Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹33.3 L+₹8.7 L (35.4%)Rejected-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L2 | Rejected-AOC Other than L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
1 Apr 2023, 6:00 pmClosed
Mathews M Shepherd, GE
Mathura Cantt
REPAIR/REPLACEMENT OF LT PANELS, UNSERVICEABLE STARTERS WITH ALLIED ACCESSORIES ETC AT WATER SUPPLY INSTALLATION UNDER GE (W) MATHURA
2023_MES_585271_1
8300/1135/E8
Open Tender
Civil Works
Item Rate
180 days
GE (W) MATHURA
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (West) Mathura
₹80,000
Yes
16 May 2023
10 Mar 2023
3 Apr 2023
10 Mar 2023
1 Apr 2023
20 Mar 2023
Amount
Supply, installation, testing and commissioning of LT panel, indoor type, floor mounted not less than of 1500 mm x 1650 mm x 600 mm IP -54 degree of protection suitable for 3 phase, 4 Wire system , 415 Volts, 50 Hz ,CPRI approved factory made having independent compartment for bus bar incoming feeder and each out going feeders, dust and vermin proof, outer shell fabricated of 2 mm thick CRCA sheet & made out angle iron frame of 40 mm x 40 mm x 5 mm (for external) with seven tank treatment process for powder coating with thickness not less than 60 micron provided with suitable gasket to make it dust/vermin proof & general construction confirming to IS 8063/93, pedestal flame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregate, thimble and cable entry boxes with cable glands including disconnecting and dismantling old LT panel of any size complete in all respect and comprising of the following: - Inner Shell:- Inner shell made out of 1.6 mm thick CRCA sheet duly compartmentalised for each control gear, front lockable/openable by keys from both sides having chromium plated 19 mm dia fancy lock (02 Nos in each neutral flow of air 'U' type completely vermin proof & to accomodate incoming/outgoing MCCBs and TPN aluminium bus bar of rating not less than 1.5 times of rated capacity of incoming MCCB. The colour coded heat shrinkable sleave for bus bar and shall be mounted on non hydroscopic, non combustible, track resistant, high strength FRP/SMC/DMC material at an
interval not more than 250 mm throughout complete all as specified and as directed.Incoming:- (a) MCCB - 400 Amp, 415 Volt, 4 pole, 50 KA with adjustable thermal & magnetic protection/setting, Ics = 75 % Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In in accordance with IS/IEC 60068-2-6 standard - 01 Each Outgoing:-(a) Automatic Transfer switch from one source to other with adjustable time delay of current rating 400 Amp, 4 pole, 415 Volt AC, utilization category AC 31 A, indicating status of the source to which load is connected, with provision of LCD display, phase separator for safety from phase to phase shorting & flashover having inbuilt protection for mains/DG against under/over voltage, under/over frequency and phase failure - 01 Each (b) MCCB - 160 Amp, 415 Volt, 4 pole, 36 KA with adjustable thermal & magnetic protection/setting, Ics=100% Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In.- 05 Each
Supply, installation, testing and commissioning of LT panel, indoor type, floor mounted not less than of 1500 mm x 1650 mm x 450 mm IP -54 degree of protection suitable for 3 phase, 4 Wire system , 415 Volts, 50 Hz ,CPRI approved factory made having independent compartment for bus bar incoming feeder and each out going feeders, dust and vermin proof, outer shell fabricated of 2 mm thick CRCA sheet & made out angle iron frame of 40 mm x 40 mm x 5 mm (for external) with seven tank treatment process for powder coating with thickness not less than 60 micron provided with suitable gasket to make it dust/vermin proof & general construction confirming to IS 8063/93, pedestal flame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregate, thimble and cable entry boxes with cable glands including disconnecting and dismantling old LT panel of any size complete in all respect and comprising of the following: Inner Shell:- Inner shell made out of 1.6 mm thick CRCA sheet duly compartmentalised for each control gear, front lockable/openable by keys from both sides having chromium plated 19 mm dia fancy lock (02 Nos in each neutral flow of air 'U' type completely vermin proof & to accomodate incoming/outgoing MCCBs and TPN aluminium bus bar of rating not less than 1.5 times of rated capacity of incoming MCCB. The colour coded heat shrinkable sleave for bus bar and shall be
mounted on non hydroscopic, non combustible,track resistant, high strength FRP/SMC/DMC material at an interval not more than 250 mm throughout complete all as specified and as directed. - Incoming:- (a) MCCB - 200 Amp, 415 Volt, 4 pole, 36 KA with adjustable thermal & magnetic protection/setting, Ics = 100 % Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In in accordance with IS/IEC 60068-2-6 standard. - 01 Each Outgoing:- (b) MCCB - 100 Amp, 415 Volt, 4 pole, 25 KA with adjustable thermal & fixed magnetic protection/setting, Ics = 100 % Icu, thermal adjustable - 0.8 to 1 In, in accordance with IS/IEC 60068-2-6 standard.- 02 Each
Supply & fixing in replacement of worn out volmeter with Analog Voltmeter ( moving coil- rectifier type), 0 to 600 Volt AC, square flush size - 96 mm x 96, Accuracy class 1.5 conforming to IS 1248 part 2/2003 including making connections complete in all respect as directed.
Supply & fixing in replacement of worn out ammeter with CT operated( moving coil- rectifier type) analog type ammeter, square flush size - 96mm x 96 mm, Accuracy class 1.5 conforming to IS 1248 part 2/2003 including making connections complete in all respect as directed.
Supply & fixing in replacement of worn out CT with resin casted CT of current ratio 800/5 Amp, burden -15 VA, accuracy class 1.0, conforming to IS 2705/ IEC 60044-1 including making connections to metering instrument in existing busbar of LT panel complete in all respect as directed.
Supply & fixing in replacement of worn out CT with resin casted CT of current ratio 400/5 Amp, burden -15 VA, accuracy class 1.0, conforming to IS 2705/ IEC 60044-1 including making connections to metering instrument in existing busbar of LT panel complete in all respect as directed.
Supply & fixing in replacement of worn out CT with resin casted CT of current ratio 200/5 Amp, burden -10 VA, accuracy class 1.0 including, conforming to IS 2705/ IEC 60044-1 including making connections to metering instrument in existing busbar of LT panel complete in all respect as directed.
Supply & fixing in replacement of worn out CT with resin casted CT of current ratio 100/5 Amp, burden -10 VA, accuracy class 1.0, conforming to IS 2705/ IEC 60044-1 including making connections to metering instrument in existing busbar of LT panel complete in all respect as directed.
Supply & fixing in replacement of worn out indicator lamp with LED Indicator lamp with Surge & Low Voltage Glow Protection, 22.5 mm dia suitable for 240 Volt AC in red, yellow, green colour including making connections complete in all respect as specified and directed.
Supply & fixing in replacement of worn out indicator lamp with LED Indicator lamp with Surge & Low Voltage Glow Protection, 22.5 mm dia suitable for 240 Volt AC in blue colour including making connections complete in all respect as specified and directed.
Supply & fixing in replacement of worn out PVC flexible conduit with double wall corrugated ( DWC) HDPE flexible conduit of outer dia 63 mm in accordance with IS 16205 (Part 24) : 2018 /IS 14930 (Part 2) : 2001, having characteristics of high hardness, heavy pressure resistance, wear resistance and no deformation, high mechanical strength, slightly flexibility and excellent electrical insulation and mechanical electrical protection complete all as specified and directed.
Supply & fixing in replacement of worn out PVC flexible conduit with Flame Retardant Poly Propylene (FRPP) corrugated flexible conduit of outer dia 20 mm, temperature resistant from - 5 degree C to 90 degree C, having characteristics of high hardness, heavy pressure resistance, wear resistance and no deformation, high mechanical strength, slightly flexibility and excellent electrical insulation and mechanical electrical protection complete all as specified and directed.
Supply & fixing in replacement of worn out PVC rigid conduit with uPVC trunking/casing capping of size 75 mm x 50 mm including fittings conforming to IS 14927/2001, fixed on wall/ceiling surface to cover the cable/wire complete in all respect and as directed
Supply & fixing in replacement of worn out PVC rigid conduit with uPVC trunking/casing capping of size 100 mm x 50 mm including fittings conforming to IS 14927/2001, fixed on wall/ceiling surface to cover the cable/wire complete in all respect and as directed
Supply & fixing in replacement of worn out PVC rigid conduit with uPVC trunking/casing capping of size 25 mm x 16 mm including fittings conforming to IS 14927/2001, fixed on wall/ceiling surface to cover the cable/wire complete in all respect and as directed
Supply & fixing in replacement of worn out cable with single core HRFR PVC insulated unsheathed copper conductor flexible cable/wire of 70.0 Sqmm, 1100 Volt grade conforming to IS 694/2010 drawn through PVC rigid/flexible non metallic conduit including making connections to three phase starter & induction motor by providing copper lugs complete in all respect as specified and directed.
Supply & fixing in replacement of worn out cable with single core HRFR PVC insulated unsheathed copper conductor flexible cable/wire of 35.0 Sqmm, 1100 Volt grade conforming to IS 694/2010 drawn through PVC rigid/flexible non metallic conduit including making connections to three phase starter & induction motor by providing copper lugs complete in all respect as specified and directed.
Supply & fixing in replacement of worn out cable with single core HRFR PVC insulated unsheathed copper conductor flexible cable/wire of 16.0 Sqmm, 1100 Volt grade conforming to IS 694/2010 drawn through PVC rigid/flexible non metallic conduit including making connections to three phase distribution panel/box by providing copper lugs complete in all respect as specified and directed.
M&L for Sub main wiring with 2 runs of 6 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 25mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 6 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 6 Sqmm cable, one run of 6 Sqmm earth conductor and one run of PVC conduit of 25mm dia shall be measured and paid as one unit length.
M&L for Sub main wiring with 2 runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduit ISI marked 25mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 4 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth conductor and one run of PVC conduit of 25mm dia shall be measured and paid as one unit length.
Supply & fixing in replacement of worn out cable with single core Flame Retardant Low Smoke & Halogen FR-LSH PVC Insulated unsheathed copper conductor flexible cable/wire of 2.5 Sqmm, 1100 Volt grade conforming to IS 694/2010 drawn through flexible non metallic conduit including making connections by providing copper lugs complete in all respect as specified and directed.
M&L for Cutting & Chasing required on concrete block/path tile /floor etc not exceeding 20 cm girth to conceal the cable/PVC conduit and making good to disturbed surface with cement mortar 1:3 including facing / finishing where as required to match with existing surfaces complete all as specified and directed.
Cutting holes into or through brick walls built in cement mortar and making good in cement mortar (1:3) or cement concrete (1:2:4) type B-1 as required superficial area exc 400 sq cm but n. exc 0.10 Sqm and depth n. exc 10cm complete all as specified and directed.
Supply & fixing in replacement of worn out starter with fully automatic star delta ( FASD) starter/controller suitable for 75 HP, 3 phase, 415 volt AC, AC-3 duty induction motor in sheet steel enclosure with IP 54 protection to changeover from star winding to delta winding with the help of electronc timer, having ON/OFF operation and overload protection with additional features like Auto ON (with 30 sec ON Delay), indications of supply ON/OFF and pump ON/OFF, reading of real time voltage & current of pump with unique dual analog meter, single phasing protection relay (SPPR), relay range 66 to 110 Amp, wide band coil operation from 65% to 110% of rated coil voltage - 380/415 Volt, phase-reversal protection, phase-unbalance protection, variable time-delay adjustment inside controller complete in all respect and conforming to IS/IEC 60947-4-1 standards complete all as specified and directed.
Supply & fixing in replacement of worn out starter with fully automatic star delta ( FASD) starter/controller with in built WLC suitable for 20 HP, 3 phase, 415 volt AC, AC-3 duty induction motor in sheet steel enclosure with IP 54 protection to changeover from star winding to delta winding with the help of electronc timer, having ON/OFF operation and overload protection with additional features like Auto ON (with 30 sec ON Delay), indications of supply ON/OFF and pump ON/OFF, reading of real time voltage & current of pump with unique dual analog meter, single phasing protection relay (SPPR), relay range 20 to 33 Amp, wide band coil operation from 65% to 110% of rated coil voltage - 380/415 Volt, phase-reversal protection, phase-unbalance protection, variable time-delay adjustment inside controller complete in all respect and conforming to IS/IEC 60947-4-1 standards complete all as specified and directed.
Supply & fixing in replacement of worn out starter with DOL starter/controller suitable for 2.0 HP, single phase, 230 volt AC, induction motor in sheet steel enclosure with IP 54 protection, thermal overload protection with wide band coil of voltage range from 140 to 270 volt, relay range 9 to 14 Amp complete in all respect and conforming to IS/IEC 60947-4-1 standards and as directed.
Supply & fixing in replacement of conventional FTL( 4 x 40 Watt) light fitting with energy saving, environment friendly & robust Highbay LED luminaire of 200 Watt wide beam in aluminum alloy pressure die casted housing for better heat dissipation and aesthetic appeal, finished with epoxy powder coated, Ingress protection of IK -07, operating voltage range: 140 -270 VAC, Colour Temp -5700 Kelvin having high efficiency long life LEDs with lumen efficacy of >130 Lm/W with view angle 90º/120º to ensure better uniformity of light distribution, High quality PC lens with wide beam angles for uniform distribution as per photometric data refer to LM 79 report, built-In potted IP67 electronic LED driver with APFC, lower THD, Open Circuit Protection, over voltage protection, surge voltage protection upto10 kV with integral SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC 60598-1, 61547, 61347-2-13, EN 55015, suspended by means of heavy duty nickel plated, forged eye-bolt provided with the fixture complete in all respect as specified and as directed.
Supply & fixing in replacement of worn out DB with vertical SPN double door distribution board, 8 way in sheet metal enclosure made of CRCA sheet of minimum thickness 1.0 mm, 200 Amps rated fully shielded copper bus bar, detachable din bar with end stopper, neutral & earth link with top and bottom detachable plates, Ingress protection of IP- 42, conforming to IEC 61439-3, IS 13032 & IS 8623 complete in all respect as specified and directed.
Supply & fixing in replacement of worn out DB with TPN MCB distribution board vertical loadline, 4 way in sheet metal enclosure made of CRCA sheet of minimum thickness 1.2 mm, suitable for provision of four pole MCCB as incomer with 250 Amps rated copper bus bar and neutral link, double door, IP protection - 42 conforming to IEC 61439-3, IS 13032 & IS 8623 complete in all respect as specified and directed.
Supply & fixing in replacement of worn out MCB with MCB single pole, 240 volts, 6 Amp to 32 Amp, breaking capacity 10 KA (type 'C' curve) conforming to IS/IEC 60898-1 : 2002 including making connection, testing and commissioning in DB complete all as specified and directed.
Supply & fixing in replacement of worn out MCB with MCB double pole, 240 volts, 32 Amp, breaking capacity 10 KA (type 'C' curve) conforming to IS/IEC 60898-1 : 2002 including making connection, testing and commissioning in DB complete all as specified and directed.
Supply & fixing in replacement worn out MCB with 50 Amp MCB, double pole, breaking capacity 10 KA, 'C' curve, ISI marked, conforming to IS/IEC 60898-1 : 2002 including making connection, testing and commissioning in DB complete all as specified and directed.
Supply & fixing in replacement of worn out AC box with socket residual current device with MCB protected, 25 Amp, C series in plastic enclosure including 16 Amp, 3 pin Plug top with Indicator (heavy duty) conforming to IS 13032 & IS 8623 complete in all respect and as directed.
Supply & fixing in replacement of MCCB - 63 Amp, 415 Volt, 4 pole, 16 KA with adjustable thermal & fixed magnetic protection, Ics = 100% Icu, thermal adjustable - 0.8 to 1 In, in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in DB complete all as specified and directed.
Supply & fixing in replacement of MCCB - 100 Amp, 415 Volt, 4 pole, 16 KA with adjustable thermal & fixed magnetic protection, Ics = 100% Icu, thermal adjustable - 0.8 to 1 In, in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in DB complete all as specified and directed.
Supply & fixing in replacement of MCCB - 125 Amp, 415 Volt, 4 pole, 25 KA with adjustable thermal & fixed magnetic protection, Ics = 100% Icu, thermal adjustable - 0.8 to 1 In, in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in DB complete all as specified and directed.
Supply & fixing in replacement of MCCB - 160 Amp, 415 Volt, 4 pole, 16 KA with adjustable thermal & magnetic setting/protection, Ics = 100% Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in DB/LT panel complete all as specified and directed.
Supply & fixing in replacement of MCCB - 200 Amp, 415 Volt, 4 pole, 36 KA with adjustable thermal & magnetic setting/protection, Ics = 100% Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in DB complete all as specified and directed.
Supply & fixing in replacement of MCCB - 250 Amp, 415 Volt, 4 pole, 36 KA with adjustable thermal & magnetic setting/protection, Ics = 100% Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in LT Panel complete all as specified and directed.
Supply & fixing in replacement of MCCB - 320 Amp, 415 Volt, 4 pole, 36 KA with adjustable thermal magnetic protection, Ics = 100% Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in LT panel complete all as specified and directed.
Supply & fixing in replacement of MCCB - 400 Amp, 415 Volt, 4 pole, 36 KA with adjustable thermal magnetic protection, Ics = 100% Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in LT panel complete all as specified and directed.
Supply & fixing in replacement of MCCB - 630 Amp, 415 Volt, 4 pole, 50 KA with adjustable thermal magnetic protection, Ics = 75% Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in LT panel complete all as specified and directed.
Supply & fixing in replacement of MCCB - 800 Amp, 415 Volt, 4 pole, 65 KA with adjustable thermal & fixed magnetic protection, Ics = 100% Icu, thermal adjustable - 0.8 to 1 In, in accordance with IEC 60068-2-6 standard including making connection, testing and commissioning in LT panel complete all as specified and directed
Supply & fixing in replacement worn out MCB with 63 Amp MCB, TPN, breaking capacity 10 KA, 'C' curve, ISI marked , conforming to IS/IEC 60898-1 : 2002 including making connection, testing and commissioning in DB complete all as specified and directed.
Supply & fixing in replacement worn out MCB with 100 Amp MCB, four pole, breaking capacity 10 KA, 'C' curve, ISI marked, conforming to IS/IEC 60898-1 : 2002 including making connection, testing and commissioning in DB complete all as specified and directed.
Supply & fixing in replacement worn out MCB with 125 Amp MCB, four pole, breaking capacity 10 KA, 'C' curve, ISI marked, conforming to IS/IEC 60898-1 : 2002 including making connection, testing and commissioning in DB complete all as specified and directed.
Supply & fixing in replacement of worn out change over switch with Automatic Transfer Switch from one source to other with adjustable time delay of current rating 400 Amp, 4 pole, 415 Volt AC, utilization category AC 33 A, indicating status of the source to which load is connected, with provision of LCD display, phase separator for safety from phase to phase shorting & flashover having inbuilt protection for mains/DG against under/over voltage, under/over frequency and phase failure in SS Enlosure complete as conforming to IS / IEC 60947-6-1 including connecting all cable connections, testing and commissioning by providing alluminium lugs as required size complete in all respect and as directed..
Supply & fixing in replacement of worn out change over switch with Automatic Transfer Switch from one source to other with adjustable time delay of current rating 125 Amp, 4 pole, 415 Volt AC, utilization category AC 31 A, indicating status of the source to which load is connected, with provision of LCD display, phase separator for safety from phase to phase shorting & flashover having inbuilt protection for mains/DG against under/over voltage, under/over frequency and phase failure in SS Enlosure complete as conforming to IS / IEC 60947-6-1 including connecting all cable connections, testing and commissioning by providing alluminium lugs as required size complete in all respect and as directed.
Labour only for laying LT cable, XPLE insulated, PVC Sheathed, 1100 Volt grade of size 50 sqmm x 3.5 core to 185 sqmm x 3.5 Sqmm at required site including taking down complete in all respect and as directed.. Note : LT cable of size 50 to 185 Sqmm x 3.5 Core will be issued by department free for laying/fixing.
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized strip 32 mm x 6 mm as earthing lead protected by 40 mm dia light grade GI pipe bore for protection of GI earth strip and GI pipe 20mm dia light grade for watering, supply and filling charcoal dust, common salt all around the electrode in alternate layers of 150 mm including all accessories like GI nut, bolts, reducer, nipple, wire meshed / screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with a cast iron hinged cover resting over the cast iron frame painted with bitumastic paint which shall be embedded in the block masonry including excavation and earth work, refilling as shown in electrical plate No. 3 of SSR Part-I and connected to LT Panel /DG Sets etc including testing of earth resistance as required including taking out existing earth platecomplete all as specified and directed.
shyam construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .