Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.2 L+₹5.3 L (48.3%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹16.4 L+₹5.5 L (50.7%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹17.0 L+₹6.1 L (55.8%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹20.5 L+₹9.6 L (88.0%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L5 | Rejected-Finance Being L5 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
27 May 2020, 6:00 pmClosed
CWE (AF) Palam Delhi Cantt-10
CWE (AF) Palam Delhi Cantt-10
CA NO CWE/PM/SP-01/2020-21 REPAIR, RENEWAL, MAINTENANCE, SERVICING, CALIBRATION OF HT EQUIPMENTS, CABLES, EARTHING AND ALLIED E/M WORKS AT VARIOUS SUB STATIONS AND AREA UNDER WAC (U) SUBROTO PARK, DELHI CANTT-10
2020_MES_337636_1
CA NO CWE/PM/SP-01/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Subroto Park Delhi Cantt
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) Subroto Park
₹50,000
Yes
23 Jul 2020
6 Apr 2020
29 May 2020
6 Apr 2020
27 May 2020
20 Apr 2020
Amount
Disconnecting worn out HT connections any size from VCB, cutting worn out leads ( near lugs ), re fixing new Aluminium lugs , cleaning the bus bar chamber with 2-26 CRC solution , insulating with HT tape , connecting the cables with bus bar and testing for smooth functioning complete all as specified and as directed by Engineer-in-Charge.
Repair/servicing of 400/630/800 A 11 KV mechanism/ calibration of HT VCB with highly skilled mechanic specialist in electric HT breakers line, by taking out trolley, decarborizing of all parts using CRC-2-26 spray, checking of all fixed and moving parts, tightening of all nuts & bolts, dressing, cleaning of contacts by using emery paper for fine/smooth contact, tightening of all connections, checking of alignment for easy moving of breaker, checking of ON/OFF operation with setting of buffer gap adjustment, inspecting the wiring of IDMT relays contact travel contact alignments, roller gap, hard or light setting of breaker greasing of all moving mechanism complete all as specified and as directed by Engineer-in-Charge. Note ; Carlibration will be carried out by auth contractor / Tech and test certificate will be kept on record.
S & F in replacement of following spares of VCB complete including required necessary spares :-
Geared motor 230V AC/DC. Make- ITE Pvt Ltd/ABB/Crompton Greaves
Trip Coil 24/110V DC. Make- ITE Pvt Ltd/ABB/Crompton Greaves
Closed Coil 24/110V DC. Make- ITE Pvt Ltd/ABB/Crompton Greaves
Close Latch. Make- ITE Pvt Ltd/ABB/Crompton Greaves
Trip Latch. Make- ITE Pvt Ltd/ABB/Crompton Greaves
Operation counter. Make- ITE Pvt Ltd/ABB/Crompton Greaves
Auxilary Switch 6 NO/6NC. Make- ITE Pvt Ltd/ABB/Crompton Greaves
Micro Switch. Make- ITE Pvt Ltd/ABB/Crompton Greaves
Interrupter Housing. Make- ITE Pvt Ltd/ABB/Crompton Greaves
Finger Contact 800A. Make- ITE Pvt Ltd/ABB/Crompton Greaves
Drive Insulator. Make- ITE Pvt Ltd/ABB/Crompton Greaves
Vaccume Interrupter - 800A, 13.1 KA. Make- ITE Pvt Ltd/ABB/Crompton Greaves
Vaccume Interrupter - 1250A, 18.4 KA. Make- ITE Pvt Ltd/ABB/Crompton Greaves
Vaccume Interrupter - 2000A, 26.4 KA. Make- ITE Pvt Ltd/ABB/Crompton Greaves
Metal Part 250mm (for finger contact Upper side). Make- ITE Pvt Ltd/ABB/Crompton Greaves
Metal Part 135mm (for finger contact Lower side). Make- ITE Pvt Ltd/ABB/Crompton Greaves
Compact Mechanism. Make- ITE Pvt Ltd/ABB/Crompton Greaves
Spout Bushing. Make- ITE Pvt Ltd/ABB/Crompton Greaves
C.T/ Dual core dual ratio, Cl.1, 5P 10. Make- ITE Pvt Ltd/ABB/Crompton Greaves
P.T. 11 KV/110 V-100 VA. Make- ITE Pvt Ltd/ABB/Crompton Greaves
P.T. Holder (Male-Female). Make- ITE Pvt Ltd/ABB/Crompton Greaves
M&L for IDMT relay testing/calibration of IDMT relay (Set of two) over current and one earth fault for healthy tripping of over current and earth fault, adjust tripping time flag setting, ratio setting, instantaneous time setting etc as per installed capacity of transformer to be saved on maximum Short circuit current with considering of percentage impedance of transformers with artificial current injunction on primary side with current injunction machine and setting of relays to make as per the CT ratio complete all as specified and as directed by Engineer-in-Charge. Make-L&T/Legrand/Schneider
S & F in replacement of Digital type single pole non directonal relay for one earth fault & two over current, type CDG-31,3D Horz 2 No S/R 3 element O/C & EF comprising over current operator with DC current connecting setting as per ratio including complete wiring complete all as specified and as directed by Engineer-in-Charge. Make-L&T/Legrand/Schneider
S & F in replacement Indicator lamp with and including holder & cover to show all the three phase i.e RYB to be mounted on 11 KV HT switch gear complete all as specified and directed by Engineer-in-Charge.
S & F in replacement Push button for trip and hold of 11 KV 400 A OCB/VCB, complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of Bakelite kitkat with 10 A HRC fuse type NS complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of Primary copper wound type HT resin cast CTs, air cooled , dual current 3.0 VA, class 1 5P10 of ratio 400/1A, for 3 section protection and suitable burden for metering including making all, connection for relay meter indicator etc. and including connecting testing conforming to IS-2705-1992; complete all as specified and directed by Engineer-in-Charge.
All as per item No 11 here-in-before but burden of ratio 2.5 VA, class 1.0 of ratio 300/1A
S & F in replacement of Primary copper wound type HT resin cast CTs, air cooled , dual current 15 VA burden of ratio 50/25/5 A, class 5P1O accuracy S T C 18.4 KA for 3 section protection and suitable burden for metering including making all, connection for relay meter indicator etc. and including connecting testing conforming to IS-2705-1992; complete all as specified and directed by Engineer-in-Charge. Make- Crompton Greeves /L&T/Legrand
All as per item No 13 here-in-before but burden of ratio 100/50/05A. Make- Crompton Greeves /L&T/Legrand
All as per item No 13 here-in-before but burden of ratio 200/100/5A. Make- Crompton Greeves /L&T/Legrand
S & F in replacement of dry type air cooled potential transformer of 11 KV single phase indoor resin cast CT of ratio 11 KV /rt3/110V/rt3/110V/rt3 class 0.5-3, Bus bar 50 VA-50 VA, insulation level 28/75 KV voltage factor 1.2 Cont and 1.9 for 30 Sec conforming to IS-3156 complete all as specified and directed by Engineer-in-Charge.
M&L Maintenance free battery 12 Volt, 40/45 AH complete all as specified and directed by Engineer-in-Charge
S & F in replacement of power pack unit input 110 / 230 Volt AC and out put 24/110 V DC for maintenance free batteries charging for smooth tripping complete all as specified and directed by Engineer-in-Charge
Dismantling & taking down old, deteriorated aluminium tube terminals and S & F Aluminium tube terminals for HV cable (heavy duty thimble) of size 95 Sqmm including suitable size nuts, bolts & washers complete all as specified and directed by Engineer-in-Charge
All as per item No 19 above but 120 sqmm
All as per item No 19 above but 150 sqmm
All as per item No 19 above but 185 sqmm
All as per item No 19 above but 300 sqmm
S & F in replacement of HT danger notice plate of 25cm x 20 cm x 1.6mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of required complete all as specified and directed by Engineer-in-Charge. Note : (a) Letters and Nos shall be in local language, Hindi and English) (b) For 1 to 24 shall be of existing make/ model and of reputed brand or as approved by Engineer-in Charge/GE.
Excavating in trenches in hard / dense soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of cable etc not exc 10 Sqmm on plan and not exc 1.5 m in depth and getting out complete all as specified and directed by Engineer-in-Charge
Returning , filling in , including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated surplus soil to a distance upto 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Supply and laying un-reinforced precast concrete cable cover class HV type-I flat size 300 mmx180mmx40mm complete all as specified and directed by Engineer-in-Charge.
Material and labour for sand cushioning by using fine sand ( Jamuna dry and clean sand ) in two layers , first layer of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable complete all as specified and directed by Engineer-in-Charge. Note : 180 mm thickness only will be considered for the purpose of payment.
Supply & Laying GI pipe light grade 80mm bore for cable protection with all fittings for passing the under ground HT cable under road crossing along poles walls and floors complete all as specified and directed by Engineer-in-Charge.
M&L for cutting of metallic road/ hard standing / hard rock/ wall up to a size not exceeding 20 cm width and not exceeding 90 cm depth for laying of protection pipe for cable including making good the disturbed road/ hard standing by providing PCC (1:2:4) type B1, 40mm grade crushed stone aggregate and block top with black bituminous upto existing surface including suitable size of GI pipe (if necessary) complete all as specified and as specified and as directed by Engineer-in-Charge. Note:1. If damage / broken the inter locking tiles while removing the contractor shall replace the broken tiles with new one. 2. The Quoted rate is included for all material can paid/measured separately. 3. All the removable inter locking tiles/re fixable material shall kept carefully at a safe place for refixing with quoted rate.
Dismantling disconnecting and taking out existing unserviceable defective HT cable any size any type from trenches / duct / poles including taking out old bricks complete all as specified and directed by Engineer-in-Charge
Supply, Laying, Testing and Commissioning for XLPE insulated , screened PVC bedded , galvanized strip , armoured , electric power cable , heavy duty , with aluminium conductor 11 KV (E) grade , cross sectional area 150 Sqmm x 3 core confirming to IS-7098 ( Part II ) ( amended upto date ) including supplying , jointing and testing , complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning for XLPE insulated , screened PVC bedded , galvanized strip , armoured , electric power cable , heavy duty , with aluminium conductor 11 KV (E) grade , cross sectional area 185 Sqmm x 3 core confirming to IS-7098 ( Part II ) ( amended upto date ) including supplying , jointing and testing , complete all as specified and as directed.
Supply, Laying, Testing and Commissioning for XLPE insulated , screened PVC bedded , galvanized strip , armoured , electric power cable , heavy duty , with aluminium conductor 11 KV (E) grade , cross sectional area 300 Sqmm x 3 core confirming to IS-7098 ( Part II ) ( amended upto date ) including supplying , jointing and testing , complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of cable jointing kit for 11 KV (E) grade cable for indoor termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of cable jointing kit for 11 KV (E) grade cable for indoor termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm complete all as specified and directed by Engineer-in-Charge.
M &L in replacement of cable jointing kit for 11 KV (E) grade cable for outdoor termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size upto 95 sqmm complete all as specified and directed by Engineer-in-Charge.
M & L in replacement of cable jointing kit for 11 KV (E) grade cable for outdoor termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed by Engineer-in-Charge.
M&L for in replacement of cable jointing kit for 11 KV (E) grade cable outdoor for straight through cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed by Engineer-in-Charge.
M&L for defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. Excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 Sqmm 3 core. The fault located equipment will be brought to site within 02 hours of instruction received from Engineer-in-Charge complete all as specified and directed by Engineer-in-Charge.
Notes for Srl. Item No.41 : (i) The contractor shall bring the fault locating equipment at site with in 02 hours of instructions received from Engineer -in- charge and he shall ensure that the fault is rectified with in 24 hours of receipt of intimation from Engineer-in-charge failing which recovery of Rs. 500.00 per hour shall be recovered from the contractors dues w.e.f the time immed -iately after the expiry of 24 hours duration.(ii) For the purpose of payment one unit of “each job” shall comprise of detection of faults in a particular stretch of cable which are identified in that particular stretch , irrespective of number of defects / faults in that particular stretch which are detected during fault detection and the contractors unit rate quoted shall be deemed to include for the same and all such defects / faults which are detected in that particular stretch shall be considered as one unit. (iii.) Joints , jointing materials and cable required shall be measured and paid for separately.
Disconnecting the electric supply to the transformer,opening the top cover of 11 KV/0.433KV step down transformer upto 500 KVA capacity by removing the inspection cover/top cover, decanning of the transformer oil upto required level for replacement of LT/HT bush from the shell and replacement for burnt out/ unserviceable LT/HT bush, studs and gasket of buchholes to avoid leakge of oil, refilling of oil into the transformer after required repair works complete all as directed by Engineer-in-Charge. Note : (a) HT /LT metal studs, HT/LT bushes and gaskets will be measured and paid seperately under respective items here-in after. (b) Replacement of unserviceable bolts, nuts and washers are deemed to be included in the quoted rate.
Disconnecting the electric supply to the transformer,opening the top cover of 11 KV/0.433KV step down transformer of capacity 630 to 1000 KVA by removing the inspection cover/top cover, decanning of the transformer oil upto required level for replacement of LT/HT bush from the shell and replacement for burnt out/ unserviceable LT/HT bush, studs and gasket of buchholes to avoid leakge of oil, refilling of oil into the transformer after required repair works complete all as directed by Engineer-in-Charge. Note : (a). HT /LT metal studs, HT/LT bushes and gaskets will be measured and paid seperately under respective items here-in after. (b). Replacement of unserviceable bolts, nuts and washers are deemed to be included in the quoted rate.
S&F HT porcelain bush suitable for any make of transformers upto 500 KVA capacity complete all as specified and directed by Engineer-in-Charge.
S&F HT porcelain bush suitable for any make of transformers of capacity 630 to 1000 KVA complete all as specified and directed by Engineer-in-Charge.
S&F LT rod/studs with nuts and washers of brass all as per size and shape of original complete all as specified and directed by Engineer-in-Charge.
(a) upto 500 KVA
(b) above 630 KVA to 1250KVA
S&F set of top cover gasket for transformers of capacity upto 500KVA complete all as specified and directed by Engineer-in-Charge.
S&F set of top cover gasket for transformers of capacity 630 KVA to 1000 KVA complete all as specified and directed by Engineer-in-Charge.
M&L for painting of transformer upto 500 KVA including connected LT bus duct in the transformer room with synthetic enamel grey paint by using spray gun machine after removing all dust and rust. Date will be written by black synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for painting of transformers of capacity 630 KVA to 1000 KVA including connected LT bus duct in the transformer room with synthetic enamel grey paint by using spray gun machine after removing all dust and rust. Date will be written by black synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
S&F LT porcelain bush suitable for transformers in repair of any make and of capacity 500 KVA to 1000 KVA complete all as specified and directed by Engineer-in-Charge
S&F as in repairs, oil temperature gauge for 750 /500 KVA transformer complete all as specified and directed by Engineer-in-Charge Make- Savita/Transol/Neptune
Supply and filling of fresh transformer oil in transformers having diaelectric strength more than 45 KV in 3 mm gap including testing complete all as specified and directed by Engineer-in-Charge
Purification, filtration and Dehydration of transformer oil of transformer installed at various indoor/outdoor sub station by ultra high vaavvun filtration machine with stream line filtration plant at a temp 60 to 70 deg. celsius and achieving minimum dieectric withstand strength of 60 KV for 1 minute in 2.5 mm gap setting (for used oil) complete all as specified and directed by Engineer-in-Charge.
S& F digital type Ammeter of size 96X96 mm on HT panel as that of existing range model to suit to existing CT ratio 100/1A including taking out unserviceable one connectiong testing and commissioning all as specified and directed by Engineer-in-Charge.Make L&T and equivalent. Make-L&T/Legrand/Schneider
S&F digital type Ammeter of size 96X96 mm on HT panel as that of existing range model to suit to existing CT ratio 150/1A including taking out unserviceable one connectiong testing and commissioning complete all as specified and directed by Engineer-in-Charge. Make-L&T/Legrand/Schneider
Supply only suitable for 11KV HV Hand gloves complete with ISI marked complete all as specified and directed by Engineer-in-Charge
Supply, laying and pasting on floor suitable for HV 11KV synthetic insulating rubber mat of size 2m x1m x 19mm class A complete with ISI marked complete all as specified and directed by Engineer-in-Charge..
M&L for disconnecting HT & LT side cables of follwing indoor/outdoor transformer of capacity 63 KVA to 1000 KVA and earth strip from body and neutral of transformer mounted on two pole/four pole structure/staging/sub stn and taking down the transformer manually/using mechanical means and lifting loading and transportation to MES store yard/site to civil workshop for repair and opening of covers,draining out existing transformer oil,lifting of core,cleaning of oil tank,using chemicals,cleaning of core after removing HT/LT winding,re-assembling of new HT/LT windings with core varnishing heating and bringing back the same after repairs to the same point all as specified and directed by Engineer-in-Charge. Note-(i) Rewidning of HT/LT coil any type/material,dehydration of transformer oil reassembling after repair etc.will be measured and paid seperately under relevant item of the schedule. (ii) Spare parts shall be measured and paid seperately as supply only and cost of fixing and connection of spare parts shall be deemed to included in the quoted rate of the above items.
M&L for taking out old unserviceable HT/LT coil removing insulation complete by brushing coil,cleaning the the inner body complete making free from dist and dirt,all impurities, applying paper insulation(IS specified) of transformer complete of capacity 63 to 1000 KVA complete all as specified and directed by Engineer-in-Charge.
M&L for re-winding of HT coils with super enemelled best quality copper wire of existing guage with superior quality insulation material for transformer of capacity 63 to 1000 KVA complete all as specified and directed by Engineer-in-Charge.
M&L for re-winding of LT coils with super enemelled best quality copper wire of existing guage with superior quality insulation material for transformer of capacity 63 to 400 KVA complete all as specified and directed by Engineer-in-Charge.
M&L for painting of old painted surfaces with synthetic enemel paint to LT steel tubbular/swan neck pole 9 mtr long including clamps,brackets,chanel,cross arms,bracing support,pipe of support for cable and swan neck etc including zebra painting at bottom up to 1.5 mtr above from the PCC coping and writing pole No with white paint complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:4:8 type B2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for providing cement concrete type B1, 1:2:4 (Using 20 mm graded stone aggregate as in foundation, roof, kerb or mud stops, rounded or chamfered on edges ccomplete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron earht strip 25x4mm thick fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and water pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engineer-in-Charge. Note: 1. RCC pit cover shall be precast of RCC 1:2:4, type B-1 (20 mm graded stone aggregate) 80 mm thick reinforced XPM not less than 4 Kg/Sqm in lieu of Cl cover. 2. GI earth wire upto 7.5 m is deemed to be included in the quoted rate and beyond 7.5 m will be measured and paid separately under relevant items.
Commercial Traders
M/S MG GROUP
Shiv Enterprises
Ridhi engineers and builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .