Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L1 | Accepted-AOC L1 quoted rates are overall reasonable,hence Accepted | |
| 2 | L2₹28.0 L+₹1.6 L (6.05%)Rejected-AOC FLAT NO 703 7TH FLOOR PARVATI ENCLAVE PLOT NO 180 SECTOR 2 TOLOJA PANCHANANDTAL TALOJA MAJKUR DISTT RAIGAD MAHARASHTRA 410208 | RAIGAD | MAHARASHTRA | 410208 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹33.3 L+₹6.9 L (26.3%)Rejected-AOC 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹42.2 L+₹15.9 L (60.2%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
22 Jul 2020, 6:00 pmClosed
GE(NW)BHANDUP
GE(NW)BHANDUP,MUMBAI
ADDN/ ALTN AND SPECIAL REPAIR TO NS-17, NS-122 AND PROVN OF TOILET NEAR SH -31 , WATERPROOFING TREATMENT OF ROOF AT CERTAIN BUILDINGS AT MO(MB) GHATKOPAR
2020_MES_356252_1
8837/B
Open Tender
Civil Works
Item Rate
184 days
GHATKOPAR
For unenlisted contractors scan copy of doc meeting enlistment criteria of MES in cl D cat a(i)
9 documents required · 9 mandatory
₹500
GE(NW)BHANDUP
₹91,000
17 Oct 2020
26 Jun 2020
27 Jul 2020
26 Jun 2020
22 Jul 2020
10 Jul 2020
27 Jun 2020 - 4 Jul 2020
Amount
Dismantling of roof terracing cement / brick concrete (un-reinforced) and existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material out of MD land complete all as specified.
M&L for PCC 1:2:4 Type B0 using 12.5 mm graded aggregate with 2% by weight of cement or as per manufacturer's instructions water proofing as in levelling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamferred on edges and formwork etc all as specified and directed.
M&L for preparation of surfaces and applying oil bound bitumin primer over the roof surfaces @ 0.40 lit per sqm confirming to IS code , manufactrured by the same agency as that of Mineral top APP with density of 0.87-0.89 KG/ lit at 25 degree C prepared dry roof surfaces for filling the voids and to receive water proofing membrane of weight not less than 3.6 Kg per sqm grit finish on roof slab and without grit finish on parapet wall and mumty portion reinforced with non wooven polyester matt all as per manufacturer's instructions and zonal specification and as directed by Engr-in-Charge.
M&L for solar reflective bituminous aluminium paint @ 0.10 Kg per Sqm over membrane surfaces as in roof treatment complete all as specified
M&L for 20mm thick screed bed in CM 1:4 mixed with 80ml per kg of cement or as per manufacturer's instructions of polymeric liquid water proofing additive over Non woven Geo textile layer to ensure no puncture of APP membrane over polymeric membrane surface etc as specified and directed by Engineer-in-Charge. (Note : Supply of polymeric based liqluid water proofing compound will be measured and paid separately)
M&L for laying 300 mm x 300 mm x 20 mm thick PCC tiles (Hydraulically pressed) with grey cement, set, jointed, cut and polished. The joints shall be grouted and immediately after gouting, the joints shall be pointed flush in in CM 1:3 mixed with 150ml per kg of cement of polymeric based lilquid water proofing additive by weight of cement or as per manufacturers instructions etc all as specified and directed. (Note : Supply of polymeric based liqluid water proofing compound will be measured and paid separately)
Supply only polymer based lilquid water proofing compound.
M&L for making the grooves to 'V' section in existing parapet walls/columns over RCC roofs, cleaning out and tucking the polymeric membrane in to the grooves and sealing solidly with a hot mixture of bitumen and clean dry sand in the ratio of 1:1 by weight etc complete all as specified and directed.
M&L for complete removal of existing treatment on walls including washing down, rubbing down and applying two coats of Dr fixit rain coat over one coat of Dr fixit primer all as spd and directed by Engr-in-Charge
M&L for rendering 15mm in two coats (10mm+5mm) on fair faces of brick work or concrete surfaces in CM (1:4) with integral water proofing compoundISI Marked @ 2% by the weight of cement and finishing the surface even and fair complete all as specified and directed (Note:- Water proofing compound shall be measured and paid seperatly.)
Supply only integral water proofing compound.
M&L for Preparation of New Plastered surfaces of wall and applying two coats of Dr fixit rain coat over( of Shade/colour as directed by E-in-C) one coat of Dr fixit prime seal primer all as per manufacturer instruction including necessary scaffoldings etc complete all as specified and directed by Engr- in charge
Taking down cement or cement lime plaster of any description on brick or stone wall and ceiling surface including raking out joints, hacking for key, scrubbing down with water etc and disposing off the rubbish outside MD land complete all as specified and directed.
M & L for rendering 5 mm thick in CM 1:3 on concrete surfaces as in ceiling and finishing the surfaces even and smooth complete all as specified and directed.
M&L for filling cracks with polymer based chemical (Dr fixit cracks shrink free or equivalent) for cracks not exc 10 mm in width as per manufacturer instruction on wall surfaces on concrete or masonary including scaffolding etc complete all as specified and directed.
M & L for providing & fixing of FRP chajja of approved make & colour, surfaces should be finished as like Mangalore clay tile design (the FRP chajjas to be moulded in gel coat finish, the thickness to be 2.00 mm to 2.5 mm and back patti to be additionally reinforced with core matt, all resins and pigment to be fully weatherable and UV established, core ,malt to be used with GSM for extra thickness, necessary FRP covered metal, fixing the chajjas in position that required level with necessary scaffolding and working platform including providing 8 mm dia MS bolt 125 mm long spacing not more than 45 cm suitable anchor fasters in the holes drilled in the wall RCC members to hold the chajjas in position etc, filling the gaps with poly sulphide seal and complte all as specified and directed.
Dismantling asbestos cement (corrugated semicorrugated, etc) sheets in roof covering including ridge, north light curves etc complete all as specified and directed.
S&F for Pre- Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping ,drilling of screws/suitable length GI 'J' or 'L' hooks in roof complete all as specified and directed.
S&F for Pre- Painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/rigdes, fixed with self tapping ,drilling of screws/suitable length GI 'J' or 'L' hooks in roof, including necessary scaffolding etc complete all as specified and directed.
S&F for roof trusses (framed) trussed, Purlins, crane gantries, rails and fastenings and heavy brackets framing(Beam, Angle, Channel or flat section,plain plates) including distance pieces, cleats ,welding and braceing etc,Fe-410W(Gde-E-250)quality -B, including necessary scaffolding etc complete all as specified and directed.
S & F Mild steel Angles, bars, flats ,plane angle cleats for securing to vallay gutter supports, wall ties,securing purlins J or L hook clamps with nut bolts,washers and similar small articles confirming to Fe 290 or Gde-E165 complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size & pattern) including all fitting, head shocs, bends etc complete all as specified and directed.
S&F 160mm bore PVC rain water pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps 8mm dia with two nuts wall nails etc complete all as specifed and directed.
M&L for rendering 12 mm thick in CM 1:6 on brick walls, RCC pillars, beams, purlins etc and finishing the surface even and smooth complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying Two coat of oil bound distemper including application of wall care putty for smooth finish.etc with roller over one coat of alkali resistant primer including chalk whiting complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and thereafter applying with roller Two coat of oil bound distemper including application of wall care putty for smooth finish.etc complete all as specified and directed.
M&L for preparation of new plastered surfaces on walls, chajjas,filling of hair line cracks with white cement and applying two coats of 100% anti fungal weather resistant acrylic paint over a coat of acrylic primer in approved shade and as per manufacturer's instructions including necessary scaffolding complete all as specified and as directed.
M&L for complete removal of existing treatment on walls including washing down, rubbing down and applying antifungal treatement as required and applying two coats of 100% acrylic emulsion paint over a coat of primer as specified and directed by Engr-in-Charge
M&L for preparation of new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide etc complete all as specified and directed.
Dismantling of ceiling board (fibre, pulp,insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets etc complete all as specified and directed.
M & L for false ceiling of galvanised iron frame work of angle section of 15 x 15 x 28 gauge for support and main U section of 40 x 20 x 26 Gauge and supporting U clip of 32 x 18 x 26 Gauge and gypsum board of 12.5 mm thick in panels fixed to GI frame work including cutting, bolting, welding etc of GI frame work and providing POP finish to the ceiling and applying two coat of OBD complete all as to the satisfaction of Engr - in - Charge
M&L for preparation of old wooden surfaces of any description, not other wise described, over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old decorated steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frames) not exceeding 1.5 Sqm each complete as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on surfaces of walls including finishing the surfaces even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 5 to 10mm thick in cement mortar (1:3) on the surfaces of the ceiling, finishing the surfaces even and smooth without using extra cement, complete all as specified and directed.
M&L preparing newly plastered surfaces and applying 3 coats of white wash on ceiling complete.
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed
M&L for preparation of new plastered suface of wall and applying two coat of oil emulsion distemper over one coat of alkali resistent primer complete all as specified and as directed by Engineer-in-Charge.
M & L for APP modified roof treatment over existing accessible RCC roof slab etc to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed:- (a) Cleaning existing surface properly. (b) Providing 10 mm thick cement plaster in CM (1:3) using water proofing compound @ 3% by weight of cement (c) Applying oil bound bitumen primer @ 0.40 litre/ Sqm manufacture by the same agency as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on the prepared dry surface. (d) Laying 4mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyester fibre weight not less than 160gm/Sqm using butane torch by torch application with 10cm side lap and 15cm end lap. Laying of membrane shall be got done through an authorised applicator of manufacture of membrane. Physical properties of membrane shall be as under:- (i) Membrane weight not less than 3.60 Kg/Sqm. (ii) Non woven polyester weight not less than 160gm/sqm. (iii) Softening point of membrane not less than 150 degree Celsius.(iv) Joint tensile strength-longitudinal not less than 650/sqcm and trasverse not less than 450/sqcm at 230 degree Celsius.(v) Tear strength-longitudinal not less than 300 N & transverse not less than 250 N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 kg/sqcm. (e) APP membrane shall be laid using butane torch by Torch application with minimum 10 cm side overlap and 15 cm end lap. The laying of membrane shall be got done through on authorised applicator of manufacturer of membrane.
M & L for 20 to 25mm machine cut, kota stone slab, in single piece, in window cill, riser of steps, skirting, dado and pillar and similar work, laid over and including backing coat, in CM 1:4, 10 mm thick, jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with beeswax polish complete all as specified and as directed
S&F standard aluminum section powder coded in partition / frame and door shutter, sliding windows / ventilators and places otherwise not specified cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass or wire cloth or Bakelite sheet and all necessary fittings, hinges, screws, plugs, locking arrangements for windows, Nylon ball bearing etc completed all as specified and directed (Aluminum section shall be of make Jindal / Hindalco / Indalco). Note :- Weight of Aluminum sections for frames and shutters shall be only considered for payment. Cost of other consumables required for the item shall be deemed to be included in the quoted rate. However glass panes / Bakelite sheet / wire cloth / mortice lock / locking stay / floor spring / floor door stopper only will be measured and paid separately under respective items as supply only. Fixing by element of these items shall be deemed to be included in quoted rate.
S&F aluminum anodised grill DG- 202 ( 10 mm x 5.2mm ) of Deco grill or equivalent fixed with 'F' section size not less than 20.60 x 15.20 x 1.5mm thick of approved make all as specified and directed. Note : (i) Make shall be of M/s Decogrille of M/s Associated Groups or equivalent as approved by the GE. (ii) Minimum thickness of anodizing shall be 15 microns.
Supply only 4.80 mm thick glass ordinary quality in plain not exc 0.50 Sqm each pane including rubber beading or gasket for aluminium section complete all as specified. complete all as specified.
Supply only stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm , fixed in aluminium windows complete all as specified and directed.
Chipping, removing carefully loose/damaged concrete including plastering (total thickness exceeding 40mm but not exceeding 60mm ) from surfaces of RCC members, in any location by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land complete all as specified and directed. Note : 1) Hard concrete shall not be removed by force 2) Item No.13.00 and 60.00 will not be applicable for the locations/areas where item No.52.00 is applicable.
M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hour between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for carry out application of ‘Bi-polar migratory corrosion inhibitor' [Make : M/s. Krishna Conchem (EPCO KP-100) / BASF (MasterProtect®8000Cl)] on RCC surfaces, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed . Note :- Mode of measurement: superficial area of concrete will be measured.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar / concrete to ensure bond between old concrete & new concrete/ new mortar by brush application, complete all as specified and directed.
M&L for providing Polymer Bonding Agent of Make M/s. Krishna Conchem (MONOBOND) OR Fosroc (NITOBOND-SBR) OR equivalent brand of Dr. Fixit,as approved by the GE followed by flexible polymer based putty ( 1cement: 1.2 finesand :20% polymer by weight of cement : water as required ) on cracks after cutting the cracks to a 'V' shaped groove upto 10 mm wide and 10 mm deep in structural RCC members , finished with spatula etc. complete all as specified and directed.
M&L for casting & repairing of excessively damaged distressedRCC members (exceeding 60mm in thikness) with prebatched, prepacked, single component ready to use microconcrete from Fosroc (Renderoc RG) or equivalent of Dr. Fixit as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant works, complete all as specified and directed. (Note : Reinforcement only shall be measured and paid separately).
M&L for building up the profile of structural members using polymer modified mortar from M/s. Krishna Conchem (Molith PMM) OR Polymer mortar HB of Dr Fixit, while the bonding agent is still tacking upto 20mm thickness, including levelling, profiling etc, complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar from M/s Krishna Conchem (Molith PMM) OR Polymer mortar HB of Dr. Fixit, exceeding 20mm thick and not exceeding 40mm thick in two layers, each of equal thickness including levelling, profilling etc, complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, splays between floors and beam etc, to achieve fair finish on flat surfaces of the concrete, complete all as specified and directed
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exceeding 200 mm thick to achieve fair finish on flat concrete surfaces, complete all as specified and directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions to achieve fair finish on flat concrete surfaces, complete all as specified and directed.
S&F 40mm bore U- PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. with all fittings in repairs completed all as specifiec and directed.
S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 25 mm bore complete all as specified and directed.
M&Lfor Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in Hard/ Dense soil complete all as specified and directed.
M&L for Plain Cement Concrete type D2 1:4:8 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete.
M&L for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar(Type 1:3:6 with 20 mm graded aggregate), complete all as specified and directed
M&L for rendering 10 mm thick in CM 1:6 on brick walls, RCC pillars, beams, purlins etc and finishing the surface even and smooth complete all as specified and directed.
M&L for Hardcore of broken stone or boulders of gauge n. exc 63 mm , deposited, spread and levelled in layers n. exc 15 cm thick , watered and rammed to a true surfacecomplete all as specified and directed..
M&L 100 mm thick cement concrete type B-2, 1:2:4 (40mm graded stone aggregate) as in as in flooring/path/Pavement complete all as spd and directed.
M&L for Mild steel TMT bars 10 mm dia., and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for Mild steel TMT bars 8 mm to 10 mm dia, cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for Reinforced Cement Concrete 1:2:4(Nominal mix) using 20m m graded stone aggregate as in beams, cantilever, lintels over 1.5m span complete all as specified and directed. (Note: Reinforcement and form work shall be measured and paid separately).
M&L for Reinforced Cement Concrete 1:2:4(Nominal mix) using 20m m graded stone aggregate as in slab supported on walls, beams and columns in floors complete all as specified and directed. (Note: Reinforcement and form work shall be measured and paid separately).
S&F Solid PVC door frame (Chowkhat) of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube etc complete all as specified and directed.
S&F for Factory made solid PVC Moulded door shutter, 28 to 30 mm thick, with 2,4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing with wood free EPS complete all as specified and as directed.
Supply only 4mm thick sheet figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 Sqm in each pane etc complete all as specified and directed
S&F 100 mm stainless steel butt hinges,complete all as specified and directed
S&F 150mm length aluminium anodised barrel tower bolt of extruded section complete all as specified and directed
S&F 150 mm length extruded aluminium alloy handles,fabricated type, anodised complete all as specified and directed
S&F alluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast alluminium alloy and fixed of length of bolt 300 mm complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.06 sqm n exc 0.11 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 laying floor finished complete all as specified and directed.
M&L for glazed ceramic coloured tiles 300x200mmx7mm thick in vertical surfaces such as skirting/dado and risers to steps and including over 10mm thick rendering in CM 1:3 on fair faces of brick/concrete surfaces as in backing coat for tiles. etc, all as specified and directed.
S & F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S&F CI floor traps with grating complete 100mm bore outlet including jointing to waste pipe fixed in cement mortar type B1 1:2:4.
Supply and fix in repair 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, connecting to WC etc, complete all as specified and directed.
Cutting and grooving of wall for fixing of GI pipe lines and after fixing of GI pipe line and making good of all cutting surfaces
S&F 15mm bore U- PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. with all fittings completed all as specifiec and directed.
S&F 20mm bore U- PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. with all fittings completed all as specifiec and directed.
S&F wash hand basin,flat back or corner type vitreous china white of size 550 x 400 mm excluding taps, waste chain and plug and porcelain stopper but including brackets.
M/L for 25 mm thick green marble (table rubbed, and polished) in steps, jambs, pillars, windows-cill, cooking platform , jambs, urinal partition,wash basin platform and like in cement mortar 1:4 including pointing in white / coloured cement 1:2 using marble dust with admixture of pigment to match including one side full round edging including backing coat of 10 mm thick in CM 1:3 etc complete all as specified and directed.
S&F in repairs CP angle cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.( make Jaguar, Kohler , Marc)
S&Fin repair 15mm size PVC connection with PTMT nuts 450mm length.complete all as specified and directed.
S&F in repair CP pillar taps 15mm bore., cast copper alloy, chromium plated fancy type complete all as specified and directed.
S&F in repairs CP long nose bib tap 15mm bore fancy type with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs vitreous china squatting pan, white, orissa pattern pan of size 580 mm x 440 mm of standard quality with integral foot rests,and including 'P' trap or 'S' Trap complete including connection to trap and to flushing pipe, anti syphonic pipe etc., complete all as specifiedand directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25cm in hard / dense soil complete all as specifed and directed.
Removing Excavated soils exceeding 1.5KM but not exceeding 5 KM and depositing where directed.
Dismantling of solar water heater system of 2200 ltrs capacity installed at terrace which cosisting of glass tubes, stand, hot water tubes and all inlet and outlet water connection pipes, valves, sintex tanks,heater cobling etc keeping all the items in safe custody and the above all system is required to be re installed as it was including testing and commissioning complete including supply and fixing GI hot water pipe 25/40 mm dia, 25/40 mm dia valves if required at site of location Sabarmati building (NS-122).
M&L for point wiring for light/fan controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC concealed conduit having thickness not less than 2 mm with all fittings including modular steel sunk box having thickness not less than 2 mm including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour and all as specified .Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)(Make of copper wire:Le Grand/Havells/Polycab and PVC conduit Make: Precision,Plaza)
All as per Item No 108 here-in-before but for 5 pin 5 amps socket outlet on the same board with other switch all as specified.
All as per Item No 108 here-in-before but for but for 5 pin 5 amps socket outlet indenpendent board of light point all as specified.
M&L for point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLSH with and in and including PVC concealed conduit having thickness not less than 2 mm with all fittings including modular sunk box having thickness not less than 2 mm including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLSH as earth continuity conductor connected to common earth dolly.and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching existing colour and all as specified . Note: colour coding is to be maintained .(Ph-Red, N-Black, Half-Yellow, Earth- Green)(Make of copper wire:Legrand/standard/Havells and PVC conduit Make: Precision,Plaza)
M&L for ceiling rose three terminals AC 240 volts 50Hz complete all as specified of make: Havells/Legrand/Cona
Supply and fixing modular ceiling fan regulator 120 watt 2 module AC 240 volt complete all as specified and directed.
M&L for switch modular one way 6/5 amps 1 module complete all as specified.of make: legrand/ Havells/Elvira(Indo Asian)
M&L for switch modular one way 15/20 amps 1 module complete all as specified.of make: legrand/ Havells/Elvira(Indo Asian)
M&L for socket modular 6Amp 2/3 pin combined 2 module complete all as specified and directed.
M&L for socket modular 16/20 Amp 2/3 pin combined 2 module complete all as specified and directed.
Supply and fix in repairs MCB SP 240 Volts 5 to 32 Amps breaking capacity 10 KA rating complete all as specified and directed.Legrand/Schneider/Siemens
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 4 way double door with din rail and 200 Amp bus bar complete all as specified and directed. Make: Legrand/Schneider/Siemens
Supply and fixing modular metal flush box 3 module complete all as specified and directed.
Supply and fixing modular metal flush box 6 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 3 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 6 module complete all as specified and directed.
Material and Labour for tube light fitting LED 18 watt with decorative end caps made out of CRCA sheet powder coated complete with housing t with aluminium heat sink on back of leds ,power factor >0.9,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting and shall be fitted on new plastic square/round block complete all as per specified and directed. Make: philips / Havells /CG, Tecnocomercially equivalent in Luccar etc Note:1.Contractor shall produce LM79 & LM80 test reports from OEM owned NABL accredited laboratory.Contractor shall also produce certificates for power factor and surge protection from the company at no extra cost.
Supply and fix in repairs MCB SPN 240 Volts 5 amp to 32 amp brealing capacity 10 KA rating complete all as specified and directed.
Supply and fixing ceiling fan 1200 mm sweep with electronic fan regulator flush type 230 volt BEE 5 star rating and provisioning of flexible copper cord of size 23/0.0076 of required length from ceiling rose to connector to celing fan complete with down rod, blades, canopies etc complete all as specified and directed Make CG (HS Plus- 5 star) /Havells/Orient
DWARKESH STRUCT-CON
Vijay Enterprises
M/s Qureshi Construction Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .