(+) Full Conversion INR
S & F Mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. Kg. Excess(+) Full Conversion INR
S&F Mild steel screw bolts diameter of neck 5 to 10 mm (machine made) with hexoganal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut, not exc. 5 cm long complete all as specified and directed. Kg. Excess(+) Full Conversion INR
M&L mild steel round bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends for securing chain link fencing, conforming to IS Fe 410-W(Gde.E-250), quality-A, complete all as specified and directed. Kg. Excess(+) Full Conversion INR
Fixing only in repairs chain link fencing including line wires, any mesh, size and type of standards, rails, straining bolts, etc, and including provision of binding wire complete all as specified and directed. Sqm Excess(+) Full Conversion INR
Supply only chain link MS galvanized fencing, of any size or type complete all as specified and directed. Kg Excess(+) Full Conversion INR
M&L 75 mm thick, PCC 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) as in sub base, floors etc complete all as specified and directed. Sqm Excess(+) Full Conversion INR
M&L 60 mm thick factory made chamfered edge cement concrete paver block of M-35 Grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU Mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. Sqm Excess(+) Full Conversion INR
M&L preparation of old plastered wall surfaces and including applying one coat of cement base paint complete all as specified and directed. Sqm Excess(+) Full Conversion INR
M&L preparation of new steel surfaces of any description, not otherwise described over 10 cm width or girth and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Sqm Excess(+) Full Conversion INR
M&L preparation of new steel surfaces of any description, not otherwise described n.exc 10 cm width or girth and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. X RM Excess(+) Full Conversion INR
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed. KG Excess(+) Full Conversion INR
Dismantling post or struts (wood, steel or RCC) any section, including taking out embedded portion in natural ground and making good the disturbed ground complete all as specified and directed. RM Excess(+) Full Conversion INR
Supply and fixing in repair of LED street light luminaire 60 Watt (System Lumen output should not be less than 7200 Lumen) Energy saving and environmental friendly long life made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP-66 protection and Impact resistance of IK07 with 10 KV Built-in Surge Protection device with high performance LEDs,System Lumen Efficacy- > 120 Lm/Watt,power factor >=0.95, polyester powder coated with toughened glass having IP-66 protection, tempered protective polycarbonate diffuser, integrated high efficiency electronic driver with lower THD ,Colour Temp (CCT)- 6500 K operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arrangement complete including LEDs with certification LM 79 for luiminare, LM 80 for LED source including all necessary internally pre-wired and connecting up incl taking down old unsv fittings from bracket of pole with repair/replacement warranty of 5 years of OEM complete all as specified and as directed.Make :- Philips/Crompton/Surya/Havells Each Excess(+) Full Conversion INR
Supply and fixing in repair of 3-phase Main Switch in sheet steel enclosure type FN (TPN) S-D-F of rated current 160 Amps including DIN type fuse links type HN incl taking down old unsv complete all as specified & as directed.Make :- L&T FN 160 TPN/Legrand/Havells Each Excess(+) Full Conversion INR
All as per item No. 23.00 above but of rated current 200 Amps.Make :- L&T FN 200 TPN/Legrand/Havells Each Excess(+) Full Conversion INR
All as per item No. 23.00 above but of rated current 100 Amps.Make :- L&T FN 100 TPN/Legrand/Havells Each Excess(+) Full Conversion INR
Supply and fixing in repair of busbar chamber 4 way of current rating 200 Amps, wall mounted made of ETP grade copper incl cable connection with suitable aluminum lugs & glands complete all as specified & as directed. Make :- Havells Cat No IHBC020004/Legrand/ABB Each Excess(+) Full Conversion INR
Supply and fixing in repair of busbar chamber 4 way of current rating 400 Amps, wall mounted made of ETP grade copper incl cable connection with suitable aluminum lugs & glands complete all as specified & as directed. Make :- Havells Cat No IHBC020004/Legrand/ABB Each Excess(+) Full Conversion INR
S&F MCCB 4P 200 Amps 415V ,50 Hz ,breaking capacity 36 KA, type DU 250 C, Including dismantling/ taking down unsvericeable one complete all as specified and directed. Each Excess(+) Full Conversion INR
S&F MCCB 4P 250 Amps 415V ,50 Hz ,breaking capacity 36 KA, type DU 250 C, Including dismantling/ taking down unsvericeable one complete all as specified and directed. Each Excess(+) Full Conversion INR
S&F MCCB 4P 400 Amps 415V ,50 Hz ,breaking capacity 36 KA, type DU 250 C, Including dismantling/ taking down unsvericeable one complete all as specified and directed. Each Excess(+) Full Conversion INR
M &L of Earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connected using galvanised iron earth lead wire 4 Sqmm as earthing electrode by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe (medium grade) and other end connected to earthing test point as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth up to a distance not exceeding 50 Mtr etc all as shown on electrical plate No. 5 of MES Schedule Part-I complete including testing on completion. On testing after completion if the desired earth resistance is not obtained the earthing will be made again by the contractor at no additional cost and including dimantling complete all as specified and directed. Each Excess(+) Full Conversion INR
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead of GI strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 connected to earthing test point and including dismantling complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 15 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc. Each Excess(+) Full Conversion INR
Supply and fixing earthing continuty conductor or main earthing lead fixed to pole or burried in ground or at any other situation for loop earthing extra as required of GI strip 25x4 mm complete all as specified and directed. RM Excess(+) Full Conversion INR
Supply and fixing of 9 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimensions of Pole as Top Diameter not less than 70 mm, Bottom Diameter not less than 155 mm, Section Length not less than 9000 mm, Thickness not less than - 3 mm, Foundation type Base Plate size not less than 250 x 250 x 16 mm , Foundation Bolts - 4 Nos not less than 24 mm dia, pitch circle dia not less than 250 mm, bolt length appox 750 mm, projects bolt length appox 125 mm , with Double type arm bracket not less than 1500 mm long each arm , top dia not less than 70 mm , suitable for LED Street Light fittings.The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding all as specified and as directed. Note :-Excavation and PCC will be measured and paid seprately.) Each Excess(+) Full Conversion INR
Supply and fixing of 9 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimensions of Pole as Top Diameter not less than 70 mm, Bottom Diameter not less than 155 mm, Section Length not less than 9000 mm, Thickness not less than - 3 mm, Foundation type Base Plate size not less than 250 x 250 x 16 mm , Foundation Bolts - 4 Nos not less than 24 mm dia, pitch circle dia not less than 250 mm, bolt length appox 750 mm, projects bolt length appox 125 mm , with Single type arm bracket not less than 1500 mm long each arm , top dia not less than 70 mm , suitable for LED Street Light fittings.The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding all as specified and as directed.Note :-Excavation and PCC will be measured and paid seprately.) Each Excess(+) Full Conversion INR
Supply & fix lightening arrestor linear resistance type distribution class 9 KV RMS suitable for 11 KV system pole mounting type conforming to IS - 3070 Part-I including taking down existing U/S one complete all as specified and directed. Set of three Excess(+) Full Conversion INR
M&L for Weather proof flat three core PVC insulated and PVC sheathed industrial round 3 core flexible copper cable of size 2.5 Sqmm 1100 volts grade for connection of lights to Pole Box, after dismantling old one complete as specified and directed. Rm Excess(+) Full Conversion INR
Supply and fixing of GI tubing light grade 15mm dia fixing to pole from JB to security light complete incl fixing arrangement to pole with the help of 03 pairs of clamps and nut bolts complete all as specified and directed. Rm Excess(+) Full Conversion INR
S & F in repair of Pole mounted Junction box with terminals of size 210 x 260 x 117 mm ,made of high quality thermoplastic polycarbonate, dust & jet water proof, chemical, acid corrision, impact IK-09, insulated & shock proof IP 66, grey RAL 7035 color with internaly embedded gasket (PUR) , along with cover and metric knockout all sides including back of the base must including terminals 4Nos including fixing arrangement with MS flat of size 40X4mm , nuts , bolt and washers and MCB SP 6-32 Amps 01 No including taking down old unsv complete all as specified and as directed. Make :Hensel Cat Part No CJB008PS/ Sintex /Emitter Each Excess(+) Full Conversion INR
S&F in replacement for 32 mm dia GI tubing light grade bracket over all 1.2 mtr length bent to shape 120 degree with cutting as required and bend to shape with flat iron clamp of size 32x6 mm, 2 Nos, suitable size of nut bolts and washers complete for fixing street light fittings on electric poles/bldgs for security complete all as specified and directed.. Each Excess(+) Full Conversion INR
M&L for painting of steel tubular poles 11 mtr height with one coat of aluminium paint from bottom to top including cross arms, GI brackets etc after cleaning and preparing the surface and marking alternate yellow and black strips 30 cm height total 5 Nos with two coats of synthetic enamel point over a coat of primer complete all as specified and as directed. Each Excess(+) Full Conversion INR
M & L for Painting of HT 2-pole structure complete with cross arms,channels, clamps,nut bolts of any length and shape for HT overhead line with single coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 20 cm dia RED circle with yellow colour numbering with synthetic enamelled paint and strip marking of THREE RED AND THREE BLACK alternatively of width 15 cm by fluorescent paint, from bottom of pole to 90 CM height and providng three nos of Red ,Yellow & Blue of reflecting strip of 25 mm width adhesive PVC tape around the pole at suitable height complete all as specified and directed. Each job Excess(+) Full Conversion INR
M & L for Painting of HT 4 -pole structure complete with cross arms,channels, clamps,nut bolts of any length and shape for HT overhead line with single coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 20 cm dia RED circle with yellow colour numbering with synthetic enamelled paint and strip marking of THREE RED AND THREE BLACK alternatively of width 15 cm by fluorescent paint, from bottom of pole to 90 CM height and providng three nos of Red ,Yellow & Blue of reflecting strip of 25 mm width adhesive PVC tape around the pole at suitable height complete all as specified and directed. Each job Excess(+) Full Conversion INR
M & L in repair for PCC earth pit chamber of internal dimension 300x300x300 mm and having wall thickness 100 mm using PCC 1:2:4 type B1 alongwith RCC 1:2:4 type B1 precast cover 50mm thick reinforced with 8 mm TMT bars both way & 100mm C/C including one lifting handle and dismantling of old one complete all as specified and directed. Each job Excess(+) Full Conversion INR
Testing of earth resistance of transformer installations after disconnecting from body / neutral of the transformer and from the lightening arresters / HT / LT panels / 2 pole / 4pole structures and the earth continuity of OH earth wire including writing the results in the existing earthing after removing the existing letters by applying one coat of black paint. Note :- (a) Test results obtained shall be recorded and produced to the Engr-in-Charge and the same will be marked on earth pit indicator/earth pit cover.(b) Measuring equipments and T&P required shall be arranged by the contractor.(c) Writing of letters shall be carried out by engaging highly skilled artist. Each job Excess(+) Full Conversion INR
M & L for cleaning , scraping out old rubbed paint / rust & Painting of transformer complete of capacity up to 63 to 250 KVA 11/.433 KV outdoor / Indoor type with one coat of spray painting with synthetic enamelled gray paint (first grade) by sprey painting machine on transformer & Making SM NO on surface of transformer complete all as specified and directed. Each Excess(+) Full Conversion INR
M & L for cleaning , scraping out old rubbed paint / rust & Painting of transformer complete of capacity up to 300 to 500 KVA 11/.433 KV outdoor / Indoor type with one coat of spray painting with synthetic enamelled gray paint (first grade) by sprey painting machine on transformer & Making SM NO on surface of transformer complete all as specified and directed. Each Excess(+) Full Conversion INR
Dismantling of steel poles/struts any size embedded in concrete including demolition of concrete, etc and removing unserviceable materials from site of work complete all as directed by Engr-in-charge. Each Excess(+) Full Conversion INR
M&L for sand coushioning to UG cables (8cm deep before laying of cables and 15 cm over the cable) including spreading, levelling, well ramming in layers complete all as specified and directed. NOTE:- punned thickness of 18cm only will be considered for measurement and payment. Cum Excess(+) Full Conversion INR
M&L for brick protection cover of size 230 x 115 x 75mm to LT underground cables with sub class ‘B’ over brunt brick, (Locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and directed. Per 1000 No Excess(+) Full Conversion INR
Boring/Drilling (horizontally) manually under 2m deep in soil below existing road suitable for passing GI tubing of 40 to 80 mm bore complete all as specified and directed. RM Excess(+) Full Conversion INR
Supply and fixing of GI tubing light grade 40mm dia for protection of cable on pole , under road crossing or across drain , along electric pole or floor / wall including taking down old unsv complete all as specified and directed. RM Excess(+) Full Conversion INR
Supply and fixing in repair of GI tubing light grade 80mm dia for protection of cable on pole , under road crossing or across drain , along electric pole or floor / wall including taking down old unsv complete all as specified and directed. RM Excess(+) Full Conversion INR
Supply, laying testing and commissoning in replacement of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) LT Cable with stranded aluminium conductor 1100 volts grade of size 25 sqmm 4 core including taking down old unsv complete all as specified and directed. RM Excess(+) Full Conversion INR
Supply, laying testing and commissoning in replacement of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) LT Cable with stranded aluminium conductor 1100 volts grade of size 50 sqmm 3.5 core including taking down old unsv complete all as specified and directed. RM Excess(+) Full Conversion INR
Supply, laying testing and commissoning in replacement of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) LT Cable with stranded aluminium conductor 1100 volts grade of size 95 sqmm 3.50 core including taking down old unsv complete all as specified and directed. RM Excess(+) Full Conversion INR
Supply, laying testing and commissoning in replacement of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) LT Cable with stranded aluminium conductor 1100 volts grade of size 150 sqmm 3.50 core including taking down old unsv complete all as specified and directed. RM Excess(+) Full Conversion INR
Supply, laying testing and commissoning in replacement of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) LT Cable with stranded aluminium conductor 1100 volts grade of size 240 sqmm 3.50 core including taking down old unsv complete all as specified and directed. RM Excess(+) Full Conversion INR
Supply, transportation, fixing and erection of steel tubular sewaged pole 9 mtr long complete with MS base plate ,finial taper plug nut bolts,screws as specified type 410 SP-31 as per relevant IS specification including two coats of aluminium paint over a coat of red oxide primer and including making alternate red and black strips 30 cm height (Total 5 Nos ) and removing the old U/S one complete all as specified and directed. Note :- (Excavation and PCC will be measured and paid seprately.) Each Excess(+) Full Conversion INR
Supply, transportation, fixing and erection of steel tubular sewaged pole 11 mtr long complete with MS base plate ,finial taper plug nut bolts,screws as specified type 410 SP-31 as per relevant IS specification including two coats of aluminium paint over a coat of red oxide primer and including making alternate red and black strips 30 cm height (Total 5 Nos ) and removing the old U/S one complete all as specified and directed. Note :- (Excavation and PCC will be measured and paid seprately.) Each Excess(+) Full Conversion INR
Dismantling of insulator of any size/type and setting aside the serviceable insulator for reuse at site and removing unserviceable insulators from site of work complete all as directed. Each Excess(+) Full Conversion INR
Supply & fix insulator pin type porcelain , vitreous , white ,brown or green 150 mm height and 150 mm dia including one galvanised mild steel spindle , two galvanised washers and one galvanised iron nuts for conductor working pressure 11000 Volts grade complete all as specified and directed Each Excess(+) Full Conversion INR
Supply & fix single Disc assembly insulator for tension with tension clamps to the conductors porcelain type , vitreous , white ,brown or green 145 mm height and 255 mm dia ball and socket type, working pressure 11000 Volts grade complete all as specified and directed. Each Excess(+) Full Conversion INR
Opening the binding wire from pin / shackle/Disc insulator on HT/LT pole for re-stretching the ACSR conductor , after re-stretching without kinks & bends, binding the Pin/Shackle/Disc insulator with appropriate size of aluminium binding wire complete all specified & directed by Engineer-in- Charge. Note-: (i) The above work includes clearing/ prooning of tree branches falling around the conductors.(ii) Cost of binding wire deemed to be included in the quoted rate ,No extra amount will be paid. RM Excess(+) Full Conversion INR
M&L of aluminium conductor steel reinforced (ACSR) on pole ,stringing properly on insulators and binding with aluminium binding wire , jumpers etc complete for any size ( Mink , Dog ,Ferret ,Weasel ,Squirel of conductor. Note : - Measurement & Payment shall be made by measuring horizontal distance between centre of two adjaacent pole and adding 3% extra for sag , joints and jumper etc . Per Qtl Excess(+) Full Conversion INR
Supply & fix insulator pin type porcelain , vitreous , white ,brown or green 100 mm height and 65 mm dia including one galvanised mild steel spindle , two galvanised washers and one galvanised iron nuts for conductor working pressure 1100 Volts grade complete all as specified and directed. Each Excess(+) Full Conversion INR
Supply & fix insulator shackle type porcelain , vitreous , white ,brown or green 75 mm height and 90 mm dia including galvanised mild steel straps os size 31mm x 3mm, washers,insulator bolts, washers and nuts complete for conductor working pressure 1100 Volts grade complete as specified and directed. Each Excess(+) Full Conversion INR
S&F of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm including taking down old unsv complete all as specified and as directed. Each Excess(+) Full Conversion INR
Supply and fixing in repair Switch air break, gang operated triple pole mechanically operated mounted on with 9 insulator and steel frame with operating mechanism working from ground level current rating upto 400A, 11000 V grade having nine insulators, vertical type including dismantling of existing air break gang operated switch and removal the same from site complete all as specified and directed. Each Set Excess(+) Full Conversion INR
Supply and fixing in repair expulsion drop out fuse carrier assembly outdoor type 400 Amps capacity including fuse element up to 60 Amps and insulator suitable for HT 11 KV complete and dismantling of existing fuse carrier assembly and removal the same from site complete all as specified and as directed. Each Excess(+) Full Conversion INR
Supply & fixing Aluminium lugs suitable for UG cable of size 3.5/4 core, 50 to 95 sqmm and making connection to MCCB/MCB including respective size of lugs for the neutral cable complete all as specified and as directed. Each Excess(+) Full Conversion INR
Supply & fixing Aluminium lugs suitable for UG cable of size 3.5/4 core, 120 to 240 sqmm and making connection to MCCB/MCB including respective size of lugs for the neutral cable complete all as specified and as directed. Each Excess(+) Full Conversion INR
M&L for Jumper connection between OH line to GOD and GOD to drop out fuses with ACSR conductor 6/1X3.35 mm (rabbit) not exe. 2 mtr long including necessary lugs where ever required/aluminum heavy duty PG clamps contact all as directed after removing the old jumpers including PVC sleeve not more than 1.70 Rm complete all as specified and directed. Each Excess(+) Full Conversion INR
Supply fabricate, fixing structural mild steel RS joist , channel angle iron, flat iron and brackets etc for fabrication of cross arms, bracing supports clamps including D clamps, eye hook and back plate etc fabricated from structural steel section including nuts , bolts, washers, welding (cold and hot ) drilling holes for bolts, bend to any shape or size as indicated and directed , inclusive of one primer coat and two coats of aluminium paint after preparation of surfaces complete all as specified and directed . Qtl Excess(+) Full Conversion INR
Dismantling and taking down old unserviceable LT busbar panel and Supply, installation, testing and commissioning of LT busbar Panel board not less than 0.5m x 0.6 m x0.50 m , outdoor cubical type factory made (CPRI approved) with canopy,double door , front & back both side openable type fixed with Hinges and locking arrangement with Aldrop latches , fabricated of CRCA sheet , inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer door 3.15 mm thick,rubberised gasket, supported on 50x 50 x 6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 400 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity aluminium bus bar / PVC insulated copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & wahsers with danger notice plate. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and lugs to accommodate complete all as specified & as directed. Each Excess(+) Full Conversion INR
Supply, installation, testing and commissioning of Panel board not less than 1.70m x 1.70 m x 0.50 m , outdoor cubical type factory made (CPRI approved) ,double door , front & back both side openable type fixed with Butt Hinges and locking arrangement with Aldrop latches , fabricated of CRCA sheet , inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer door 3.15 mm thick,rubberised gasket, supported on 50x 50 x 6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 400 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity aluminium bus bar / PVC insulated copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & wahsers. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and lugs to accommodate and including the following :- Each Excess(+) Full Conversion INR
INCOMING :- Aluminium busbar 400 Amps rated capacity-04 Nos. 250A 4P 36KA MCCB with O/L, S/C Thermal Mag Release-02 Nos MCCB Extended Rotary Handle-02 Nos Spreader Link-02 Nos MCCB Aux+Trip Unit-01 No Chang over switch 250A 4P-01 No C T Coil 250/5-03 Nos R,Y,B,On,Off,Trip indicator lamps LED-06 Nos Digital Ammeter inbuilt selector switch (M1V3)-01 No Digital Voltmeter inbuilt selector switch(M1A3)-01 No Fuse/ MCB 6A SP for meter Protection-03 Nos OUTGOING :- 200A 4P 36KA MCCB with O/L, S/C Thermal Mag Release-01 Nos MCCB Extended Rotary Handle-01 No Spreader Link-01 No 100A 4P 25KA MCCB with O/L, S/C Thermal Mag Release-02 Nos MCCB Extended Rotary Handle-02 Nos Spreader Link-02 Nos 63A 4P 25KA MCCB with O/L, S/C Thermal Mag Release-06 Nos MCCB Extended Rotary Handle-06 Nos Spreader Link-06 Nos MCB 63A 4P 10KA-02 Nos Terminal 63A 4P-02 Nos Danger Notice plate - 02 No. Panel control wiring complete with suitable size copper wire - 01Job.
Testing the power factor improvement static power capacitor bank of any capacity and taking out the unsv or de-rated capacitors & Supply and fixing Ultra heavy duty extended life capacitors LTXL (Box type) of any capacity , 440V 3 phase 50 Hz, all as directed at site. Make : Havells/L&T/Legrand Per KVAr Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.77 MB
Tenderdoc9014.pdf
Tender Documents • 1.75 MB
BOQ_845719.xls
BOQ • 0.36 MB