Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC 1723 GUPTA AND SONS SECTOR 39 B CHANDIGARH CHANDIGARH CHANDIGARH 160036 UDYAM CH 01 0042756 | CHANDIGARH | CHANDIGARH | 160036 | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.0 L+₹25,825.20 (1.37%)Rejected-Finance 691 INDUSTRIAL AREA PHASE II CHANDIGARH 160 002 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160002 | L2 | Rejected-Finance Not Being L1 |
Tender Value
₹20.8 L
EMD Value
₹41,600
Closing Date
23 Mar 2021, 6:00 pmClosed
Sh Bharat Lal IDSE EE SG GE P
GE (P) CH Chandimandir
REPAIR REPLACEMENT AND MAINT OF BUS TRUNKING SYSTEM FEEDER PILLERS AND OVERHAULING OF TRANSFORMER UNDER GE P CH CHANDIMANDIR
2021_MES_424474_1
GE (P) CH/CHM-29/2020-21
Open Tender
Miscellaneous Works
Item Wise
180 days
GE (P) CH Chandimandir
Class D Cat b(i)
9 documents required · 9 mandatory
₹500
Yes
GE (P) CH Chandimandir
₹41,600
Yes
28 Jun 2021
23 Feb 2021
25 Mar 2021
23 Feb 2021
23 Mar 2021
9 Mar 2021
Amount
Taking down existing trunking bus bar of capacity 800/315 Amp from switch rooms of three floors of Comd Hosp and deposited to MES Store yard .
Supply and fixing sandwich rising mains of capacity 800A , 50 KA , SC for 1 Sec , 4 poles (3 Phase 4 wire system ) of aluminium bus bars with 50% integral G.I housing earthi , bus trunking enclosures shall be made of 1.6 mm thick electro galvanised GI Sheet degree of protection IP 54 , multi layer insulation of Class F, temprature rise as per IEC 61439- 1&6 , vertical supports , Spring hanger , rigid hanger , end cover (of Make : C&S / ABB/ Schnieder/ L&T/ Seimens ) with following :
Plug in hole
End feed unit box of capacity 800A with provision of MCCB but without MCCB Complete all as specified and directed . Make : C&S /ABB/ Schnieder/ L&T
Plug in type tap off boxes of capapcity 400A with proviswion of MCCB but without MCCB Complete all as specified and directed . Make : C&S /ABB/ Schnieder/ L&T
Compact air insulated rising main having of capacity 315A , 25 KA , SC for 1 Sec with enclosure made up of 1.6 mmm GI sheet duly powder coated , 4P aluminium bus bars in convenient sections with support of F insulation at suitable distance suitable for 415 V , 50 Hz Ac , icluding vertical brakets , and end covers Complete all as specified and directed . Make : C&S /ABB/ Schnieder/ L&T
End feed unit box with provision of MCCB suitable for compackt air insulated bus bar of capacity 315A Complete all as specified and directed . Make : C&S /ABB/ Schnieder/ L&T
TPN tap off boxes of capacity 125A with provision of MCCB Complete all as specified and directed . Make : C&S /ABB/ Schnieder/ L&T.
MCCB 800A 65KA 4 adjustable thermal magnetic release complete all as specified and directed . Make : ABB/C&S/ Siemens/ Schneider
Spreaders link for 800 Amps 4P
Extended rotary handle for 800 A MCCB
MCCB 400A 36AKA 4P adjustable thermal magnetic release complete all as specified
Spreader link for 315A 4P
Extended rotary handle for 315A
MCCB 125A 36KA 4P adjustable thermal magnetic release Complete all as specified and directed . Make : C&S /ABB/ Schnieder/ L&T
Spreader links for 125A 4P
Extended rotary handle for 125A
PCC 1:2:4 type B1 using 20mm graded aggregate in above GL including breaking existing PCC and removing from site complete all as specified and directed.
XLPE insulated stranded aluminium conductor of size 400 Sqmm 3.5 core, 1100 Volts grade screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) including taking out existing unsv cable complete all as specified and directed.
Supply, install, commission and testing cubical type LT panel board of size 1.5 x 1.5 x 0.50 mtr, Outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of 50X50 x 6mm MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands and including taking down existing suitable to equiped complete all as specified and directed with the following accessories
Supply,install, commission and testing cubical type LT panel board of size 1.5 x 1.5 x 0.50 mtr, Outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of 50X50 x 6mm MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands and including taking down existing suitable to equiped complete all as specified and directed with the following accessories :-
Supply, install, commission and testing cubical type LT panel board of size 1.5 x 1.5 x 0.50 mtr, Outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement made of 50X50 x 6mm MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands and including taking down existing suitable to equiped complete all as specified and directed with the following accessories :-
Refixing the existing LT panel to new location complete including dismantling from old location and transportaiton , shifiting to new location , PCC for foundation , cleaning of existing panel , painting with two coat of synthetic enamled paint complete all as specified and directed.
Transformer of capapcity upto and including 250 KVA for arresting leakage form the transformer body, repalcement of unserviceable LV/HV bushing / tank gasket etc including changing of oil seal and gasket etc testing and commissioning and provisionig of all toolsand plants required for dismantlingof transformer body , all as specified and directed . (Note : The LV/HV bushing , brass stud and other parts required shall be measureing and paid for separately under relevant items of schedule )
All as per items No 27 above but of capacity 500KVA complete all as specified and directed
All as per items no 27 above but of capacity 1600KVA complete all as specified and directed
LV Bushing of transformer upto 250KVA capacity including taking down old unserviceable bushing complete all as specified and directed
LV Bushing of transformer upto 500KVA capacity including taking down old unserviceable bushing complete all as specified and directed
LV Bushing of transformer upto 1600KVA capacity including taking down old unserviceable bushing complete all as specified and directed
HV Bushing of transformer upto 1600KVA capacity including taking down old unserviceable bushing complete all as specified and directed
HV Bushing of transformer 250 KVA to 500KVA capacity including taking down old unserviceable bushing complete all as specified and directed.
Breather with new silica gel of transformer 250 KVA 1600KVA capacity including taking down old unserviceable breather complete all as specified and directed.
Dehydration of transformer oil with mobile transformer filteration plant at site with required accessories connectedto transformer and carrying out filteration of old transformer oil for the desired dielectric strengh of 50 KV 2.5mm gap complete all as specified and directed
Topping up/ replacement of transformer oil with new transformer oil suitable for working voltage 11000 volts grade including necessary dehydration to achieve dielectric strength min 50KV at 2.5mm gap complete all as specified and directed. Make : Gulf/ castrol/HP/Power
Glass & gasket of conservator of transformer of capacity 250 KVA to 1600KVA after draining the oil and refilling after filteration complete all as specified and directed.
Drain valve of suitable size for transformers of capacity 250KVA to 1600 KVA after draining transformer oil and refilling and filtering the oil after completition of work with portable filteration machine to get the required oil value complete all as specified and directed.
Maintenance and servicing of HT witch gear 11KV 800Amp VCB (Make ABB) Maintenance job mainly comprising of the following :- (I) Isolating VCB truck and checking of free movement for closing and withdrawing (II) Examination of insulating component (III) Testing of primary and secandary circuit with megger for insulation resistance (IV) cleaning and wiping down of busbar phase barriors support and sleeves (VI) tightening of nuts and bolts complete all as specified and directed .
Earthing with 600 x 600 x 6mm galvanised steel earth plate electrode buried verticaly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge not less than 1.5m below ground level, connected to and including GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of galvanised steel (and 50mm dia GI light grade pipe for protection of GI strip) to the extent of 7.5m as earthing lead and connecting to the eqpt viz transformer, LT kiosk etc. incl charcoal dust and salt packed all around the earth plate in the earth pit all as per electrical plate No 05 of SSR part-I including chamber made up of PCC 1:2:4 type B1 with MS angle iron frame CI cover with provision of locking arrangment and 20mm dia light grade GI. Pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangment, including excavation and earth work in any type of soil strata and testing including demolition of old earthing complete all as specified and directed. Note : GI strip of size 32 x 6mm alongwith protection pipe more than 7.5 mtr will be measured and paid for seperately.
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr depth for foundation , for shafts , wells , cesspits , manholes,pier holes and not exceeding 10 Sqmm on plan and not exceeding 1.5m depth and getting out complete all as specified and directed.
Returning , filling in including spreading , levelling , watering and well ramming in layers not exceeding 25 cm thick each layer complete all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directedat a level not exceeding 1.5 m above the starting point
Supply and spreading clean dry sand in trenches for cushioning all as specified for cable protection complete all as directed.
Supply and lay bricks of sub class 'B' type for protection of U/G cable in trenches all as specified and directed.
MCCB 400 Amps 4 pole 50 kA Ics=100% Icu with complete having fixed magnetic setting and adjustable thermal setting with extended terminal for easy connections with fixing arrangement and accessories, fixed in repairs, complete all as specified and directed at site. (Make : Legrand /siemen/C&S/ Hager/ABB/Schenieder).
MCCB 630 Amps 4 pole 36 kA Ics=100% Icu with complete having fixed magnetic setting and adjustable thermal setting with extended terminal for easy connections duly fixed arrangement and accessories, fixed in repairs, complete all as specified and directed at site. (Make : Legrand /siemen/C&S/ Hager/ABB/ Havells).
PARTAP ENGINEERING WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .