Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹76,700
Closing Date
12 Nov 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
Palghar and Dahanu Road - Electrical (Power) work in connection with extension of high level passenger platforms including raising of PF height at Palghar and Dahanu Road.
EL-81-950-WA-35~WR
EL-81-950-WA-35
Open
Works - General
12 Months
Mumbai, Maharashtra
₹0
₹76,700
7 Oct 2026
7 Oct 2026
29 Oct 2026
61 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 38,32,608 | ||
| — | 2.00 | — | — | ||
| Supply, fixing, testing & commissioning of MCB DB three phase with RCBO, in m.s. enclosure, out door type, I/C-FP RCBO of 63Amp - 1No and O/G: SP MCB of 10-32 Amp - 12Nos, as per specifications in Annexure I. | — | — | — | 16,864 | |
| — | 5.00 | — | — | ||
| Supply, fixing, testing & commissioning of 25A 4P RCBO with 30mA sensitivity, in m.s. enclosure, as per specifications in Annexure II. | — | — | — | 18,280 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing & commissioning of 100A 4P RCBO with 100mA sensitivity, in m.s. enclosure, as per specifications in Annexure III. | — | — | — | 66,480 | |
| — | 147.00 | — | — | ||
| Supply of energy efficient BEE 5 star rated BLDC ceiling fan 1200mm (48") sweep, with down rod, and standard accessories, fan & regulator shall be compatible to work with various makes & models, as per specifications in Annexure IV. (Minimum Warrantee - 2 years) | — | — | — | 3,41,334 | |
| — | 147.00 | — | — | ||
| Fabrication, supply and fixing of MS clamps with MS hook made with MS rod of 12mm dia., as per site requirement for installation of ceiling fans in covershed. The clamp shall be made from 30mm x 6mm MS flat in suitable shape, properly galvanized. The firm shall check the site for exact size & shape of clamps as per platform steel structure before fabrication and supply. | — | — | — | 28,077 | |
| — | 80.00 | — | — | ||
| Supply and fixing of ceiling fan down rod, heavy duty, white colour, rod size 2 feet length, 19 mm dia., 1.4 mm thickness, made of CRC Cold Rolled Coil or Cold Rolled Steel material. | — | — | — | 11,040 | |
| — | 6.00 | — | — | ||
| Supply, fixing, testing & commissioning of super energy efficient BLDC motor industrial exhaust fan of size 300mm (12") sweep and standard accessories, as per specifications in Annexure V. (Minimum Warrantee - 2 years) | — | — | — | 33,348 | |
| — | 10.00 | — | — | ||
| Supply, fixing, testing and commissioning of air circulator wall mounting type fans of size 30"/750mm sweep complete with necessary fixing arrangement, as per specifications in Annexure VI. | — | — | — | 1,04,560 | |
| — | 500.00 | — | — | ||
| Supply, fixing, testing & commissioning of indoor type LED luminaires 20W (maximum, including driver), 4 ft long, System efficacy greater than or equal to 110 lm/W, Lumen Output greater than or equal to 2000 lumens, Colour consistency CRI greater than or equal to 80, Driver Surge protection greater than or equal to 2.5KV. Luminaire should have Class B serviceability (i.e., the driver can be replaced or maintained at site). Luminaires complete with all accessories and other specifications as per Annexure VII. (Minimum Warrantee - 5 years) | — | — | — | 1,01,500 | |
| — | 16.00 | — | — | ||
| Supply, fixing, testing & commissioning of indoor type LED luminaires 15-20W (maximum 20W, including driver), 6"x 6" size, recess mounting type, System efficacy greater than or equal to 100 lm/W, Lumen Output greater than or equal to 1500 lumens, Colour consistency CRI greater than or equal to 80, Driver Surge protection greater than or equal to 2.5KV. Luminaire should have Class B serviceability (i.e., the driver can be replaced or maintained at site.Luminaires complete with all accessories and other specifications as per Annexure VII. | — | — | — | 24,592 | |
| — | 20.00 | — | — | ||
| Supply, fixing, testing & commissioning of indoor type LED luminaires 40W maximum, 2'x2' size, recess mounting type, System efficacy greater than or equal to 100 lm/W, Lumen Output greater than or equal to 3500 lumens, Colour consistency CRI greater than or equal to 80. Driver Surge protection greater than or equal to 2.5KV. Luminaire should have Class B serviceability (i.e., the driver can be replaced or maintained at site). Luminaires complete with all accessories and other specifications as per Annexure VII. (Minimum Warrantee - 5 years) | — | — | — | 29,520 | |
| — | 244.00 | — | — | ||
| Supply, fixing, testing & commissioning of outdoor type LED tube light luminaires 40W maximum, 4 ft long, whether proof having IP 65/66 protection, System efficacy greater than or equal to 110 lm/W, Lumen Output greater than or equal to 4000 lumens, Colour consistency CRI greater than or equal to 80. Driver Surge protection greater than or equal to 4KV. Luminaire should have Class B serviceability (i.e., the driver can be replaced or maintained at site). IK 08 protection for durability. Luminaires complete with all accessories and other specifications as per Annexure VII. (Minimum Warrantee - 5 years) | — | — | — | 9,22,076 | |
| — | 30.00 | — | — | ||
| Supply, fixing, testing & commissioning of LED street light lumaires 45W maximum, whether proof having IP 65/66 protection, System efficacy greater than or equal to 120 lm/W, Lumen Output greater than or equal to 5400 lumens, Colour consistency CRI greater than or equal to 70. Driver Surge protection greater than or equal to 4KV, The luminaire should have a potted driver, mounted inside the luminaire. Luminaire should have Class B serviceability (i.e., the driver can be replaced or maintained at site). Luminaries complete with all accessories and other specifications as per Annexure VII. (Minimum Warrantee - 5 years) | — | — | — | 1,34,460 | |
| — | 20.00 | — | — | ||
| Supply, fixing, testing & commissioning of outdoor type LED flood light luminaires 200W (maximum 220W), whether proof having IP 66 protection, System efficacy greater than or equal to 130 lm/W, Lumen Output greater than or equal to 26000 lumens, Colour consistency CRI greater than or equal to 70. Driver Surge protection greater than or equal to 4KV. The luminaire should have a potted driver, mounted inside the luminaire. Luminaire should have Class B serviceability (i.e., the driver can be replaced or maintained at site). Luminaires complete with all accessories and other specifications as per Annexure VII. (Minimum Warrantee - 5 years) | — | — | — | 2,66,280 | |
| — | 100.00 | — | — | ||
| Survey, design, manufacture, display of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 M thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. Details as per specifications in Annexure VIII. | — | — | — | 2,18,400 | |
| — | 100.00 | — | — | ||
| Erection and installation of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 M thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. Details as per corresponding specifications in Annexure VIII. | — | — | — | 21,700 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing and commissioning of thyristor SCR based hot standby switch with triple input (Master/ Slavel/ Slave-l) & Single output (P+N+G), of capacity 20 Amp, Single phase, as per specifications in Annexure IX. (24 Months Warranty). | — | — | — | 74,820 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing and commissioning of Auto Transfer Switch of 4 pole, 3 phase, 160A capacity in ms encloser, complete with all accessories as per specifications in Annexure X. | — | — | — | 85,226 | |
| — | 1000.00 | — | — | ||
| Supply of XLPE insulated, PVC sheathed, armoured 1.1 KV grade, multi-stranded aluminum conductor cable of size 25 sq.mm.x 4 core, as per specifications in Annexure XI. | — | — | — | 1,57,000 | |
| — | 500.00 | — | — | ||
| Supply of XLPE insulated, PVC sheathed, armoured 1.1 KV grade, multi-stranded aluminum conductor cable of size 50 sq.mm.x 4 core, as per specifications in Annexure XI. | — | — | — | 1,28,000 | |
| — | 500.00 | — | — | ||
| Excavation of the cable trench in normal soil under rail/ road and refilling back the excavated earth, restoring /repairing of flooring after lying of cable, as per specifications in Annexure XII. | — | — | — | 57,000 | |
| — | 429.00 | — | — | ||
| Excavation of the cable trench in hard soil under rail/ road/rocky soil / platforms (stone/RCC/Rock) and refilling back the excavated earth, recasting of flooring after lying of cable, as per specifications in Annexure XIII. | — | — | — | 3,62,076 | |
| — | 698.00 | — | — | ||
| Supply of material & saddling to the cables with GI saddles:1. The cable shall be fixed on walls/structures with G.I. saddle thickness of 1.2mm and G.I. base and suitable for the size of cables, minimum two saddles per meter shall be used while saddling the cable. 2. Galvanized base shall be provided below the cable and the base shall be fixed firmly first with M.S. fasteners of required size / standard quality counter sunk headed self-threading G.I. screw. Same shall be used for saddles also. | — | — | — | 33,504 | |
| — | 599.00 | — | — | ||
| Supply, fixing, testing & commissioning of colour coded 6 Nos x 25 sq.mm size hard drawn solid aluminium aerial wires with nominal PVC insulation of 1.2mm, including 8 SWG earthing wire, M.S. clamps / bracket with shackle insulators at end points for drawing the aerial cables & M.S clamps/ brackets with bobbin insulators at middle points for supporting the aerial wires, as per specifications in Annexure XIV. (Qty Unit - RM = (Running Meter) | — | — | — | 3,20,465 | |
| — | 250.00 | — | — | ||
| Supply of material and providing power supply connections to lights/ fans, with PVC insulated & sheathed, LSHF / ZHFR flexible multi strand copper cable of size 1.0 sq.mm. X 3 core, upto 3 meter length, in PVC conduit pipe for laying & protection including cable ties for fastening, connection of light/ fans, as per specifications in Annexure XV. | — | — | — | 60,750 | |
| — | 4.00 | — | — | ||
| Supply of material & installation of maintenance free earth electrode of length 3 meter, including earth enhancement material for earthing for each electrode & other accessories as per Drg. No. SDO/ RDSO/ E&B/001 and RDSO Spec No. RDSO/SPN/197 /2008, as per Annexure XVI. | — | — | — | 44,716 | |
| — | 104.00 | — | — | ||
| Supply, fixing, testing & commissioning of G.I. strip 25mm x 6mm for earthing, including cutting, bending, welding, excavation etc., as per specifications in Annexure XVII. | — | — | — | 11,024 | |
| — | 4.00 | — | — | ||
| Supply of 100mm dia. (V4) vertical type energy efficient multistage submersible pump set of capapcity suitable to deliver water at the rate of 90 to 60 LPM to the head of 66 to 86 Mtr., motor power rating of 3 HP/2.2 KW, 415V, 3ph, 50 Hz, etc., having water filled cooling, B class insulation, IP 68 protection, complete with all accessories, as per specifications in Annexure XVIII. | — | — | — | 1,12,904 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing & commissioning of fully automatic programmable digital control panel for pumpsets of capacity upto 7.5HP, 3- phase, 440V AC with micro-processor based technology, inbuilt Single Phase Protection, Water Level Guard, Dry Run Protection, Reverse Phase Protection, Overload, Under Voltage / Over Voltage Protection, inbuilt DOL starter, Digital Ammeter, LED screen etc in mountable sheet steel encloser IP 54 protection, with lock & key arrangement, complete with all accessories, as per Annexure XIX. | — | — | — | 40,812 | |
| — | 50.00 | — | — | ||
| Supply, laying, testing, fixing and commissioning of PVC insulated & sheathed, FRLS, multi-stranded submersible flat copper conductor cable of size 3 core x 2.5 sq.mm., as per specifications in Annexure XX. | — | — | — | 5,800 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-April-2022.pdf
ATTACHMENT
GCCCorrectionSlipNo1ofACS-14-07-2022.pdf
ATTACHMENT
GCCApril2022CorrectionslipNo_2RBDtd13122022.pdf
ATTACHMENT
IRSGCC-2022-AdvanceCorrectionSlipNo.3.pdf
ATTACHMENT
GCCApril2022ACSlip4.pdf
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo_5.pdf
ATTACHMENT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_111.pdf Advance Correction Slip No 11
ATTACHMENT
AnnexureVclarificationforonlinesubmissiondated14.05.2024.pdf
ATTACHMENT
BidSecurityFormat.pdf
ATTACHMENT
BankGuaranteeFormat.pdf
ATTACHMENT
E-PG16.6.26.pdf
ATTACHMENT
NORETIREDRAILWAYEMPLOYEEGCC2022-Annexure-III.pdf
ATTACHMENT
NoRelativeFormatEmployeeofWesternRailway-Annexure-II.pdf
ATTACHMENT
SignagesGuidelines.pdf
ATTACHMENT
EL-81-950-WA-352026-2027.pdf
ATTACHMENT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_111.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .