| 1 | L1₹37.6 LAccepted-Finance GSTIN: 09ABAFR9195G1ZPNEAR PUMP HOUSE ROAD NEAR RED ROSE SCHOOL BABINA CANTT JHANSI DISTT UP 284401 | JHANSI | UTTAR PRADESH | 284001 | ₹37.6 L | L1 | Accepted-Finance Being L1 |
| 2 | L2₹37.8 LRejected-Finance GSTIN: 09AAWFR2578J1Z9A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | ₹37.8 L | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹38.2 LRejected-Finance 1010 NANDANPURA BABINA CANTT DIST JHANSI 284401 | BABINA CANTT | JHANSI | UTTAR PRADESH | 284401 | ₹38.2 L | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹38.5 LRejected-Finance GSTIN: 09AVFPS0703G1ZP, 09BAIPA7343B1Z2, 09BKAPK9204P1ZQ, 20DMTPS9681D1ZH, 20DMTPS9681DIZH, 36AGAPV7579B1Z30 BISAI TIKAITGANJ FATEHPUR BARABANKI UTTAR PRADESH 225302 | BARABANKI | UTTAR PRADESH | 225302 | ₹38.5 L | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹38.9 LRejected-Finance GSTIN: 09ARPPS5237H1Z61308 MAIN ROAD BABINA CANTT JHANSI U P | JHANSI | JHANSI | UTTAR PRADESH | ₹38.9 L | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | VIJAY BUILDERS L6 | ROHIT ENTERPRISES L2 | M/S RAJ KUMAR SINGH L5 | M/S Ritu Tandon L1 | M/S Kumar Contractors L8 | M/S M S Constructions L3 | ADARSH ENTERPRISES L4 | RAVI TRADERS L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.01 | S&F MCB in replacement of TPN 63 Amps 240 V,10KA, 'C' series, with copper lugs complete all as specified and directed . Make :- Havells / ABB/ Indoasian /HPL/ Legrand | 10 | Each | 1,800 ₹18,000 | 3,500 ₹35,000 | 2,200 ₹22,000 | 400 ₹4,000 | 755 ₹7,550 | 1,800 ₹18,000 | 1,250 ₹12,500 | 1,350 ₹13,500 |
| 2.01 | S&F MCB in replacement of TPN 100 Amps 240 V, 16KA, 'C' series, with copper lugs complete all as specified and directed . Make :- Havells / ABB/ Indoasian /HPL/ Legrand | 10 | Each | 2,600 ₹26,000 | 3,800 ₹38,000 | 2,700 ₹27,000 | 510 ₹5,100 | 855 ₹8,550 | 2,000 ₹20,000 | 1,450 ₹14,500 | 2,200 ₹22,000 |
| 3.01 | S&F MCB in replacement of TPN 125 Amps 240 V, 16KA, 'C' series, with copper lugs complete all as specified and directed Make :- Havells / ABB/ Indoasian /HPL/ Legrand | 5 | Each | 3,300 ₹16,500 | 4,200 ₹21,000 | 3,500 ₹17,500 | 1,500 ₹7,500 | 1,105 ₹5,525 | 2,200 ₹11,000 | 1,750 ₹8,750 | 3,000 ₹15,000 |
| 4.01 | S&F in repair/replacement of Circuit/submain wiring alongwith earth wire 2 runs x 1.5 sqmm + 1 run x 1.5 sqmm with FRLS-H PVC insulated unsheathed 1100 volts grade copper conductor, single core multi stranded cable drawn through and including medium grade rigid PVC conduit not less than 20 mm dia (Existing / new) conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers lugs etc of suitable size but not less than 20 mm concealed in wall/ floor etc including taking down old U/S submain wiring complete all as specified and directed by Engineer-in-Charge. Make :- Finolex/Havells/HPL/Anchor. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length. | 100 | RM | 40 ₹4,000 | 28 ₹2,800 | 36 ₹3,600 | 39 ₹3,900 | 58 ₹5,800 | 40 ₹4,000 | 35 ₹3,500 | 45 ₹4,500 |
| 5.01 | All as per srl item No. 4 here-in-before but of size 2 runs x 2.5 Sqmm + 1 run x 2.5 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length | 180 | RM | 50 ₹9,000 | 46 ₹8,280 | 46 ₹8,280 | 60 ₹10,800 | 89 ₹16,020 | 50 ₹9,000 | 42 ₹7,560 | 68 ₹12,240 |
| 6.01 | All as per srl item No. 4 here-in-before but of size 2 runs x 4 Sqmm + 1 run x 4 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length | 350 | RM | 155 ₹54,250 | 180 ₹63,000 | 86 ₹30,100 | 95 ₹33,250 | 165 ₹57,750 | 120 ₹42,000 | 136 ₹47,600 | 140 ₹49,000 |
| 7.01 | All as per srl item No. 4 here-in-before but of size 2 runs x 6 Sqmm + 1 run x 6 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length | 600 | RM | 225 ₹1.4 L | 200 ₹1.2 L | 110 ₹66,000 | 165 ₹99,000 | 220 ₹1.3 L | 145 ₹87,000 | 178 ₹1.1 L | 170 ₹1.0 L |
| 8.01 | All as per srl item No. 4 here-in-before but of size 2 runs x 10 Sqmm + 1 run x 10 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length | 100 | RM | 270 ₹27,000 | 240 ₹24,000 | 139 ₹13,900 | 165 ₹16,500 | 235 ₹23,500 | 160 ₹16,000 | 200 ₹20,000 | 220 ₹22,000 |
| 9.01 | S & F in repair/replacement Regid non-metallic PVC conduit medium grade not less than 20 mm dia (external) ISI marked (concelaled or surface as per site requirement) incl of all accessories and all fittings such as Tees,bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers,lock nuts, saddles, pipe hook etc complete including cutting necessary chases on wall/ceiling surfaces for drawing of conduit and making good disturbed surfaces of wall with CM 1:3:4 and matching with the existing surfaces including colour washing all as specified and as directed | 1,000 | RM | 33 ₹33,000 | 23 ₹23,000 | 20 ₹20,000 | 30 ₹30,000 | 17 ₹17,000 | 30 ₹30,000 | 32 ₹32,000 | 20 ₹20,000 |
| 10.01 | All as per srl item No. 9 here-in-before but of casing capping complete all as specified and directed. | 100 | RM | 46 ₹4,600 | 32 ₹3,200 | 40 ₹4,000 | 40 ₹4,000 | 22 ₹2,200 | 35 ₹3,500 | 26 ₹2,600 | 30 ₹3,000 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
4 May 2026, 6:00 pmClosed
GE Babina
GE Babina PIN-284401
COMPREHENSIVE REPAIR/MAINT/REPLACEMENT OF UNSV WIRING,INTERNAL ELECTRIC FIXTURES,ELECTRIC METERS AND OTHER CONNECTED E/M WORK IN MD ACCN AT KLP AND ADJOINING AREA UNDER GE BABINA
2026_MES_760037_1
8504/E8
Open Tender
Electrical and Maintenance Works
270 days
GE Babina
As per tender documents
8 documents required · 8 mandatory
₹500
GE Babina
₹80,000
Yes
3 Jun 2026
11 Apr 2026
6 May 2026
11 Apr 2026
4 May 2026
27 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
S&F MCB in replacement of TPN 63 Amps 240 V,10KA, 'C' series, with copper lugs complete all as specified and directed . Make :- Havells / ABB/ Indoasian /HPL/ Legrand | - | Each | - | - | |
S&F MCB in replacement of TPN 100 Amps 240 V, 16KA, 'C' series, with copper lugs complete all as specified and directed . Make :- Havells / ABB/ Indoasian /HPL/ Legrand | - | Each | - | - | |
S&F MCB in replacement of TPN 125 Amps 240 V, 16KA, 'C' series, with copper lugs complete all as specified and directed Make :- Havells / ABB/ Indoasian /HPL/ Legrand | - | Each | - | - | |
S&F in repair/replacement of Circuit/submain wiring alongwith earth wire 2 runs x 1.5 sqmm + 1 run x 1.5 sqmm with FRLS-H PVC insulated unsheathed 1100 volts grade copper conductor, single core multi stranded cable drawn through and including medium grade rigid PVC conduit not less than 20 mm dia (Existing / new) conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers lugs etc of suitable size but not less than 20 mm concealed in wall/ floor etc including taking down old U/S submain wiring complete all as specified and directed by Engineer-in-Charge. Make :- Finolex/Havells/HPL/Anchor. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length. | 200 | RM | - | - | |
All as per srl item No. 4 here-in-before but of size 2 runs x 2.5 Sqmm + 1 run x 2.5 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length | 180 | RM | - | - | |
All as per srl item No. 4 here-in-before but of size 2 runs x 4 Sqmm + 1 run x 4 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length | 350 | RM | - | - | |
All as per srl item No. 4 here-in-before but of size 2 runs x 6 Sqmm + 1 run x 6 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length | 800 | RM | - | - | |
All as per srl item No. 4 here-in-before but of size 2 runs x 10 Sqmm + 1 run x 10 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length | 100 | RM | - | - | |
S & F in repair/replacement Regid non-metallic PVC conduit medium grade not less than 20 mm dia (external) ISI marked (concelaled or surface as per site requirement) incl of all accessories and all fittings such as Tees,bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers,lock nuts, saddles, pipe hook etc complete including cutting necessary chases on wall/ceiling surfaces for drawing of conduit and making good disturbed surfaces of wall with CM 1:3:4 and matching with the existing surfaces including colour washing all as specified and as directed | - | RM | - | - | |
All as per srl item No. 9 here-in-before but of casing capping complete all as specified and directed. | - | RM | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.61 MB
8504Tenderdoc.pdf
Tender Documents • 1.34 MB
BOQ_851310.xls
BOQ • 2.03 MB
Download all tender documents and submit your bid