Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.72Accepted-AOC | ₹28.72 Quoted ₹29.5 L | L1 | Accepted-AOC L1 |
| 2 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | MAXON HEALTHCARE INDIA PRIVATE LIMITED L1 |
|---|---|---|---|---|
| 1.00 | S/I/T/C of vaccum pump 5 HP with tank 500 ltr. Pressure switch, bacteria filter, silencer, isolation valve, copper pipe connection of vaccum pump only complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. | 2 | P.Set | 5,20,000 ₹10.4 L |
| 2.00 | Medcial compressed air system :-
S/I/T/C of air compressor 5 HP with tank 280 ltr. Pressure switch, isolation valve, copper pipe connection of air compressor only complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. | 2 | P.Set | 7,10,000 ₹14.2 L |
| 3.00 | S/I/T/C of air dryer 20 CFM with copper piping system complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. | 1 | P.set | 1,30,000 ₹1.3 L |
| 4.00 | S/I/T/C of 3 KVA UPS with 6 no. batteries for air dryer backup complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work.
- Each battery : 12 V 26 Ah (30 minute backup)
- DC Bus Voltage : 72 V (typical)
- Batteries in series : 6 batteries | 1 | Each | 58,000 ₹58,000 |
| 5.00 | Repairing work of oxygen analyzer for PSA plant complete in all respect upto the entire satisfaction of Engineer in charge of the work.
- Sensor replacement of calibration.
- Cleaning and maintenance
- Checking of electronic circuit or display faults.
- Sampling system repair
- Sofware or configuration reset | 1 | Each | 2,68,000 ₹2.7 L |
| 6.00 | Foundation of vaccum pump complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work.
- RCC foundation
- 800mm (W) x 1200mm (L) minimum size required
- 250 - 300 mm (H) minimum required | 2 | Each | 15,000 ₹30,000 |
Tender Value
₹28.0 L
EMD Value
₹56,000
Closing Date
6 Mar 2026, 5:00 pmClosed
NAVIN KUMAR
ED - Gurgaon
Special Repair EI, Medical Gas pipe line, / PSA Plant, AHU Chiller and Up-gradation of 11 KV sub station in Civil Hospital Sec-10 Gurugram (Special Repair of medical gas pipe line work)(RECALL)
2026_HRY_504806_1
20267E9FDE5B BCB3 454B A857 60001E7215ED664BAR
Open Tender
Civil Works
90 days
Gurugram
2 documents required · 2 mandatory
₹5,000
₹56,000
Yes
5 Jun 2026
25 Feb 2026
9 Mar 2026
25 Feb 2026
6 Mar 2026
25 Feb 2026
25 Feb 2026 - 26 Feb 2026
S/I/T/C of vaccum pump 5 HP with tank 500 ltr. Pressure switch, bacteria filter, silencer, isolation valve, copper pipe connection of vaccum pump only complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work.
Medcial compressed air system :- S/I/T/C of air compressor 5 HP with tank 280 ltr. Pressure switch, isolation valve, copper pipe connection of air compressor only complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work.
S/I/T/C of air dryer 20 CFM with copper piping system complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work.
S/I/T/C of 3 KVA UPS with 6 no. batteries for air dryer backup complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. - Each battery : 12 V 26 Ah (30 minute backup) - DC Bus Voltage : 72 V (typical) - Batteries in series : 6 batteries
Repairing work of oxygen analyzer for PSA plant complete in all respect upto the entire satisfaction of Engineer in charge of the work. - Sensor replacement of calibration. - Cleaning and maintenance - Checking of electronic circuit or display faults. - Sampling system repair - Sofware or configuration reset
Foundation of vaccum pump complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. - RCC foundation - 800mm (W) x 1200mm (L) minimum size required - 250 - 300 mm (H) minimum required
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.09 MB
BOQ_583526.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid