Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance NO 15A NETHAJI NAGAR 8TH STREET ENNORE HIGH ROAD CHENNAI 600057 | CHENNAI | CHENNAI | TAMIL NADU | 600057 | Admitted-Finance |
| 2 | Admitted-Finance NO 172 VAZHAPANTAL ROAD STREET MAMBAKKAM ARCOT TALUK VELLORE DIST 632 318 | MAMBAKKAM | ARCOT TALUK | TAMIL NADU | 632318 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹62,600
Closing Date
4 Dec 2023, 2:00 pmClosed
CE/TP I
A10 Thiru vi ka Indl Estate Guindy Chennai 32
Supply of Iron and steel, fabrication and erection of structures, Equipments erection, etc., dismantling of existing 33kV and 11kV structures, equipments for Upgradation of the existing ICF 33kV Outdoor SS into 110kV AIS SS
2023_EB_390592_1
TP1-70/2023-24
Open Tender
Electrical Works
Works
180 days
Guindy
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹62,600
Yes
6 Feb 2024
20 Nov 2023
5 Dec 2023
20 Nov 2023
4 Dec 2023
20 Nov 2023
Amount
Supply,fabrication,sand blasting & Zinc painting of RS Joist 200x100 mm, 250x125 mm & 12/16 mm base plate as per latest IS including the cost of all materials, transport, labour, lead, lift etc., complete as per IS Specification and as directed by the dept.engineer at site.
Supply, fabrication, sand blasting & Zinc painting of (125 x 65 /100x50) MS angle & MS Channels as per latest IS various size including the cost of all materials, transport, labour, lead, lift etc., complete as per IS Specification and as directed by the dept.engineer at site.
Labour for erection of structure including the cost of all labour, lead, lift etc., complete as directed by the dept.engineer at site. Heavy section structure. (Sectional weight 14kg/m and above)
Labour for erection of structure including the cost of all labour, lead, lift etc., complete as directed by the dept.engineer at site. Light section structure. (Sectional weight 14kg/m and below)
Labour for dismantling of existing 33 kV and 11 kV structure including the cost of all labour, lead, lift etc., complete as directed by the dept.engineer at site.Heavy section structure.
Labour for dismantling of existing 33 kV and 11 kV structure including the cost of all labour, lead, lift etc., complete as directed by the dept.engineer at site. Light section structure.
Labour charges for erection with own crane arrangement and connecting link rod, SF6 gas filling and other consumables as directed by the dept.engineer at site. SF6 Circuit Breaker 110 KV
Labour charges for erection and alignment of AB Switches including cost of lubricant, consumable and wiring (if necessary), allignment, checking of operation by both manual and electrical (if necessary) labour,lead,lift etc.,complete as per IS specification and as directed by the field Engineer at site. 110 KV with earth hand operated.
Labour charges for erection and alignment of AB Switches including cost of lubricant, consumable and wiring (if necessary), allignment, checking of operation by both manual and electrical (if necessary) labour,lead,lift etc.,complete as per IS specification and as directed by the field Engineer at site. 110 KV without earth hand operated.
Labour charges for erection of auxilaries equipment or using own crane arrangement, including providing holes wherever required, fixing junction box and other consumable as directed by the dept.engineer at site. 110 KV CT & PT.
Labour charges for erection of LAS including fabircation of base if required and all labour, lead, lift etc., complete as directed by the dept.engineer at site. 110 KV Station type.
Dismantling of existing 11 kV breaker - 08 Nos. and 33 kV Feeder breaker - 03 Nos.
Dismantling 16 Nos. 11 kV Centre roatating AB switch and 06 Nos. 33 kV Feeder Centre roatating AB switch
Labour charges for erection of 11 KV/433 V, 1000KVA distribution transformer with own crane arrangement including Labour, transport,lead,lift etc., complete as per standard specification and as directed by the dept.engineer at site.
Labour for stringing of strung bus including hoisting of insulators including the cost of all labour, lead,lift etc., complete as directed by the dept. engineer at site. 110 KV zebra conductor (1 span 6 runs).
Labour for erection of single pole stack upright under hang or suspension including the cost of labour, transport, lead, lift etc., complete as per standard specification and as directed by the dept.engineer at site. 110 KV
Fabrication and fixing of bell mouth providing jumber connection in the solid core/PT insulators including the cost of GI pipe 50 mm dia one meter & other consumables and as directed by the field engineer.
Dismantling of existing 11 kV strung bus (1 Span of 3 Runs)
Supply and erection of 'B' class GI Pipe for extension of tandum / down pipe for AB switches and for any other works as required including cost of GI pipe and as directed by the dept.engineer at site. 32mm dia
Labour for erection of bus bar including fabrication and any modification of end clamp wherever necessary and the cost of all labour,lead,lift etc., complete as directed by the dept. engineer at site. Using 75mm IPS AL tube with making bends
Labour for erection of bus bar including fabrication and any modification of end clamp wherever necessary and the cost of all labour,lead,lift etc., complete as directed by the dept. engineer at site. Using 75mm IPS AL tube without making bends
Labour for providing jumpers and droppers including the cost of all labour,lead,lift etc., complete as per IS Standard and as directed by the dept. engineer at site.
Supply, transport, loading & unloading of MS plate (65x10mm) for earth mat and MS Flat 50x8 mm thick for earth raiser to site including the cost of all materials, transport, labour, lead, lift etc., complete as per IS Specification and as directed by the dept.engineer at site.
Supply and fabrication of earth electrode 6.00mtr length with 40mm MS Round Rod (10m/6m length) including transport and other charges and erection of earth spikes, including cost of MS Rod 40mm, transport,labour,lead, lift etc., complete as per IS Specification and as directed by the dept.engineer at site.
Labour for excavation and refilling of trench of average width of 0.3m and average depth of 0.8M for earth mat and 0.4m for laying of cable below fixed yard level and of any size as required by field engineer.
Labour,machineries, consumables for erection of earthmat and earth raiser. including the cost of all labour,lead,lift etc., complete as directed by the dept. engineer at site.
Providing 140/150mm dia bore including labour, lead,lift etc., including mobilization in all type of soil and erection of earth electrode, supply and providing of A Grade bentonite powder with 5% common salt mixed with available site clay soil 5kg per metre depth in earth hole as direcetd by the field engineer.
Labour, machineris, consumables for fabrication of earth electrode 10 mtr/6mtr length or as required length including the cost of all labour,lead, lift etc., complete as directed by the dept.engineer at site.
Labour,machineries, consumables for erection of earth spikes including the cost of all labour,lead,lift etc., complete as directed by the dept. engineer at site.
Supply and providing of 600 mm mean dia,300mm height, 36mm thick cement collar for identification of earth electrode location including 1 primer and 2 coat of colour wash as directed by field engineer.
Labour for erection of panel/battery charger simplex indoor/outdoor including the cost of all labour,lead,lift etc., complete and as directed by the dept. engineer at site.
Labour for erection of battery including assembling of wooden stand, painting of acid proof paint (if necessary) ,cost of all labour, lead, lift, etc., complete as directed by the department engineeer at site. 110 V, 300 AH
Labour tools for charging of battery including the cost of all labour, lead, lift, etc., complete as per standard specification and as directed by the department engineeer at site.110 V, 300 AH
Supply and fixing of ISI mark porcelain rewirable fuse unit of reputed make in panels/boxes for AC circuits wherever required as directed by the field engineer. 100 Amps
Laying of 120 sq.mm LT AC Armoured power cables cables from station Transformer to AC change Over switch, AC panel, InterPanels, AC Didtribution Boxes in Control room and Switchyard etc, making terminations, including suitable size lugscable clamping and supporting ar per site requirement.
Fabrication, Suply and fixing of AC Disctribtion box of size 750Wx250Dx750H mm out of 14SWG (12mm) MS Sheet wherever necessary as directed by field engineer. The box shall be vermin proof shall have sturdy hinges, provision for mounting MCB and MCCB detachable gland plate and locking arrangements incl. cost of all materials
Supply & fixing of ISI mark HRC Fuse without holder of reputed make in panels /boxes for AC/DC/PT Circuits -2/5/10Amps
Labour charges for laying control cables in trench/pits upto 8 cores
Labour charges for laying control cables in trench/pits above 8 cores
Supply and glanding of ISI mark cable glands of suitable size of reputed make including removing insulation of cable and providing suitable holes as directed by the field engineer. 19 MM
Supply and glanding of ISI mark cable glands of suitable size of reputed make including removing insulation of cable and providing suitable holes as directed by the field engineer. 25 MM
Supply and glanding of ISI mark cable glands of suitable size of reputed make including removing insulation of cable and providing suitable holes as directed by the field engineer. 28 MM
Supply and glanding of ISI mark cable glands of suitable size of reputed make including removing insulation of cable and providing suitable holes as directed by the field engineer. 32 MM
Supply and glanding of ISI mark cable glands of suitable size of reputed make including removing insulation of cable and providing suitable holes as directed by the field engineer. 35 MM
Supply and termination of cable core end including cost of cable socket (Lugs), ferrules straps etc as per cable schedule and as directed by the field engineer.
Supply and erection of GL ladder type cable tray including jointing of pad and bolt & nut GL ladder type cable tray (2.4 m L x 0.45 m W)
Supply and erection of GL ladder type cable tray including jointing of pad and bolt & nut GL ladder type cable tray (2.4 m L x 0.3 m W)
Supply and erection of GL ladder type cable tray including jointing of pad and bolt & nut GL ladder type cable tray (2.4 m L x 0.15 m W)
Supply and fixing of mounting channels/rails, suitable for CBTM5 terminal block in panel/box and as required and directed by field engineer.
Supply and fixing of nut type CBTM5 terminal block in panel box as required and as directed by the field engineer.
Supply and fixing of disconnecting type terminal block for CT/PT circuits in panel box as required and as directed by the field engineer.
Labour for Loading, transporting from stores or other places ,Unloading, and Laying of one run of 33 kV, 630 sq.mm XLPE Aluminum UG cables between one number 50 MVA, 110/33 kV Power transformer and respective HV & LV Breaker.
Supply and erection charges for making of 33kV and 11 kV, 630 sq.mm HS type terminations of cables at both ends (Outdoor), Connecting to the Breakers/transformers and earthing at One end as per site requirement.
Supply and erection charges for making of 33kV and 11kV, 630 sq.mm HS type terminations of cables at both ends (Indoor), Connecting to the Breakers/transformers and earthing at One end as per site requirement.
Supply and fixing of cable support clamps at both end suitable for 33 kV, 630 Sq.mm Aluminum Power cables.
Supply and provision of varios size of M.S Cadmium and GI -Screws, Washers and foundation bolts for erection of cable structures and cable Lugs fixing as required at site.
Supply and Erection of 6 m long stepped tubular Yard Light Pole with base plate including laying of cable, earthing of poles using 12SWG GI wire as per specifications/drawing.
Supply and Erection of 72 Watts LED lamp with fitting and fuse box including wiring and testing for glowing condition including the cost of 15 Amps. 2 Way strip connector and other consumables.
Manufacturing and supply of yard light box of size 200W X 200H X 150D mm out of out of 18 SWG (1.2MM) MS Sheet with cable entry holes, fixing arrangement for fuse units and mounting clamp including the cost of all materials transport, labour,lead,lift etc., complete as directed by the dept. engineer at site.
Labour charges for writing details in finished surface boards including cost of enamel paint (dulex, asian berger preferred) and other consumables as directed by the field engineer.
Manufacturing and supply & Fixing of LC / Key board out of 75x25mm Alu. frame embedded with 12 mm prelaminated wood particle board using screw on rear two nos of plain glass of 5 mm thick fixed with metal roller moving on aluminum channel should be provided on front with locking arrangements. LG glass pieces should be fastened on the glass shutters for opening and closing wall clamp made out of 6 mm plate should be provided on top as per drawing and as directed by the field engineer including cost of all materials.
Labour charges for drawing layout and writing details in LC/Keyboard including cost of enamel paint (Dulex, asian, berger preferred) and other consumables as directed by the field engineer.
Fabrication, supply and fixing of main equipment board of various size 750x450mm out of 14SWG (2MM ) and fire stand and etc., as per drawing and as directed by the field engineer including the cost of all materials.(Main Board-1, Fire Strand-2)
Labour charges for removing rust primer coat first and second coat painting both sides and MS boards RS joist & yard light pole etc., including cost of enamel paint (dulex, Asian Berger preferred) and other consumables as directed by the field Engineer.
Manufacturing, supply and fxing of Earthing layout board (Wooden/Plastic/ Aluminium) having the size of 1200x600 mm and board covered with 3mm thick achorlictransparant sheet as directed by the field Engineer.
Supply and fixing of plastic name board (Feeder name, under LC in service) as directed by the field Engineer.
Supply of fire extingusher including the cost of labour, transfort, lead, lift etc., complete as per standard specification and as directed by the dept.engineer at site.DCP type portable 10 KG Capacity .
Supply of fire extingusher including the cost of labour, transfort, lead, lift etc., complete as per standard specification and as directed by the dept.engineer at site.DCP type trolly mounted 25 Liter .
Supply of fire extingusher including the cost of labour, transfort, lead, lift etc., complete as per standard specification and as directed by the dept.engineer at site.DCP type portable 6 KG Capacity .
Manufacturing and supply of fire bucket of 10 lit. Capacity made out of 26SWG (0.46MM) M.S.Sheet painted with white and red enamel paint in side and out side respectively bottom of bucket shall be 'U' Shapped out side of the bucket shall be written as FIRE in English/Tamil in white enamel paint including the cost of materials and as directed by the field engineer at site.
Manufacturing and Supply of sand drum of size 580 mm dia and 420 mm height with conical cover, made out of thin sheet provided with Handle, incl. Cost of barrial, Sand and consumable as directed by the field engineer.
Supply of 2 M X 1 M X 10 mm thick Rubber Mat
Supply and fixing of First Aid Box as directed by the field Engineer.
Supply and fixing of (Godrej 6 lever Navotal lock with triplicate keys for AB Switches and for any other purpose including the cost of ring and key token as directed by the field engineer.
Manufacturing and supply of Bolt of required lengtrh of 18-20 mm GI rod including the cost ofg GI rod and 2 Nos. GI nuts and washers
Supply and provision of M8,M9, M10,M12,& M 16 full thread GI bolt, nuts & GI washer of various size for erection of insulator or any other purpose wherever required and as directed by the field Engineer.
Hire charges for Provision of Crane for any additional works like Dismantling, Re erection, Loading /Unloading or shifting of equipments. etc as required at site.
Labour for loading or unloading or shifting of materials etc., including the cost of all labour, lead, lift etc., complete as directed by the dept. engineer at site. Non - fragile
Labour for loading or unloading or shifting of materials etc., including the cost of all labour, lead, lift etc., complete as directed by the dept. engineer at site. Fragile
Supply and Fixing of Tension Fitting Clamp for Zebra 6 Bolts confirm to latest IS
Supply and Fixing of Free end clamp for 75 mm Al. Bus confirm to latest IS.
Supply and Fixing of T Clamp for 75 mm Al. bus to Zebra confirm to latest IS.
Supply and Fixing of T Clamp for 75 mm Al. bus to Double Zebra confirm to latest IS.
Supply and Fixing of T Clamp for Zebra to Zebra confirm to latest IS.
Supply and Fixing of T Clamp for Double Zebra to Double Zebra confirm to latest IS.
Supply and Fixing of Switch End Clamp for Zebra confirm to latest IS.
Supply and Fixing of Switch End Clamp for 3" Busbar confirm to latest IS.
Supply and Fixing of PG Clamp for Zebra confirm to latest IS.
Supply and Fixing of Seating Block for 3" Bus confirm to latest IS.
Supply and Fixing of Reducer clamp for 75mm bus bar to zebra confirm to latest IS.
Supply and Fixing of Corona Ball for 3" Bus confirm to latest IS.
GST for bidders within TamilNadu
GST for bidders outside TamilNadu (IGST)
JD ENTERPRISES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .