Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC CHENNAI | CHENNAI | TAMIL NADU | 600001 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹32.0 L+₹95,092 (3.07%)Rejected-Finance E 27 CWE WELLINGTON | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L2 | Rejected-Finance Not Being lowest | |
| 3 | L3₹37.3 L+₹6.3 L (20.3%)Rejected-Finance | L3 | Rejected-Finance Not Being lowest |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
10 Apr 2021, 6:00 pmClosed
CWE WELLINGTON
Headquarters, Commander Works Engineers, Military Engineer Services Ministry of defence Wellington, Barraks-Post, The Nilgiris, PIN 643231
SPECIAL REPAIRS TO ITRC RAJENDRA PRASAD BLOCK AT DSSC WELLINGTON
2021_MES_409097_4
84601/E8
Open Tender
Civil Works
Item Rate
180 days
WELLINGTON
D Class a i category
6 documents required · 6 mandatory
₹500
GE DSSC WELLINGTON
₹59,000
Yes
28 Apr 2021
26 Mar 2021
12 Apr 2021
26 Mar 2021
10 Apr 2021
26 Mar 2021
Amount
Dismantling Mangalore pattern tiles laid dry in roofing complete all as specified and directed.
Dismantling battens for tiles, shingles etc of any size including tilting fillets complete all as specified and directed.
Dismantling of unframed timber scantlings 40 sqcm and over in section, in any position tile battens as in roofing complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
M&L Roof tiles Mangalore pattern, interlocking at side joints, laid dry complete all as specified and directed.
Fixing only Roof tiles Mangalore pattern, interlocking at side joints, laid dry complete all as specified and directed.
M&L Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and directed.
All as per item No. 8 here-in-before but except tiles
M&L Second class hardwood tile battens, clean sawn with sectional area exceeding 15 sqcm but not exceeding 25 sqcm at 30 cm centers complete all as specified and directed.
All as per item No. 10 here-in-before but except battens complete all as specified and directed.
M&L Second class hard-wood scantlings, clean sawn as in roof members complete all as specified and directed.
M&L for Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with Creosote all as specified and directed
M&L 0.80mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc with grade of zinc coating 275, in patches, complete all as specified and directed.
All as per item No. 14 here-in-before but except Galvanised steel sheets complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.60mm thick coloured having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.60mm thick coloured having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L 30mm thick second class hard wood boarding, clean swan fixed with nails in any situation (except flooring and skirting) complete all as specified and directed.
M&L Preparation of new or previously un-treated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of primer complete all as specified and directed.
M&L Preparation of new/old untreated surfaces of Mangalore pattern tiles including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots, applying two coat of acrylic emulsion exterior paint over a coat of primer all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing ) and rubbish off the premises complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed.
Taking down wooden chowkets not exceeding 1.5 sqm including shutters (without taking of the shutters from the frame) complete all as specified and directed.
All as per items 23 here in before but area exceeding 1.5 Sqm and not exceeding 4 Sqm complete all as specified and directed.
M&L Coloured Vitrified tile of size exceeding 0.42 sqm but not exceeding 1.0 sqm set and jointed in neat cement slurry and pointed in coloured cement to match over and including screed bed 15 mm thick in cement mortar 1:6 as in flooring complete all as specified and directed.
M&L Digital glazed ceramic coloured tiles of size 600mm x300mm X7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including rendering 10mm thick in cement mortar 1:4 as in vertical surface such as dado, skirting etc complete all as directed and specified
M&L White colour three track sliding window complete all as per manufacturer's direction and following specifications all as directed:- 1. M&L for UPVC Window frame shall be made of PVC material confirming to IS 10151 the door frame shall be made of extruded UPVC section having over all dimension of 100 x 55mm having wall thickness 2mm + 0.2mm. 2. Corners of wall frame shall be shall be jointed by MS galvanized brackets mitred and plastic welded the hinge side vertical outer frame shall be reinforced with galvanized MS tube of wall thickness 1mm + 0.1mm and the tie rod shall be provide at the bottom of the frame. 3. The profiles should be three chamber system which shall provide high insulation properties. 4. All the hardware like friction stays, handles should be screwed with self tapping screws. 5. Glazing system should be glazed with 5mm thick plain glass fixed/louvers in window frame and all as per manufacturer's instructions and as directed. 6. Each window shutter to be provided with one 150 mm long powder coated aluminium handle, two 3D hinges and two 150 mm powder coated aluminium tower bolts. 7. Stainless steel wire mesh 0.36mm nominal dia and average width of apertures 1.40mm shall be provided in wire mesh shutters
M&L UPVC door white colour complete all as per manufacturer's direction and following specifications all as directed:- 1. The profile for construction of UPVC Door will be of overall size 60x58 mm with wall thickness 2.7 + or - 0.2 mm extruded sections. 2. The corners will be plastic welded. 3. The hinge side vertical outer frame shall be reinforced with galvanized channel of wall thickness 1.2 mm. 4. The door will be fixed to walls using 8 mm dia 80 mm dia MS screws minimum 3 nos on each side. 5. The top portion of door shall be provided with plain glazing of 6 mm thick fixed to door shutter with UPVC standard beadings of 24.5 x 16 mm of 2 mm thick. 6. The bottom portion of door for 1 m height will be provided with UPVC hollow board not less than 6 mm thick. 7. The door shall be provided with:- (a) Mortise lock of brass size minimum 100mm four lever with two keys as per manufacture's specification. (b) Two nos of fan light pivot size 170mm on one shutter. (c) 03 nos of 3D hinges on each shutter. 8. All the fittings shall be provided with using self tapping screws. Note: The entire fixing will be done as per manufactures instructions and specification and as directed by Engg in charge.
M&L UPVC partition/Ventilators complete all as per manufacturer's instructions and following specifications all as directed:- 1.UPVC partition frame shall be made of material confirming to IS 10151 of extruded UPVC section having over all dimension of 65x55 having wall thickness 2mm + 0.2mm. 2. Corners of frame shall be jointed by MS galvanized brackets mitred and plastic welded. 3. The profiles should be single chamber system which shall provide high insulation properties , 4.Glazing shall be 6mm thick frosted glass fixed in frames with appropriate beading as per manufacture's specification. 5. The bottom portion of partition for 1 m height and above 2.1m height will be provided with UPVC hollow board not less than 6 mm thick.
M&L Polished Granite stone slab flooring 16-18 mm thick any colour/shade machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing; rounding edges as required laid over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge.
S&F Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors ladders framed balusters; walk ways railings ; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
Dismantling wall and ceiling boards (fiber, pulp, insulation etc.) any thickness, including cover fillets and suspension grid etc., complete all as specified and directed.
M&L Modular false ceiling systems in multi level with GRG (Glass reinforced gypsum ceiling tiles) having micro look teglar edges of 12mm thickness of size 595mmx595mm GRG ceiling tiles shall have a humidity resistance of upto 95% with NRC level of 0.6 and fixed with suspension system (Grid) The size of the same is 15mm x 32mm, The galvanised iron sheet of thick 0.30mm used in the manufacturing of gird is zinc coated for preventing corrosion. The main runners are hung from the soffit with help of GI wire hanger complete with installation all as manufacturers instruction and as directed.
S&F Gypsum board ceiling 12 mm thick using GI frame work including plaster of paris decorative type cornices etc., any shape as approved by GE and applying two coats of plastic emulsion paint over a coat of primer etc, complete as per manufacturer's instruction and as directed by Engr-in-Charge.
M&L Precast block masonry with solid blocks of cement concrete 1:3:6 type C1 (using 20 mm graded stone aggregate), exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
M&L Walling of squared rubble un coursed well bonded bedded and solidly hearted built in cement mortar 1:4 complete all as specified and directed.
M&L Keyed pointing to squared rubble or coursed or uncourced or brought upto courses in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L Rendering 15 mm thick on fair faces of brick work in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L Rendering 15 mm thick on fair faces of brick work in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L Preparing new surface of steel and iron exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L Preparation of new plastered wall surfaces and applying two coats of high gloss emulsion paint over a coat of primer with brush/roller over and including one coat of acrylic wall care putty complete all as specified and directed.
M&L Complete removal of existing treatment from old treated surfaces of wall and applying two coats of high gloss emulsion paint over a coat of primer with brush/roller over and including one coat of acrylic wall care putty complete all as specified and directed.
M&L Preparation of new surfaces of external walls and applying two coats of Anti-fungal exterior emulsion paint over a coat of exterior wall primer over and including one coat of external wall care putty complete all as per manufacturer's instruction and as directed by Engr-in-Charge.
M&L Complete removal of existing treatment on wall by scrapping, washing, rubbing down and stopping of distempered and painted surfaces and applying two coats of Anti-fungal exterior emulsion paint over a coat of exterior wall primer over and including one coat of external wall care putty complete all as per manufacturer's instruction and as directed by Engr-in-Charge NOTE FOE ITEM NOS 42 TO 45:- The work shall be carried out by authorised applicators of manufactures of paints.
S&F Locker of size 1980mm x 916mm x 452mm and legs of size 453mm x 125mm x 125mm, 8 units of size height 451mm, width 456mm and depth 450mm of each unit. The doors shall be made with1mm thick powder coated MS CRCA sheet and sides, top, bottom, back and legs are made of 0.9 mm thick MS CRCA sheet conforming to IS 513-1986. each unit having locking arrangement with 6 lever lock with duplicate keys and applying powder coated paint over zinc phosphate pretreatment and reinforced with metal stiffeners with spot welded and fixing to wall with 6 Nos of 8mm dia 100mm long anchor fastener bolt, nuts and suitable washers all as directed by Engineer in Charge
S&F 15mm thick white ceramic marker writing board of size 1200mm X 900mm frame of the board made of durable aluminium and corner plastic with hanging arrangement complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level).complete all as specified and directed.
M&L 30 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate finished even and smooth with using extra cement and mixed with 3% water proofing compound as in roof padding/leveling course, Krebs or chamfered on edges all as specified and as directed. Note : WPC shall be measured and paid separately.
M&L 10mm thick screed bed or bedding layer in CM 1:3 mixed with 3% water proofing compound for laying floor finishes complete all as specified and as directed. Note : WPC shall be measured and paid separately.
Supply only Integral water proofing compound complete all as specified and directed.
M&L APP modified polymeric membrane 4 mm thick and weighing not less than 4.50 kg/sqm reinforced with known woven polyester matt black finished weighting not less than 100 gm/sqm having softening point not less than 140 degree Celsius longitudinal tensile strength not less than 300 N/sqcm, side lap and end lap 10 cm and 15 cm with torch application of membrane, over compatible primer at the rate of 0.40 ltr/sqm and finishing with bituminous aluminium paint applied at the rate of 0.10 kg/sqm and finished all as per manufactures instruction complete all as specified and directed. Note : The quoted rate shall be inclusive of removing and refixing tanks & tank stands for treatment. The work shall be carried out by authorised applicators of manufactures.
Demolition of reinforced Cement Concrete of any description and in any position (as in shelf, chimney, chajja etc) not otherwise specifically provided for complete all as specified and directed.
M&L Reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregates as in slabs supported on walls, beams and columns in floors like including necessary form work, complete all as specified and directed.
M&L TMT Bars 6 to 8mm dia & over, cut to length bent to shape, required, including cranking bending and fixing to beam and shelves slab, chajja complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks, 1000 Ltr capacity, cylindrical, vertical with closed top, hoisted and fixed in position including 20 mm dia ball brass valves, high pressured with polyethylene float and fly hut complete, screwed for iron pipe all directed as in repairs complete all as specified and directed.
M&L 18/19mm thick pre laminated particle board, interior grade prelaminated on both sides with decorative choice laminations fixed with screws to timber frame work as in kitchen cabinet/ ward robe including 6mm thick teak wood lipping complete all as specified and directed.
S&F 30mm over all width of hasp (when open), continuous piano hinges, mild steel bright finish or electrogalvanished complete all as specified and directed.
S&F Brass handles, cast type, polished bright size 75mm complete all as specified and directed.
S&F Antique type curtain rods resting on brackets fixed to wall with suitable screws and Sphere shaped decorated end dooms all as per approved design/colour/pattern fixed complete all as specified and directed.
Taking down Aluminium door/ partition including glass / particle board complete all as specified and directed.
S&F in Powder coated aluminium door/ windows/ partition etc. with one or more rebates using suitable size standard aluminium sections including jointing cleat, glazing clips, rubber neopreone packing including necessary accessories like handles, hinges etc complete all as specified and directed .
Refixing only aluminium door/ windows/ partition etc. with one or more rebates using old aluminium sections, glass, partical board, etc including jointing cleat rubber beading and accessories for fixing etc complete all as specified and directed .
S&F 12 mm thick prelaminated one side, interior grade, prelaminated one side decorative choice lamination & other side balancing white lamination, fixed to aluminium/ timber frame all as specified and directed.
S&F 5.5 mm thick sheet glass, ordinary quality and glazing with oil putty/ Aluminium rubber beading in squares exceeding 0.5sqm in each pane complete all as specified and directed
Dismantling structural steel work including doors, gates but excluding framed truss etc. and make the damage area good as existing including finishes to the satisfaction of Engr-in-Charge all as specified and directed.
M&L Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections all as specified and as directed
M&L Cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
Taking down old unserviceable copper/aluminium point wiring (light, fan, socket or power) complete, including fixture & fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit & making good the disturbed surfaces of walls, floors, etc., complete all as specified and directed.
Taking down old sub-main wiring including fixture and fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good the disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down old Main Switches / MCB DBs including MCBs etc. removing materials to store for keeping in safe custody or for taking credit and making good the disturbed surfaces of walls, floors, etc complete all as specified and directed.
M&L Concealed point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including non-metallic PVC rigid conduit, medium grade with all fittings and accessories ISI marked including provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLS, ISI marked as earth continuity conductor (green in colour) and including fixing of modular metal flush boxes of appropriate size and thickness fixed flush to wall for mounting switch, sockets etc. with including cutting chases for conduits and sinkings for modular boxes and making good the disturbed surfaces, matching to the existing one etc. complete all as specified and as directed for the following:-
(a) One Light/Exhaust fan point controlled by one switch 5/6 Amps
(b) One switch socket out let point 5/6 Amps on independent board
All as per Item 72 above but with FRLS PVC insulated copper conductor cable of size 2.5 Sqmm and 2.5 Sqmm for earth continuity conductor green in colour for 16A switch socket complete all as specified and directed. NOTE FOR 73 & 75: supply and fixing of modular metal flush boxes shall be measured & paid separately.
M&L Sub-main wiring 2 runs of 4.0 sqmm and one run of 4.0 sqmm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked complete all as specified and as directed. Note:- (a) 03 runs of copper conductor & 01 run of PVC rigid conduit (Medium grade) will be considered as one run.
M&L Sub-main wiring 2 runs of 6.0 sqmm and one run of 6.0 sqmm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked complete all as specified and as directed. Note:- (a) 03 runs of copper conductor & 01 run of PVC rigid conduit (Medium grade) will be considered as one run.
M&L Sub-main wiring 4 runs of 6.0 sqmm and two run of 6.0 sqmm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked Complete all as specified and as directed. Note:- (a) 06 runs of copper conductor and one run of PVC rigid conduit (Medium grade) will be considered as one run.
S&F Modular switch, one way, 6 Amp, 1 Module, 240 volt, ISI marked complete all as specified and as directed Cat No: “ACVSXXW061, Make: Verona of Crabtree or other make given in list of manufacturer.
S&F Modular switch, one way, 16 Amp, 1 Module, 240 volt, ISI marked complete all as specified and as directed ACVKCWW161, Make: Verona of Crabtree or other make given in list of manufacturer.
S&F Modular shuttered socket outlet 5 Pin, 6 Amp, 2 Module, 240 volts, ISI marked complete all as specified and as directed Cat No: “ACVKSWW065, Make: Verona of Crabtree other make given in list of manufacturer.
S&F Modular shuttered socket outlet 3 Pin, 6/16 Amp, 2 Module, 240 volts, ISI marked complete all as specified and as directed. Cat No: “ACVKCWW163 Make: Verona of Crabtree or other make given in list of manufacturer.
S&F Modular metal flush box concealed suitable for fixing switches/sockets of 2 modules complete all as specified and directed.
S&F Modular metal flush box concealed suitable for fixing switches/sockets of 3 modules complete all as specified and directed.
S&F Modular metal flush box canceled suitable for fixing switches/sockets of 4 modules complete all as specified and directed.
S&F Modular metal flush box concealed suitable for fixing switches/sockets of 6 modules complete all as specified and directed.
S&F Modular cover plate suitable for fixing switches/sockets of 2 modules complete all as specified and directed.
S&F Modular cover plate suitable for fixing switches/sockets of 3 modules complete all as specified and directed.
S&F Modular cover plate suitable for fixing switches/sockets of 4 modules complete all as specified and directed.
S&F Modular cover plate suitable for fixing switches/sockets of 6 modules complete all as specified and directed. NOTE : The make/model of modular metal flush boxes & modular cover plates shall be same as that of modular switches & sockets.
S&F Ceiling rose surface PVC/ Polycarbonate, Isolated body with face Bakelite 63.5 x 25mm, two/three terminal complete all as specified and directed.
S&F, IP >= 20, Class I, recess mounting LED square shape slim ceiling light fitting 42 W or next higher rating, CRI >= 80, CT >= 5700 K, suitable for 600 x 600 mm (approx dimensions) modular Grid/POP/Gypsum ceilings, integrated type, with high efficiency electronic driver, surge suppressor of 2 KV or more & high brightness LEDs, luminaire efficacy > 95 lumens/Watt, power factor >= 0.90, operating range – 140 to 270 V, 50 Hz with suitable fixing arrangement complete with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size complete all as specified and directed. MAKE:- Cat No : PLUTONEO2X2PLR42WLED857S of make Havells or other make given in list of manufacturer.
S&F, IP >= 20, Class I, LED light fitting 1 x 20 W (4 FT), CRI >= 80, CT >=5700 K, wall / surface mounted, integrated type with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Cat No : ENDURALINEARNEOBS20WLED830SPCWH of make Havells or other make given in list of manufacturer.
S&F, IP >= 20, Class I, LED light fitting 1 x 10 W (2 FT), CRI >= 80, CT >=5700 K, wall / surface mounted, integrated type with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Cat No : ENDURALINEARNEOBS10WLED865SPCWH of make Havells or other make given in list of manufacturer.
Supply, install, testing & commissioning of Exhaust fan, PVC body with automatic back shutter louvers 250 mm sweep, 1280 RPM or more, Air Delivery not less than 860 CMH, single phase, 240 Volts, AC, 50 Hz and connecting up complete including louvers and provision of cable 3/2 core of suitable size from ceiling rose to fan in flexible hose and making of suitable sized hole in the wall/existing window/ventilator etc. for fixing of the exhaust fan & making good the disturbed surfaces (if any) including taking down of unserviceable exhaust fan complete all as specified & as directed. Cat No: “Ventil Air-DX white of Make: Havells or other make given in list of manufacturer. Note :- (i) The cost of making hole in walls/other surfaces & making good the disturbed surfaces incl any framework/cement work/wood work/welding work etc. required for proper fixing of the exhaust fan & matching to the existing surface is deemed to be included in the unit quoted rates.(ii) Old unserviceable Exhaust fans should be handed over to MES stores.
Supply, install, testing & commissioning of wall fan 300 mm sweep, Air Delivery not less than 34 CMM, heavy duty, single phase, AC, 230 Volts, 50Hz with features such as motor over-heat auto protection, oil reservoir lubrication for better reliability & longer life, powerful motor for High Air Delivery, pivot arrangement for tilting, jerk free & uniform oscillation, pull chord switch for speed regulation, powder coated guard with ribs etc. and connecting up complete including provision of cable 3 core of size 0.75 Sqmm from ceiling rose to fan including writing of MES Number 2.0 cm height with synthetic enamel paint complete all as specified & as directed. Cat No/Model: “D’Zire of Make Havells or other make given in list of manufacturer. Note :- (i) The cost of making fixing arrangement in walls/other surfaces & making good the disturbed surfaces incl any framework/cement work/wood work/welding work etc. required for proper fixing of the wall fan & matching to the existing surface is deemed to be included in the unit quoted rates.
Supply, install, testing & commissioning of Exhaust fan, Heavy duty Metallic body with automatic back shutter louvers 450 mm sweep, 1400 RPM or more, single phase, 240 Volts, AC, 50 Hz and connecting up complete including louvers and provision of cable 3 core of size 0.75 Sqmm from ceiling rose to fan in flexible hose including taking down of old fan and making of suitable sized hole in the wall for fixing of the exhaust fan & making good the disturbed surfaces (if any) complete all as specified & as directed. Make : Havells, Cat No: Turbo Force SP or other make given in list of manufacturer. Note :- (i) The cost of making hole in walls/other surfaces & making good the disturbed surfaces incl any framework/cement work/wood work/welding work etc. required for proper fixing of the exhaust fan & matching to the existing surface is deemed to be included in the unit quoted rates
S&F energy saving high power LED building security light of 25W made up of pressure die cast aluminum housing with embedded PC cover having TOP Opening separate driver compartment with IP66 protection including GI pipe bracket made out of 40mm dia light grade pipe of length 1.2 Mtrs, bend to shape 120-130 degree and MS clamps made out of 25x3mm flat iron 2 Nos including nut and bolts for fixing the bracket and making connections in flexible conduit all as directed. Make: Cat no ENDURAPEARLSL25WLED757SASYTOPC Endura pearl of Havells or other make given in list of manufacturer.
S&F Workshop table lamp the Stylish Raylite come with an adjustable angle suitable for B-22 LED 10 to 15W all as specified and directed. Make: Havells Cat no LHFXBZNNTN1W013 orother make given in list of manufacturer.
S&F LED lamps of 15W, 6500K with B-22 base cap all as directed Cat No: LHLDDEHEML8R015 of Make : Havells or other make given in list of manufacturer.
S&F Indoor hanging light LED 12W White light, decorative type including provision of cable 3 core of size 0.75 Sqmm complete all as specified and directed. Make: Cat No LSL207 of Luker or other make given in list of manufacturer.
S&F Modular RJ 11 Tele Jack double with shutter, 1M complete all as specified and directed. Cat No: “574846 of Make Legrand or other make given in list of manufacturer.
S&F Modular TV Co-Axial Socket, 1M. complete all as specified and directed. Cat No: “574851 of Make Legrand or other make given in list of manufacturer.
S&F Modular RJ 45 Data Outlet Cat 6-UTP, 2 M. complete all as specified and directed. Cat No: “574850 of Make Legrand or other make given in list of manufacturer.
M&L PVC insulated telephone cable all as conforming to TEC specification G/WIR06/02, unarmoured 0.5 mm ATC, 5 Pair with and including concealed PVC rigid conduit medium grade including connection and making good the disturbed surfaces complete all as specified and as directed. Cat No: “WHTTATEA5P40 of Make: Havells or other make given in list of manufacturer.
M&L for Co-Axial TV cable made up of electrolytic grade solid annealed copper conductor, JF, Al foiled, Al wire braided & of type RG 6 (foam) with and including concealed PVC rigid conduit medium grade including connection and making good the disturbed surfaces complete all as specified and as directed. Cat No : WHOJTTKARG06 of make Havells or other make given in list of manufacturer.
Supply, Installation, Commissioning and Testing of Maintenance Free Earthing system comprising of the following:-
(a) Copper Bonded Steel Earth Rod of 3 meter length and 14.2 mm diameter. Auger a hole of diameter 3 inch and 9 feet depth in the soil, placing the Earth rods in to the augured hole, hammering the rods to 1 feet depth, removing excavated material. complete all as specified and as directed by Engr-in-Charge. Brief features/ specifications of CBSE Rod is as follows: aa) The outer surface must be molecularly bonded with uniform layer of 250 micron Copper, 99.9% pure electrolytic copper coating. ab) Nickel interface must be provided between the copper and steel to avoid the galvanic corrosion. ac) Must be capable of withstanding fusing current of 20 KA @ 1 Sec ad) Earth rod must be in compliance with IEC 62305- 2, NBC 2010 and IEEE 80. Rod should be tested as per IEC 62561- 2 standard ae) Tensile strength greater than 80000 PSI on 12 mm. af) High resistance to corrosion. ag) Material category number should be UL listed, Manufacturer Make, Part No and UL mark should be printed in each rod. Make:- ERICO Cat Part No:CODE615800 or other make given in list of manufacturer.
Ground Enhancement Material (GEM), Per Bag -11.33 Kgs, Conforming to IEC 62561-7 Standard, Premixing the GEM into slurry form using water (Not more than 5L to 6L per bag), Pouring the GEM mixture in the augured hole and filling complete all as specified and as directed. Brief features/ specifications of the same is as follows: ba) Must be carbon based superior conductive material. bb) Resistivity must be less than 2 Ω-cm. bc) Must not cause corrosion to copper when in contact. bd) Must not expand or experience any shrinkage once set. be) Must not depend on the continuous presence of water / moisture / salt to maintain its conductivity. bf) Must not decompose or leach out with time. bg) Must not contain hazardous chemicals as per IEC 62561-7 standard, TCLP Tested. bh) Flexural and possess compressive strength as per relevant standard. bj) Sulphur content must be less than 2%. bk) Must be inline with IEEE 80 clause 14.5.d. bl) Corrosion test shall be conducted on the material under both aggressive and non aggressive conditions. bm) Installation Instruction and Material DATA sheet should be printed in each package. Make:- ERICO Cat Part No: GEM 25A- 25-1lb or other make given in list of manufacturer.
Readymade PVC Heavy duty earth chamber (250 mm Dia, 260 mm height) with round cover and minimum 5 ton load bearing capacity, marking earth resistance value on it in painting complete all as specified and as directed. IMPORTANT NOTES ON ITEM NO. 107 (1) Design / drawing / BOM of the complete Chemical Earthing system showing the layout & dimensions is to be obtained from OEM strictly keeping in view the actual ground/site requirement & the same is to be got approved from Engr-In-Charge & GE before placing final order to the manufacturer. (2) Anything missed out in the technical specifications but technically required for efficient working of the earthing system is deemed to be included in the quoted rates. (3) The entire installation & testing work is to be got done from the OEM or their auth Rep/Sister Concern/Channel Partners only. (4) The quantity of earth conductivity enhancing compound indicated above is generally for normal/good soils. In case the soil resistivity is high, the quantity should be increased & cost of the same is deemed to be included in the unit quoted rates. 5) On completion of the complete work/job the Contr is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Dept till the results are satisfactory.
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25mtrs deep below ground level) with top edge of plate not less than 1.5mtrs below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point on completion with and including 15mm bore medium grade GI protection pipe (up to 7.5mtr long) for earth and 20mm GI medium grade for watering including PCC chamber pit & cover with suitable lifting hooks, with funnel, wire mesh, common salt, charcoal filling, necessary excavation and earth work in any type of soil complete all as specified including taking out the existing unserviceable earthing accessories. Note:- On testing after completion, if the desired earth resistance is not obtained the earthing shall be redone at no extra cost till the entire satisfaction of Engr-in-Charge.
S&F 32 x 6 mm galvanised iron strip as earth continuity conductor including connection complete with the help of chromium plated washers, nuts etc. complete all as specified and directed.
S&F 40 mm bore GI pipe, light grade fixed on walls, floors, laid in under ducts/culverts etc. for protection of earthing lead complete all as specified and directed.
S & F SPN DB, 8 Way IP43, IK09, Metal double door type 240 volts fitted with busbar and blanking plates, neutral link and making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed. Cat No: “DBSPN0008DD” of Make L&T or other make given in list of manufacturer. Note:- (i) The cost of making good the disturbed surfaces is deemed to be included in the unit quoted rates.
S & F SPN DB, 12 Way IP43, IK09, Metal double door type 240 volts fitted with busbar and blanking plates, neutral link and making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed. Cat No: “DBSPN012DD” of Make L&T or other make given in list of manufacturer. Note:- (i) The cost of making good the disturbed surfaces is deemed to be included in the unit quoted rates.
S&F MCB, SPN, C-Series, 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA complete all as specified and directed.
S&F MCB, SP, C-Series, 240 Volts of capacity 6-32 Amps as ordered with breaking capacity 10 KA. complete all as specified and directed.
S&F MCB, DB, TPN, 4 ways, DOUBLE DOOR, IP-54, Ik-09 with metal door, rated bus bars, earth bar, neutral links complete including blanking plates as required & fixed flush to wall/other surface complete all as specified and as directed. Cat No: “DBTPE00454 of Make L&T” or other make given in list of manufacturer.
S&F MCB, TPN, 10KA, 415V, "C" curve, 40 A, ISI marked complete all as specified and directed.
S&F MCB, TPN, 10KA, 415V, "C" curve, 63 A, ISI marked complete all as specified and directed.
Supply, install, commissioning & testing of ATS Panel "out-door type" of size 1200 mm (height) x 900 mm (breadth) x 600 mm (depth) (minimum dimensions) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal/control wiring with appropriately sized/rated copper wires incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) complete all as specified & as directed with & incl the following accessories :
PROVISION FOR CABLE ENTRY: The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands, clamps etc. matching the existing LT cable sizes.
INCOMING : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 100 to 125 A - 02 Nos. Cat No: “CM90642OOLO of Make L&T” or techno-commercially equivalent (b) Compact Enclosed ATS (Automatic Transfer Switch) suitable for outdoor mounting & I-O-II operation, 4 Pole, 125 A, confirming to IEC 60947-6-1 - 01 No complete with following features/specifications : (i) Double-Break Contact System offering High Short-time Withstand. (ii) Ample Space for Cable Termination. (iii) Ease of Generator Control (ON-OFF, Cooling Cycle Self-Test). (vi) Adjustable Time Delay (0.1 Sec to 3 Hrs). (vii) Suitable for 3-Phase as well as 1-Phase sources. (viii) Protections - UV/OV, Phase Sequence, Single Phasing, Frequency. (ix) Terminal Shrouds, Phase Barriers & Source Separator etc. Model - Enclosed ATS, Frame 2, Type - 125 A, Cat No CK90161BSOO of make L&T or techno-commercially equivalent (c) SPD (Surge Protection Device) - 01 Nos confirming to IEC 61643-11 complete with following features/specifications : (i) Type : 1 + 2 (Protection against Direct & Indirect Lightning Surges) (ii) Maxm Discharge Current : Imax upto 100 KA. (iii) Configuration : 3P+N. (iv) Module - 4 (v) Spare Cartridges - 03 Nos. (Cat No AUSC121PN100) Model - SPD, Type - 1+2, Cat No AUSP123PN100 of make L&T or other make given in list of manufacturer.
OUTGOINGS : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 100 to 125 A - 02 Nos (1W+1S). Cat No : CM90642OOLO of Make L&T or other make given in list of manufacturer.
Supply, install, commissioning & testing of LT control panel board "out-door type" of size 1200 mm (height) x 1200 mm (breadth) x 500 mm (depth) (minimum dimensions) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal/control wiring with appropriately sized/rated copper wires incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) complete all as specified & as directed with & incl the following accessories :
BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Aluminium 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes.
INCOMING : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 160 to 200 A - 01 Nos. Cat No : CM90642OONO of Make L&T or other make given in list of manufacturer. (b) Onload changeover switch, open-execution modular construction type, confirming to IS/IEC 60947-3, rated current 200 A, 415 V, 4P - 01 Nos. Cat No : CO22000OOOA, Type CO2-200 of make L&T orother make given in list of manufacturer.
OUTGOINGS : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 25 KA & of rating 80 to 100 A - 03 Nos (2W+1S). Cat No : CM91712OOKOOG of Make L&T or other make given in list of manufacturer.
NOTE FOR ITEM NO 118 & 119 : 1) Design / drawing / BOM of the Panel Board including all accessories showing the dimensions is to be obtained from the Manufacturer / Supplier & is to be got approved from the Engr-In-Charge & GE before placing final order to the manufacturer. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
M&L Earthing complete with GI plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to GI strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC chamber & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip for protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and directed.
S&F 80mm bore, GI pipe light grade on walls, floors under ducts/culverts etc. for protection of earthing lead complete all as specified and directed.
M&L Cutting the existing hard standing/PCC/WBM road at a depth not less than 45 cm and 25 cm in width for passing of cable through GI pipe, returning filling in, complete including finishing the surfaces by providing cement concrete 1:2:4 type B-1 with 20 mm grade aggregate upto 25 cm, finishing to a uniform smooth surface complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 70 sqmm, 3.5 core complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of pipe and getting out in hard/dense soil complete all as specified and directed.
Removing of excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L Providing sand cushioning for protection of UG cable in trenches with dry (coarse) sand approved quality including filling, spreading and punning down to desired thickness complete all as specified and directed. Note:- Only punned thickness of sand filling shall be measured and paid
Supply and laying sub class "B" bricks in trenches for protection of UG Cable complete all as specified and directed.
UNIQUE INDIA CONSTRUCTIONS
SRI VIGNESH BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .