| Sl No | Description | Qty | Unit | SANJEEV ENTERPRISES L2 | Friends fire Engineers L1 |
|---|---|---|---|---|---|
| 1.00 | M&L for comprehensive maintenance of 4 loops addressbale fire alarm system installed at NEW OPD COMPLEX under Base hospital during the period of contract every month with complete testing of Fire alarm Panel , Manual Call Points Wall sounder , buzzer , receiving panel , smoke detector and other connected items complete in all aspect in presence of Engr-in-charge and New OPD Rep to their complete satisfaction.
(i) All works shall be carried out by authorized rep of OEM and all genuine spare part suplied by ORM only, in this regard and MOU between OEM i.e. M/S Honeywell and contractor must be perform. A copy of the same shall be uploaded with tender document.
(ii) Attending all complaints within 24 working hours intimated by Engr-in-Charge.
(iii) Field service report shall be maintained and submitted to the Engr-in-charge after expiry of every month and before submission of RAR .
(iv) The rates quoted by the contractor shall deemed to be inclusive of T&P etc
(v) Major Spares Part(like Control Panel, Smoke Sensor, MCP) that need to be replace shall be measured and paid for separately under respective item of this schedule.
(vi) A damage of Rs 500.00 per complaint per day shall be imposed on contractor, if the complaint shall not attended within 24 Hours of complaint intimated by Engr-in-Charge.
(vii) Contractor also displays his contact number near Fire Alarm Panel and complaint shall be attended immediately within time frame given in particular specification.
(viii)Every month Technician should be check serviceability of Fire detection system and serviceability report of Fire Alarm system shall be submitted by the contractor. | 11 | Each month | 3,46,600 ₹38,12,600 | 29,999 ₹3,29,989 Lowest |
| 2.00 | Supply , Installation , Testing & Commissioning in replacement microprocessor based networkable analogue addressable Fire Alarm control panel The control panel shall have 4 loop notifire fire detection system supports, with two sounder circuit(1 A max) , 2A power supply source, a general relay ( Alarm and Fault),one programmable relay, fixed auxilary output and resettable 24 v 250mA output, two keys and two inputs for programmable function The panel also include 6x40 character LCD display,an integrated USB port for PC programming and an RS485 port for repeters.The panel shall have 240v AC Power supply along with automatic battery charger.The panel shall have configurable via USB Port to PC or memory stick.The Panel shall have dedicated RS232 serial port for optional printer approved by LPCB complete all as specified and directed. | 1 | Each | 5,70,000 ₹5,70,000 | 49,999 ₹49,999 Lowest |
| 3.00 | M&L for Calibration of the fire alarm control panel with necessary program, including functionality testing, accuracy testing, compliance testing, battery testing to ensure proper functioning of smoke detector with accurate detection of smoke complete in all aspect all as specified and directed. | 1 | Each Job | 5,000 ₹5,000 Lowest | 49,999 ₹49,999 |
| 4.00 | Supply , Installation , Testing & Commissioning in replacement Addressble Smoke Detector fully compatible with analogue Addressable Protocol, having removable high performance chamber with Twin fire LED's allow 360 degree viewing, User selectable sensitivity modes 1% to 4.5% obs/m, Incorporate Optical elements,lock mechanism (sensor to base), Electronically addressed, Pulsing/ Non-Pulshing Controlled from panel complete all as specified and directed. | 140 | Each | 3,900 ₹5,46,000 | 2,299 ₹3,21,860 Lowest |
| 5.00 | Supply & Fix in replacement of weatherproof analogue Manual Call point with Integral short circuit Isolator.The call point shall have fast response , Integral short-circuit isolator,Bi-coloured status LED ,Non Frangible element fitted as standerd, surface mounted ,IP67 rated complete all as specified and directed. | 20 | Each | 3,980 ₹79,600 | 499 ₹9,980 Lowest |
| 6.00 | Supply & Fix in replacement of Output Relay Module MI/DCMOE complete all as specified and directed. | 10 | Each | 4,900 ₹49,000 | 2,999 ₹29,990 Lowest |
| 7.00 | Supply & Fix in replacement of Siren 2 km Horizontal/Vertical Single Mounting complete all as specified and directed. | 2 | Each | 4,900 ₹9,800 Lowest | 16,999 ₹33,998 |
| 8.00 | Supply & Fix in replacement of Siren Controller complete all as specified and directed. | 2 | Each | 1,000 ₹2,000 Lowest | 1,799 ₹3,598 |
| 9.00 | Supply & Fix in replacement of Intelligent loop powered wall sounder which provide a range of tones and volumes with a maximum output of upto 102 db with low current consumption, 51 user selectable tones complete all as specified and directed. | 30 | Each | 10,600 ₹3,18,000 | 1,999 ₹59,970 Lowest |
| 10.00 | Supply & Fix in MS enclosure for MCP with all accessories required. | 40 | Each | 4,100 ₹1,64,000 | 399 ₹15,960 Lowest |
Tender Value
Refer Docs
EMD Value
₹89,920
Closing Date
19 Dec 2025, 6:00 pmClosed
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
COMPREHENSIVE MAINT OF SMOKE DETECTOR FIRE ALARM, FIRE HYDRANT SYSTEM AND ALL MISC AND CONPREHENSIVE MAINT OF UPS BATTERY IN VARIOUS WARD, NEW OPD AT BASE HOSP UNDER GE (EAST) DELHI CANTT-10
2025_MES_740155_1
GE/DE-119/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE (EAST) DELHI CANTT-10
Cat (vi)/ Class D
9 documents required · 9 mandatory
₹500
GE (EAST) DELHI CANTT-10
₹89,920
Yes
24 Dec 2025
17 Nov 2025
22 Dec 2025
17 Nov 2025
19 Dec 2025
5 Dec 2025
Amount
M&L for comprehensive maintenance of 4 loops addressbale fire alarm system installed at NEW OPD COMPLEX under Base hospital during the period of contract every month with complete testing of Fire alarm Panel , Manual Call Points Wall sounder , buzzer , receiving panel , smoke detector and other connected items complete in all aspect in presence of Engr-in-charge and New OPD Rep to their complete satisfaction. (i) All works shall be carried out by authorized rep of OEM and all genuine spare part suplied by ORM only, in this regard and MOU between OEM i.e. M/S Honeywell and contractor must be perform. A copy of the same shall be uploaded with tender document. (ii) Attending all complaints within 24 working hours intimated by Engr-in-Charge. (iii) Field service report shall be maintained and submitted to the Engr-in-charge after expiry of every month and before submission of RAR . (iv) The rates quoted by the contractor shall deemed to be inclusive of T&P etc (v) Major Spares Part(like Control Panel, Smoke Sensor, MCP) that need to be replace shall be measured and paid for separately under respective item of this schedule. (vi) A damage of Rs 500.00 per complaint per day shall be imposed on contractor, if the complaint shall not attended within 24 Hours of complaint intimated by Engr-in-Charge. (vii) Contractor also displays his contact number near Fire Alarm Panel and complaint shall be attended immediately within time frame given in particular specification. (viii)Every month Technician should be check serviceability of Fire detection system and serviceability report of Fire Alarm system shall be submitted by the contractor.
Supply , Installation , Testing & Commissioning in replacement microprocessor based networkable analogue addressable Fire Alarm control panel The control panel shall have 4 loop notifire fire detection system supports, with two sounder circuit(1 A max) , 2A power supply source, a general relay ( Alarm and Fault),one programmable relay, fixed auxilary output and resettable 24 v 250mA output, two keys and two inputs for programmable function The panel also include 6x40 character LCD display,an integrated USB port for PC programming and an RS485 port for repeters.The panel shall have 240v AC Power supply along with automatic battery charger.The panel shall have configurable via USB Port to PC or memory stick.The Panel shall have dedicated RS232 serial port for optional printer approved by LPCB complete all as specified and directed.
M&L for Calibration of the fire alarm control panel with necessary program, including functionality testing, accuracy testing, compliance testing, battery testing to ensure proper functioning of smoke detector with accurate detection of smoke complete in all aspect all as specified and directed.
Supply & Fix in replacement of weatherproof analogue Manual Call point with Integral short circuit Isolator.The call point shall have fast response , Integral short-circuit isolator,Bi-coloured status LED ,Non Frangible element fitted as standerd, surface mounted ,IP67 rated complete all as specified and directed.
Supply & Fix in replacement of Output Relay Module MI/DCMOE complete all as specified and directed.
Supply & Fix in replacement of Siren 2 km Horizontal/Vertical Single Mounting complete all as specified and directed.
Supply & Fix in replacement of Siren Controller complete all as specified and directed.
Supply & Fix in MS enclosure for MCP with all accessories required.
Supply & Fix in addressable MCP with enclosure and all accessories required.
Supply & Fix in addressable Loop card with enclosure and all accessories required.
Supply & Fix in Fire Alarm Panel Battery of 12V , 7Ah complete in all aspect all as specified and as directed. Make : Exide/ Amaron/ V-Guard.
M&L for comprehensive maintenance and repair including replacement of defective parts/fittings including all electronics and electrical spares required for comprehensive maintenance during the entire contract period through AMC of 30 KVA Online UPS System (details mentioned below in NOTE:-1) (Make-VERTIV) installed at various wards/area under base hospital during the period of contract every month. NOTE -1 1.Dental Deptt. -01 No 2.Dialysis Dept.- 01 No. 3.New OPD- 01 No. 4.Dialysis- 01 No 5.GE Center- 01 No 6.OT Complex- 01 No 7. Open Heart Plant - 01 No 8. Trauma Center -01 No 9.Labour Room- 01 No 10. Covid ICU- 01 No 11. Eye OT - 01 No 12.ICU- 01 No
Note - 2 (i) All work shall be carried out only by authorised Rep of OEM and using all genuine spare parts supplied by OEM only, in this regard an MOU between OEM i.e M/S VERTIV and the Contrcator must be perform ,A copy of the same MOU shall be uploaded with the tender document . (ii) Contractor should be responsible of proper functioning of all the machine from current condition (either in malfunctioning or working) in the initial phase of contract and rate for for the same shall be included in the quoted. Nothing extra in that respect shall be paid to the contractor in any respect. (iii) Batteries for the UPS if required shall be paid (ii) Contractor through OEM shall be responsible for repair and replacement of all defective parts of the equipment as per OEM recommendation during entire comprehensive maintenance period.Quoted rate shall deemed to be inclusive of replacement of all defective parts and including periodical painting, if any required to maintain smooth functining of equipments,control and power wiring, replacement of all consumable items. Nothing extra in that respect shall be paid to ti the contractor in any respect. (iii) Preventive maintenance of all systems on monthly basis and upkeep of log book. (iv) Attending all complaints within 24 working hours intimated by Engr-in-Charge. (v) Field service report shall be maintained and submitted to the Engr-in-charge after expiry of every month and before submission of RAR . (vi) The rates quoted by the contractor shall deemed to be inclusive of T&P etc (vii) A damage of Rs 500.00 per complaint per day shall be imposed on contractor, if the complaint shall not attended within 24 Hours of complaint intimated by Engr-in-Charge. (viii) Contractor also displays his contact number near UPS System and complaint shall be attended immediately within time frame given in particular specification. (ix)Every month Technician should be check serviceability of UPS and serviceability report of Fire Alarm system shall be submitted by the contractor.
Supply & fixing in Replacement Sealed Maintenance Free 12V/65AH Batteries with suitable size terminal link for 30 KVA UPS. (Make:Exide/Amaron/V-Guard)
M&L comprehensive maintenance of FIRE Fighting /Fire Hydrant system installed at NEW OPD COMPLEX under Base hospital during the period of contract every month with complete testing of Fire hydrant system including Fire Pump, Hydronumetic System, valve , vessle, sprinkler and other connected items complete in all aspect in presence of Engr-in charge and New OPD Rep to their complete satisfaction. (i) Preventive maintenance of all systems on monthly basis and upkeep of log book. (ii) Attending all complaints within 24 working hours intimated by Engr-in-Charge. (iii) Field service report shall be maintained and submitted to the Engg-incharge after expiry of every month and before submission of RAR . (iv) The rates quoted by the contractor shall deemed to be inclusive of T&P etc (v) A damage of Rs 500.00 per complaint per day shall be imposed on contractor, if the complaint shall not attended within 24 Hours of complaint intimated by Engr-in-Charge. (vi) Contractor also displays his contact number near Fire Alarm Panel and complaint shall be attended immediately within time frame given in particular specification. (vii) Every month Technician should be check serviceability of Fire detection system and serviceability report of Fire Alarm system shall be submitted by the contractor.
S&F upright pendent glass bulb type sprinkler (standerd response) as per IS :15106/TAC for 68 degree of operation complete in all aspect all as specified and as directed.
S&F sprinkler rossette 25 mm dia complete in all aspect all as specified and as directed.
S&F Sprinkler flexible type 1m size comple in all aspect all as specified and as directed.
S&F Sprinkler flexible type 1.5m size comple in all aspect all as specified and as directed.
Supply, laying, jointing and testing of MSERW Sprinkler Pipe of size 25 mm including suitable size of Tee, socket ,union and neccesary T&p complete in all aspect all as specified and directed.
Supply, laying, jointing and testing of MSERW Sprinkler Pipe of size 40 mm including suitable size of Tee, socket ,union and neccesary T&p complete in all aspect all as specified and directed.
Supply, laying, jointing and testing of MSERW Sprinkler Pipe of size 50 mm including suitable size of Tee, socket ,union and neccesary T&p complete in all aspect all as specified and directed.
Supply, laying, jointing and testing of MSERW Sprinkler Pipe of size 65 mm including suitable size of Tee, socket ,union and neccesary T&p complete in all aspect all as specified and directed.
Supply, laying, jointing and testing of MSERW Sprinkler Pipe of size 150 mm including suitable size of Tee, socket ,union and neccesary T&p complete in all aspect all as specified and directed.
Supply and fix in replacement fire brigade inlet connection 2 way complete in all aspect all as specified and as directed.
Supply and fix in replacement hose reel drum of 36 m size complete in all aspect all as specified and as directed.
Supply and Fix in replacement branch pipe gun metal 63 m instantaneous inlet,made threaded outlet,15 mm bore nozzle short complete in all aspect all as specified and as directed.
S&F sluice valve 100mm bore class-1 ISI marked confirming to IS-14846 flanged ends drilled pressure rating PN 1.0 having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gasket including jointing and testing including taking out old unserviceable complete all as specified and directed. Make : Kirloskar/ Tata.
S&F 80 mm bore hand operated butterfly valve of pressure capacity not less than 15 kg/sqm with complete set all as specified and as directed. Make : Kirloskar/ Tata.
S&F 200 mm bore hand operated butterfly valve of pressure capacity not less than 15 kg/sqm with complete set all as specified and as directed. Make : Kirloskar/ Tata.
M&L for Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glass door frame made of 16 gauge MS sheet duly painted fire red out side and brilliant white inside yard including taking out old unserviceable complete all as specified & directed.
M&L for replacement of Power contactor, 3 pole, MNX 50 type (AC3 rating 22 Amp and AC1 rating 32 Amp of make L & T/ ABB/ C & S including taking down old & unserviceable complete all as specified and directed.
M&L for replacement of Power contactor, 3 pole, MNX 70 type (AC3 rating 22 Amp and AC1 rating 32 Amp as L & T/ ABB/ C & S including taking down old & unserviceable complete all as specified and directed.
M&L for replacement of Power contactor, 4 pole, MCX02 type 25 Amp rating Make : L & T/ ABB/ C & S including taking down old & unserviceable complete all as specified and directed.
M&L for replacement of Power contactor, 4 pole, MCXA1 type Make L & T/ ABB/ C & S including taking down old & unserviceable complete all as specified and directed.
M&L for replacement of Power contactor, 4 pole, MCXA2 type Make L & T/ ABB/ C & S including taking down old & unserviceable complete all as specified and directed.
M&L for painting of complete Pump House including all assest pump motor and pipe lines in double coat fire resistance paint to proper satisfaction of Engg-in-charge complete in all aspect all as specified and as directed.
M&L for replacement of Bimetal Over load Relay, 3 pole, MN-2 direct mounting on MNX-22 type of relay range 14-23 Amp as per Cat No SS94144OODO of make L & T/ ABB/ C & S including taking down old & unserviceable complete all as specified and directed.
M&L for replacement of Star Delta Timer MICON 225 3-120s 240 V AC complete in all aspect including taking down old & unserviceable complete all as specified and directed. Make : L & T/ ABB/ C & S.
M&L for Single Phase Preventer, VSP2 type, 415 volts, 50 Hz including taking down old & unserviceable complete all as specified and directed. Make : L & T/ ABB/ C & S.
Supply, fixing and connecting in replacement recessed mounting back- lit LED 2'X2', 36 watt tile in CRCA housing with full opal diffuser suitable for Armstrong/ Grid Ceilings Type, size 595X595mm (Nominal),High lumen efficacy LED with viewing angle of 120 degree used to enhance the luman output Height suitable for White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection minimum 2.5KV, safety & performance test as per IS:15885 Total system Lumen not less than 3600, in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80 with Average life of 50000 Burning hours complete with all accessories as required complete all as specified and as directed. Make : Havells/ Bajaj/ Philips.
S&F 120 watt LED street light fitting complete in all aspect all as specified and as directed.
M&L dismantalling of Electric motor driven centrifugal pump motor from base plate inside and arranging the necessory adjusting from fan belt, and then repairing /servicing Motor, capacity 45 KW , opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed Note: The quoated rates must incl. loading & unloading with to and fro transportation for workshop and vice versa.
Repair , Overhauling & servicing of 3 phase 415 Volt 180 LPM 2900 RPM 70 m head capacity 5.50 HP /4 KW centrifugal multi stage electric driven jockey pump complete all as specified & directed.
S&F in replacement Pressure gauge of 100 mm dia range 0 to 21 kg/sqcm dual scale of 300 PSI accuracy 1% on full scale deflection complete all as specified and as directed.
S&F in replacement Pressure switch Range-0.2 to 7.5 Bar, IP 30 complete in all aspect all as specified and as directed.
S&F in replacement MCCB 40Amp rating 415 V 16 KA, 4 Pole 40 Amp complete in all aspect all as specified and as directed. Make : L & T/ ABB/ C & S.
S&F in replacement MCCB 160 Amp rating 415 V 16 KA, 4 Pole 40 Amp complete in all aspect all as specified and as directed. Make : L & T/ ABB/ C & S.
SANJEEV ENTERPRISES (BID ID -3495422)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
Tender119.pdf
Tender Documents • 1.10 MB
BOQ_828783.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .