Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹41.2 L+₹1,680.95 (0.04%)Rejected-Finance HOUSE NO 49 SECTOR 28 FARIDABAD 121008 HR | FARIDABAD | FARIDABAD | HARYANA | 121008 | L2 | Rejected-Finance Other than L1 bidder | |
| 3 | L3₹42.2 L+₹1.1 L (2.62%)Rejected-Finance | L3 | Rejected-Finance Other than L1 bidder |
| Sl No | Description | Qty | Unit | M/S HONY CAPT RIGZIN SAMPHEL L3 | M/S Chib Engineers L1 | M/S Behl Sons L2 |
|---|---|---|---|---|---|---|
| 1.00 | Taking out un-serviceable/faulty cable/service connection cable of any grade / type / class of any size for repair / replacement from pole / wall / cable duct under ground trench etc for re-use or removal from site of work all as specified and as directed by the Engineer-in-charge (Note- Excavation and earth work shall be measured and paid separately) | 2,030 | RM | 12 ₹24,360 | 1 ₹2,030 Lowest | 10 ₹20,300 |
| 2.00 | Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3 core 1.5 sqmm all as specified and directed.(Make -Havells/KEI/Polycab) | 200 | RM | 165 ₹33,000 | 100 ₹20,000 Lowest | 150 ₹30,000 |
| 3.00 | Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 2 core 10 sqmm all as specified and directed. (Make -Havells/KEI/Polycab) | 150 | RM | 215 ₹32,250 | 200 ₹30,000 Lowest | 210 ₹31,500 |
| 4.00 | Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 2 core 16 sqmm all as specified and directed.(Make -Havells/KEI/Polycab) | 250 | RM | 285 ₹71,250 | 220 ₹55,000 Lowest | 280 ₹70,000 |
| 5.00 | Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 4 core 16 sqmm all as specified and directed.(Make -Havells/KEI/Polycab) | 380 | RM | 395 ₹1,50,100 | 240 ₹91,200 Lowest | 390 ₹1,48,200 |
| 6.00 | Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 25 sqmm all as specified and directed.(Make -Havells/KEI/Polycab) | 250 | RM | 425 ₹1,06,250 | 300 ₹75,000 Lowest | 420 ₹1,05,000 |
| 7.00 | Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 50 sqmm all as specified and directed.(Make -Havells/KEI/Polycab) | 350 | RM | 529 ₹1,85,150 | 450 ₹1,57,500 Lowest | 520 ₹1,82,000 |
| 8.00 | Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 70 sqmm all as specified and directed.(Make -Havells/KEI/Polycab) | 400 | RM | 795 ₹3,18,000 | 550 ₹2,20,000 Lowest | 760 ₹3,04,000 |
| 9.00 | Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 95 sqmm all as specified and directed. (Make -Havells/KEI/Polycab) | 50 | RM | 1,020 ₹51,000 | 720 ₹36,000 Lowest | 980 ₹49,000 |
| 10.00 | M&L for line separators of LT OH lines with nut, bolts & washers straight type fixed at a point as directed and suitable for 4 wire complete all as specified and directed by Engr-in-Charge. | 20 | Each | 120 ₹2,400 | 120 ₹2,400 | 100 ₹2,000 Lowest |
Tender Value
₹38.3 L
EMD Value
₹76,600
Closing Date
6 Sept 2025, 6:00 pmClosed
GE 873 EWS
Garrison Engineer 873 Engineer Works Section PIN 913 873 C/O 56 APO
SPL REPAIR OF VARIOUS EXTERNAL SUPPLY ITEMS, LT PANELS UNDER GROUND CABLE AND OTHER ALLIED WORKS AT OLD SIG COY AT PRATAP PUR UNDER GE 873 EWS
2025_MES_726313_1
GE/873/EWS-67/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 873 EWS
Please refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE 873 EWS
₹76,600
Yes
19 Sept 2025
16 Aug 2025
8 Sept 2025
16 Aug 2025
6 Sept 2025
30 Aug 2025
18 Aug 2025 - 25 Aug 2025
Amount
Taking out un-serviceable/faulty cable/service connection cable of any grade / type / class of any size for repair / replacement from pole / wall / cable duct under ground trench etc for re-use or removal from site of work all as specified and as directed by the Engineer-in-charge (Note- Excavation and earth work shall be measured and paid separately)
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3 core 1.5 sqmm all as specified and directed.(Make -Havells/KEI/Polycab)
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 2 core 10 sqmm all as specified and directed. (Make -Havells/KEI/Polycab)
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 2 core 16 sqmm all as specified and directed.(Make -Havells/KEI/Polycab)
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 4 core 16 sqmm all as specified and directed.(Make -Havells/KEI/Polycab)
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 25 sqmm all as specified and directed.(Make -Havells/KEI/Polycab)
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 50 sqmm all as specified and directed.(Make -Havells/KEI/Polycab)
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 70 sqmm all as specified and directed.(Make -Havells/KEI/Polycab)
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 95 sqmm all as specified and directed. (Make -Havells/KEI/Polycab)
M&L for line separators of LT OH lines with nut, bolts & washers straight type fixed at a point as directed and suitable for 4 wire complete all as specified and directed by Engr-in-Charge.
Supply and erecting and fixing in proper position steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.00metres long) Make: Advance steel tube, National tubing co, Mahindra industries, sohan lal and sons,Sidhartha all as specified and as directed. Note: (i) Excavation ,earth work and PCC shall be measured and paid separately. (ii) including painting of pole,taking copper/aluminium cable inside the pole from top to Junction box,connecting with junction box.The UG cable at pole will be secured with GI pipe after considering 3 mtr loop on each end.
M & L for bracket made out of GI tubing 25mm dia,light grade 1.5 mtr long including fixing with MS clamps 2 Nos made out of 25 mm wide 3mm thick flat iron with M.S nuts bolts 75 mm long 12 mm dia 4 Nos with flat washer (3mm thick) 2 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete making all necessary connection with suitable capacity of 3 core circular cable taking the cable inside the light bracket and to be insied pole upto cable junction box complete all as specified and directed.
Supply and fixing LED solar street light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete making all necessary connection with suitable capacity of 3 core circular cable complete all as specified and directed.
Supply and Fixing 3 coreX1.5 Sqmm (nominal area) copper conductor from street light at top to Junction box pass through inside the pole complete all as specified and directed.
Supply & fix Junction box of size 280 X 170 X 130 mm Cat No GS-JB-2817 Hinged (L) wiith 2 way connector mounted on epoxy insulators for looping of cable for 1Phase and 1neutral fixed on pole with the help of MS nuts bolts and MS clamps-2 Nos of size 40 mm X 4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box. work also includes making suitable hole in pole to take out connections to fitting if required at site and provisioning of 1.0 sqmm 3.0 core flexible PVC insulated copper cable from junction box to conector of street light.Make - Hensel/Sintex/Havells
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete included junction box for connection complete all as specified and directed. Make:- Crompton/Havells/Philips .
Supply and fixing Garden lights 3Mtr Decorative Pole with PU paint with single arm Decorative bracket (TDS attached ) 45W empire fitting with spun Aluminium Hosing (470mmx516mm) (TDS attached) system efficiency 120lm /W with Silicon get potted driver with 10kv External Surge protection along with junction box black colour with intergated MCB SP complete all as specified and directed. Read: Crompton CAT Ref (Pole)- HM-DECO-03-P-ACC, Crompton CAT Ref (Light)-CBP-601-45,57-HL2-CP-NGG Make:- Crompton/Havells/Philips
Supply and fixing LUNAR BOLLARD decorative Lamp ,superior Metal Body ,Weather proof Coating ,Water resistant IP65 with B22 bulp holder complete all as specified and directed. Cat Part No MUSHROOM NXTBL 10 W LED 83055YMT OPC. Mushroom bollard light Make: Havells.
Supply and fixing TURINBLS10WLED830PSYMTOPC BOLLARD decorative Lamp ,superior Metal Body ,Weather proof Coating ,Water resistant IP66 with B22 bulp holder complete all as specified and directed. Make -Havells HSN code -9405 or equivalent to Crompton/Bajaj
Supply and fixing LED GALAXY ROPE LIGHT IP65 outdoor,Extra Bright ,600 lumens/mtr Waterproofwith warm white/blue/green 120LED/Mtr 220V AC with impact and corrosion resistant complete with driver and lamp complete.Make-Cromton Order code-LSTGLRP120P65-WW/CD/BLU/GRN or equivalent to Crompton/Bajaj
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x06mm thickness not less than 6mm thick buried directly in ground( earth plate not less than1.5 mtr deep below normal ground level) with top edge of earth plate not less than 2.5 mtr below the normal ground level connected to galvanized iron wire 4 mm dia by means of nuts bolts, nuts, check nuts and washers of GI steel all as shown in electrc plate Ni 3 connected to earth test point all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe light grade 40mm bore and GI watering pipe 20mm bore medium grade with funnel and wire mesh ,40mm thick pre cast RCC M-15 ( Nominal mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40X40X3mm frame for cover,PCC M-15 ( Nminal mix) pit, excavation and earth work in any type of soil and connected all as specified and as directed by Engineer-in-charge.
Excavation in trenches hard/dense soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cable, Pole, fixing of stay etc 10 Sqm 2 core/25 Sqmm 4 core/50 Sq mm 4 core on plan and not exc 1.5 in depth and getting out in hard/dence soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and above exceeding 1.5 mtrs in depth for laying of cable,Pole, fixing of stay etc 10 Sqm 2 core/25 Sqmm 4 core/50 Sq mm 4 core on plan and above exc 1.5 in depth and getting out in hard/dence soil complete all as specified and directed.
Returing, filling in incl spreading, levelling watering and well remming in layers n.exc 25cm width, Complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above starting point Completed all as specified and diercted by Engineer-in-Charge.
Sand cushioning for under ground cable 8 cm before laying the cable and 15 cm after laying and streching the cable complete all as specified and directed by Engineer-in-Charge.
M&L Un-reinforced precast factory made concreate cable covers, class LV type-I, with flat size 250x150x40 mm Complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregate of pit for bed concrete in foundation of poles/stay complete all as specified.
Material & Labour for PCC (1:3:6) type C-2 using 40 mm graded aggregate as in foundation of pole/stay and filling of mass concrete including providing necessary form work complete all as specified and as directed.
Material & Labour for PCC (1:2:4) type B-1 using 20 mm graded aggregate as in coping of pole including providing necessary form work complete all as specified and as directed.
Supply and fixing Cable jointing kit for 1.1 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm all as specified and directed.
Supply ,Install Testing & Commissioning of self supporting totally enclosed double door at front, LT feeder piller compartmentalised design, dust and varmin proof of size 800 mm(Height) x 400 mm(Length) x 450 mm(Width) suitable for 440 Volt 3 phase 4 wire system made out of 3.15 mm thick CRCA sheet and built upon regid frame work having front and rear hinged doors with neoprence rubber gasket including danger plate, earthing strip point and, ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size of Zinc/Cromium plated and nuts, bolts ;and washers etc. The pannel shall be synthetic enamelled painted and the control circuit diagram shall be with colour code solid conductor copper 1.5 sqmm cable for easy identification including incomming/outgoing cable holes at the bottom, complete after taking down the old unserviceable one. The Panel shall be emmbeded with 75 x 6 mm MS Angle Iron frame and to be grouted with PCC foundation (1:2:4 ) type B2 upto a height of 50 cm from normal ground level complete all as specified and directed by Engr in charge and comprising of the following. Incommer :- (a) MCCB of , 63 A, 16 KA, with breaking capacity of 25 KA, - 01 No Make : L & T/Havells Outgoing:- (b) MCB of TPN , 40 A, 16 KA, with breaking capacity of 25 KA, - 02 No ( HQ Coy C/H-01 and SP Coy C/H-01) INDICATING DEVICES (a) LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3 (b) Digital Voltmeter (Make AE/L&T) - 01 No (c)Current Transformer having Ratio 400/5, 15 VA - 01 Set of 3 (d) Digital Ammeter ( Make(AE/L&T) - 01 N0 (e) Front operated ON LOAD change over switch 415V, 4 pole of capacity 63 Amps. - o1 No
Supply ,laying & testing GI tubing 40mm bore medium grade conforming to IS : 1239 with all fittings laid in trenches/fixing on walls complete all as specified and directed.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 400 Amps all as specified and as directed by Engineer-in-charge. .
M&L for Aluminium cable lugs / thimbles suitable for cable of size 16 to 35Sqmm complete all as specified and as directed.
M&L for Aluminium cable lugs / thimbles suitable for cable of size 50 to 100Sqmm complete all as specified and as directed.
Supply and fix in repair Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip all as specified and directed.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 125 Amps all as specified and as directed by Engineer-in-charge. .
Deduct Schedule of Credit of Rs 1,83,128 (Minus) as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount. Note :- Tenderers will not quote against this item being a firm amount.
M/S Behl Sons (BID ID -3417900)
M/S HONY CAPT RIGZIN SAMPHEL (BID ID -3417985)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .