Replacment of Damged Pole Wire etc
2024_PVVNL_922293_1
Replacment of Damged Pole Wire etc
Open Tender
Electrical Works
Item Rate
60 days
office of the S.E., EUDC-II, Sec-18, Noida.
Attached in DOC
2 documents required · 2 mandatory
₹3,540
S.E. EUDC-II, Noida.
₹95,000
22 May 2024
15 Apr 2024
4 May 2024
15 Apr 2024
4 May 2024
15 Apr 2024
Amount
33@11 ds0oh0 midsUnz lsDVj&100 ls iksf"kr lsDVj 100 ,o lsDVj&99 dh Hkwfexr ttZj ,y0Vh0 dsfcy dks cnyus dk dk;Za
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 3 to 5
LT XLPE CABLE ALU. 3.5X70 SQMM
LT XLPE CABLE ALU. 3.5X150 SQMM
LT XLPE CABLE ALU. 3.5X240 SQMM
Supply and Errection of the ABOVE Following material AND SUPPLY & ERRECTION OF THE FOLLOWING MATERIAL for completing the work as per RESPO.
Providing of Best Quality Rigid PVC Pipe 110mm OD x Thickness 6.1mm x 2.5mtr Long.
Laying of LT XLPE Alu. Cable in the air on cable Riser Double Pole, existing trench cable trench, nala x-ing with providing G.I.Pipe 6" inch Dia and making connection with LT over head line at both ends.
Laying and commissiong of LT XLPE Alu. Cable in above Rigid PVC Pipe after digging trench of dia 220 mm by manual method at a depth of 1.50 mtrs to 2.50 mtrs. (as requirement at site) below the ground level for laying cable and refilling of trench including connections at both ends after providing and crimping of lugs of proper size for completion of work and Providing & Laying of Ist Class Bricks, along the length on both side of XLPE Cable in Cable Trench (minium 18No. Bricks/Mtr per Cable) and Stone Slab of size 450x600x50mm on top of the Cable, Providing 150 thickness mm River sand for cushion beneath and 150mm above the cable and Back filling of excavated earth in the cable trench upto the ground level and ramming properly.
Providing and Fixing of Alu. Crimping Lugs 70sqmm
Providing and Fixing of Alu. Crimping Lugs 150sqmm
Providing and Fixing of Alu. Crimping Lugs 240sqmm
Removal of Existing Old and Jarjar LT XLPE Cable from the site and its safe carriage to any store centre to PVVNL Discom including loading and unloading both ends.
33@11 ds0oh0 fctyh?kj lsDVj 100 ,o 39 dh {kfrxzLr 1&1ux Qsflx ,oa fifyaFk Bhd djkus dk dk;ZAleLr lkexzh o dk;Z dk;Znk;h laLFkk }kjk lEikfnr djk;k tkuk gS iw.kZ VuZdh ijA
Construction of New Plinth FOR Distribution Transformers, The size of plinth shall be 2M long 2m wide and the height of the plinth shall be 1.50 M with 20 cm. thick top slab with 02 no. 125x65mm MS channel 2 M long embedded in it. The repairing work includes excavation of earth, laying of brick ballast pad for foundation brickwork, CC and plastering and proper curing. The ratio of cement/course sand/fine sand/brick ballast/stone grit as per RESPO schedule including unloading and Loading of the transformer with complete work in all respect. (All work and material in the scope of the Contractor)
Construction of New Fencing of Transformer. The fencing shall be frame of size 1.5mt x1.80 mt fabricated out of MS angle iron of size 40x40x5 mm having 2 Nos. legs of 45 Cm. long in each frameduly welded and fixed with wire mesh of size 75mm 25mm, 10 SWG within the frame, pressed under MS flat of size 25x5 mm inside the angle iron on all four sides with the help of approx. 20 Nos. bolts and nuts. of 10 mm dia along with cross bracing of 25x5 mm MS flat on every frame will be grouted in 1:2:4 cement mortar with cement, coarse sand 20 mm gauge stone ballast in the size 0.22x0.22x0.45 Mtrs. Every frame after repairing will be painted with one coat of red oxide and two coats of blue synthetic enamel paint of approved make after proper cleaning. The above mentioned frame will be jointed with each other with 70 mm long MS flat of size 25x5mm by first class welding as per site. Fabrication and providing of wire mesh fencing frame for gate of size 1.5x180 Mtrs. Fabricated as items no. 2 and fixing of gate frame at each S/S as per site requirement with grouted frame providing 3 Nos. 100 mm size heavy duty hinges duly welded and having suitable locking arrangment and proper painting.
fo|qr uxjh; forj.k mi[k.M & 6] uks,Mk ds {ks= esa lSUpqjh ,ikVZesUV esa iSuy ds vUrxZr 200 o 400 ,Eih;j dh 17 ua0 ,e0lh0lh0ch0 yxkus dk dk;ZA
Providing of MCCB 400 Amp 4 Pole with all realeted accessories Make Havells/ L&T/Legrand/HPL etc.
Disconnection all connections from damaged MCCB which was installed in Meter Panel Box
Installation of New MCCB 400Amp. 4 Pole with all accessories after replacement of Old and Damaged MCCB.
Re-connection of all connections in Newly Installed MCCB and Commissiong of New MCCB.
Providing and installation of LT ACB 800 Amp. with cabinet / structure (Make L&T, Schneider, ABB, Hevell's, C&S, HPL etc.) as per following specification on Turnkey Basis with all relevant certificate :-
800amp. 03 pole fixed manual ACB.
Red/yellow/blue light indication
ON & OFF Indication
Amp., Volt meter& energy meter digital
Metering C.T 800/5A,
Panel fabrication of size 1250mm x 900mm x 600 mm made of M.S sheet 14 gauge with powder coating with panel lock and key arrangement.(two nos). and additional locking arrangement seprately including providing hut type shape as per drg.
Fabrication of aluminium bus-bar for each phases
Incoming size 425 mm x 50mmx12 mm (twin)
Out going size 720 mm x 50mm x 12 mm(twin)
Neutral size 900mmx50mmx12 mm.
Fabrication of pannel stand made of M.S Angle of size 900mm x 600mm x 500 mm as per drg.
Assembly of above ACB, Indicators, Meters, Metering CT & bus bar arrangment in the panel, fitting the panel on Stand with nut and bolts with wiring etc. & grouting in ratio 1:4:8 with cement, coarse sand and brick blast.
Providing and fixing of aluminium bus bar of size 300mmx60mmx12 mm on L.T side of T/F.
Making all connections with ACB & Distribution T/F and commissioning the ACB complete in all respect.
PROVIDING AND INSTALLATION OF CHEMICAL EARTHING FOR ACB (WITH ALL MATERIAL AND LABOUR) AFTER INSTALLATION RESISTANCE SHOULD BE LESS THAN ONE OHM. AS PER FOLLOWING (The all material and labour shall be provided by the contractor)
Providing of earth elctrode for chemical earthing Pipe in pipe type proper hot deep galvanization dia 50 mm length 3 mtr - 32mm x 6mm terminal connection hole dia 8mm The cavity between the pipe & pipe is filled with conductive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystalline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be galavanized the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested for LT ACB installed at different DTs.
Providing and fixing of GI strip of size 32 mm x 6 mm suitable for LT ACB installed at different DTs.
Providing and fixing of PVC Pit covers for above earthing electrode terminals.
Providing AND FIXING of Al. Lug size 400mm./800mm AS PER SITE REQUIREMENT.
Anubhavi Constructions
Anjali Electricals
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .