GE (West) Lucknow
GE (West) Lucknow PIN 226002
SPL REPAIR OF AREA DRAINAGE AT OFFRS MD ACCN ATAL ROAD AND OTHER MINOR WORKS IN AREA OF AGE BR-II UNDER GE (WEST) LUCKNOW
2026_MES_789181_2
GE/W/LKO/T-81 OF 2026-27
Open Tender
Civil Works
Item Rate
180 days
GE (West) Lucknow
As per NIT and Tender documents
8 documents required · 8 mandatory
₹500
GE (West) Lucknow
₹92,620
Yes
7 Nov 2026
7 Nov 2026
23 Nov 2026
7 Nov 2026
21 Nov 2026
14 Nov 2026
7 Nov 2026 - 11 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L Excavation in trenches in any type of soil not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation etc or for shafts, manholes, pier holes etc n.exc 10 sqm on plan and not exc 1.50m in depth and getting out in any type of soil, complete all as specified and directed . | 51.25 | Cum | - | - |
| 2 | M & L for cement concrete 1:4:8 type D2 using 40 mm graded aggregate in foundations / fillings and mass concrete including demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed . | 25.2 | Cum | - | - |
| 3 | Demolition of brick work or stone/ boulder masonry/PCC block masonary, built in cement mortar or cement lime mortar including all quoins, pillars etc complete all as specified and directed . | 104.4 | Cum | - | - |
| 4 | S & F of Precast U-shape drain(without lid cover) of size 450 mm(width) x 450 mm (depth) (from inner side of drain) x 2000 mm (length) and 610 mm(width) x 525 mm (depth) (from outer side of drain) made with Fe 500/550D grade TMT steel reinforcement bars in each unit which is made of High performance self compacting concrete (SCC) of M40 grade, cured under controlled factory conditions through steam curing,having loading capacity of 5 KN/Sqm with cover (light motor vehicle loading) .All manufacturing process must comply with Indian standards. The curing process must be maintained using RO water and chiller plants for quality assurance. The formwork used for casting should be made Automobile grade water tight steel enabling the production of highly accurate and consistent components. Concrete mix design of IS: 9103 with weight of each drain unit (without lid cover) atleast 560 kg (tolerance limit 3%).complete all as specified and directed .
note:- The work shall be carried through MOU of pre-cast factory.
Note:-
(i) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(ii) The contractor shall upload with the documents under Technical Bid (Cover-I) "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 270 | RM | - | - |
| 5 | S & F of Precast U-shape drain(without lid cover) of size 450 mm(width) x 600 mm (depth) (from inner side of drain) x 2000 mm (length) and 610 mm(width) x 680 mm (depth) (from outer side of drain) made with Fe- 500/550D Grade TMT steel reinforcement bars in each unit which is made of High performance self compacting concrete (SCC) of M40 grade, cured under controlled factory conditions through steam curing,having loading capacity of 5 KN/Sqm with cover (light motor vehicle loading) .All manufacturing process must comply with Indian standards. The curing process must be maintained using RO water and chiller plants for quality assurance. The formwork used for casting should be made Automobile grade water tight steel enabling the production of highly accurate and consistent components. Concrete mix design of IS: 9103 with weight of each drain unit (without lid cover) atleast 700 kg (tolerance limit 3%).complete all as specified and directed .
note:- The work shall be carried through MOU of pre-cast factory.
Note:-
(i) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(ii) The contractor shall upload with the documents under Technical Bid (Cover-I) "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 50 | RM | - | - |
| 6 | S & F of Precast U-shape drain Perforated Lid Cover for 450 mm drain of size 610 mm (width) x 500 mm (length)x70 mm (thickness ) made with Fe- 500/550D Grade TMT steel reinforcement bars in each unit which is made of High performance self compacting concrete (SCC) of M40 grade, cured under controlled factory conditions through steam curing,having loading capacity of 5 KN/Sqm with cover (light motor vehicle loading) .All manufacturing process must comply with Indian standards. The curing process must be maintained using RO water and chiller plants for quality assurance. The formwork used for casting should be made Automobile grade water tight steel enabling the production of highly accurate and consistent components. Concrete mix design of IS: 9103 with weight of each lid cover) atleast 50 kg (tolerance limit 3%).complete all as specified and directed .
note:- The work shall be carried through MOU of pre-cast factory.
Note:-
(i) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(ii) The contractor shall upload with the documents under Technical Bid (Cover-I) "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 320 | RM | - | - |
| 7 | M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed . | 18.15 | Cum | - | - |
| 8 | M&L for Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed . | 26.35 | Cum | - | - |
| 9 | Removal of excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. | 15.75 | Cum | - | - |
| 10 | M & L for 75mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base etc including demolition of Cement concrete (unreinforcde) in ground floor and paving n exc 15cm thickness and below or above ground level complete all as specified and directed | 60 | Sqm | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
TenderT-81.pdf
Tender Documents • 1.29 MB
BOQ_894950.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .