Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹74.9 LAccepted-AOC 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | 1 | Accepted-AOC Acceptance Of Tender | |
| 2 | 2₹85.3 L+₹6.9 L (8.84%)Rejected-Finance E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹91.3 L+₹13.0 L (16.5%)Rejected-Finance M 78 GARU HARKISHAN NAGAR PASCHIM VIHAR NEW DELHI 110087 | NEW DELHI | WEST DELHI | DELHI | 110087 | 3 | Rejected-Finance Not L1 |
| Sl No | Description | Qty | Unit | SALUJA CONSTRUCTION CO L3 | GIAN ENGINEERS L2 | M/S S.B. Singh and Sons L1 |
|---|---|---|---|---|---|---|
| 1.00 | S&F in renewal sluice valve flanged ends,150 mm, class PN 1.6, ISI marked including jointing material complete. | 288 | Each | 13,620 ₹39,22,560 | 14,125.5 ₹40,68,144 | 10,470 ₹30,15,360 Lowest |
| 2.00 | S&F in renewal CI reflux valve (Non Return Valve) both end flanged of size 150 mm ISI marked without by pass arrangement including jointing material complete. | 35 | Each | 12,920 ₹4,52,200 | 13,573.5 ₹4,75,072.5 | 10,270 ₹3,59,450 Lowest |
| 3.00 | Demolition and re-construction of brick masonry valve pit chamber of size 900 mm x 900 mm x 900 mm depth (internal size) with 3 mm thick MS sheet cover and 40 x 40 x 5 mm angle iron frame embedded in PCC coping 1:3:6 type C-1 using 20 mm graded stone aggregates with locking arrangements and painting with two coats of black japanee paint over a red oxide primer after preparation of steel surface, brick work in cement mortar 1:6 using sub class ‘B’ (old size) bricks, internal walls plastered with 15 mm thick cement mortar 1:6 with WPC and finishing the surface even and smooth without using extra cement, outer walls plastered with 15 mm thick cement mortar 1:4, PCC 1:2:4 type B-1 using 20 mm graded stone aggregate 40 mm thick in coping, PCC 1:4:8 type D-2 using 40 mm graded stone aggregates in foundation 75 mm thick with and including necessary excavation & earth work in soft / loose soil complete. | 33 | Each Job | 8,060 ₹2,65,980 Lowest | 11,500 ₹3,79,500 | 9,800 ₹3,23,400 |
| 4.00 | Demolition and re-construction of brick masonry valve pit chamber of size 1200 mm x 1200 mm x 1200 mm depth (internal size) with 3 mm thick MS sheet cover and 40 x 40 x 5 mm angle iron frame embedded in PCC coping 1:3:6 type C-1 using 20 mm graded stone aggregates with locking arrangements and painting with two coats of black japanee paint over a red oxide primer after preparation of steel surface, brick work in cement mortar 1:6 using sub class ‘B’ (old size) bricks, internal walls plastered with 15 mm thick cement mortar 1:6 with WPC and finishing the surface even and smooth without using extra cement, outer walls plastered with 15 mm thick cement mortar 1:4, PCC 1:2:4 type B-1 using 20 mm graded stone aggregate 40 mm thick in coping, PCC 1:4:8 type D-2 using 40 mm graded stone aggregates in foundation 75 mm thick with and including necessary excavation & earth work in soft / loose soil complete. | 10 | Each Job | 9,160 ₹91,600 Lowest | 13,500 ₹1,35,000 | 13,000 ₹1,30,000 |
| 5.00 | S&F in renewal LED security light fixture 35 watt powder coated pressure die cast aluminum body with driver Input voltage: 140-270 Volt AC, 50 Hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC as per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the requirement, life of LED & electrical circuitry minimum 50000 burning hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect including connections with suitable size FRLS, PVC insulated copper conductor cable and earthing et. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. | 155 | Each | 2,156 ₹3,34,180 | 2,000 ₹3,10,000 | 1,380 ₹2,13,900 Lowest |
| 6.00 | S&F in renewal LED surface mounted Batten 20 watt, powder coated die cast / extruded aluminium Body (Thickness ≥ 1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50 Hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5%), life expectency (LED & electrical circuitary) of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends, CCT 5700°K/ 6000°K/ 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect including connections with suitable size FRLS, PVC insulated copper conductor cable and earthing etc as required with Minimum 5 year OEM warranty. System lumen efficacy 120 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as BIS shall be submitted. | 50 | Each | 600 ₹30,000 | 550 ₹27,500 | 422 ₹21,100 Lowest |
| 7.00 | M&L for earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth strip 32 x 6 mm by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I 2009 connected to earthing point and testing on completion with and including PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 6 mm dia M.S bars 3 Nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work complete. (Note - GI strip size 32x6 upto 7.5 m is included in the item). | 30 | Each | 5,460 ₹1,63,800 | 5,000 ₹1,50,000 | 3,800 ₹1,14,000 Lowest |
| 8.00 | Taking down carefully surface aluminium or copper point wiring with PVC casing-caping or conduit (light, fan, socket, or power) including fixture and fittings such as switches, ceiling roses, regulators, sockets etc and making good disturbed surfaces even and smooth using CM 1:3 including white/colour wash to match the existing surface complete. | 200 | Point | 5 ₹1,000 Lowest | 40 ₹8,000 | 20 ₹4,000 |
| 9.00M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm and earth continuity conductor 1.5 sqmm using colour coding drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 25 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken modular GI metal boxes not less than 1.0 mm thick and white modular mounting cover plates with frame for mounting modular switches, sockets, fan regulators etc as required for the following:- | ||||||
| 9.01 | (a) One light/ fan (CF & EF) point controlled by one switch. | 130 | Point | 442 ₹57,460 | 650 ₹84,500 | 375 ₹48,750 Lowest |
Tender Value
₹1.0 Cr
EMD Value
₹2.0 L
Closing Date
1 Nov 2025, 6:00 pmClosed
CWE Lucknow
HQ CWE Lucknow, 229 MG Road, Lucknow Cantt, Lucknow-226002
SPL REPAIR TO VALVE PITS LT PANEL INTERNAL ELECTRIC AND OTHER CONNECTED WKS IN PUMP HOUSE OF AGE EXTERNAL WATER SUPPLY UNDER GE E/M LUCKNOW
2025_MES_733731_1
CWE/LKO/EM/T-95 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Lucknow
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE EM Lukcnow
₹2.0 L
Yes
27 Nov 2025
4 Oct 2025
8 Nov 2025
4 Oct 2025
1 Nov 2025
25 Oct 2025
4 Oct 2025 - 25 Oct 2025
Amount
S&F in renewal sluice valve flanged ends,150 mm, class PN 1.6, ISI marked including jointing material complete.
S&F in renewal CI reflux valve (Non Return Valve) both end flanged of size 150 mm ISI marked without by pass arrangement including jointing material complete.
Demolition and re-construction of brick masonry valve pit chamber of size 900 mm x 900 mm x 900 mm depth (internal size) with 3 mm thick MS sheet cover and 40 x 40 x 5 mm angle iron frame embedded in PCC coping 1:3:6 type C-1 using 20 mm graded stone aggregates with locking arrangements and painting with two coats of black japanee paint over a red oxide primer after preparation of steel surface, brick work in cement mortar 1:6 using sub class ‘B’ (old size) bricks, internal walls plastered with 15 mm thick cement mortar 1:6 with WPC and finishing the surface even and smooth without using extra cement, outer walls plastered with 15 mm thick cement mortar 1:4, PCC 1:2:4 type B-1 using 20 mm graded stone aggregate 40 mm thick in coping, PCC 1:4:8 type D-2 using 40 mm graded stone aggregates in foundation 75 mm thick with and including necessary excavation & earth work in soft / loose soil complete.
Demolition and re-construction of brick masonry valve pit chamber of size 1200 mm x 1200 mm x 1200 mm depth (internal size) with 3 mm thick MS sheet cover and 40 x 40 x 5 mm angle iron frame embedded in PCC coping 1:3:6 type C-1 using 20 mm graded stone aggregates with locking arrangements and painting with two coats of black japanee paint over a red oxide primer after preparation of steel surface, brick work in cement mortar 1:6 using sub class ‘B’ (old size) bricks, internal walls plastered with 15 mm thick cement mortar 1:6 with WPC and finishing the surface even and smooth without using extra cement, outer walls plastered with 15 mm thick cement mortar 1:4, PCC 1:2:4 type B-1 using 20 mm graded stone aggregate 40 mm thick in coping, PCC 1:4:8 type D-2 using 40 mm graded stone aggregates in foundation 75 mm thick with and including necessary excavation & earth work in soft / loose soil complete.
S&F in renewal LED security light fixture 35 watt powder coated pressure die cast aluminum body with driver Input voltage: 140-270 Volt AC, 50 Hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC as per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the requirement, life of LED & electrical circuitry minimum 50000 burning hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect including connections with suitable size FRLS, PVC insulated copper conductor cable and earthing et. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted.
S&F in renewal LED surface mounted Batten 20 watt, powder coated die cast / extruded aluminium Body (Thickness ≥ 1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50 Hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5%), life expectency (LED & electrical circuitary) of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends, CCT 5700°K/ 6000°K/ 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect including connections with suitable size FRLS, PVC insulated copper conductor cable and earthing etc as required with Minimum 5 year OEM warranty. System lumen efficacy 120 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as BIS shall be submitted.
M&L for earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth strip 32 x 6 mm by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I 2009 connected to earthing point and testing on completion with and including PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 6 mm dia M.S bars 3 Nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work complete. (Note - GI strip size 32x6 upto 7.5 m is included in the item).
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping or conduit (light, fan, socket, or power) including fixture and fittings such as switches, ceiling roses, regulators, sockets etc and making good disturbed surfaces even and smooth using CM 1:3 including white/colour wash to match the existing surface complete.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm and earth continuity conductor 1.5 sqmm using colour coding drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 25 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken modular GI metal boxes not less than 1.0 mm thick and white modular mounting cover plates with frame for mounting modular switches, sockets, fan regulators etc as required for the following:-
(a) One light/ fan (CF & EF) point controlled by one switch.
(b) One 5 pin socket outlet 6 Amps on same board controlled by one switch with other switches.
(c) One 5 pin socket outlet 6 Amps on independent board controlled by one switch.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 sqmm and earth continuity conductor 2.5 sqmm using colour coding drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 25 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken modular GI metal boxes not less than 1.0 mm thick and white modular mounting plates with frame for mounting modular switches, sockets as required for 3 pin 16 amps socket outlet point controlled by one switch.
S&F modular switch, one way 6 Amp, 1 module
S&F modular switch, one way 16 Amp, 1 module
S&F modular socket 6 Amp, 2 / 3 pin, 1 module
S&F modular socket 6/16 Amps, 2/ 3 pin 2 module
S&F modular fan regulator 2 module.
S&F ceiling rose 3 plates polycarbonate body complete.
S&F modular angle holder of polycarbonate body with frame complete.
S&F in renewal MCB distribution board SPN, 240 volts, 8 ways, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
S&F in renewal MCB single pole 6 to 32 amp 'C' Curve having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs as required.
S&F in renewal MCBs SPN 32 amp 'C' Curve having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs as required.
S&F in renewal security light bracket made of GI pipe light grade 32 mm dia 1.2 mtr long bend to shape and clamped with two numbers flat iron clamps of size 25x5 mm, nuts, bolts washes & painted with 2 coats of aluminium paint over a red oxide primer on clamps complete.
S&F in renewal outdoor type wall mounted water level indicator panel having environmental protection IP-67.and consisting of 05 numbers water levels for direct contact type point level sensors along with alarm annunciation for complete empty or complete full of OHT or UG sump including SMPS, Power ON (Green) LED lamp, MCB with proper ferruling, wiring etc as required.
S&F in renewal non-rusting type teflon coated magnetic float point level sensor having wire length 5 meter minimum complete.
S&F in renewal 5 pair x 0.5 sqmm armoured copper cable on wall or in the trench along with necessary clamping with saddles or cable ties from OHT or UG Sump to WLC Panel as required.
GIAN ENGINEERS (BID ID -3464297)
SALUJA CONSTRUCTION CO (BID ID -3468622)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
TenderT95.pdf
Tender Documents • 0.61 MB
BOQ_821544.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .