| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-Finance | L1 | Accepted-Finance Lowest Bidder | |
| 2 | L2₹29.4 L+₹1.9 L (6.74%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹30.6 L+₹3.0 L (10.9%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹31.3 L+₹3.8 L (13.6%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹32.5 L
EMD Value
₹65,000
Closing Date
8 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
OUTSOURCING OF SERVICES FOR VARIOUS ELECTRIC INSTALLATIONS UNDER AGE EM II IN GE C KIRKEE
2020_MES_360351_1
8377/E8 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹65,000
Yes
27 Aug 2020
11 Jul 2020
10 Aug 2020
11 Jul 2020
8 Aug 2020
27 Jul 2020
11 Jul 2020 - 25 Jul 2020
60 days
Amount
Outsoucing of services for operation and maintenance of HT Receiving station at "A" park CAFVD & Arsenal Depot including Sunday and holidays Consisting of two pole structure , transformer , LT panels APFC panel etc by providing suitably qualified and experienced one Electrician having knowlage HT 11/22 KV and LT 415 V supply system and Operation of DG sets with knowlage of preventive measures in case of electrical accident and fire fighting system.for two shifts and each shift of 8 hours from 0600 hrs to 2200 hrs all as specified and directed by Engr-in-Charge comprising the following works :- (a) Receiving and recording complaints in Complaint register and Maintaning complaint register as per norms. (MES norms as specified) (b) Attending major emergency complaint within short time. (c) Attending external breakdown complaint and disconnection/isolation of electric line of effected area immediately and restoration shall be done within short time or give information to JE / Engr-in-charge if the nature of repair is beyond their capacity/nature. (d) Cleaning of complaint cell building and machinaries installed in sub station. (e) Cheaking and maintaning of all incoming and out going cables, panels for their terminal tighness and healtyness within sub stn by routine checkup and tightening of nut bolts etc and reporting / giving information to JE/ Engr in charge for any repair work required. (f) Replacement of DO fuse as and when required labour only. (g) Maintaning of record for any Breakdown/shutdown as and when happened in the coplaint register as well as in breackdown resister.NOTE :- (i) Dress with pant, Shirt, cap, Shoes and Identity card shall be provided to Electrician as approved by the Engr-in-Charge and rates quoted will be demed to be included for the same. (ii) The Electrician will be well conversant with HT 11/22 KV and LT 415 V supply system and preventive measures in case of electrical accident and fire fighting system. (iii) T&P required for attending breakdown and emergency complaints shall be provided by the contractor and the rates will be inclusive of quoted rate. (iv) Contractor will provide Bi-cycle if required to electrician for attending breakdown/emergency complaint and rate will be inclusive of quoted rate. (v) Minor items like nuts, bolts,washers and fuses up to Rs 1000/- per month will be considered as minor items and deemed to be included in the quoted rates. (vi) Electrician will not leave the installation untill next shift duty electrician come on duty and handing over / taking over of Key and if any complaint or specific work is pending shall be communicated propely. (vii) Stationary like log book shut down register and other registers shall be maintained by the technician. The required stationary will be supplied by the contractor and no extra payment will be enternained on this account. (viii) Area cleaning including surface dressing of yard area of sub station on daily basis is deemed to be included in the rates quoted.
Same as item No 1 above but for operation and maintenance of HT Receiving station at Main power house "N" bldg 512 ABW including Sunday and holidays Cosisting of two/ four pole structures , transformers ,HT/ LT panels APFC panels 1000 KVA DG sets , 110 KVA DG set, battery banks ,GODs etc by providing suitably qualified and experienced one Electrician having knowlage HT 11/22 KV and LT 415 V supply system and Operation of DG sets with knowlage of preventive measures in case of electrical accident and fire fighting system for three shift and each shift of 8 hours round the clock all as specified and directed by Engr-in-Charge.NOTE :- (i) Dress with pant, Shirt, cap, Shoes and Identity card shall be provided to Electrician as approved by the Engr-in-Charge and rates quoted will be demed to be included for the same. (ii) The Electrician will be well conversant with HT 11/22 KV and LT 415 V supply system and preventive measures in case of electrical accident and fire fighting system. (iii) T&P required for attending breakdown and emergency complaints shall be provided by the contractor and the rates will be inclusive of quoted rate. (iv) Contractor will provide Bi-cycle if required to electrician for attending breakdown/emergency complaint and rate will be inclusive of quoted rate. (v) Minor items like nuts, bolts,washers and fuses up to Rs 1000/- per month will be considered as minor items and deemed to be included in the quoted rates. (vi) Electrician will not leave the installation untill next shift duty electrician come on duty and handing over / taking over of Key and if any complaint or specific work is pending shall be communicated propely. (vii) Stationary like log book shut down register and other registers shall be maintained by the technician. The required stationary will be supplied by the contractor and no extra payment will be enternained on this account. (viii) Area cleaning including surface dressing of yard area of sub station on daily basis is deemed to be included in the rates quoted.
Same as item No 1 above but for operation and maintenance of HT Receiving station at "A" park CAFVD & Arsenal Depot including Sunday and holidays consisting of two pole structure , transformer , LT panels APFC panel etc by providing suitably qualified and experienced one mate (semi skilled helper) having basic knowlage of elctric suplly for two shifts and each shift of 8 hours from 0600 hrs to 2200 hrs to assist the electrision provided at sl No one for all works mentioned in sch all as specified and directed by Engr-in-Charge.
Same as item No 1 above but for operation and maintenance of HT Receiving station at Main power house "N" bldg 512 ABW including Sunday and holidays Cosisting of two/ four pole structures , transformers ,HT/ LT panels APFC panels 1000 KVA DG sets , 110 KVA DG set, battery banks ,GODs etc by providing suitably qualified and experienced one mate (semi skilled helper) having basic knowlage of elctric suplly and DG sets also, for three shifts and each shift of 8 hours round the clock to assist the electrision provided at sl No Two for all works mentioned in sch all as specified and directed by Engr-in-Charge. NOTE FOR item NO 3 & 4 :- (i) Dress with pant, Shirt, cap, Shoes and Identity card shall be provided to mate as approved by the Engr-in-Charge and rate will be inclusive of quoted rate. (ii) The mate should have the basic knowlage HT 11/22 KV and LT 415 V supply system and Operation of DG sets with knowlage of preventive measures in case of electrical accident and fire fighting system.
Supply only DO fuse element 11 KV of 20 amp rating as per existing lenth all as specified.
Supply only DO fuse element 22 KV of 20 amp rating as per existing lenth all as specified.
Supply only DO fuse element 22 KV of 40 amp rating as per existing lenth all as specified.
Supply only DO fuse element 22 KV of 60 amp rating as per existing lenth all as specified.
Supply only DO fuse element 22 KV of 100 amp rating as per existing lenth all as specified.
Supply only DO fuse element 22 KV of 120 amp rating as per existing lenth all as specified.
M&L for maintaning of MES Electric supply installations / campus by surface dressing or trimming of natural ground to remove small unequalities n.exc 15 cm deep ( including removing vegetation / shrubs / brush wood / under-growth & carrying away the rubbish to a distance of n.exc 50 mtr away complete.
Disconnecting HT/LT XLPE cable of any size from structure/pole /transformer/ MOCB/ LT Panel for finding fault, M&L for defect rectification HT/LTcable laid in trenches or any location by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additional excavation in normal or any type of strata required for exposing the cable fault and keeping the same ready for jointing work for cable of any size. The fault locating equipments will be brought to site within the 6 hours of instruction from Engr-in-Charge as specified. Note :- Complaint will be notified to contractor on mobile phone at any time between 0800 hrs to 2200 hrs and has to be rectified within 8 hours after notification, failing to which Rs 500/- per day per complaint will be recovered.
M&L in repairs Heat shrinkable outdoor type end termination cable jointing kit suitable for earthed 3 core 120/185 sqmm HT 22KV XLPE aluminium conductor cable incld. disconnecting concerned cable, cutting out burnt/damaged jointing kit, jointing new kit inld. testing and commissioning of the complete cable to the complete satisfaction of Engr-in-Charge all as specified and directed. Make:- Raychem/M-Seal/Denson. NOTE- a. The quoted rate is deemed to be inclusive of cost of saddling or clamping of cable all as directed by Engr-in-Charge. b. Contractor has to arrange proper electrical shutdown after informing to depratment concerned.
All as per Item No. 13 above but Heat shrinkable indoor type end termination cable jointing Kit .
All as per Item No. 13 above but Heat shrinkable outdoor type end termination cable jointing Kit suitable for earthed 3 core 95 Sqmm HT 11kV XLPE aluminium conductor cable.
All as per Item No. 13 above but Heat shrinkable indoor type end termination cable jointing Kit suitable for earthed 3 core 300 sqmm HT 22KV XLPE aluminium conductor cable.
All as per Item No. 13 above but Heat shrinkable outdoor type end termination cable jointing Kit suitable for earthed 3 core 300 Sqmm HT 22kV XLPE aluminium conductor cable.
M&L in repairs Heat shrinkable straight through cable jointing kit suitable for earthed 3 core 185/120 sqmm HT 22KV XLPE aluminium conductor cable incld. disconnecting concerned cable, cutting out burnt/damaged jointing kit, jointing new kit inld. testing and commissioning of the complete cable to the complete satisfaction of Engr-in-Charge all as specified and directed. Make:- Raychem/ XICON/ M-Seal/Denson. NOTE- (a). The quoted rate is deemed to be inclusive of cost of saddling or clamping of cable all as directed by Engr-in-Charge. (b). Contractor has to arrange proper electrical shutdown after informing to depratment concerned. (c). Cost of connected excavation, soil removal, returning filling in, sand cusshioning and cable covers will be measured and paid in the respective items of the Schedule.
All as per Item No.18 above but straight through cable jointing kit suitable for earthed 3 core 300 sqmm HT 22KV XLPE aluminium conductor cable.
M&L for cleaning of MES Electric supply installations / campus/ site clearance by removing vegetation / shrubs / brush wood / under-growth & carrying away the rubbish to a distance of n.exc 50 mtr away complete at an interval of every 45 to 50 days for the following installations: - (Note: One job will be considered for cleaning in one month)
Sub station at "A" park approx area 75 sqm.
Sub station "metering quioske & 2 pole structure" at "A" park approx area 66 sqm
Sub station Arsenal Depot near moisture proof approx area 135 sqm
Sub station "Arsenal Depot near Armoury" approx area 350 sqm
Sub station DRDC approx area 160 sqm
Sub station "A" at 512 ABW approx area 380 sqm
Sub station "B" at 512 ABW approx area 250 sqm
Sub station "C" at 512 ABW approx area 650 sqm
Sub station "D" at 512 ABW approx area 200 sqm
Sub station "VRD PT one" at 512 ABW approx area 180 sqm
Sub station "MA bldg" at 512 ABW approx area 50 sqm
Sub station "159 bldg" at 512 ABW approx area 50 sqm
Sub station "ETD bldg" at 512 ABW approx area 30 sqm
Sub station "metering quioske & 4 pole structure" at 512 ABW approx area 450 sqm
N bldg main power house back side area including earthing pit area aprox 130 sqm
N bldg main power housecooling tower and mandir side area aprox 300 sqm
M&L for dismantling of existing indoor type panel with MS stand/rack including disconnecting of incoming and out going cables gland lugs/thimbles, etc carefully so that the same can be reconnected to new panel. and Supply, fix & testing LT panel-TTA (Totally type tested) indoor IP54 , factory made, single front,fix type,Foor mounted panel with aluminium bus bar of suitable size, panel fabricated with 2.0 mm CRCA sheet for load bearing members &1.6 mm thick sheet for non load bearing members . Panels shall be Suitable for following incoming & outgoing , including accessories and making conections of incoming and outgoing cables, tobe fixed on concrete base or on cable duct with neccessory angle iron base frame duly painted and fixing material like fastner nut,bolt etc cable entry from back/bottom side as per site requirement complte all as specifide and directed.
INCOMER
MCCB 4P, 25 kA, 125 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, with spreader links and insulating shields Make - Legrand, Cat No. - 420056 . /L&T /ABB/
OUTGOINGS
MCCB TP, 25 kA, 63 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In,with spreader links and insulating shields Make - Legrand, Cat No. - 420043. /L&T /ABB/
MCCB TP, 16 kA, 40 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, with spreader links and insulating shields Make - Legrand, Cat No. - 420002./L&T /ABB/
MCB four pole 6 to 32 Amps, 415 volts, 10 kA breaking capacity, 'C' curve 2 Nos Make Legrand Ct No 4086/99.- /L&T /ABB/
All as per Item No.21 above but suitable for and including following accessories
INCOMER
MCCB 4P, 36 kA, 250 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, with spreader links and insulating shields Make - Legrand, Cat No. - 420249. /L&T /ABB
OUTGOINGS
MCCB TP, 25 kA, 63 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In,with spreader links and insulating shields Make - Legrand, Cat No. - 420043. /L&T /ABB
MCCB TP,25 kA,100 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, with spreader links and insulating shields Make - Legrand, Cat No. - 420045. /L&T /ABB
MCB four pole 6 to 32 Amps, 415 volts, 10 kA breaking capacity, 'C' curve 2 Nos Make Legrand Ct No 4086/99.- /L&T /ABB/
All as per Item No.21 above but suitable for and including following accessories
INCOMER
MCCB 4P, 36 kA, 250 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, with spreader links and insulating shields Make - Legrand, Cat No. - 420249. /L&T /ABB
OUTGOINGS
MCCB TP, 25 kA, 63 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, with spreader links and insulating shields Make - Legrand, Cat No. - 420043. /L&T /ABB
MCCB TP,25 kA,100 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, with spreader links and insulating shields Make - Legrand, Cat No. - 420045. /L&T /ABB
MCB four pole 6 to 32 Amps, 415 volts, 10 kA breaking capacity, 'C' curve 2 Nos Make Legrand Ct No 4086/99.- /L&T /ABB/
All as per Item No.21 above but outdoor type IP 65/66 suitable for and including following accessories
INCOMER
MCCB 4P, 36 kA,400 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, with spreader links and insulating shields Make - Legrand, Cat No. - 422007. /L&T /ABB/C&S 2 Nos
Change over switch 630 Amps , 4 pole open extruded, panel mounted front operated with operating handle complete as per L&T make type CO04-630 Cat part No CO46300OOOO /C&S/ABB
OUTGOINGS
MCCB TP, 36 kA,320 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, with spreader links and insulating shields Make - Legrand, Cat No. - 422001. /L&T /ABB/C&S
MCCB TP, 50 kA, 250 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, with spreader links and insulating shields Make - Legrand, Cat No. - 420239. /L&T /ABB
Modification to existing panel board having 03 Nos 800 Amps cap ACBs, 02 Nos incoming and 01 NO outgoing to 02 Nos incoming and 02 Nos ourging and 01 No ACB as buscoupler by modification to aluminium bus bar for 3 phase and 100 % neutral of existing size busbars and providing mechanical iterlocking to ACBs so that buscoupler ACS should not be gate ON unless any one incoming ACB is gate OFF including diconnecting and reconnecting of incoming and outgoing cables(aprox 15 NOs) including replacement or modification to cable end and suitable size lugs & GI nutbolts required at site to complete the job all as specified and directed and to the satishfaction of Engr-in-charge. NOTE : (i) the modification to be done at site. (ii) Job should be done on sunday / holiday with proper shutdoun to intimated at least two days inadvance.(ii) The neccessory T&P required to be arranged by the contractor.
metro electrical services
Apurva constructions
M/S VR Construction Services
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .