| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder. | |
| 2 | L2₹32.2 L+₹4.5 L (16.1%)Rejected-Finance 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L2 | Rejected-Finance Not Lowest. |
Tender Value
₹3.2 L
EMD Value
₹64,000
Closing Date
8 Nov 2021, 6:00 pmClosed
GE Kamptee
Garrison Engineer Cantt Area Kamptee 441001
REPAIR/REPLACEMENT OF DG SET, REPAIR/REPLACEMENT OF AMF PANEL AND CONNECTED ITEMS AND REPAIR/REPLACEMENT OF STREET LIGHT ,PAINTING STEEL TUBULAR POLE CONNECTED ITEMS OF DISTRIBUTION SYSTEM IN KAMPTEE AND NAGPUR AREA UNDER GE KAMPTEE.
2021_MES_481575_1
8336/E8
Open Tender
Civil Works
Item Wise
180 days
Kamptee and Nagpur
Class D, Cate B (i)
7 documents required · 7 mandatory
₹500
Yes
GE Kamptee
₹64,000
Yes
8 Dec 2021
13 Oct 2021
10 Nov 2021
13 Oct 2021
8 Nov 2021
25 Oct 2021
Amount
S&F in replacement automatic voltage regulator (AVR) suitable for the DG Set 25 to 125 KVA complete all as specified and directed. Make:- Kirloskar/Mahindra/Ashok leyland.
S&F in replacement automatic voltage regulator (AVR) suitable for the DG Set 200 KVA . complete all as specified and directed. Make:- Kirloskar/Mahindra/Ashok leyland.
S&F in replacement MNX 185 power contactor for DG set, standard coil voltage 110V,220V,240Vand 415 V,50 HZ complete all as specified and directed. Make - L&T/ABB/Legrand.
S&F in replacement MCX03 contractor 32 Amp 4 pole 240 V suitable for DG set complete all as specified and directed.
S&F in replacement MCX43 contactor 400 Amp, 240 v suitable for DG set 200 KVA complete all as specified and directed.
S&F in replacement MCX13 contractor 80 Amp 4 pole , 240 V suitaqble for DG set complete all as specified and directed.
S&F in replacement MCX32 power contactor for DG for DG set, standard coil voltage 220V,240V and 415 V,50 HZ complete all as specified and directed. Make - L&T/ABB/Legrand.
S&F in replacement unserviceable contactor coil of power contactor MNX 300 voltage 240 v at 50 Hz complete all as specified and directed. Make : L&T
S&F in replacement unserviceable contactor coil of power contactor MNX 95 voltage 240 v at 50 Hz complete all as specified and directed. Make : L&T
S&F in replacement unserviceable contactor coil of power contactor MNX 185 voltage 240 v at 50 Hz complete all as specified and directed. Make : L&T
M&L for taking down unserviceable self starter from DG set of cap 15 to 125 KVA 12V,for complete replacement and refixed to the existing position after rewinding, including replacement of suitable size bearing complete all as specified and directed.
M&L for taking down unserviceable self starter from DG set of cap 200 KVA 12V,for complete replacement and refixed to the existing position after rewinding, including replacement of suitable size bearing complete all as specified and directed.
M&L for taking down old unserviceable Alternator from DG set 15 KVA to 50 KVA, for rewinding of stater, armature and refixed to the existing position after rewindinding, including replacement of suitable size bearing complete all as specified and directed.
M&L for taking down old unserviceable Alternator from DG set 62.5 KVA to 125 KVA, for rewinding of stator, armature and refixed to the existing position after rewindinding, including replacement of suitable size bearing complete all as specified and directed.
M&L for taking down old unserviceable Alternator from DG set 200 KVA, for rewinding of stater, armature and refixed to the existing position after rewindinding, including replacement of suitable size bearing complete all as specified and directed.
M&L for taking down radiator of DG set of capacity from 15 to 62.5 KVA at site and cleanning its fins externaly by air pressure and washed internaly by cleaning agent carefully and fiixing its original position after checking any leakage complete all as specified and directed.
M&L for taking down radiator of DG set of capacity from above62.5 to 200 KVA at site and cleanning its fins externaly by air pressure and washed internaly by cleaning agent carefully and fiixing its original position after checking any leakage complete all as specified and directed.
M&L for Servicing,of 125 KVA DG Set (Installed at MH OT of make Kirloskar) including greasing of nipples, draining of unserviceable engine oil by unscrewing drain plug (Engine oil shall be measeured and paid seperatly in respective item) cap, and other moving parts of engine and alternator as per manufacturer’s instructions opening cleaning and re connecting of battery terminals and apply petroleum jelly, checking of coupling and replace it if required, Checking of engine oil leakage if any by replacing gasket, tightening of all nuts and bolts etc, removing radiator completely and cleaning as per manufacturer instructions and refitting the same , check the tightness of fan belts if found loose to be tightened. draining of water accumulated in filter or separate in fuel line including complete fuel tank drying and cleaning re filling of drain out fuel, checking of all electric connections in AMF & LT panel board , switches and contactors etc, checking of free rotation of fly wheel/ shaft of generator and testing to the satisfaction of Engr-in-Charge complete all as specified and directed.
All as per item No 18 above but DG Set of 200 KVA installed at MSL Power house, Trg shed Msl, MH Kamptee, Treated water pump house, Radial well Make:- Kirloska/KOEL
All as per item No 18 above but DG Set of 100 KVA installed at Record Office GRC, Auditorium GRC, Station Exchange Make:- Ashok Leyland / KOEL/Mahindra
All as per item No 18 above but DG Set of 62.5 to 63KVA (Installed at Shivaji Pump House,APS Tech Block, Tele Exchange Msl, Msl Gp pump house) Make:- Kirloskar Green/KOEL
All as per item No 18 above but DG Set upto 30 to 40 KVA installed at APS record, NCC OTA , STP Make :- Kirloskar Green/KOEL
All as per item No 18 above but DG Set of 15 to 25 KVA installed at 'R' Line Pump House, 'T' Line pump house, 8 Major pump house Nagpur, Signal centre GRC . Make :- Kirloskar/Kerala Electricals Notes for Item No 01 to 6 above:- Rate quoted by Contractor shall deemed to be included following provisions:- (a) Sufficient/required man power employed for the servicing purpose, T&P used and other petty items such as cotton waste kerosene oil, nuts and bolts etc and any ther minor items. (b) replacement of spares will be measured and paid separately as supply only under respective items. (c) If any defect observed during defect liability period the same shall be rectified by contractor without any extra cost to the Govt. The Contractor shall visit each DG Set prior quoting the rate to know the current status of respective DG Sets. No claim what so ever on this account shall be entertained whether he visit the DG set or not.
S&F in replacement lubricant oil filter element with washer suitable for DG set of capacity from 30 KVA to 125 KVA Make:- Kirloskar (All Make should be as per recommended by manufacturer)
All as per item No 24 above but DG Set of 200 KVA Make:- Kirloskar,
All as per item No 24 above but DG Set of 15 to 25 KVA. Make:- Kerala Electricals Note for item No 18 to 26 above Make shall be of same as existingmake as approved by GE.
M&L radiator coolant concentrate complete all as specified and directed.
M&L in replacement fuel filter element with 'O' ring suitable for DG Sets 100 to 200 KVA Make:- Kirloskar, Mahindra, Ashok Leyland complete all as specified and directed.
All as per item No 28 above but for DG Set of capacity 15 to 63 KVA Make:- Kirloskar, Ashok Leyland, Mahindra, cummins complete all as specified and directed.
M&L for Lubricant oil 15W 40 complete all as specified and directed. Make : Castrol /HP
S&F battery connection copper lead with 200 Amps rated capacity of approved make. complete all as specified and directed.
M&L for distilled water in supplier's packing complete all as specified and directed.
S&F battery terminals as per sample complete all as specified and directed.
M&L for fan belt as per sampler for dynamo/ alternator of suitable sizes for the following DG sets:- DG Set 200 KVA Make: Kirloskar/Cummins/Mahindra/Ashok Leyland
DG set 100 KVA Make: Kirloskar/Cummins/Mahindra./Ashok Leyland
DG set 63 KVA Make: Kirloskar/Cummins/Mahindra./Ashok Leyland
DG set 40 KVA Make: Kirloskar/Cummins/Mahindra./Ashok Leyland
DG set 25 KVA Make: Kirloskar/Cummins/Mahindra./Ashok Leyland
DG set 20/15 KVA Make: Kirloskar/Cummins/Mahindra./Ashok Leyland
M&L for rubber hose pipe complete of suitable sizes for DG sets 15 to 63 KVA complete all as specified and directed.
M&L for rubber hose pipe complete of suitable sizes for DG sets 100 to 200 KVA complete all as specified and directed.
M&L for fuel pipe heavy duty, suitable size for the DG Set 15 to 200 KVA complete all as specified and directed. Make:- Kirloskar/Mahindra/cummins complete all as specified and directed.
M&L for air filter complete of suitable sizes for DG Set 200 KVA complete all as specified and directed.
All as per item No 38 above but for DG Set 125 KVA complete all as specified and directed.
All as per item No 38 above but for DG Set 30 to 100 KVA complete all as specified and directed.
All as per item No 38 above but for DG Set 15 to 25 KVA complete all as specified and directed.
Supply and in replacement fix steel hinges suitable for DG set doors complete all as specified and directed. Make : Kirloskar
S&F in replacement, indicator lamp LED type complete all as specified and directed.
S&F in replacement, ammeter complete all as specified and directed.
M&L for replacement of Digital Meter indicating hrs run ,PF, Voltage, Ampers,Energy consumed complete all as specified and directed.
M&L for replacement of radiator cap with rubber gasket complete all as specified and directed.
S&F in replacement unserviceable canopy door lock of suitable size complete all as specified and directed. Make : As per sample
S&F broken door glases of DG set canopy complete all as specified and directed.
M&L for replacement of Ignition/ Starter Switch with Key complete all as specified and directed.
M&L for replacement of water temperature meter gauge complete all as specified and directed.
M&L for replacement of oil pressure gauge meter complete as per existing specification. complete all as specified and directed.
M&L for replacement of fuel tank cap with locking arrangement. complete all as specified and directed. Make : As per sample
S&F in replacement Battery Lead Acid cell 12 V, 120 AH (for DG set) complete all as specified and directed.
S&F in replacement onload changeover switch 160 A,415 V openexecution sutable for fixing in existing position of LT panel complete all as specified and directed. Make - L&T/Legrand/Havells
S&F inreplacement MCCB 200 Amp 415 V 50 HZ, breaking cap 25 KA with thermal magnetic releases complete all as specified and directed. Make :- L&T/Legrand/Havells
S&F in replacement relay 12 V for AMF panel complete all as specified and directed. Make - L&T/ABB/Legrand.
S&F in replacement battery charger 12 V (SMPS) for DG set complete all as specified and directed.
S&F in replacement controller display suitabe for DG set complete with all accessories and complete all as specified and directed. (Model KG934 of Kirloskar/ L&T/ABB)
S&F in replacemet voltage stablizer 0.5 KVA suitable for DG set complete with all accessories and complete all as specified and directed. .Make - L&T/ABB/Legrand.
S&F in replacemet panel box lock complete all as specified and directed.
S&F in replacement 24 V play relay suitable for DG set complete all as specified and directed.
S&F in replacement NONC suitable for DG set complete all as specified and directed.
S&F in replacement battery charger 24 V ( SMPS) complete all as specified and directed.
S&F in replacement VMR for AMF panel complete all as specified and directed.
S&F in replacement Isolator 63 Amp 4 pole complete all as specified and directed.
S&F in replacemet CT Suitable for DG set 62.5 KVA complete all as specified and directed.
S&F in replacement relay 24 v for AMF panel complete with all accessories complete all as specified and directed.
S&F in replacemet HRC fuse 100 Amp complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of Cables,poles, stay and getting out of excavated material complete all as specified and directed.
S&F Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 120 mm outer diameter and 103.5 mm inner Diameter with IS 14930 (part 2):2001 laid in trenches,wall,floor,pole including bends, sockets and other connected accessories complete all as specified and directed. Make:- Dura. Line/Tijaria/REX.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed.
Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
Taking down unserviceable underground cable, any size from trenches, wall, floor etc and removing from site complete all as specified and directed.
Supply and Laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened,PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 240 sq mm, 3.5 core including testing after laid and jointed with lugs,nuts,bolts,washers complete all as specified and as directed .
Fabrication, Supplying Installing, testing & Commissioning outdoor type feeder pillar box with rain cowl weather / vermin proof, outdoor type, factory made LT panel, from any CPRI approved manufacturer having suitable size working space required for maintenance of panel including necessary incoming & outgoing cable connections, cable glands thimbles of required sizes, made out of MS CRCA sheet 3.00 mm thick for outer shell and 2mm thick for inner shell duly powder coated paint with inner shutter & outer double door with locking arrangement both side openable fixed on 50 x 50 x 5 mm MS angle frame fixed 300mm above groud level & 450mm below the ground grouted in & including PCC (1:3:6) type C1 (using 20mm graded stone aggregate) complete all as specified, directed & comprising of following including refixing existing cables to new panels by proper lugging & cable gland as required. (a) Busbar chamebr for 3 phase & nuetral of capacity 500 Amps alumunium bus bar duly insulated, (b) Multifunctioning meter to measure Voltage, ampere, KWH, PF -1 Nos (c) one set of pilot lamp. (d) Incoming MCCB 320 amps 4 Pole 415 volts 35 KA thermal magnetic setting type- 1 Nos (e) Outgoing MCCB 200 amps 3 pole 415 volts 25 KA thermal magnetic setting - 02 Nos (f) Outgoing MCB 100 amps 3 Pole 415 volts 10 KA thermal magnetic setting- 03 Nos
Fabrication, Supplying Installing, testing & Commissioning outdoor type feeder pillar box with rain cowl weather / vermin proof, outdoor type, factory made LT panel, from any CPRI approved manufacturer having suitable size working space required for maintenance of panel including necessary incoming & outgoing cable connections, cable glands thimbles of required sizes, made out of MS CRCA sheet 3.00 mm thick for outer shell and 2mm thick for inner shell duly powder coated paint with inner shutter & outer double door with locking arrangement both side openable fixed on 50 x 50 x 5 mm MS angle frame fixed 300mm above groud level & 450mm below the ground grouted in & including PCC (1:3:6) type C1 (using 20mm graded stone aggregate) complete all as specified, directed & comprising of following including refixing existing cables to new panels by proper lugging & cable gland as required. (a) Busbar chamebr for 3 phase & nuetral of capacity 500 Amps alumunium bus bar duly insulated, (b) Multifunctioning meter to measure Voltage, ampere, KWH, PF -1 Nos (c) one set of pilot lamp. (d) Incoming MCCB 320 amps 4 Pole 415 volts 35 KA thermal magnetic setting type- 1 Nos (e) On load changeover switch 320 Amps 4 pole 230 volts - 01 Nos (f) Outgoing MCCB 200 amps 3 pole 415 volts 25 KA thermal magnetic setting - 02 Nos
Fabrication, Supplying Installing, testing & Commissioning outdoor type feeder pillar box with rain cowl weather / vermin proof, outdoor type, factory made LT panel, from any CPRI approved manufacturer having suitable size working space required for maintenance of panel including necessary incoming & outgoing cable connections, cable glands thimbles of required sizes, made out of MS CRCA sheet 3.00 mm thick for outer shell and 2mm thick for inner shell duly powder coated paint with inner shutter & outer double door with locking arrangement both side openable fixed on 50 x 50 x 5 mm MS angle frame fixed 300mm above groud level & 450mm below the ground grouted in & including PCC (1:3:6) type C1 (using 20mm graded stone aggregate) complete all as specified, directed & comprising of following including refixing existing cables to new panels by proper lugging & cable gland as required. (a) Busbar chamebr for 3 phase & nuetral of capacity 400 Amps alumunium bus bar duly insulated, (b) Multifunctioning meter to measure Voltage, ampere, KWH, PF -1 Nos (c) one set of pilot lamp. (d) Incoming MCCB 250 amps 4 Pole 415 volts 35 KA thermal magnetic setting type- 1 Nos (e) On load changeover switch 250 Amps 4 pole 230 volts - 01 Nos (e) Outgoing MCCB 200 amps 3 pole 415 volts 25 KA thermal magnetic setting - 01 Nos (f) Outgoing MCB 100 amps 3 Pole 415 volts 10 KA thermal magnetic setting- 02 Nos
Taking down existing unserviceable LT panel any capacity & disconnecting properly all electric supply complete all as specified and as directed.
Supply and fix LED street light luminaires of capcity 60 watts with pressure die cast aluminium housing heat resistance toughened glass, IP 66 protection complete with driver,2.5 sqmm 2 core multistranded Aluminium wire for connection from street light fitting to OH line or junction box,and fixing accessories including taking down old unserviceable fittingcomplete all as specified and directed. Make :- Cat No. LSTP-60-CDL of CG Philips, Bajaj.
Supply and fix LED street light luminaires of capcity 45 watts with pressure die cast aluminium housing heat resistance toughened glass, IP 66 protection complete with driver,2.5 sqmm 2 core multistranded Aluminium wire for connection from street light fitting to OH line or junction box,and fixing accessories including taking down old unserviceable fitting complete all as specified and directed. Make :- Cat No. LSTS-45-CDL-1 of Crompton ,Philips, Bajaj.
S&F in repair LED flood light fittings with pressure die-cast housing and toughened glass cover 100 watt IP65 protection including driver prewired with 3 core multistranded copper wire 1.5 sqmm from fitting to OH conductor / connector and necessary mounting arrangement as required at site complete all as specified and directed. Make:- Crompton/Phillips / wipro/ Bajaj.
Taking down existing street light fitting, any size, any type (HPSV, HPMV, LED, MH, FTL, energy saving street light fitting, T5 multiple FTL 4x14, 4x24 watt, CFL) from pole / wall after disconnecting connection from pole & repair the same by replacing choke, bipin holder, holders, ignitor, unserviceable flexible wire, tube rod, CFL etc & refixing the fitting on pole / wall including connection with overhead lines / connector & testing etc complete all as specified and directed. Note:- Spares will be measured under relevent items as S&F.
S&F LED driver for 100 W LED street light fittings complete all as specified and as directed. Make:- Wipro/ Bajaj/crompton/Surya approved by GE.
S&F LED driver for 150/200 W LED street light fittings complete all as specified and as directed. Make:- Wipro/ Bajaj/crompton/Surya approved by GE.
S&F LED driver for 25/30 W LED street light fittings complete all as specified and as directed. Make:- Wipro/ Bajaj/crompton/Surya approved by GE.
S&F LED driver for 45/60 W LED street light fittings complete all as specified and as directed. Make:- Wipro/ Bajaj/crompton/Surya as approved by GE.
S&F in repair LED Surge protection devices compatible with industrial & Outdoor Led fixture 10 KV Voltage complete all as specified and as directed. Make:- Wipro/ Bajaj/crompton/Surya as approved by GE
S&F in repair for replacement of PVC insulated sheathed twin core flat Multi stranded aluminium coil conductor 2.5 sqmm conductor 1100 volt grade duly made whole in steel tubular poles by using welding or gas cutter torch for entering cable of requird size form loop box to street light fittigs complete all as specified and as directed. Make:- Finolex / Havells / Anchor / Indo Asian.
All as per item No 90 above but of size 4.00 sqmm.
All as per item No 90 above but of size 6.0 sqmm.
Supply and fix in repairs thermoplastic cable entry junction boxes of size 250 x 220 x 135 mm and IP-65 protection level with metric knock out fixed on poles with MS clamps, nuts, bolts and washers including MCB SPN, 5-32 amps, 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs etc., separate (detachable) gland plate, bakelite connector 4 way 20 amp, dust and vermin proof, front door opening with hinges and locking arrangement, complete all as specified and as directed. Make:- Sintex/Hensel
Supply and fixing of Automatic Street light Switch using NATURE SWITCH for automatic switching of street lights based on LUX level of natural light consisting with Sensor (Natural Switch) along with suitanble power contractor , MCB and support terminals , poles/wall mounted type conforming to IP 65 protction enclosures made out of Rust proof, electric shock proof and FR Grade SMC junction box confirming to of capacity 3 Phase 4 wires, three separate contractor including taking down old one and all fixing arrengment all as specified and directed. Make - Kakatiya Energy system
Supply and fixing of Automatic Street light Switch using NATURE SWITCH for automatic switching of street lights based on LUX level of natural light consisting with Sensor (Natural Switch) along with suitanble power contractor , MCB and support terminals , poles/wall mounted type conforming to IP 65 protction enclosures made out of Rust proof, electric shock proof and FR Grade SMC junction box confirming to of capacitySingle Phase 2 wires, contractor, including taking down old one and all fixing arrengment all as specified and directed. Make - Kakatiya Energy system
Supply and fix in repair MCB SP 10-32 Amps, 240 volts, 10 KA capacity complete all as specified and directed.
Supply and fix in repair single phase cotactor rating 40 Amp 220 volt 50 Hz for streetlight automatic switch panel complete all as specified and directed.
Supply and fix in repair Nature Switch-02, 220 volt 50 Hz,upto 3 KW cap for streetlight automatic sensor alongwith pre-dawn switcing off timer ,4-8 hours fixing in panel complete all as specified and directed. Make SWADEEP
Supply and fix in repair MCB SPN 10-32 Amps, 240 volts, 10 KA capacity complete all as specified and directed.
Supply and fix in repair MCB TPN 32/40 Amps, 240 volts, 10 KA capacity complete all as specified and directed.
Supply and fix bracket for street light fittings made out of 40 mm dia GI pipe of light grade 1.5 m long each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 30 x 5 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with two coat of aluminium paint over a coat of red oxide primer and fittings bracket to street light fitting including taking down old unserviceable bracket of any shape and size complete all as specified and directed.
M&L for preparing surfaces of electric poles of any type of following sizes including MS cross arms, MS clamps, street light brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of primer and two coat of aluminium paint completely, alternate layer of yellow and black paint of 150 mm strip at the bottom of pole 1.5 mtr above coping with synthetic enamel paint complete all as specified and directed. Height of HT rail/tubular poles exceeding 7.5 Mtrs upto 9.5 Mtrs above ground leval.
Height of steel tubular poles 7.5 Mtrs above ground level .
M&L for preparing surfaces of electric poles of RCC type of any sizes including MS cross arms, MS clamps, street light brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of primer and two coat of weather proof paint completely and alternate layer of yellow and black synthetic enamelled paint of 150 mm strips at the bottom of pole 1.5 mtr above coping complete all as specified and directed.
M&L for preparing surfaces of electric TWO pole Structures of any make and height of pole up to 10 Mtrs above ground level including MS cross arms, AB Switch pipe, DO Fuse assembly,MS clamps, brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of aluminium paint complete all as specified and directed.
M&L for preparing surfaces of electric Four pole Structures of any make and height of pole up to 10 Mtrs above ground level including MS cross arms, AB Switch pipe, DO Fuse assembly,MS clamps, brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of aluminium paint complete all as specified and directed.
M&L for writing pole No. with letters of size 25 mm height on pole/ plate with Black synthetic enamelled paint complete all as specified and directed.
Supply and fix Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 50mm outer diameter and 38 mm inner Diameter with IS 14930 (part 2):2001 laid in trenches,wall,floor,pole including bends, sockets and other connected accessories complete all as specified and directed. Make:- Dura. Line/Tijaria/REX.
Taking down the unserviceable LT cable of any size from tranches/ walls /floor etc complete all as specified and as directed. Note :- laying of cable route is same as old cable route .
Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened,PVC bedded, galvanised steel strip, electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sq mm, 4 core including testing after laid and jointed all as specified and as directed Make :- Gloster/ Polycab/Havells Note:- Excavation and earth work sand cushioning pipe/ cable protection shall be measured and paid separetely.
M&L stainless steel fabrication works such as angle / FI clamp, SS pipe nuts, bolts, washers welding, bending cold or hot drilling holes for bolts in any shape and size etc including two coats of synthetic enamel paint cover a coat of red oxide primer complete all as specified and directed.
S&F of 25 W LED post top luminaire has a single piece construction. Comprises of die cast housing and PC diffuser & spun aluminium reflector having system lumens > 4000. The operating voltage 120-277Vac with PF > 0.9. The LED is SMD type only with CCT 5700K CRI >75. The luminaire is IP 65, IK 10 and Electrical protection Class I. Driver should have 4KV Internal & 5KV External surge protection , The life of LEDs > 50000 hours at L70. ( Dimension : top : 410mm dia , 395mm height , OD Size : 62 mm ) complete all as specified and directed. (Bajaj Cat No BLPTSP 25W LED WW ,Philips,Crompton
M&L for GI Tubes, 'light grade', galvanised 40 mm with all fitting like reducers,threading , making hole for for running electrical coneections for gaden lights post including taking out old unservicable Tubes complete all as specified and directed.
M&L PCC (1:2:4) witjh 20 mm aggregate in lintels upto 1.5m clear span, cills, steps; seismicand other similar bands,plinth courses, string courses,lacing courses, parapets andrailings upto 60 cm in height,copings, complete all as specified and directed.
M&L PCC (1:2:4) witjh 20 mm aggregate in lintels upto 1.5m clear span, cills, steps; seismicand other similar bands,plinth courses, string courses,lacing courses, parapets andrailings upto 60 cm in height,copings, complete all as specified and directed.
M&L Rendering 15 mm thick plaster on fair faces of brickwork or concrete sur faces in CM (1:6) all as finishing the surface complete all as specified and directed.
M&L for painting on steel surface with two coat of synthetic enamell paint including necessary preparation complete all as specified and directed.
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs. 62,708.00]
Paragon Electrotechnics
Bidder Name
Paragon Electrotechnics
Chinmaya Enteprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .