Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L2₹6.5 LQualified Make: Bluemount
Model: BLUEMOUNT B2 1 SHAYOG BUILDING 58 NEHARU PLACE NEW DELHI SOUTH WEST DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | Make: Bluemount
Model: BLUEMOUNT | L2 | Qualified | |
| 2 | L3₹6.5 LQualified Make: Eureka Forbes (Aqua Guard)
Model: Eureka Forbes Aquaguard Purechill RO 80 FSS 103 GREATER NOIDA W F NO 103 SHREE SAI RESIDENCE 2 SAI CITY SAI CITY VILLAGE TOWN SHAHBERI CITY GREATER NOIDA W | Make: Eureka Forbes (Aqua Guard)
Model: Eureka Forbes Aquaguard Purechill RO 80 FSS | L3 | Qualified | |
| 3 | Qualified Make: IONEXCHANGE
Model: Ion Exchange India Ltd 60/80/50 103 GREATER NOIDA W F NO 103 SHREE SAI RESIDENCE 2 SAI CITY SAI CITY VILLAGE TOWN SHAHBERI CITY GREATER NOIDA W | Make: IONEXCHANGE
Model: Ion Exchange India Ltd 60/80/50 | - | Qualified | |
| 4 | Disqualified Make: piyoindia
Model: 50 lph HOUSE NO 13 NR POLE NO 184 KH NO 8 4 2 KOTLA VIHAR PHASE II NANGLOI NORTH WEST DELHI WEST DELHI DELHI 110041 | WEST DELHI | DELHI | 110041 | Make: piyoindia
Model: 50 lph | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
5 May 2018, 6:00 pmClosed
Potable water purification system Average Turn Over of Last 3 Years 30 Lakh (s) Experience with Gov. Required 2 Year (s) Potable Water Purification System ( 6 ) Technical Specifications Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis based water purifier electricallyoperatedrev erseosmosisbasedwate rpurifier Ultraviolet (UV) LAMP No Yes
No Ultra Voilet (UV) Lamp power consumption 0 N/A STANDARDS Conformity to Indian Standrad for System IS 14724 (latest) for water purification system with Ultraviolet disinfection N/A Number of float valves/sensors 2 INPUT PARAMETERS Input Water TDS 1000 1000
2000
3000
4000
5000 OUTPUT PARAMETERS Recovery at 27 degree Centigrade 25-35 25-35
30-40
90-100
70- 80 Output Water of RO system Conforming to Indian Standard IS 10500(latest) N/A Output water capacity 50 50 1/4 (Litre/Hour): Arsenic and Floride removal capability true true Misc
warranty etc Thin-film composite membrane Yes yes High Pressure Pump Yes N/A Raw water/Chemical Raw water/Chemical Cleaning PUMP No Yes
No Pre Filter Vessels: Yes Yes
No Micron Filter Yes Yes
No Membrane Housing Yes Yes
No Auto cut Yes yes No of candles (Nos) 5 5 Installation Type Floor mounted floormounted Warranty period ( for free replacement of machine 2 2
3 Warranty Period (for scope including free of cost candle and activated carbon onsite replacement twice a year) 2 2
3 Antiscalant- where silica is up to 100 ppm/where Mica is up to 100 ppm Yes yes Chloride & Flouride removal facility Yes without pump yeswithoutpump Test Report Availability of type test report(Design Evalution Reports) as per IS:14724 and IS 10500 Yes N/A Test certificate No and date: T-1976 29/10/2015 N/A Name and Address of laboratory which conducted Test: Bhavan Research Cente
5th floor
Palanji Sadan
SFC Building
Andheri (W)
Mumbai-400058 N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 2/4 1 Chhinder Pal Singh 110001
CV Mess
Janpath
6 15 EMD Required No ePBG Required No
20766
GEM/2018/B/2951
Potable water purification system
15 days
Delhi; New Delhi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Potable water purification system Average Turn Over of Last 3 Years 30 Lakh (s) Experience with Gov. Required 2 Year (s) Potable Water Purification System ( 6 ) Technical Specifications Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis based water purifier electricallyoperatedrev erseosmosisbasedwate rpurifier Ultraviolet (UV) LAMP No Yes | - | - | - |
| No Ultra Voilet (UV) Lamp power consumption 0 N/A STANDARDS Conformity to Indian Standrad for System IS 14724 (latest) for water purification system with Ultraviolet disinfection N/A Number of float valves/sensors 2 INPUT PARAMETERS Input Water TDS 1000 1000 | - | - | - |
| 2000 | - | - | - |
| 3000 | - | - | - |
| 4000 | - | - | - |
| 5000 OUTPUT PARAMETERS Recovery at 27 degree Centigrade 25-35 25-35 | - | - | - |
| 30-40 | - | - | - |
| 90-100 | - | - | - |
| 70- 80 Output Water of RO system Conforming to Indian Standard IS 10500(latest) N/A Output water capacity 50 50 1/4 (Litre/Hour): Arsenic and Floride removal capability true true Misc | - | - | - |
| warranty etc Thin-film composite membrane Yes yes High Pressure Pump Yes N/A Raw water/Chemical Raw water/Chemical Cleaning PUMP No Yes | - | - | - |
| No Pre Filter Vessels: Yes Yes | - | - | - |
| No Micron Filter Yes Yes | - | - | - |
| No Membrane Housing Yes Yes | - | - | - |
| No Auto cut Yes yes No of candles (Nos) 5 5 Installation Type Floor mounted floormounted Warranty period ( for free replacement of machine 2 2 | - | - | - |
| 3 Warranty Period (for scope including free of cost candle and activated carbon onsite replacement twice a year) 2 2 | - | - | - |
| 3 Antiscalant- where silica is up to 100 ppm/where Mica is up to 100 ppm Yes yes Chloride & Flouride removal facility Yes without pump yeswithoutpump Test Report Availability of type test report(Design Evalution Reports) as per IS:14724 and IS 10500 Yes N/A Test certificate No and date: T-1976 29/10/2015 N/A Name and Address of laboratory which conducted Test: Bhavan Research Cente | - | - | - |
| 5th floor | - | - | - |
| Palanji Sadan | - | - | - |
| SFC Building | - | - | - |
| Andheri (W) | - | - | - |
| Mumbai-400058 N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 2/4 1 Chhinder Pal Singh 110001 | - | - | - |
| CV Mess | - | - | - |
| Janpath | - | - | - |
| 6 15 EMD Required No ePBG Required No | - | - | - |
Exempted
5 May 2018
21 Apr 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_20766.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .