| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-Finance 6 STATION ROAD BERHAMPORE MURSHIDABAD WEST BENGAL 742101 | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742101 | L1 | Accepted-Finance 1st lowest | |
| 2 | L2₹32.1 L+₹67,743 (2.16%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹32.8 L+₹1.3 L (4.25%)Rejected-Finance MAIRAKATA P O GARBETA DIST PASCHIM MEDINIPUR 721127 | GARBETA | PASCHIM MEDINIPUR | WEST BENGAL | 721127 | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹62,689
Closing Date
25 Sept 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, PWDte
Bankura
SITC of Air Condition machine at various rooms of on-duty doctors for the Dept. of Paediatric, Anesthesiology and Gynecology at BSMC and H, Bankura.
2024_WBPWD_752569_1
WBPWDTE/EE/BED/NIQ_112/Q of 2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Wise
30 days
Anesthesiology and Gynecology at BSMC and H
Please refer Tender documents.
3 documents required · 3 mandatory
₹62,689
27 Sept 2024
18 Sept 2024
27 Sept 2024
18 Sept 2024
25 Sept 2024
18 Sept 2024
Amount
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. ( on MS angleiron frame on wall ) 200A ( L& T make)
Supply Delivery of 1.1kv 4 core95 sqmm Al/Armoured cable ( Gloster/ Polycab/KEI )
Laying of one nocable above 35 sqmm & upto 185 sqmm in underground trench 460 mm wide x 760 mm averagedepth with brick protection on the top of the cable with 8 ( eight )no bricks permtr.incl. filling thespace between the brick &cable also thetrench with shifted soil , leveling up &restoresurface duly rammed.
Supply & fixing medium gauge GI pipe ( ISI- Medium) protection with necessary fittings & jointing materials asrequired. 50 mm dia
Supply & fixing compression type gland complete with brass gland, brass ring & rubber ring fordust & moisture proof entry of XLPE/PVC armoured cable. 4 core 95 sqmm
Finishing of the XLPE/ PVC insulated armoured cable ends bycrimping methode incl supply & fixing solderless socket ( Dowels make ) , tapes, anticorrosive paste & jointing material. 4 core 95 sqmm
Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex / Havells/ KEI / Gloster /approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2 x 4 sqmm + 1 x 2.5sqmm (for AC Machine )
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 2.5 sq mm
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as per G.S.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
S & F 240V 21A OLP - 30 Electrronic motor starter in 175mm X 100mm X 65 mm depth 16 SWG MS Box coneled in wall with bakelite top cover incl. Necy. Conncetion as per direction of EIC for AC Machines.(Make: Electron)
Supply and Delivery of Timer DB 1) 230V, Upto 16 A capacity 24 Hrs Analog Electromechanical Time Switch(Make-(L&T-(L&T-AUTS03ANA00/Legrand/ABB) 2) 2 Pole Power Contrcator (L&T-MNX 22-2P Cat No-CS90238/Legrand/ABB)----- 01 Nos 3) 16A SP MCB.---- 01 Nos (Legrand/ABB/Siemens) 4) 32A DP Isolator ---- 01 Nos (Legrand/ABB/Siemens) 5) Toggle Switch.(Reputed Make) 5) (2+12 Way) SPNDB--- 01 nos (Legrand/ABB/Siemens) Suitable Size Copper Stranded Wire. 6) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar etc with this box for termination of power. 7) The complete arrangement must be wiring by 2.5 Sq mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (Make - Legrand /L & T / ABB )
Supply and Delivery of Timer DB 1) 230V, Upto 16 A capacity 24 Hrs Analog Electromechanical Time Switch(Make-(L&T-(L&T-AUTS03ANA00/Legrand/ABB) 2) 2 Pole Power Contrcator (L&T-MNX 22-2P Cat No-CS90238/Legrand/ABB),- 02 nos 3) 16A SP MCB.----02 nos (Legrand/ABB/Siemens) 4) 32A DP Isolator. ----- 01 nos (Legrand/ABB/Siemens) 5) Toggle Switch. 5) (2+12 Way) SPNDB (Legrand/ABB/Siemens) Suitable Size Copper Stranded Wire. 6) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar etc with this box for termination of power. 7) The complete arrangement must be wiring by 2.5 Sq mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (Make - Legrand /L & T / ABB )
Supply and delivery of Non-inverter wall mounted SPLIT room air conditioner having the following major specification:- (a) Minimum Cooling capacity required : 24000 BTU / Hr. or Higher (b) Minimum Star rating-2 Star or higher (c) Rated voltage—230v +/-5%, Frequency-50Hz. (d) Compressor type-Rotary. (e) Mini. Room Discharge air flow rate- 650 CFM or higher f) Condenser tube -Copper condenser coil g) Minimum Tonnage required: 2 TR or higher h) Refrigarent- R32/R410A i) Cordless Remote arrangement with all modernized provision of temperature settings, Fan speed option(low/medium/high), Auto swing, Air direction setting, Timer facility, Turbo operation setting, Air ventilation arrangement, and others.Incl. delivery charges. ( Make:- Mitsubishi Electric Model- MS/MU- GK24VA /O-General Model - ASGA24BMWA-B / Mitshubhisi Heavy Industries)
Supply and delivery of Non inverter wall mounted SPLIT room air conditioner having the following major specification:- (a) Minimum Cooling capacity required : 18000 BTU / Hr. or Higher (b) Minimum Star rating- 2 Star or higher (c) Rated voltage—230V +/-5%, Frequency-50Hz. (d) Compressor type- Rotary. (e) Mini. Room Discharge air flow rate - 620 CFM or higher f) Condencer tupe -Copper condencer coil g) Minimum Tonnage required : 1.5T or higher h) Refrigarent- R32/R410A i) Cordless Remote arrangement with all modernize provision of temperature setting, Fan speed option(low/medium/high), Auto swing, Air direction setting, Timer facility, Turbo operation setting, Air ventilation arrangement and others.Incl. delivery charges. ( Make:- Mitshubishi Electric Model- MS/MU- GK18VA /O-General Model - ASGA18BMWA-B / Mitshubhisi Heavy Industries)
Installation, Testing & commissioning of 1.5/2.0 Tr. Split type AC both indoor/ outdoor unit incl. S& F of 40 X 40 X 5 mm MS angle iron frame for installation of ODU and sealing of the holes in wall created during the copper pipe connection between IDU & ODU by proper sand-- cement plastering and painting (both inside and outside) to match up with the original finish mending good the damages to complete the instn as per direction of EIC
Supply, Installation & commissioning of (i) gauge copper pipe 5/8" 0.7 mm thick for suction (ii) copper pipe 1/4" 0.6 mm thick for discharge (Make-Ryoku/Rajco/Nippon) with 9 mm nitrile rubber tube Insulation on the following sizes of the suction line & Liquid Line copper pipe with proper insulation tape (Make-Accoflex/ Armacell/K-Flex) with max saddling with max 1-meter distance both for suction & discharge pipe complete with fittings, elbows, bends, and supporting arrangements on walls.
S& Laying 3 core 4.0 sqmm PVC insulated & unarmoured copper cable (make-- Finolex/Havells/KEI) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.) with max saddling with max 1 mtr distance as per direction of EIC.
S & F of flexible PVC high quality water carrying pipe of proper size for draining water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high quality sealing gum etc. as reqd. All these arrangement for fixing must be arranged by the agency itself as per direction of EIC.
Supplying, fabrication & fixing of MS 8 mm road & 25 mm MS flat with necy. welding, screws and lugs with each other 25 x 25 x 5 mm MS angle support with necy. making of frame structure with necy. Two nos hinged arrangement with hatch bolt arrangement with shutter lock (3 key) 2 nos at least for each installation with necy. grouting arrangement on wall by anchoring by 25 x 25 x 5 mm MS angle at least 5" on wall with necy. painting two coat of synthetic enamel paint over one coat of RO primer with necy. direction of EIC For Outdoor units of split AC Machines (for protection) and For Horizontal run along the pipe line
SKY DECORATIONS PRIVATE LIMITED (BID ID -5601344)
R.K.ENTERPRISE (BID ID -5600610)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .