Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC RAJKOT ROAD AIR FORCE STATION HALWARA 141106 PUNJAB | HALWARA | LUDHIANA | PUNJAB | 141106 | ₹8.3 L | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹8.6 L+₹32,151.20 (3.89%)Rejected-Finance | ₹8.6 L+₹32,151.20 (3.89%) | L2 | Rejected-Finance Being not lowest |
| 3 | L3₹9.5 L+₹1.2 L (14.6%)Rejected-Finance | ₹9.5 L+₹1.2 L (14.6%) | L3 | Rejected-Finance Being not lowest |
| 4 | L4₹12.4 L+₹4.1 L (49.7%)Rejected-Finance | ₹12.4 L+₹4.1 L (49.7%) | L4 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
24 Oct 2020, 6:00 pmClosed
GE (AF) Halwara
GE (AF) Halwara
REPAIR MAINT OF CEILING FANS EXHAUST FANS WALL MOUNTED FANS AND GEYSERS AT AF STATION BARNALA UNDER GE AF HALWARA
2020_MES_380983_1
GE/HAL-43/2020-21
Open Tender
Civil Works
Item Rate
273 days
GE (AF) Halwara
MES ENLISTED CONTRACTORS CLASS E CATEGORY b i
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹30,000
Yes
27 Oct 2020
26 Sept 2020
26 Oct 2020
26 Sept 2020
24 Oct 2020
10 Oct 2020
Amount
Taking down carefully ceiling / exhaust fan/wall mounted fan of any sweep with frame cable sealing end and dismantling of blades, brackets etc and refixing after repairs, connecting up and testing for satisfactory running complete all as specified and as directed. Note :- Scope of repair is exclusive of this item.
Opening, dismantling of ceiling fans/exhaust fan/wall mounted fan of any size, cutting and taking out old burnt / damaged winding / material by any means and M & L for re-winding the same with super enamelled copper wire of existing / same SWG including all insulating material all as required as per standard practice , varnishing the same and drying, cleaning fan recommended quality grease / oiil, re-assembling with new spare parts as per requirement inlcuding provision of PVC copper twisted conductor three core of size 0.5 sqmm required length and testing complete all as specified and as directed. Note : Spare parts shall be measured and paid serparately as supply only.
Supply only bearing of ceiling / exhaust/wall mounted fan etc complete all as specified. Make : NBC / SKF
Supply only capacitor 415 Volts, 50 Hz 3.15 MFD, complete all as specified. Make : Asian / Epcos / Tibcon.
Bush suitable for ceiling / exhaust/wall mountd fan any sweep, ISI marked complete all as specified and as directed.
Supply only wall fan mounting clamp with connected nut, bolts and washers complete all as specified and directed
S&F modular fan regulator 120 watt W-2 module complete all as specified and directed.
S&F switch modular type single pole one way 6 Amp including suitable size module cover with frame
S&F stepped type electronic fan regulator flush type complete all as specified and directed.
Supply only plug top 15Amp, 3 pin complete all as specified
Supply only plug top 5 Amp, 3 pin complete
Supply only 2.5 Sqmm PVC cable 3 core suitable for geyser connection complete all as specified and directed.
Supply only light grade downrod 45cm long for ceiling fan with connected nut bolts etc complete all as specified.
Supply only wall fan blade cover of any size complete all as specified and directed
S&F of 5 Amp, one way piano switch flush type single pole
Supply only armature shaft of ceiling fan any capacity, ISI marked
Supply only rubber reel with clamps, nut bolts, washers and split pin of suitable size, ISI marked
Supply only fan canopy plastic body suitable for ceiling fan any size and sweep, ISI marked complete
S&F new blades of wall/exhaust fans to replace old broken/damaged blades of any size
S&F new blades of ceiling fans of any size to replace old broken/damaged blades
S&F new louver shutters of exhaust fan of any size & type to replace old louvers
M&L for removing existing paint from ceiling fan including fan body and blades etc and applying one coat of red oxide primer and one coat of synthetic enamel paint with spray gun complete alll as specified and directed.
Taking down carefully water geyser/solar geyser any capacity, cable sealing end and dismantling of heating element, thermostat etc and refixing after repair, connecting up and testing for satisfactorily heating of water complete all as specified and directed. Note : Spare parts to replaced shall be measured and paid separately.
Supply only 2000 watts tri angle type heating element
Supply only 1500 watts tri angle type heating element
Supply only 3000 watt diagonal and threaded type heating element for solar geysers
Supply only of Termostate 7''/9" suitable for 25/50 ltrs capacity water geyser with automatic thermal cutout.
Gas welding work for geyser brackets/inner tanks etc
Suppl only geyser bottom plate with indicator lamp green and red LED
Supply PVC connection (high density) 15mm with PTMT nuts on both ends, 750mm long
Supply only flat plate collector type with heat exchanger of 10 ltrs per day capacity and size of collector 2112x1035x101mm
Lagging to 20mm GI pipe used in internal water supply or plumbing all round with 50 mm thick bonded mineral wool preformed 'SNAP ON' pipe sections of density 144 Kg/Cum conforming to IS 9842
Lagging to 15mm GI pipe used in internal water supply or plumbing all round with 50 mm thick bonded mineral wool preformed 'SNAP ON' pipe sections of density 144 Kg/Cum conforming to IS 9842
M&L for solar water tank insulation with resin bonded fibre glass wool roll of density 24 Kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation as specified and including the followings :- (a) Cleaning the solar tank surface (to be insulated) by scrapping carefully, completely free of mill scale, dirt, dust, grease and other foreign materials, taking special care so that all solar water tank joints are sealed against any leakage. (b) Applying rubber based adhesive CPRX compound. (c) Sealing all longitudinal joints and ciruclar overlaps with and including aluminium foil tape 50mm wide, to make the insulation leakproof. (d) Securing the insulation with and including mechanically fastened nylon/steel straps of size 12mm/50mm at maximum intervals of 1.20m.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping including use of necessary formwork in any situation complete all as specified and directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, dia of nec 11 ro 15mm, each screwed end to be fitted with washers and one hexagonal of square nut, not exc 5 cm long complete all as specified and directed.
Supply only L hook fastener size 10mm dia and 10cm long with connected washers fixing on wall for hanging of geysers etc complete all as specified and directed.
Rolled section as in main cross beam, hip and jack rafters, purlins where connected to common rafters and running rails and guided for sliding door fixed with angle cleats of other connected plates, rivets, nut bolts etc complete all as specified and directed. Qualifty confirming to Fe 410 W(Gde E-25) quality-B.
Supply or laying or fixing or passing through pipe, 1100 volts heavy duty cable with PVC insulated copper conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 Sqmm 2 core complete all as specified and directed.
S K BANSAL AND CO.
SANGAM ENGINEERS
AMRIT ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .