| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Insufficient EMD Amount |
Tender Value
₹73.4 L
EMD Value
₹74,000
Closing Date
31 Aug 2020, 3:00 pmClosed
Project Director
DRDA, KKI
To Provide Functional Household Tap connection to Rural Households in 1 Village Panchayats in Sankarapuram Panchayat Union in Kallakurichi District for 2020-21 Package TNKKI/JJM 20-21/038
2020_RDTN_176932_1
TNKKI/JJM/038
Open Tender
Civil Works
Works
180 days
Kallakurichi District
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹74,000
Yes
4 Sept 2020
26 Aug 2020
31 Aug 2020
26 Aug 2020
31 Aug 2020
26 Aug 2020
Amount
Providing 237 FHTC ,Water Distibution Pipeline 2520 m, Pumping main line 350 m, Sembarambattu Panchayat
Distribution Line
Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001
Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
a. 63 mm OD PVC Pipe 4 KSC
Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
a. 63 mm OD PVC Pipe 4 KSC
Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
a. 63 mm OD PVC Pipe 4 KSC
Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
50mm PVC Bend page 12 ,sl.no-3
63mm X 50mm PVC Threaded coupler page 10 SOR
63mm x50 mm PVC Tee IS 7834/1987 page 10
63mm End cap page 12 sl.no 11
C.C. Roads
B.T Roads
Provision for gate value 50 mm - Pg No. 30, Clause 5.2
Providing for FHTC (8 meter length per FHTC)
Provision for 50 mm Water meter - TWAD SOR PAGE 81 for distribution
Electro Chloranation Disinfection - common salt as per TWAD SOR - page no -57 clause 21.2
Restoration of Cut Portion
Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method) .GRIII
Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete
Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.
Provision for Nameboard charges and Photographic charges
Pump Room
Earth work excavation & depositing on bank with an initial lead of 10 metre & initial lift of 2 metre in Hard shift clay, stiff block cotton, hard red earth shales, murrum, gravel, stoney earth, and earth mixed with small size boulders and hard gravelly soil (SS 20B) for foundation including shoring, strutting, baling out water providing danger light wherever necessary depositing the surplus earth on bank and other incedential charges etc., complete and as directed by TWAD board Officers
Levelling course with P.C.C 1:4:8 (one cement, four sand and eigth course aggregate) using 40 mm H.B.G stone including mixing concrete, laying, curing and compacting of concrete etc., complete and as directed by the TWAD Board Officers.
Earth filling in basement & sides of foundation with excavated earth including ramming and consolidation etc., complete
Supply and filling the foundation and basement with clear river sand in layers complying with standard specification including consolidation and watering etc. complete and as directed by TWAD Board Officers.
Brick work in CM 1:5 (one cement and five sand) using country bricks of size 8.75" X 4.25" X 2.00" including cost of all materials, labour charges, curing etc., complete and as directed by TWAD Board Officers.
For foundation and basement
For super structure
Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by TWAD Board Officers.
Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) excluding cost of steel fabrication,fixing in position and centring charges but including mixing,lifting and vibrating for SUNSHADE 75mm thick at wall face and 50mm thick at free end projecting 45cm from wall face moulded along with lintel etc. as directed by TWAD Board Officers.
Steel centering for soffits of RCC members including shuttering,strutting to the centring and providing supports etc.complete for the following members using MS Sheets of size 90cm x 60cm and BG 10 Gaugesstiffened with welded MS angles of size 25 x 25 x3mm laid over Silver Oak(country wood) joists of size 10 x 6.5 cm (spaced at about 90cm C/C) and supported by Casurania props of 10 cm to 13 cm dia. spaced at 75 cm C/C and as directed by TWAD Board Officers.The centring materials should be supplied and should be removed after the specified stripping time of the concrete as per IS 456/1978.
Plastering with C.M. 1:5(One part of cement and Five parts of sand) with 12mm thick over brickwork portion including labour charges for mixing finishing and curing etc., complete and as directed by TWAD Board Officers.
Special ceiling plastering for RCC Slab with C.M.1:3(One part of cement and Three parts of sand) 10mm thickover RCC surface including labour charges for mixing finishingand curing etc., complete as directed by TWAD Board Officers.
Flooring in C C 1:4:8 (one cement ,four sand and eight HBS) 10 cm thick using 40mm HBS metal and top finished with Cement mortar 1:3 (one cement and three sand) 12 mm thick including labour charges for mixing,finishing and curing etc. complete and as directed by TWAD Board Officers.
Supply and fixing of MS door (Single leaf) of sizes 1.00 x 2.00m in MS angle 50 x 50 x 4mm and MS flat 35 x 6mm with MS sheet of 18 gauge including ventilating arrangements using 20mm square MS rods with locing arrangements including two coats of approved enamel painting over one coat of primer
Supply, fabricating and fixing in position of RTS rods including cost of steel and binding wire etc., complete.
Supply and fixing of RCC box type jolly of size 0.6 x 0.45 m
Painting two coats with approved cement paint over one priming coat of white cement over cement plastered wall surface and ceiling including cleaning preparing the surface and curing etc., complete (using cement paint of colour as approved by the Departm
White washing two coats using fine screened shell lime for the new plastered surface for inner and outer side of the room including the cost of materials labour charges etc., complete and as directed by TWAD Board Officers.
Weathering Coarse over RCC roof including fixing one coarse of pressed tiles etc., complete.
Provision for writing TWAD Board emblem and scheme details on the side wall of the pump room
Provision of lock and key for pump room and OHT ladder
Levelling the site
Providing 237 FHTC ,Water Distibution Pipeline 2520 m, Pumping main line 350 m, Sembarambattu Panchayat
PUMP ROOM
Earth work excavation & depositing on bank with an initial lead of 10 metre & initial lift of 2 metre in Hard shift clay, stiff block cotton, hard red earth shales, murrum, gravel, stoney earth, and earth mixed with small size boulders and hard gravelly soil (SS 20B) for foundation including shoring, strutting, baling out water providing danger light wherever necessary depositing the surplus earth on bank and other incedential charges etc., complete and as directed by TWAD board Officers
Levelling course with P.C.C 1:4:8 (one cement, four sand and eigth course aggregate) using 40 mm H.B.G stone including mixing concrete, laying, curing and compacting of concrete etc., complete and as directed by the TWAD Board Officers.
Earth filling in basement & sides of foundation with excavated earth including ramming and consolidation etc., complete
Supply and filling the foundation and basement with clear river sand in layers complying with standard specification including consolidation and watering etc. complete and as directed by TWAD Board Officers.
Brick work in CM 1:5 (one cement and five sand) using country bricks of size 8.75" X 4.25" X 2.00" including cost of all materials, labour charges, curing etc., complete and as directed by TWAD Board Officers.
For foundation and basement
For super structure
Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) for the following members.The rate to excludethe cost of steel for reinforcement,centering,shuttering, strutting but includingcost of mixing of concrete,placing,vibrating with Mechanical Vibrator, finishing and curing etc. complete and as directed by TWAD Board Officers.
Reinforced cement concrete 1 : 1 1/2: 3(one cement,oneand half sand and three coarse aggregate)using 20mm size hard broken stone jelly(machine crushed) excluding cost of steel fabrication,fixing in position and centring charges but including mixing,lifting and vibrating for SUNSHADE 75mm thick at wall face and 50mm thick at free end projecting 45cm from wall face moulded along with lintel etc. as directed by TWAD Board Officers.
Steel centering for soffits of RCC members including shuttering,strutting to the centring and providing supports etc.complete for the following members using MS Sheets of size 90cm x 60cm and BG 10 Gaugesstiffened with welded MS angles of size 25 x 25 x3mm laid over Silver Oak(country wood) joists of size 10 x 6.5 cm (spaced at about 90cm C/C) and supported by Casurania props of 10 cm to 13 cm dia. spaced at 75 cm C/C and as directed by TWAD Board Officers.The centring materials should be supplied and should be removed after the specified stripping time of the concrete as per IS 456/1978.
Plastering with C.M. 1:5(One part of cement and Five parts of sand) with 12mm thick over brickwork portion including labour charges for mixing finishing and curing etc., complete and as directed by TWAD Board Officers.
Special ceiling plastering for RCC Slab with C.M.1:3(One part of cement and Three parts of sand) 10mm thickover RCC surface including labour charges for mixing finishingand curing etc., complete as directed by TWAD Board Officers.
Flooring in C C 1:4:8 (one cement ,four sand and eight HBS) 10 cm thick using 40mm HBS metal and top finished with Cement mortar 1:3 (one cement and three sand) 12 mm thick including labour charges for mixing,finishing and curing etc. complete and as directed by TWAD Board Officers.
Supply and fixing of MS door (Single leaf) of sizes 1.00 x 2.00m in MS angle 50 x 50 x 4mm and MS flat 35 x 6mm with MS sheet of 18 gauge including ventilating arrangements using 20mm square MS rods with locing arrangements including two coats of approved enamel painting over one coat of primer
Supply, fabricating and fixing in position of RTS rods including cost of steel and binding wire etc., complete.
Supply and fixing of RCC box type jolly of size 0.6 x 0.45 m
Painting two coats with approved cement paint over one priming coat of white cement over cement plastered wall surface and ceiling including cleaning preparing the surface and curing etc., complete (using cement paint of colour as approved by the Departm
White washing two coats using fine screened shell lime for the new plastered surface for inner and outer side of the room including the cost of materials labour charges etc., complete and as directed by TWAD Board Officers.
Weathering Coarse over RCC roof including fixing one coarse of pressed tiles etc., complete.
Provision for writing TWAD Board emblem and scheme details on the side wall of the pump room
Provision of lock and key for pump room and OHT ladder
Levelling the site
Providing New Borewell with Motar @ COLONY
Towards geophysical investigation charges
Drilling of 150 mm dia borewell in hard rock area using DTH rig
Towards supply and fixing of 165mm dia PVC Casing pipe
Supply and delivary of Wet type submersible 7.500HP (LPM 50x225) pumpset confirming to IS 8034/89 with ISI making along with 2.50sqmm suitable for installation in 150mm dia bore including transportation charges etc., complete
Supply and delivary of 10HP panel board suitable for above pumpset with all accessaries as per IE rule with IS Specification
Labour charges for erection of submersible pump set including fixing and jointing the submersible cable with clamps to the required depth, valves and errection panel board control room twin earthing as per I.E Rules including cost of civil works
Supply and delivery of 4.00 sqmm pvc insulated and pvc sheathed 3core flat type copper cable confirming to ISI Mark
Supply and delivery of GI medium class pipes and specials as per relevant IS as listed below.
40mm GI Pipe (3m) length Medium SOR TWAD page 25
40mm GI Coupling Heavy page 40
40mm GI Bend Heavy page 40
50mm GI Flangeset Heavy page 40
40mm MS Clampset Heavy page 40
50mm GM Non Return Valve page 30
50 x 40mm GI reducer heavy page 26
63mX50mm PVC T.Coupler page 10
40mm Ball Valve/ GM Gate Valve page 30
Lighting the pumpromm including internal wiring with switch circute fuses etc. with the following light fittings with ISI marking.
40W box type tube light - 1 No. SD -88
100W bulb with angle holder
100W bulk head fittings SD-84
5 AMPS 3 pin socket with switch SD -133
5 Amps switches for light(Flush type)
Providing lighting wiring using MS conduit pipes and specials with 2 runs 1.5 sqmm PVC copper wire and 1 run 12 swg GI wire for earthing for light, fans and 5A plug points etc., SDD -1
Obtaining power supply including cost of following materials and by engaging B licence holder.EB fee for application form and deposit amount will be borne by the Board
(i) Aerial fuse board of size 15 x 10 x 6cm with 32 A aerial fuse carrier(3 Nos.)
(iii)Wall mounting type MS cubical EB meter box with fuse carrier (3 Nos) of 32 A capacity at EB supply point.This box is also to accommodate TNEB energy meter with proper ventilation as approved by TNEB. SD-125
(ii) Supply and laying of 7/20 size PVC insulator copper conductor cable from Aerial fuse to EB supply point etc., complete as per I.E Rules. SD-64
25mm dia GI pipe for service point
25mm dia GI Elbow
No.8 GI wire for earth(Twin earthing)
Stay wire 7/20
20mm GI pipe for twin earthing and cable encasing
4way nutral link
TW banel board (41 x 31 x 6cm)
Provision for Nameboard charges and Photographic charges
Distribution Line
Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001
Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
a. 63mm OD PVC Pipe 6 KSC
Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
a. 63mm OD PVC Pipe 6 KSC
Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
a. 63mm OD PVC Pipe 6 KSC
Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
50mm PVC Bend page 12 ,sl.no-3
63mm X 50mm PVC Threaded coupler page 10 SOR
63mm x50 mm PVC Tee IS 7834/1987 page 10
63mm End cap page 12 sl.no 11
C.C. Roads
B.T Roads
Provision for gate value 50 mm - Pg No. 30, Clause 5.2
Providing for FHTC (8 meter length per FHTC)
Provision for 50 mm Water meter - TWAD SOR PAGE 81 for distribution
Electro Chloranation Disinfection - common salt as per TWAD SOR - page no -57 clause 21.2
Water Meter for Pumping Main Lines
Restoration of Cut Portion
Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method) .GRIII
Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete
Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.
OHT - SERVICE RESERVOIR - 60000 lit
Earth work excavation & depositing on bank with an initial lead of 10 metre & initial lift of 2 metre in Hard shift clay, stiff block cotton, hard red earth shales, murrum, gravel, stoney earth, and earth mixed with small size boulders and hard gravelly soil (SS 20B) for foundation including shoring, strutting, baling out water providing danger light wherever necessary depositing the surplus earth on bank and other incedential charges etc., complete and as directed by TWAD board Officers
First depth of 2m From 0 to 2 m below GL
Second depth of 1m
Sand filling for foundation with clear river sand including cost of sand, watering ,ramming and consolidation etc complete as directed by TWAD Board officers
Plain Cement Concrete 1:4:8 (one cement, four sand and eight hard granite broken stone of 40mm size ISS gauge) for foundation and footing including mixing, placing, ramming ,finishing curing etc. complete in accordance with standard specification and as directed by the TWAD Board Officers.
Reinforced Cement Concrete Mix M30 grade using 10mm & 20mm Hard blue granite Broken stone (machine crushed) excluding the cost of RTS rods for reinforcement and centering, strutting, shuttering but including cost of all materials mixing, laying, Vibrating the concrete with mechanical vibrators, ramming, consolidating, finishing and curing etc., Complete and as directed by the TWAD Board Officers.
For items 1.5m to 4.5m below GL
For items 0 to 1.50m below GL
For items 0m to 4.5m above GL &1.00 m Above G.L
For items 4.50m to 7.32m above GL
For items 7.32m to 10.98m above GL
For items 10.98m to 14.64m above GL
For items above 14.64m & up to 18.30m from GL
Supply and erection of steel centering, shuttering for soffits and sides including necessary supports and strutting for all RCC works using MS sheets of suitable size of BG10 stiffened with MS angle of size 25 X 25 X 3 mm for boarding laid over I type MS Truss of size 25 X 25 X 3mm about 90cm c/c and supported by 40mm GI pipes (Medium) spaced at 75cm c/c etc complete and as directed by the TWAD Board Officers.
PLANE SURFACES
ABOVE G.L. to 3.30m
CURVED SURFACE
Square column
3.31m to 4.30m ht
Painting two coats with approved cement paint over one priming coat of white cement over cement plastered wall surface and ceiling including cleaning preparing the surface and curing etc., complete (using cement paint of colour as approved by the Departmental officer) and as directed by the TWAD Board officers.
Supplying, cutting, bending, tying, fabricating and placing in position of steel rods for all RCC works including cost of steel and binding wire etc.( The steel should conform to the relevant ISspecification and supplied with test certificate Fe. 415 grade as per IS specification No.1786/1985 and as amended from time to time) delivery at site of work including loading, freight, unloading, stacking, transit insurance charges, taxes etc. complete.and as directed by the TWAD Board officers.
Supply delivery and fixing of staircase with M30 grade concrete for landings, MS ladder of 0.45m wide using 50x50x5mm MS angles for sides and steps at 0.30m c/c, with GI pipe handrails using 32mm GI pipes for railings and verical support at 0.45m C/c, MS flats (Size 40mm x 5mm ) for horizontal ties at 0.3m c/c and at bottom with Anchor fastener bolts of size 12mm x 75mm including cost of materials labour for fabrication of handrails fixing, painting etc., complete.
Providing and fixing of RCC inner access ladder in RCC 1:11/2 :3 (one cement,one and half sand and three aggregate) using 20mm HBG stone for OHT including cost of reinforcement, placing grill in position, centring,shuttering charges, mixing concrete,curing etc. to required height and clear width of 45 cm consisting of 2 nos. of vertical post of 10 cm x 15 cm and step slab of 25mm x 25mm etc.complete and as directed by TWAD Board Officers.
Providing 110mm PVC vent cowl arrangements mosquito proof nylon net and as directed by TWAD Board officers
Supply and fixing of cut stone of size 0.30m x 0.30m x 0.15m in CM 1;3(one cement and three sand) below inlet pipe for Service Reservoir as directed by TWAD Board Officers.
Providing manhole cover of size 0.60 x 0.60M in RCC 1:1.5:3 with suitable reinforcement and 50x50x6mm MS angle fixed along edges and as directed by TWAD Board officers
Painting TWAD Board emblem on the SR with enamel paint as per Board's specification and as directed by TWAD Board officers
Pipe connection arrangements for inlet,outlet,scour and overflow etc. including cost of pipes,specials,valve,labour charges for lifting, aligning, cutting, threading ,fixing and painting of GI pipes with two coats of approved quality enamal paint etc. complete as detailed below.
65mm GI pipes for over flow & rain water harvesting pipe
65mm GI pipes for scour pipe
50MM GI Pipe for scour pipe
65mm GI pipe for delivery pipe
90mmX80MM PVC Threaded coupler
63mmX50MM PVC Threaded coupler
65mm GI coupler
65mm GI union
65mm GI Elbow
50mm GI union
50mm GI Elbow
65mm GI TEE
65x50mm GI reducer
75mmx63mm PVC reducer
65mm GM gate valve
50mm GM gate valve
63 mm PVC 4Ksc Pipe
Refilling the foundation with excavated earth including consolidation as directed by the TWAD Board officers
Labour charges for GI pipe connection to the OHT, for inlet, outlet, overflow and scour arrangements including cutting and threading, earth work excavation & refilling.
Providing Hand rails over the Roof slab by using 32 mm GI Pipe with 40mm x 6mm MS Flat and fixied with 12mm dia Fastner Bolt 75mm long and as directed by TWAD Bd officers
Providing Hand rails over the Standing Platform by using 32 mm GI Pipe with 40mm x 6mm MS Flat and fixied with 12mm dia Fastner Bolt 75mm long and as directed by TWAD Bd officers
Provision for levelling the site and SBC test
Pumping Main Line
Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001
Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
a. 90 mm OD PVC Pipe KSC
Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
a. 90 mm OD PVC Pipe KSC
Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
a. 90 mm OD PVC Pipe KSC
Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
90mm PVC Bend page 12 ,sl.no-3
B.T Roads
Providing 80mm SAV along the pumping main alignment
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
A.SIVA
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .