| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹61.2 LRejected-Finance 180 10 GALI NO 10 NEAR TRIVENI MANDIR HARPAL NAGAR BHATTI ROAD BATHINDA PUNJAB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | 1st | Rejected-Finance Due to bidder quoted higher rates | |
| 2 | 2nd₹65.3 L+₹4.0 L (6.60%)Rejected-Finance 22236 B SHANT NAGAR NEAR CITY CABLE OFFICE BATHINDA DISTT BATHINDA | BATHINDA | BATHINDA | PUNJAB | 2nd | Rejected-Finance Due to bidder quoted higher rates | |
| 3 | 3rd₹65.5 L+₹4.3 L (6.99%)Rejected-Finance NOT SPECIFIED | 3rd | Rejected-Finance Due to bidder quoted higher rates | |
| 4 | Rejected-Technical | - | Rejected-Technical Non Responsive |
Tender Value
₹49.7 L
EMD Value
₹99,500
Closing Date
4 Nov 2019, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer DWSS Moga
Room No. 313 3rd Floor Jhelum Chenab Complex DAC Moga
Construction of 2 No. New RCC OHSRs Group-12 in place of Non existing/non-functional OHSRs in villages Manu Ke and Thraj Block Bagha Purana Distt Moga
2019_WSS_38126_1
OHSR/2019/G12
Open Tender
Construction Works
Item Rate
180 days
Village Manu Ke and Tharaj
Please refer Tender documents.
8 documents required · 8 mandatory
₹1
TIA
₹99,500
11 Feb 2020
24 Sept 2019
5 Nov 2019
24 Sept 2019
4 Nov 2019
24 Sept 2019
90 days
Amount
Construction of 02 No New RCC OHSRs of various Capacities with sill level and FSL as given below, from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing DI K-9 D/F expansion joints conforming to (IS-9523 with latest amendments) or latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, Conforming (IS-9523 with latest amendments)and DI K-9 D/F sluice Valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow DI K-9 double flanged pressure pipes centrifugally cast as per IS 8329 with latest amendments duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel & painting of all complete shall be included in cost & P/F aluminum ladder inside, steel ladder outside tank of the OHSR including testing of soil bearing capacity complete in all respect as per specifications. (The specifications & drawing are based on safe bearing capacity of soil is not less than 8.75 tone per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per Sqm, The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Premium including overflow haudi, including providing & fixing Water Level indicating system and Construction of Plinth protection around OHSR with masonry toe wall with 40 mm thick CC 1:2:4 on top over 100 mm thick CC 1:8:16 & inside earth filling within lead of 5 km, including prov. & fixing Rising main and Delivery main to be connected with existing pipeline complete in all respects in following villages :
Village Manuke Zone-I (OHSR of capacity 200CUM, Sill level = 23.50M and F.S.L. = 28M)
Village Tharaj (OHSR of capacity 150CUM, Sill level = 24.50M and F.S.L.=29M)
Providing, Stringing out PVC pipes ISI Marked as per ISI-4985 casting along the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing complete as per specifications including excavation for less than 3 mtr street width
200mm o/d pipe of 10 kgf./sqcm (For Vill Tharaj)
250mm o/d pipe of 10 kgf./sqcm (For Vill Manu Ke)
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in - charge)
200 mm I/d sluice valves flanged (For Vill Thraj)
250 mm I/d sluice valves flanged (For Manu Ke)
Providing, Fixing & jointing Cast Iron Surface box for Sluice Valve, Air Valve, Fire hydrant etc. including all carriages complete 4 No. with Each 3kg I.e (4 x 3 = 12 kg)
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department 4 No. With each of Size (0.9m x 0.9m)
Deduct credit of old sluice valves Lump sum
Providing, Stringing out PVC pipes ISI Marked as per ISI-4985 casting along the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing complete including excavation as per specifications for less than 3 mtr street width
200mm o/d pipe of 6 kgf./sqcm ( Village Thraj)
200mm o/d pipe of 6 kgf./sqcm ( Village Manuke )
DALJIT SINGH KOHLI CONTRACTOR
RAVINDER SINGH CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .